At least 649 records · Page 36

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 8: Life-Cycle Testing and Analysis

Prior to a spacecraft launch, program mission assurance standards dictate that the flight battery power system should comply with mission requirements under the intended operating conditions. Ground life cycle testing (LCT) combined with an analysis on the electrical power system (EPS) battery is an empirical method used to demonstrate compliance to satellite service life requirements. The LCT compliance method adopted by the aerospace industry is based on demonstrating a space battery's life expectancy as a part of battery qualification. Real-time cell and lithium-ion battery (LIB) LCT data are commonly used for model inputs to EPS power and energy balance analyses, in LIB reliability analysis estimates, and to support on-orbit spacecraft mission life extension opportunities. This chapter describes the LCT planning steps, process approach, and analysis techniques commonly used to qualify space LIB power systems.

accelerated aging↗

Explained: Reliability of the Current Power Grid

Maintaining reliability of the bulk power system, which supplies and transmits electricity, is a constant focus of electric grid planners, operators, and regulators. Based on the standards set by power system reliability entities, the U.S. grid has been and continues to be very reliable. Over the past decade the average U.S. customer has only experienced about 15 minutes of outages per year due to supply limitations, with most of those outages occurring due to failures on the distribution system. However, there have been a few notable incidents in recent years tied to extreme weather events. The fact sheet provides and introduction to reliability of the bulk power system in the U.S.

power grid↗

Case Study: Applying the Idaho National Laboratory Resilience Framework to St. Mary’s, Alaska

The Idaho National Laboratory (INL) resilience framework has been developed to broadly apply to EEDS so that all elements of systems that contain distributed wind can be part of the resilience evaluation. The users or audience for this framework can include any stakeholders associated with the EEDS. Not all electrical energy systems have the same stakeholders; customers, owners, and operators are generally present but have different interests. Considering the broad electrical grid, customers, regulators, investors, utility planners, engineers, and operators each have an interest in system resilience driven from different motivating factors. This document focuses on the planning stage of the framework. In this document, each step is explained briefly before demonstrating its application to the St. Mary’s-Mt. Village system. The framework can be used for many types of resilience planning. It can be used to evaluate current overall resilience, or the resilience of certain subsystems. It can be used to explore existing resilience weak points and propose mitigations. It can also be used to evaluate the resilience benefits of a new investment. We use the latter application for this case study. Although the wind turbine in St. Mary’s has already been installed, the resilience benefits that the turbine provided were not well defined. It was installed with the main objective to generate electric power from a renewable resource in an effort to reduce the local dependency on fuel oil as the sole source of electric power generation, which is a resilience goal on its own, but there are other ways in which the turbine can add resilience to the system, as well as scenarios of interest to analyze how resilient the wind turbine itself is against different hazards. In this case study, we analyze the operation of the St. Mary’s power system both with the wind installed and without the wind installed during different resilience hazards of interest. This allows us to compare the performance with wind and without wind and to quantify the resilience benefits provided by wind. Our MIRACL partners at PNNL will then take the resilience benefits and assign value to the resilience provided by wind based on costs and costs avoided in the different scenarios.

17 WIND ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Optimal Transactive Energy Trading of Electric Vehicle Charging Stations With On-Site PV Generation in Constrained Power Distribution Networks

This paper presents a two-level transactive energy market framework, that enables energy trading among electric vehicle charging stations (EVCSs). At the lower level, the discharging capability of EVs and on-site PV generation are leveraged by individual EVCS for participating in the transactive trading with their peers. Once the lower-level trading is completed, EVCSs trade energy at the upper level through the power grid network managed by the distribution system operator (DSO). The upper-level market is cleared while satisfying the power distribution network constraints. A cooperative game-based model is proposed to model the energy trading among EVCSs. To this end, the asymmetric Nash bargaining method is applied to allocate the grand coalition's payoff to each EVCS at the upper-level market, while a weighted proportional allocation method is used to allocate individual EVCS's payoff to its respective EVs at the lower-level market. In this work, the upper-level market formulation is further decomposed into two subproblems representing an energy scheduling and trading subproblem which maximizes EVCS payoffs, and a bargaining subproblem which allocates EVCS payoffs. The effectiveness of the proposed framework for incentivizing transactive trades among EVs and EVCSs is validated in case studies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Net-zero Microgrid Program Report: Microrred de la Montaña Feasibility Study (Executive Summary Extended)

This feasibility study provides the technical and economic rationale for the Microrred de la Montaña as a viable solution for supplying reliable and resilient electricity to an underserved region in Puerto Rico – a region that is the first to be disconnected from the grid and the last to be restored, enduring months long outages. It begins the process of the development of the microgrid through conceptual design, engineering, detailed electrical design, implementation, and operation. The Microrred de la Montaña is organized under the governance of the Cooperativa Hidroeléctrica de la Montaña (Cooperativa) which has legal status as a cooperative and power provider under the laws of Puerto Rico. The members are the municipalities of Adjuntas, Jayuya, Lares and Utuado with a combined population of 90,000. These municipalities are in central Puerto Rico – a mountainous region that is extremely vulnerable to weather events and excessive, long-duration power outages and are among the poorest and most disadvantaged regions in Puerto Rico. Funding from external sources is necessary to acquire the resources for a resilient power delivery system. Regulatory support is necessary to establish operational relationships with the incumbent power providers. The Microrred de la Montaña is envisioned as a resilient microgrid that manages distributed energy resources – local solar, storage, and hydroelectricity over an upgraded distribution network within the boundaries of four municipalities. This feasibility study provides the results of an extensive techno-economic analysis to form a sound basis for decision-making by community leaders, their constituents, funding and investment agencies, and regulators to realize the benefits that are achievable by fully implementing the design and planning recommended for the Microrred de la Montaña.

13 HYDRO ENERGY↗

Exploring Dynamic P-Q Capability and Abnormal Operations of Inverter-Based Resources

Nowadays, inverter-based resources are rapidly growing in electric power systems. On the other side, abnormal inverter operations are also occurring more often. Traditionally, inverter PQ capability charts are employed by electric utility companies to ensure safe and reliable operations of inverter-based resources. However, it is found in this paper that existing inverter PQ capability charts do not address the operating characteristics of an inverter correctly, which can result in irregular and unstable inverter operations. Here in this paper, a novel study is conducted to investigate inverter PQ capability charts, where constraints that are specific to an inverter are considered. It is found in this paper that the inverter PQ capability charts exhibit a unique dynamic nature under uncertain grid conditions. This dynamic nature has not been considered by the industry in managing, designing, and controlling an inverter as well as in developing international standards for inverter-based resources. Via both electromagnetic transient simulation and hardware experimental investigations, it is found that the dynamic PQ capability nature, together with the limitations of the existing control methods, are the underlying causes of many unusual inverter operations that have been reported in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

Resilient Hierarchical Networked Control Systems: Secure Controls for Critical Locations and at Edge

Integration of information and communication technology (ICT) offers new opportunities in improving the management and operation of critical infrastructures such as power systems as it allows connection of different sensors and control components via a communication network, leading to the so-called networked control systems (NCS). However, the use of open and pervasive ICT such as the Internet or wireless communication technologies comes at a price of making NCS vulnerable to cyber intrusions/attacks which may cause physical damage. Here, this chapter presents control algorithms to ensure resilient and safe operation of NCS under unknown cyberattacks. Specifically, a variant of dynamic watermarking strategies is presented by embedding encoding/decoding components of chaotic signals into the NCS for secure control for critical locations where the measurement/control signals are transmitted to/from the control center via a communication network. In addition, resilient cooperative control algorithms are discussed to ensure safe operation at edge of the NCS which consists of a large number of distributed controllable devices. Several numerical examples are provided to illustrate the proposed control strategies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Transmission-mounted combined energy recovery drive

An energy recovery drive system includes a motor-generator that is structured to selectively operate in a motor mode and a generator mode. A first shaft is operatively coupled to a transmission power take-off shaft. A second shaft is operatively coupled to the motor-generator and to an alternative power source. The energy recovery drive system is controllably operated in a plurality of operating modes. In a first operating mode, the motor-generator is in torque providing engagement with each of the first and second shafts. In a second operating mode, the motor-generator is in torque communicating engagement with each of the first and second shafts. In a third operating mode, which the motor-generator is in torque communicating engagement with the second shaft and is disengaged from transferring torque to the first shaft and from receiving torque from the first shaft.

Correa, Dixon Malcolm↗

A review of energy storage for power system resilience: Functions, metrics, and applications

Aging infrastructure, increasing operational complexity, and surging electricity demand from artificial intelligence and electrification are straining the grid and heightening the risks of disruptions, making resilience a critical priority. Energy storage is increasingly deployed to provide critical power supply, fast grid support, and rapid restoration. However, current practice lacks consistent metrics and systematic methodologies to rigorously quantify the resilience benefits of storage. This paper provides a comprehensive review of energy storage in resilience enhancement, focusing on functional roles, quantification metrics, and integration strategies. A structured resilience metrics library is compiled and categorized to encompass both technical and economic performance aspects. Existing methodologies for resilience-oriented storage planning and operations are critically examined. Key technical and practical challenges are identified, and future research directions are outlined to strengthen storage contributions to grid resilience.

Benefit quantification↗

Nonlinear model predictive control for mode‐switching operation of reversible solid oxide cell systems

Abstract Solid oxide cells (SOCs) are a promising dual‐mode technology for the production of hydrogen through high‐temperature water electrolysis, and the generation of power through a fuel cell reaction that consumes hydrogen. Switching between these two modes as the price of electricity fluctuates requires reversible SOC operation and accurate tracking of hydrogen and power production set points. Moreover, a well‐functioning control system is important to avoid cell degradation during mode‐switching operation. In this article, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional‐integral (PI) control strategies, while switching between the modes of hydrogen and power production. While both control methods provide similar performance across various metrics during mode switching, NMPC demonstrates a significant advantage in reducing cell thermal gradients and curvatures (mixed spatial‐temporal partial derivatives), thereby helping to mitigate long‐term degradation.

08 HYDROGEN↗

Generator Interconnection Cost Analysis in the Southwest Power Pool (SPP) Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 845 projects from interconnection studies for the Southwest Power Pool (SPP) Territory. The studies were performed between 2002 and 2023 and include all of the most refined cost estimates available. Project-level cost summary data are available for download on this page. We find: -Project-specific interconnection costs can differ widely. -Average interconnection costs are stable for projects that complete all interconnection studies but have escalated for those that withdraw. -Broader network upgrade costs are the primary driver of recent cost increases, especially for withdrawn projects. -Potential interconnection costs of all solar and wind requests have been greater than those of storage and natural gas projects. -Economies of scale exist for completed wind and solar projects but not for other fuel types or withdrawn projects. -Interconnection costs vary by location. Berkeley Lab publishes a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application: Preprint

This paper compares two control schemes in the application control layer of a non-PLL grid-forming (GFM) inverter to gain the insights and understanding of how the two schemes affect the dynamic responses of the GFM inverters and the transition operation of microgrids. Both schemes can achieve smooth microgrid transition operation and power tracking, however, the first scheme expects to exhibit more transients due to the feedforward of the inverse dynamic model of the output filter. Simulation results show that both control schemes achieve successful transition operation with smooth transients, and the second control scheme exhibits slightly better transients in the system frequency during islanding operation and the first one has slightly superior transients in the system frequency during reconnection operation. The power tracking performance in the grid-connected mode is evaluated, which shows that the first scheme has better active power tracking and the second one has better reactive power tracking. The analysis and results are useful to develop reliable control schemes for non-PLL GFM inverters because more and more inverters will work as non-PLL grid-forming sources in the future grids due to better stability and reliability.

grid-forming inverter↗