Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Improved Platform for the Benchtop Study of Complex Radiological Environments that Affect Fallout Formation: DHS Feasbility Study (Final Report)

Fallout analysis is a crucial field of study as it provides insight into the structural interactions that occur between radiological components and their surroundings following a nuclear event. Due to the complexity of actual fallout samples, setups like the plasma flow reactor (PFR) at LLNL have been developed to synthesize fallout in a controlled environment. While the PFR allows for control of parameters such as initial temperature, cooling rate, and concentration of radiological species, controlling the concentration of water has remained a challenge as samples are introduced into the setup via aqueous solution. To that end, our goal with this project was to develop methodologies to (1) monitor and (2) control the presence of water in the PFR. We found that a commercially available FTIR and MCT detector was sufficient to monitor the presence of both condensed and vapor-phase water, while a desolvating nebulizer could be used to control the amount of water injected into the system. In total, the results of this feasibility study have expanded the ability of the flow reactor to investigate key sensitivities that influence fallout formation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sensitivity to Cabibbo-Suppressed $\Lambda$ Production in MicroBooNE

We present a procedure to measure a flux averaged, restricted phase space cross section for direct (Cabibbo suppressed) Λ production using the MicroBooNE detector. This is a rare process, exclusively occurring in anti-neutrino interactions and to maximise the sensitivity of this analysis we combine predictions using the NuMI flux from two data taking periods, one in which this beam was run in neutrino mode and one in anti-neutrino mode. The event selection for this analysis was previously described in MicroBooNE public note 1097. The calculation of systematic uncertainties is shown and a method to propagate them through to the final cross section calculation is described, with final sensitivities shown in the form of Bayesian posterior distributions on the extracted cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The X-ray variability of Vela X-1 (3U 0900-40)

From observations of Vela X-1 with the MSSL 2.5-7.5 keV detector onboard Copernicus, the behavior of the source can be characterized by three phases: (1) high intensity, (2) low intensity, and (3) eclipse. Combining data from the 1972 Uhuru observations with eclipse observation yields a binary period of 8.963 + or - 0.001 days with zero phase on 1975 Feb. 6.97 + or - 0.04 UT. The low intensity phase is interpreted as being due to increased absorption in an accretion wake traveling across the line of sight (the spectral slope remains relatively constant throughout the cycle). Another period of enhanced absorption immediately after exit from eclipse may be due to a bow shock. Comparison of the two observations suggests that these structures vary from cycle to cycle and, since the orbital period is long, probably during each cycle.

Charles, P. A.↗

Correlation spectrometer having high resolution and multiplexing capability

A correlation spectrometer permanently incorporates a reference cell and an electro-optical phase modulator (EOPM) in the light path between a sample cell and a detector. The effect of the EOPM is such that its frequency modulates all of the monochromatic component of the incoherent radiation passing through it. The EOPM is adjusted so that when it is ON all of the energy in the monochromatic components is thrown into sidebands differing from the original frequencies by integral multiples of the modulation frequency with the total amount of energy absorbed from the original radiation remaining constant. When there is no coincidence between the constituents in the two cells, the detector's output is the same when the EOPM is ON and when it is OFF. However, when there is coincidence the detector's output changes when the EOPM is switched between its two states. The change in the detector's output is related to the quantity of the constituents in the sample cell.

Margolis, J. S.↗

Fine time structure in the 1979 March 5 gamma ray burst

Data on the impulsive phase of the 1979 March 5 gamma ray burst, taken by three identical detectors aboard the Prognoz 7, Venera 11, and Venera 12 spacecraft with 2 ms time resolution, are presented. The first 200 ms of the time history may be described by an exponential decay with time constant of approximately 120 ms up to approximately 100 ms, and time constant of approximately 30 ms thereafter; at low energies, a pulsating component with a period of approximately 23 ms appears. The data could be consistent with torsional vibrations of a neutron star, the rotation of a rapidly spinning neutron star, or oscillations caused by interactions between hot plasma and a magnetic field.

Barat, C.↗

Photometry of Phoebe

The nonsynchronous rotational period and light curve for Phoebe are analyzed. The variations in CCD chip pixel response, the intensity of the images, the sky background level, and the atmospheric effects and color response of the detector are examined. Consideration is also given to brightness variations and the solar phase function at small phase angles (0.2-1.2 deg) of the light curve. The Phoebe surface is compared with asteroid surfaces by fitting the data to a linear phase function. It is determined that the Phoebe's sidereal rotational period is refined to 9.282 + or - 0.015 hr, the light curve in V filter exhibits 20 percent brightness variations with weaker higher-order harmonics, and the solar phase coefficient at angles less than 1.2 deg is 0.180 + or 0.035 mag/deg. The Phoebe data at small phase angles correlated well with a phase function for C-type asteroids.

Kruse, S.↗

Evolution of a localized Langmuir packet in the solar wind and on auroral field lines

Langmuir emissions in space are reported to be clumpy and intermittent. The high-frequency wave power appears concentrated in spatial packets, whether amidst the solar wind or on auroral field lines. Due to the plasma motion relative to the spacecraft, determining the source for the wave free energy in the three-dimensional electron distribution function has always been difficult, since the unstable features pass by the detector in presumably too short time to be measured. The range of unstable phase velocities and growth rates have generally been estimated rather than determined by unequivocal measurements. The analysis of wave-particle interactions in a space environment has taken recently a new turn with the development of wave correlators on board rockets and satellites. Such instruments seek to identify correlations between the phase of the wave-field and the fluxes of energetic particles. The data interpretation is complex, however, it must be backed by a detailed theoretical understanding of the wave-particle interaction, including the phase relation for inhomogeneous packets. To this end Langmuir packets interacting with fast electrons can be studied in the appropriate regime by means of particle-in-cell simulations, provided that one succeeds in reducing the level of the fluctuations, enhancing the signal-to-noise ratio, and incorporating the appropriate boundary conditions. The first results of such simulations are presented here as a test and expansion of previous analysis.

Roth, I.↗

Physics and Chemistry of Te and HgTe-based Ternary Melts

Historically, the theoretical treatment of the liquid phases has always been more difficult and complicated than that for solid and gas phases. A liquid has no lattice structure as crystalline solids and the atoms/molecules in the liquid can migrate through it relatively rapidly. On the other hand, it is also interacting with many other atoms/molecules so that the simplifications of the kinetic theory of gases cannot be employed. For more complicated liquids, such as the liquids of high ionicity and those containing hydrogen bonds and electric dipoles, the understanding is far from complete. At the same time, accurate information on the physics and chemistry of semiconductor melts is needed for the quantitative descriptions of the process of crystal growth from melt. The pre-crystallization phenomena in the liquid phase are critical because the properties of the grown crystals depend on the state and structure of the melt as well as the thermal history of the melt during solidification process. However, the data on the liquid phase, such as thermophysical properties of semiconductor melts are scarce, especially for the HgTe-based II-VI ternary compound semiconductors because of their high vapor pressure and extreme toxicity. Analysis of the thermophysical properties of the melt can provide information about structural transitions of the melt during the solidification process. From a broader point of view, the structure of liquids is much more complicated than the crystalline solids, especially the relaxation behavior through different thermal histories. The theory of hetero-phase fluctuations of liquids is applicable to any many-body systems including condensed-matter physics, field theory, physics of nuclear-matter, cosmology, biology and even sociology. This book summarizes the physics and chemistry from the experimental measurements and theoretical analyses of phase diagram, thermodynamic properties, density, thermal conductivity, viscosity, and electrical conductivity on the binary, pseudo-binary and ternary melts of the most advanced IR-detector material systems of HgCdTe and HgZnTe as well as the analyses of these results. The main objectives of this study are: (1) to provide the phase diagrams and thermodynamic properties of Hg-Cd-Te and Hg-Zn-Te systems through quantitatively fitting the experimental data by assuming an associated solution model for the liquid phase, (2) to experimentally measure the thermophysical properties of the Hg-Cd-Te and Hg-Zn-Te melts, including density, viscosity, electrical conductivity and thermal conductivity as functions of temperature and composition and (3) to enhance the fundamental knowledge of hetero-phase fluctuations and relaxation phenomena in the melts and extend our understanding of the solidification process in order to interpret the experimental results of crystal growth so as to improve the melt growth processes of the compound semiconductor. The physics and chemistry of Te and HgTe-based ternary melts were explored through the studies of the structural transformation during melting, the supercooling during solidification, the relaxation phenomena after rapid cooling of the melts and the metal-semiconductor transition in the melts through the analyses of electrical conductivity and Lorenz number. An in-depth study on the thermophysical properties and their time-dependent structural dynamic processes taking place in the vicinity of the solid-liquid phase transition of the narrow homogeneity range HgTe-based ternary semiconductors as well as the analysis of the homogenization process in the melt will also be presented.

Thermophysical properties↗

Generalizing mkFit and its Application to HL-LHC

mkFit is an implementation of the Kalman filter-based track reconstruction algorithm that exploits both thread- and data-level parallelism. In the past few years the project transitioned from the R&D phase to deployment in the Run-3 offline workflow of the CMS experiment. The CMS tracking performs a series of iterations, targeting reconstruction of tracks of increasing difficulty after removing hits associated to tracks found in previous iterations. mkFit has been adopted for several of the tracking iterations, which contribute to the majority of reconstructed tracks. When tested in the standard conditions for production jobs, speedups in track pattern recognition are on average of the order of 3.5x for the iterations where it is used (3-7x depending on the iteration). Multiple factors contribute to the observed speedups, including vectorization and a lightweight geometry description, as well as improved memory management and single precision. Efficient vectorization is achieved with both the icc and the gcc (default in CMSSW) compilers and relies on a dedicated library for small matrix operations, Matriplex, which has recently been released in a public repository. While the mkFit geometry description already featured levels of abstraction from the actual Phase-1 CMS tracker, several components of the implementations were still tied to that specific geometry. We have further generalized the geometry description and the configuration of the run-time parameters, in order to enable support for the Phase-2 upgraded tracker geometry for the HL-LHC and potentially other detector configurations. The implementation strategy and high-level code changes required for the HL-LHC geometry are presented. Speedups in track building from mkFit imply that track fitting becomes a comparably time consuming step of the tracking chain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exciting prospects for detecting late-time neutrinos from core-collapse supernovae

The importance of detecting neutrinos from a Milky Way core-collapse supernova is well known. An understudied phase is proto-neutron star cooling. For SN 1987A, this seemingly began at about 2 s and is thus probed by only 6 of the 19 events (and only the $\bar{ν}_e$ flavor) in the Kamiokande-II and IMB detectors. With the higher statistics expected for present and near-future detectors, it should be possible to measure detailed neutrino signals out to very late times. Here, we present the first comprehensive study of neutrino detection during the proto-neutron star cooling phase, considering a variety of outcomes, using all flavors, and employing detailed detector physics. For our nominal model, the event yields (at 10 kpc) after 10 s—the approximate duration of the SN 1987A signal—far exceed the entire SN 1987A yield, with ≃ 250 $\bar{ν}_e$ events (to 50 s) in Super-Kamiokande, ≃ 110 ν e events (40 s) in the Deep Underground Neutrino Experiment (DUNE), and ≃10 $ν_μ, ν_τ, \bar{ν}_μ, \bar{ν}_τ$ events (to 20 s) in the Jiangmen Underground Neutrino Observatory. These data would allow unprecedented probes of the proto-neutron star, including the onset of neutrino transparency and hence its transition to a neutron star. If a black hole forms, even at very late times, this can be clearly identified. But will the detectors fulfill their potential for this perhaps once-ever opportunity for an all-flavor, high-statistics detection of a core collapse? Maybe. Further work is urgently needed, especially for DUNE to thoroughly investigate and improve its MeV capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 +/- 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 +/- 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 +/- 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 +/- 11% of lunar-sourced neutrons received in collimation, or 1.2 +/- 0.2 cps global average. The pole-to-equator contrast ratio in epithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80deg north or south latitude is ∼105 ppmw (parts per million by weight), or 0.095 +/- 0.01 wt% water-equivalent hydrogen. Above 88deg north or south, the concentration increases to ∼140 ppmw, or 0.13 +/- 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ∼13-40 cm into the surface.

T A Livengood↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.

Livengood, Timothy A.↗

Research on radiation detectors, boiling transients, and organic lubricants

The accomplishments of a space projects research facility are presented. The subjects discussed are: (1) a study of radiation resistant semiconductor devices, (2) synthesis of high temperature organic lubricants, (3) departure from phase equilibrium during boiling transients, (4) effects of neutron irradiation on defect state in tungsten, and (5) determination of photon response function of NE-213 liquid scintillation detectors.

Source record↗

Observed On-Orbit Background of the ACIS Detector on the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic X-rays. The ACIS instrument contains 8 Front-Illuminated (FI) CCDs and 2 Back-Illuminated (BI) CCDs. The FI and BI CCD)s exhibit dramatically different responses to enhancements in the particle flux. The F1 CCDs show relatively little increase in the overall count rate, typical increases are 1 - 3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The duration of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the power-law. The events produce morphologies which are similar to cosmic X-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, P. P.↗

Chandra Observations of the Crab Pulsar as a Function of Pulse Phase

The Chandra X-Ray Observatory was used to observe the Crab Nebula and its pulsar using the LETGS, i.e. the Low-Energy Transmission Grating (LETG) with the High Resolution Camera Spectroscopy detector (HRC-S). Data from the zeroth-order image was utilized to isolate the pulsar from the surrounding nebula and to measure the pulsar emission as a function of pulse phase. HRC timing problems were overcome by developing special techniques to process the data. For the first time, pulsed x-ray emission has been detected at all pulse phases, allowing us to set a new upper limit to the thermal emission from the surface of the neutron star.

Weisskopf, Martin C.↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Global Maps of Lunar Neutron Fluxes from the LEND Instrument

The latest neutron spectrometer measurements with the Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) are presented. It covers more than 1 year of mapping phase starting on 15 September 2009. In our analyses we have created global maps showing regional variations in the flux of thermal (energy range < 0.015 eV) and fast neutrons (>0.5 MeV), and compared these fluxes to variances in soil elemental composition, and with previous results obtained by the Lunar Prospector Neutron Spectrometer (LPNS). We also processed data from LEND collimated detectors and derived a value for the collimated signal of epithermal neutrons based on the comparative analysis with the LEND omnidirectional detectors. Finally, we have compared our final (after the data reduction) global epithermal neutron map with LPNS data.

Epithermal neutrons↗

LISA phase measurement technique

The LISA mission will form the equivalent of a Michelson interferometric beat signal from the 1064nm laser beams traversing the inter-spacecraft arms. The design gravitational wave sensitivity requires measurement of round trip path differences for each detector to be about 10 pddHz over a frequency range from 10^10-4 to 10^-1 Hz. Thus LISA'S phasemeter must measure the beat signal phase to 10^-5 cycle/square root of Hz at 1mHz. Doppler shifts between spacecraft in their orbits are expected to range from 1 to 15 MHz. Phase measurement using the digital phase-locked loop approach incorporated in a modified TurboRogue GPS receiver has been investigated in this study. It is found that only resolution in the range of 10^-4 to 10^-3 cycle/square root of Hz at 1 mHz is achievable with this hardware. Abrupt fluctuations in the phase measurement at the millicycle level are responsible for the limitation.

phasemeter↗