Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Flight data analysis and further development of variable-conductance heat pipes

Continuing efforts in large gains in heat-pipe performance are reported. It was found that gas-controlled variable-conductance heat pipes can perform reliably for long periods in space and effectively provide temperature stabilization for spacecraft electronics. A solution was formulated that allows the control gas to vent through arterial heat-pipe walls, thus eliminating the problem of arterial failure under load, due to trace impurities of noncondensable gas trapped in an arterial bubble during priming. This solution functions well in zero gravity. Another solution was found that allows priming at a much lower fluid charge. A heat pipe with high capacity, with close temperature control of the heat source and independent of large variations in sink temperature was fabricated.

Enginer, J. E.↗

Atmosphere control for plant growth flight experiments

An atmosphere exchange system (AES) has been designed to provide a conditioned atmosphere supply to plant specimens in flight without incurring the large weight and volume associated with bottled gases. The paper examines the atmosphere filter cartridge (AFC) designed to remove trace organic atmosphere contaminants from the Space Shuttle cabin and to condition the cabin atmosphere prior to exposure to plant specimens. The AES and AFC are described and illustrated. The AFC design requirements are discussed and results are presented from tests on the performance of the AFC. Also, consideration is given to the potential applications of the AFC and future design concepts for atmosphere control.

Powell, Ferolyn T.↗

Recent testing of 30 KW hydrogen arcjet thrusters

NASA is conducting efforts to evaluate high-power hydrogen arcjets for orbit transfer propulsion applications. As part of this program, an attempt was made to reexamine both radiatively- and regeneratively-cooled, 30 kW thrusters first demonstrated by the Giannini Scientific Corp. in 1963. The arcjets were configured to force arc attachment upstream of the throat in a subsonic chamber region. While thruster currents were steady, the voltage traces exhibited sawtooth waveforms at frequencies on the order of 20 kHz. Voltage variations per cycle were typically between 100 and 310 volts, indicating major changes in the position of the arc attachment with time. When operated at their respective design points, the performance of both thrusters fell below the values listed in the 1960's development reports. The reason for the discrepancies is not currently understood and further investigations are in progress. However, the recently measured efficiencies were high compared to those obtained with constricted-arc designs at similar conditions, and further arcjet performance optimizations may be possible.

Haag, Thomas W.↗

Recent testing of 30 kW hydrogen arcjet thrusters

NASA is conducting efforts to evaluate high-power hydrogen arcjets for orbit transfer propulsion applications. As part of this program, an attempt was made to reexamine both radiatively- and regeneratively-cooled, 30 kW thrusters first demonstrated by the Giannini Scientific Corp. in 1963. The arcjets were configured to force arc attachment upstream of the throat in a subsonic chamber region. While thruster currents were steady, the voltage traces exhibited sawtooth waveforms at frequencies on the order of 20 kHz. Voltage variations per cycle were typically between 100 and 310 volts, indicating major changes in the position of the arc attachment with time. When operated at their respective design points, the performance of both thrusters fell below the values listed in the 1960's development reports. The reason for the discrepancies is not currently understood and further investigations are in progress. However, the recently measured efficiencies were high compared to those obtained with constricted-arc designs at similar conditions, and further arcjet performance optimizations may be possible.

Haag, Thomas W.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Understanding Sampling Hardware Cleanliness from Perseverance Lessons Learned, and Forward Approach to Biosignature Missions

The search for biosignatures on other solar system bodies drives the scientific objectives of many ongoing and proposed exploration missions, including the Europa Lander mission concept.[1] The detection of trace and unfamiliar biosignatures in extreme environments necessitates state-of-the-art scientific instrumentation with extraordinary sensitivity – and often, extraordinary susceptibility to terrestrial and spacecraft self-induced contamination vectors.[2] While instruments can be carefully designed to operate remotely at high performance, in situ scientific measurements can only analyze the samples they’re given: samples or sample handling hardware that have been inadvertently tainted by outgassed organic molecules, thruster plume effluents, or other common sources of spacecraft contamination may yield ambiguous or false results. Maintaining and verifying the purity of collected samples and the cleanliness of sample handling hardware throughout the lifecycle of biosignature detection missions like Europa Lander is a primary responsibility of the Contamination Control group at JPL.

Alred, John↗

Development of trace gas detection instrumentation

Breadboard hardware was constructed to demonstrate detection of a gaseous species by the heterodyne principle. The characteristics of the component parts were investigated and preliminary measurements were made to establish the sensitivity and selectivity of the method for gas analysis of CO, CO2, and N2O. A prototype heterodyne gas analyzer was designed, built, and brought into operational condition. Performance parameters of the prototype analyzer were investigated and its sensitivity to CO2 measured. Further development was undertaken for both the optical bench and the electronic processor components. A three-gas prototype analyzer, capable of measuring the gases CO, CO2, and CH4 was also constructed and tested. Detailed descriptions of the work and results are presented.

Source record↗

Densitography - A new method for evaluation of cardiac performance of rest and during exercise.

The validity of the densitographic curves obtained from the pinna of the ear for measuring the systolic intervals has been investigated in 28 subjects. This technique is found to permit the performance of noninvasive physiologic studies during physical activities, exercise tests, flight conditions, and probably long-term monitoring of critically ill patients. Densitographic curves constitute an excellent substitute by which to measure time-base intervals of the cardiac cycle when the carotid pulse tracing is not available.

Chirife, R.↗

Artificial meteor ablation studies: Olivine

Artificial meteor ablation was performed on a Mg-rich olivine sample using an arc-heated plasma of ionized air. Experimental conditions simulated a meteor traveling about 12 km/sec at an altitude of 70 km. The mineral content of the original olivine sample was 98% olivine (including traces of olivine alteration products) and 2% chromite. Forsterite content of the original olivine was Fo-89. After ablation, the forsterite content had increased to Fo-94 in the recrystallized olivine. In addition, lamella-like intergrowths of magnetite were prevalent constituents. Wherever magnetite occurred, there was an increase in Mg and a corresponding decrease in Fe for the recrystallized olivine. The Allende fusion crust consisted of a recrystallized olivine, which was more Mg-rich and Fe-deficient than the original meteorite's olivine, and abundant magnetite grains. Although troilite and pentlandite were the common opaque mineral constituents in this meteorite, magnetite was the principal opaque mineral found in the fusion crust.

Blanchard, M. B.↗

Equivalence of equations describing trace element distribution during equilibrium partial melting

It is shown that four equations used for calculating the evolution of trace-element abundances during equilibrium partial melting are mathematically equivalent. The equations include those of Hertogen and Gijbels (1976), Shaw (1970), Schilling (1971), and O'Nions and Clarke (1972). The general form to which all these equations reduce is presented, and an analysis is performed to demonstrate their mathematical equivalence. It is noted that the utility of the general equation flows from the nature of equilibrium (i.e., the final state is independent of the path by which that state is attained).

Consolmagno, G. J.↗

Seasat: - JASIN workshop report. Volume 1: Findings and conclusions

Data acquired from the Joint Air-Sea Interaction (JASIN) Experiment and Seasat data from overpasses that covered the JASIN area were compared and evaluated. The JASIN data were used as a high quality withheld data set. The Seasat data were prepared for each instrument: the Seasat-A Satellite Scatterometer (SASS), the Scanning Multichannel microwave radiometer (SMMR), and the synthetic aperture radar (SAR). The following results demonstrate the performance of Seasat: it was possible to identify mesoscale systems with the SASS as well as fronts; the SMMR provided accurate water vapor content of the atmosphere; the SAR showed evidence of helical rolls in the marine boundary layer; a SASS anomaly could be traced back to thunderstorm activity.

Source record↗

Numerical Aerodynamic Simulation (NAS)

The history of the Numerical Aerodynamic Simulation Program, which is designed to provide a leading-edge capability to computational aerodynamicists, is traced back to its origin in 1975. Factors motivating its development and examples of solutions to successively refined forms of the governing equations are presented. The NAS Processing System Network and each of its eight subsystems are described in terms of function and initial performance goals. A proposed usage allocation policy is discussed and some initial problems being readied for solution on the NAS system are identified.

Peterson, V. L.↗

ATLAS-2 and UARS correlative measurement opportunities during Space Shuttle mission on April 8-17, 1993

The second ATmospheric Laboratory for Applications and Science (ATLAS-2) mission was flown aboard the Space Shuttle Discovery from 8-17 Apr. 1993. The nighttime launch at 0529 Greenwich Mean Time provided maximum solar occultation sunrise coverage of the northern latitudes by the Atmospheric Trace Molecule Spectroscopy instrument. The ATLAS-2 Earth-viewing instruments provided a large number of measurements which were nearly coincident with observations from experiments on the Upper Atmosphere Research Satellite (UARS). Based on instrument operating schedules during the ATLAS-2 mission, simulations were performed to determine when and where correlative measurements between ATLAS and UARS instruments occurred. Results of these orbital and instrument simulations provide valuable information for the ATLAS and UARS scientists to compare measurements between various instruments on the two satellites.

Harrison, Edwin F.↗

Latest Development in Radiative Transfer Models and Retrieval Algorithms Using Principal Components

The radiative transfer model (RTMs) has a wide range of applications in satellite remote sensing and atmospheric radiation applications. However, millions of line-by-line (LBL) radiative transfer calculations at fine monochromatic frequencies are needed in order to properly calculate spectral contributions of water vapor and trace gases in the atmosphere in infrared and solar spectral regions. Therefore, fast and accurate RTMs are needed to efficiently process large amount of satellite data. A Principal Component-based Radiative Transfer Model (PCRTM) was first developed in 2004 at NASA Langley Research Centre to fulfil this need. By using PC-compression, one can reduce the data dimension significantly while maintaining original information content. The PCRTM can directly compute PC-scores and their derivatives with respect to retrieved parameters. The PCRTM can simulate the top-of-atmosphere (TOA) radiance or reflectance spectra from 0.250 µm (400000 cm-1) to 2000 µm (50 cm-1) with several orders of magnitude faster speed as compared to a LBL RTM. It is also extremely accurate compared to LBL RTM benchmarks (0.03 K RMS error in IR and 0.05% in solar). The PCRTM model has been developed for hyperspectral sensors such as AIRS, CrIS, IASI, NAST-I, SHIS, FIRST, and CLARREO-IR in thermal IR spectral region and CLARREO-Solar, CPF, TEMPO, EMIT, OMI, and SCIAMACHY in solar spectral region. The PCRTM accuracy has been demonstrated via RTM intercomparisons and with real satellite observations from AIRS, CrIS, IASI, SCHIAMACHY, and EMIT etc. In this presentation, we will describe two PCRTM-based inversion algorithms to retrieve atmospheric temperature, water vapor, and trace gas profiles, as well as cloud and surface properties from hyperspectral sounders such as AIRS, CrIS, IASI, and NAST-I. The first one is called Single Fieldof-view Sounder Atmospheric Product (SiFSAP) algorithm. It provides L2 products with 9-times higher area spatial resolution as compared to current cloud-clearing sounder algorithms. The SiFSAP L2 and L3 products are available at NASA's Goddard Earth Sciences Data and Information Services Center (GES DISC) for public access. The second inversion algorithm is called Climate Fingerprinting Atmospheric Product (ClimFiSP) algorithm. It is designed to produce high quality climate products (trends, anomalies, daily, and monthly profiles of temperature, water vapor, traces, clouds, and surface properties) from multiple satellite sensors such AIRS on Aqua and CrIS on multiple satellites. This product will be available at NASA GES DISC later this year. The PCRTMbased high fidelity simulators for CLARREO and CPF have been used for sensor performance trade studies, algorithm development, and inter-satellite calibrations. We have also used PCRTM generated TOA radiance spectra to train an AI-based algorithm and successfully retrieved cloud properties from EMIT solar hyperspectral imagers.

PCRTM↗

Measurement of HO2 and other trace gases in the stratosphere using a high resolution far-infrared spectrometer at 28 KM

The major events and results to date of the ongoing program of measuring stratospheric composition by the technique of far-infrared Fourier-transform spectroscopy from a balloon-borne platform are reviewed. The highlights of this period were the two balloon flight campaigns which were performed at Palestine, Texas, both of which produced large amounts of scientifically useful data.

Traub, Wesley A.↗

Deriving Essential Climate Variable Data from Multiple Satellite Remote Sensors Using a Consistent Fingerprinting Method

Hyperspectral observations from satellite-based sensors provide high information content for the Earth’s atmospheric and surface properties. Traditionally, long-term climate products are derived by performing spatial and temporal averaging of level-2 satellite products. It is a time-consuming process to generate level-2 data products since modern hyperspectral satellite sensors have millions of observations each day with thousands of spectral channels for each observation. Additionally, differences in level-2 retrieval algorithms can lead to errors in the climate products when fusing data from different satellite sensors. We have developed a radiometrically consistent spectral fingerprinting method, which overcomes the above-mentioned shortcomings, to derive climate change signals from multiple satellite sensors using spatiotemporally averaged level-1 data. We have applied this method to Atmospheric Infrared Sounder (AIRS) and Cross-track Infrared Sounder (CrIS) data and generated decade-long climate data records for atmospheric temperature, water vapor, cloud, trace gases, and surface skin temperature. A key component to this work is a set of observational-based radiative kernels produced from CrIS level-1 data using a single field of view (SFOV) optimal estimation retrieval algorithm. Only limited CrIS level-1 data (e.g., 1-2 years of data) are needed to the derive radiative kernels. Our Principal Component-based Radiative Model (PCRTM) enables us to perform SFOV retrievals under all sky conditions and provides radiative kernels (including those for clouds) needed by the spectral fingerprinting method. In this presentation, we will describe the basic methodology, the details of the algorithm, and results from NASA Aqua AIRS and Suomi-NPP CrIS data. The method can be applied to study future hyperspectral remote sensors such as CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF), Tropospheric Emissions: Monitoring of Pollution (TEMPO), Surface Biology and Geology (SBG), Aerosol and Cloud, Convection and Precipitation (ACCP).

Xu Liu↗

Polarization Performance Simulation for the GeoXO Atmospheric Composition Instrument: NO2 Retrieval Impacts

NOAA's Geostationary Extended Observations (GeoXO) constellation will continue and expand on the capabilities of the current generation of geostationary satellite systems to support US weather, ocean, atmosphere, and climate operations. It is planned to consist of a dedicated atmospheric composition instrument (ACX) to support air quality forecasting and monitoring by providing capabilities similar to missions such as TEMPO (Tropospheric Emission: Monitoring Pollution), currently planned to launch in 2023, as well as OMI (Ozone Monitoring Instrument), TROPOMI (TROPOspheric Monitoring Instrument), and GEMS (Geostationary Environment Monitoring Spectrometer) currently in operation. As the early phases of ACX development are progressing, design trade-offs are being considered to understand the relationship between instrument design choices and trace gas retrieval impacts. Some of these choices will affect the instrument polarization sensitivity (PS), which can have radiometric impacts on environmental satellite observations. We conducted a study to investigate how such radiometric impacts can affect NO2 retrievals by exploring their sensitivities to time of day, location, and scene type with an ACX instrument model that incorporates PS. The study addresses the basic steps of operational NO2 retrievals: the spectral fitting step and the conversion of slant column to vertical column via the air mass factor (AMF). The spectral fitting step was performed by generating at-sensor radiance from a clear-sky scene with a known NO2 amount, the application of an instrument model including both instrument PS and noise, and a physical retrieval. The spectral fitting step was found to mitigate the impacts of instrument PS. The AMF-related step was considered for clear-sky and partially cloudy scenes, for which instrument PS can lead to errors in interpreting the cloud content, propagating to AMF errors and finally to NO2 retrieval errors. For this step, the NO2 retrieval impacts were small but non-negligible for high NO2 amounts; we estimated that a typical high NO2 amount can cause a maximum retrieval error of 0.25×1015 molec. cm−2 for a PS of 5 %. These simulation capabilities were designed to aid in the development of a GeoXO atmospheric composition instrument that will improve our ability to monitor and understand the Earth's atmosphere.

Aaron Pearlman↗

Artificial meteor ablation studies - Olivine

Artificial meteor ablation has been performed on a Mg-rich olivine sample by means of an arc-heated plasma of ionized air. Experimental conditions simulated a meteor traveling about 12 km/sec at an altitude of 70 km. The mineral content of the original olivine was 98% olivine (including traces of olivine alteration products) and 2% chromite. The forsterite content of the original olivine was Fo 89 and increased to Fo 94 in the recrystallized olivine after ablation. In addition, lamella-like intergrowths of magnetite were prevalent. Wherever magnetite occurred, Mg increased and Fe decreased in the recrystallized olivine. The Fe for the magnetite exsolved from the original olivine crystals. Individual particles (i.e., spherules) were also characterized by magnetite intergrowths. Fusion crusts on the Allende and Murchison meteorites were compared with the fusion crust on the olivine sample. The Allende fusion crust consisted of a recrystallized olivine, richer in Mg and deficient in Fe in comparison with the original meteorite's olivine, and abundant magnetite grains.

Blanchard, M. B.↗