Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

New-Sum: A Novel Online ABFT Scheme For General Iterative Methods

Emerging high-performance computing platforms, with large component counts and lower power margins, are anticipated to be more susceptible to soft errors in both logic circuits and memory subsystems. We present an online algorithm-based fault tolerance (ABFT) approach to efficiently detect and recover soft errors for general iterative methods. We design a novel checksum-based encoding scheme for matrix-vector multiplication that is resilient to both arithmetic and memory errors. Our design decouples the checksum updating process from the actual computation, and allows adaptive checksum overhead control. Building on this new encoding mechanism, we propose two online ABFT designs that can effectively recover from errors when combined with a checkpoint/rollback scheme.

Instantaneous Footprint↗

SMT-Aware Instantaneous Footprint Optimization

Modern architectures employ simultaneous multithreading (SMT) to increase thread-level parallelism. SMT threads share many functional units and the whole memory hierarchy of a physical core. Without a careful code design, SMT threads can easily contend with each other for these shared resources, causing severe performance degradation. Minimizing SMT thread contention for HPC applications running on dedicated platforms is very challenging, because they usually spawn threads within Single Program Multiple Data (SPMD) models. To address this important issue, we introduce a simple scheme for SMT-aware code optimization, which aims to reduce the memory contention across SMT threads.

Instantaneous Footprint↗

MapReduce MPI library (MR-MPI) v. 1.0

The MapReduce MPI library is a software tool for performing MapReduce operations on a distributed memory parallel computer via message passing (MPI). These are data-processing or computational operations which achieve parallelism by breaking a large task into two stages, a map and a reduce . Each of these are formulated as simple on-processor functions which the user can easily write. The library assigns independent tasks to processors and performs the parallel data movement and transformations behind the scenes.

PLIMPTON, STEVEN↗

HERON

HERON is a modeling toolset and plugin for RAVEN to accelerate stochastic technoeconomic assessment of the economic viability of various grid-energy system configurations, especially with application to electrical grids and integrated energy systems (IES). The frameworks enabling this toolset are INL's RAVEN and its TEAL plugin. The toolset includes automated RAVEN workflow generation tools for performing stochastic analysis and optimization driven by technoeconomic factors. The workflows generated employ RAVEN for parametric or optimizing study of grid component characteristics, and again for stochastic sampling of regulated and deregulated markets, load, and weather histories. The toolset further provides methods for economically-optimal dispatch of system components given the stochastic samples of market, load, and weather histories. The toolset allows assembling of existing and new models through the RAVEN interface to the Modelica process modeling language.

Talbot, PaulW↗

TripleGraph

RDF triplestores are great tools for online graph analytic processing (i.e., graph pattern query processing), but they do not provide graph mining capabilities (e.g., PageRank, connected-component analysis, node eccentricity, etc.). The software title “TripleGraph” is a graph analysis toolkit, which uses an RDF triplestore as its backend for creating, manipulating, mining, and programming with large scale property graphs. It allows users to run various graph mining algorithms easily. User can import edgelist-formatted (homogeneous graph) or JSON-formatted graph (property graph) into the RDF triplestore using the provided tool and perform various analysis such as (1) Node/edge retrieval and manipulation, (2) Pathfinding between two given nodes, (3) Running graph mining algorithms (PageRank/Personalized PageRank, Single Source Shortest Path/Multi-Source Shortest Path, Connected Component, Node Eccentricity, Peer Pressure Clustering). It supports standard graph data format and works with a standard SPARQL endpoint like Jena Fuseki. It allows users to perform online graph analytic processing and graph mining on the same platform (a triplestore).

Sangkeun, MattLee↗

dkainer/RWRtoolkit

a set of command-line and R tools for performing Random-walk with Restart analyses on multiplex networks in any species

Kainer, David↗

Multi-Channel Time-Frequency Analysis

This software contains models for multi-channel time series data. The models are time-frequency descriptions of the data. Also included are prediction performance evaluation tools. These models can be applied to electrophysiology data such as electrocorticography.

Kaplan, AlanD↗

Parallel Dislocation Simulator

ParaDiS, or Parallel Dislocation Simulator, is a simulation tool that performs direct numerical simulation of dislocation ensembles, the carriers of plasticity, to predict the strength in crystalline materials from the fundamental physics of defect motion, evolution, and interaction. The code has been successfully deployed on high performance computing architectures and used to study the origins of strength and strain hardening for cubic crystals, the strength of micro-pillars, and irradiated materials at LLNL. The ParaDiS code has been successfully deployed on more than one hundred thousand CPU's with over ten million active degrees of freedom.

Bulatov, Vasily↗

pnnl/HNSRigidBodySimulator

HNS Rigid Body Simulatoris a tool for performing rigid-body dynamics simulations of nanoscale systems (e.g., macromolecular assemblies) in Python.

Marina, Sofia↗

pnnl/ZebrafishBMD

ZebrafishBMD: A software tool to perform benchmark dose calculations using toxicity screening data of high-throughput zebrafish assays. High-content imaging of larval zebrafish behavior can be used as a screening approach to rapidly evaluate the relative potential for chemicals to cause toxicity. However, most statistical methods applied to these data transform movement values to incidence-based “hits” and calculate lowest effect levels (LELs), which loses individual fish resolution of behavior and defies hazard ranking due to reliance on applied dose levels. We developed a parallelizable workflow to calculate benchmark dose (BMD) values from dynamic, high-content zebrafish behavior data that scales for high throughput chemical screening. To capture the zebrafish movement response from light to dark stimulus, we summarized time-dependent data using both area under the curve and the immediate change at the transition point into two novel metrics that characterized abnormal behavior as a function of chemical concentration. The BMD workflow was applied to calculate BMD10 values of 1,060 ToxCast chemicals for 24 zebrafish endpoints, including behavior, mortality and morphology. ZebrafishBMD implements the BMD workflow and provides Matlab scripts to read the data (stored in a specific structure) from a .mat file, to calculate the behavioral endpoint values from movement versus time data, to construct concentrationresponse curves, to perform curve-fitting, and to calculate BMD10 values.

Thomas, Dennis↗

Impala

SAND2025-07450O Impala is a software tool that performs Bayesian model calibration for emulator-based models. The program uses R code to perform the calculations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Tucker, James [Sandia National Lab. (SNL-CA), Live↗