Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Dual-Channel Enzymatic Inhibition Measurement (DEIM) Coupling Isotope Substrate via Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

A novel dual-channel enzymatic inhibition measurement (DEIM) method was developed to improve the repeatability with light/heavy isotope substrates, producing reliable relative standard deviations (< 3%) by employing acetylcholinesterase (AChE) as the model enzyme. The matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) was adapted for enzyme-inhibited method due to its good salt-tolerance and high throughput; meanwhile, dual-channel enzymatic reactions were performed to improve the repeatability of each well. The acetylcholinesterase inhibition measurement was conducted by mixing the quenched enzyme reaction solution of blank group (with heavy isotope as substrate) and experimental group (with light isotope as substrate), of which the inhibition rate might be affected by isotope effects. Hence, inverse study and Km measurement were implemented to validate the method. The inverse study shows similar inhibition rate (68.9 and 70.3%) and the Km of isotope substrates are analogous (0.139 and 0.135 mM), which demonstrated that the novel method is feasible to AChE inhibition measurement. Finally, the method was applied to herb extracts, half of which exhibit inhibition to AChE. The precise dual-channel enzymatic inhibition measurement (DEIM) method could be regarded as a promising approach to potential enzyme inhibitor screening. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of chronic low-dose/dose-rate high-LET irradiation from radium-226 in a human colorectal carcinoma cell line

Purpose: To evaluate potential damages of chronic environmentally relevant low-dose/dose-rate high-LET irradiation from a naturally occurring alpha-emitting radionuclide (radium-226, {sup 226}Ra) on a human colorectal carcinoma HCT116 p53{sup +/+} cell line. Methods: Clonogenic survival assays and mitochondrial membrane potential (MMP) measurement with a sensitive fluorescent MMP probe JC-1 were performed in HCT116 p53{sup +/+} cells chronically exposure to low doses/dose rates of {sup 226}Ra with high-LET. Comparisons were made with the human non-transformed keratinocyte HaCaT cell line and acute low-dose direct low-LET gamma radiation. Results and conclusion: The chronic low-dose/dose-rate alpha radiation (CLD/DRAR) did not reduce the clonogenic survival of HCT116 p53{sup +/+} cells over the period of 70 days of exposure. Only one significant reduction in the HCT116 p53{sup +/+} cells’ clonogenic survival was when cells were grown with 10,000 mBq/mL {sup 226}Ra for 40 days and progeny cells were clonogenically assessed in the presence of 10,000 mBq/mL {sup 226}Ra. The cumulative doses that cells received during this period ranged from 0.05 to 46.2 mGy. The mitochondrial membrane potential (MMP) dropped initially in both HCT116 p53{sup +/+} and HaCaT cells in response to CLD/DRAR. The MMP in HCT116 p53{sup +/+} cells recovered more quickly at all dose points than and that in HaCaT cells until the end of the exposure period. The highest dose rate of 0.66 mGy/day depolarized the HaCaT's mitochondria more consistently during the exposure period. The faster recovery status of the MMP in HCT116 p53{sup +/+} cells than that in HaCaT cells was also observed after exposure to acute low-dose gamma rays. Overall, it was found that CLD/DRAR had little impact on the MMP of human colorectal cancer and keratinocyte cell lines. - Highlights: • Human colorectal carcinoma HCT116 p53{sup +/+} and keratinocyte HaCaT cells were exposed to chronic low-dose/dose-rate alpha radiation (CLD/DRAR). • Unlike the HaCaT cells, HCT116 p53{sup +/+} cells’ clonogenic survival and mitochondrial membrane potential (MMP) changed little upon CLD/DRAR. • Upon the mitochondrial membrane depolarization response induced by CLD/DRAR, HaCaT cells were more sensitive than HCT116 p53{sup +/+}. • Gamma radiation depolarized the mitochondria of both HaCaT and HCT116 p53{sup +/+} in a dose-dependent manner. • The MMP in HCT116 p53{sup +/+} could recover more quickly than that in HaCaT cells after an acute low-dose gamma irradiation challenge.

54 ENVIRONMENTAL SCIENCES↗

Linear Accelerator-Based Radiosurgery Alone for Arteriovenous Malformation: More Than 12 Years of Observation

Purpose: Although radiosurgery is an accepted treatment method for intracranial arteriovenous malformations (AVMs), its long-term therapeutic effects have not been sufficiently evaluated, and many reports of long-term observations are from gamma-knife facilities. Furthermore, there are few reported results of treatment using only linear accelerator (LINAC)-based radiosurgery (LBRS). Methods and Materials: Over a period of more than 12 years, we followed the long-term results of LBRS treatment performed in 51 AVM patients. Results: The actuarial obliteration rates, after a single radiosurgery session, at 3, 5, 10, and 15 years were 46.9%, 54.0%, 64.4%, and 68.0%, respectively; when subsequent radiosurgeries were included, the rates were 46.9%, 61.3%, 74.2%, and 90.3%, respectively. Obliteration rates were significantly related to target volumes ≥4 cm{sup 3}, marginal doses ≥12 Gy, Spetzler-Martin grades (1 vs other), and AVM scores ≥1.5; multivariate analyses revealed a significant difference for target volumes ≥4 cm{sup 3}. The postprocedural actuarial symptomatic radiation injury rates, after a single radiation surgery session, at 5, 10, and 15 years were 12.3%, 16.8%, and 19.1%, respectively. Volumes ≥4 cm{sup 3}, location (lobular or other), AVM scores ≥1.5, and the number of radiosurgery were related to radiation injury incidence; multivariate analyses revealed significant differences associated with volumes ≥4 cm{sup 3} and location (lobular or other). Conclusions: Positive results can be obtained with LBRS when performed with a target volume ≤4 cm{sup 3}, an AVM score ≤1.5, and ≥12 Gy radiation. Bleeding and radiation injuries may appear even 10 years after treatment, necessitating long-term observation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-shell silicate and alumina coating for long lasting and high capacity lithium ion batteries

In this work we demonstrate a theory-driven, novel dual-shell coating system of Li 2 SrSiO 4 and Al 2 O 3 , achieved via a facile and scalable sol-gel technique on LiCoO 2 electrode particles. The optimal thickness of each coating can lead to increased specific capacity (~185 mAh/g at 0.5 C-rate) at a cut-off potential of 4.5 V, and greater cycling stability at very high C rates (up to 10 C) in half-cells with lithium metal. The mechanism of this superior performance was investigated using a combination of X-ray and electron characterization methods. It shows that the results of this investigation can inform future studies to identify still better dual-shell coating schemes, achieved by such industrially feasible techniques, for application on similar, nickel-rich cathode materials.

25 ENERGY STORAGE↗

Hydrothermal synthesis and photocatalytic activities of Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} composite micro-platelets

Highlights: • Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} composite was fabricated by combining hydrothermal reaction and molten salt method. • Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} exhibits higher photocatalytic activity than pure Bi{sub 4}Ti{sub 3}O{sub 12}. • The absorption light of Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} has been broadened to visible light. - Abstract: In this study, Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} micro-platelets were successfully synthesized by using hydrothermal and molten salt methods, and the morphology and photocatalytic degradation performance of Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} was characterized. The results indicated a much higher degradation rate of methylene blue and methylene orange, reaching more than 90% and 65%, respectively, within 3 h under visible-light irradiation. Compared with pure Bi{sub 4}Ti{sub 3}O{sub 12}, the photocatalytic activity of Bi{sub 4}Ti{sub 3}O{sub 12}/SrTiO{sub 3} was significantly better, due to the micron–submicron heterojunction with SrTiO{sub 3} reducing the band gap of Bi{sub 4}Ti{sub 3}O{sub 12}. In addition, the perovskite structure layer facilitates the mobility of the photogenerated carriers and hampers their recombination, which were affected the photocatalytic properties.

36 MATERIALS SCIENCE↗

Characterization of deep level defects and thermally stimulated depolarization phenomena in La-doped TlInS{sub 2} layered semiconductor

Lanthanum-doped high quality TlInS{sub 2} (TlInS{sub 2}:La) ferroelectric-semiconductor was characterized by photo-induced current transient spectroscopy (PICTS). Different impurity centers are resolved and identified. Analyses of the experimental data were performed in order to determine the characteristic parameters of the extrinsic and intrinsic defects. The energies and capturing cross section of deep traps were obtained by using the heating rate method. The observed changes in the Thermally Stimulated Depolarization Currents (TSDC) near the phase transition points in TlInS{sub 2}:La ferroelectric-semiconductor are interpreted as a result of self-polarization of the crystal due to the internal electric field caused by charged defects. The TSDC spectra show the depolarization peaks, which are attributed to defects of dipolar origin. These peaks provide important information on the defect structure and localized energy states in TlInS{sub 2}:La. Thermal treatments of TlInS{sub 2}:La under an external electric field, which was applied at different temperatures, allowed us to identify a peak in TSDC which was originated from La-dopant. It was established that deep energy level trap BTE43, which are active at low temperature (T ≤ 156 K) and have activation energy 0.29 eV and the capture cross section 2.2 × 10{sup −14} cm{sup 2}, corresponds to the La dopant. According to the PICTS results, the deep level trap center B5 is activated in the temperature region of incommensurate (IC) phases of TlInS{sub 2}:La, having the giant static dielectric constant due to the structural disorders. From the PICTS simulation results for B5, native deep level trap having an activation energy of 0.3 eV and the capture cross section of 1.8 × 10{sup −16} cm{sup 2} were established. A substantial amount of residual space charges is trapped by the deep level localized energy states of B5 in IC-phase. While the external electric field is applied, permanent dipoles, which are originated from the charged B5 deep level defects, are aligned in the direction of the applied electric field and the equilibrium polarization can be reached in a relatively short time. When the polarization field is maintained, while cooling the temperature of sample to a sufficiently low degrees, the relaxation times of the aligned dipoles drastically increases. Practically, frozen internal electric field or electrets states remain inside the TlInS{sub 2}:La when the applied bias field is switched off. The influence of deep level defects on TSDC spectra of TlInS{sub 2}:La has been revealed for the first time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-C-303-01: Activation-Induced Cytidine Deaminase Confers Cancer Resistance to Radiation Therapy

Purpose: To study the role of activation-induced cytidine deaminase (AID) in malignant cell resistance to radiation therapy. Methods: We first developed several small devices that could be used to adopt radiation beams from clinical high dose rate brachy therapy (HDR) or linac-based megavoltage machines to perform pre-clinical cell and mouse experiments. Then we used these devices to deliver radiation to AID-positive and AID-silenced cancer cells or tumors formed by these cells in mice. Cells and mice bearing tumors received the same dose under the same experimental conditions. For cells, we observed the apoptosis and the cell survival rate over time. For mice bearing tumors, we measured and recorded the tumor sizes every other day for 4 weeks. Results: For cell experiments, we found that the AID-positive cells underwent much less apoptosis compared with AID-silenced cells upon radiation. And for mouse experiments, we found that AID-positive tumors grew significantly faster than the AID-silenced tumors despite of receiving the same doses of radiation. Conclusion: Our study suggests that AID may confer cancer resistance to radiation therapy, and AID may be a significant biomarker predicting cancer resistance to radiation therapy for certain cancer types.

60 APPLIED LIFE SCIENCES↗

SU-F-P-53: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semi-automated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

60 APPLIED LIFE SCIENCES↗

SU-G-206-17: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semiautomated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

M4SF-19LL010302042: Pu Incorporation into Reduced Iron Oxide Phases

The research is focused on actinide and radionuclide sequestration in steel corrosion products. The effort described herein was focused on identifying synthesis methods for reduced Fe-oxide phases and performing Pu sorption and coprecipitation experiments to determine the fractionation of Pu into and onto these phases. Specifically, we are: Quantifying the rate of Pu incorporation to magnetite and green rust, and Characterizing the nature and morphology of sorbed and coprecipitated Pu on these phases.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Investigation of residual stress distribution in wire-arc directed energy deposited refractory molybdenum alloy utilizing numerical thermo-mechanical analysis and neutron diffraction method

Directed energy deposition (DED), a metal additive manufacturing (AM) technique, offers higher deposition rates and energy efficiency, making it suitable for fabricating components from refractory molybdenum alloys, such as molybdenum-titanium-zirconium (TZM). However, large thermal gradients and non-equilibrium thermal cycles in DED could generate high residual stress in the component, potentially deteriorating quality and performance. Thus, this study aims to investigate residual stress generation and its distribution in wire-arc DED of TZM thin-wall, utilizing thermo-mechanical analysis and high-fidelity neutron diffraction (ND) method. Two interpass temperatures (50°C and 200°C) have been considered to investigate their impact on residual stress formation. During experiments, in-situ thermal data has been recorded using thermocouples, which have been utilized for calibrating the thermal model. Thermocouple data shows a good agreement with the simulation results, having a difference of less than 10 %. Post-deposition part deformation has been observed, which is measured using a coordinate measuring machine, showing maximum values of 0.93 mm and 0.78 mm for interpass temperatures of 50°C and 200°C, respectively. Numerical predictions of distortion deviated by less than 15% from the experimental results. ND measurement and simulation results indicate that residual stress magnitude and evolution vary across the TZM deposits, revealing microstructural anisotropy in both conditions. Notably, lower interpass temperatures resulted in higher residual stresses, confirmed by experimental and simulation data. Further, this study demonstrated that an integrated experimental and thermo-mechanical analysis can potentially reveal the temperature history, part deformation, and residual stress formation in wire-arc DED TZM alloy.

36 MATERIALS SCIENCE↗

Kinetic phase evolution of spinel cobalt oxide during lithiation

Spinel cobalt oxide has been proposed to undergo a multiple-step reaction during the electrochemical lithiation process. Understanding the kinetics of the lithiation process in this compound is crucial to optimize its performance and cyclability. In this work, we have utilized a low-angle annular dark-field scanning transmission electron microscopy method to visualize the dynamic reaction process in real time and study the reaction kinetics at different rates. We show that the particles undergo a two-step reaction at the single-particle level, which includes an initial intercalation reaction followed by a conversion reaction. At low rates, the conversion reaction starts after the intercalation reaction has fully finished, consistent with the prediction of density functional theoretical calculations. At high rates, the intercalation reaction is overwhelmed by the subsequently nucleated conversion reaction, and the reaction speeds of both the intercalation and conversion reactions are increased. Phase-field simulations show the crucial role of surface diffusion rates of lithium ions in controlling this process. Furthermore, this work provides microscopic insights into the reaction dynamics in non-equilibrium conditions and highlights the effect of lithium diffusion rates on the overall reaction homogeneity as well as the performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Direct Randomized Benchmarking for Multiqubit Devices

Benchmarking methods that can be adapted to multiqubit systems are essential for assessing the overall or “holistic” performance of nascent quantum processors. The current industry standard is Clifford randomized benchmarking (RB), which measures a single error rate that quantifies overall performance. But, scaling Clifford RB to many qubits is surprisingly hard. It has only been performed on one, two, and three qubits as of this writing. This reflects a fundamental inefficiency in Clifford RB: the n-qubit Clifford gates at its core have to be compiled into large circuits over the one- and two-qubit gates native to a device. As n grows, the quality of these Clifford gates quickly degrades, making Clifford RB impractical at relatively low n. In this Letter, we propose a direct RB protocol that mostly avoids compiling. Instead, it uses random circuits over the native gates in a device, which are seeded by an initial layer of Clifford-like randomization. We demonstrate this protocol experimentally on two to five qubits using the publicly available ibmqx5. We believe this to be the greatest number of qubits holistically benchmarked, and this was achieved on a freely available device without any special tuning up. Our protocol retains the simplicity and convenient properties of Clifford RB: it estimates an error rate from an exponential decay. But, it can be extended to processors with more qubits—we present simulations on 10+ qubits—and it reports a more directly informative and flexible error rate than the one reported by Clifford RB. Here, we show how to use this flexibility to measure separate error rates for distinct sets of gates, and we use this method to estimate the average error rate of a set of cnot gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DISCRETE ELEMENT MODELING OF BLADE–STRIKE FREQUENCY AND SURVIVAL OF FISH PASSING THROUGH HYDROKINETIC TURBINES

Evaluating the consequences from blade-strike of fish on marine hydrokinetic (MHK) turbine blades is essential for incorporating environmental objectives into the integral optimization of machine performance. For instance, experience with conventional hydroelectric turbines has shown that innovative shaping of the blade and other machine components can lead to improved designs that generate more power without increased impacts to fish and other aquatic life. In this work, we used unsteady computational fluid dynamics (CFD) simulations of turbine flow and discrete element modeling (DEM) of particle motion to estimate the frequency and severity of collisions between a horizontal axis MHK tidal energy device and drifting aquatic organisms or debris. Two metrics are determined with the method: the strike frequency and survival rate estimate. To illustrate the procedure step-by-step, an exemplary case of a simple runner model was run and compared against a probabilistic model widely used for strike frequency evaluation. The results for the exemplary case showed a strong correlation between the two approaches. In the application case of the MHK turbine flow, turbulent flow was modeled using detached eddy simulation (DES) in conjunction with a full moving rotor at full scale. The CFD simulated power and thrust were satisfactorily comparable to experimental results conducted in a water tunnel on a reduced scaled (1:8.7) version of the turbine design. A cloud of DEM particles was injected into the domain to simulate fish or debris that were entrained into the turbine flow. The strike frequency was the ratio of the count of colliding particles to the crossing sample size. The fish length and approaching velocity were test conditions in the simulations of the MHK turbine. Comparisons showed that DEM-based frequencies tend to be greater than previous results from Lagrangian particles and probabilistic models, mostly because the DEM scheme accounts for both the geometric aspects of the passage event ---which the probabilistic method does--- as well as the fluid-particle interactions ---which the Lagrangian particle method does. The DEM-based survival rates were comparable to laboratory results for small fish but not for mid-size fish because of the considerably different turbine diameters. The modeling framework can be used for applications that aim at evaluating the biological performance of MHK turbine units during the design phase and to provide information to regulatory agencies needed for the environmental permitting process.

blade strike↗

Comprehensive Lateral Neck Dissection in Papillary Thyroid Carcinoma may Reduce Lateral Neck Recurrence Rates

Objective: To Identify predictors of recurrent disease following lateral neck dissection (LND) for papillary thyroid carcinoma (PTC). Methods: A retrospective review of patients who underwent first-time LND for PTC at our institution (2000–2015) was performed. Medical records were examined for biopsy or pathologically proven lateral neck recurrence. Differences between the groups with and without recurrence were compared. All LNDs were then classified in to two groups: “comprehensive” (CND), involving levels IIa-Vb at minimum, or “selective”, labelling less extensive dissection (SND). Results: Four hundred nine patients underwent 467 LNDs. Surveillance data were available for 317 patients who underwent 362 LNDs (mean age 45 ± 16; range 18–88). The median follow-up was 64 ± 48 months (range 3–197). Recurrence was detected in 71 lateral necks (20%). The total number of lymph nodes was greater in the group without recurrence compared to those with recurrence (23 vs. 19, p = 0.02). Among patient demographics, radioactive iodine treatment, primary tumor characteristics and characteristics of nodal metastases, only an older patient age (mean 50 vs. 43 years) was associated with lateral neck recurrence (p < .01). CND was performed in 102 lateral necks and SND in 143 necks. There were 12 recurrences recorded in the CND group (12%) vs. 31 in the SND group (22%, p = .04). The majority of recurrences (70%) involved levels included in the original dissection. Conclusions: Younger patients, more extensive dissection and a higher total number of lymph nodes removed are associated with a lower incidence of lateral neck recurrence after LND for papillary thyroid carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗