Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Gap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Psychomotor Vigilance Self Test on ISS (Reaction Self Test on Expeditions 21 and 22)

The experiment addresses the following high-priority NASA Risk Gaps in the Behavioral Health and Performance (BHP) area: 1) Identify brief, valid objective measures of changes in cognitive functions during spaceflight that astronauts can use with minimal burden. 2) Find a practical objective aid for astronauts to quickly identify and manage the effects of fatigue (from sleep loss, circadian disruptions, workload and other factors) on their performance during space flight.

Dinges, David F.↗

Single Operator Control of Multiple UAS: A Supervisory Delegation Approach

This presentation will be given as part of the UAS EXCOM Science and Research Panel's (SARP) workshop on multiple UAS controlled by a single operator. Participants were asked to identify public use cases for multiple UAS control and identify research, policy and technical gaps in those operations. The purpose of this workshop is to brainstorm, categorize and prioritize those use canses and gaps. Here, I will discuss research performed on this topic when I worked for the Army and on-going work within the division and a NATO working group on Human-Autonomy Teaming.

Human-Autonomy Teaming↗

Single Operator Control of Multiple UAS: A Supervisory Delegation Approach

This presentation will be given as part of the UAS EXCOM Science and Research Panel's (SARP) workshop on multiple UAS controlled by a single operator. Participants were asked to identify public use cases for multiple Unmanned Aircraft Systems (UAS) control and identify research, policy, and technical gaps in those operations. The purpose of this workshop is to brainstorm, categorize, and prioritize those use cases and gaps. Here, I will discuss research performed on this topic when I worked for the Army and on-going work within the division and a NATO working group on Human-Autonomy Teaming.

Unmanned Aircraft Systems (UAS)↗

Exploration Extravehicular Mobility Unit (xEMU) Lunar Boot Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU lunar boots. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. This paper will address only the cold environment testing results. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through a heater cage surrounding the boots. Notably, the xEMU boots also contacted the liquid-nitrogen chilled floor inside of Chamber B, which provided a conduction pathway to simulate the thermal effects of the lunar surface. Test hardware was developed to extend the water tubing from the Liquid Cooling Ventilation Garment (LCVG) into the boots to set the internal thermal boundary nominally provided by the astronaut’s foot. Thirty-three temperature sensors were used to collect data in critical locations in the xEMU boot assembly as well as for calorimetry to determine heat flux to and from the boots. This paper will document the testing results and provide a high-level interpretation of the testing results. To conclude, this paper will address possible forward work and knowledge gaps present in lunar boot thermal performance and testing.

xEMU↗

Sensorimotor Application of Proposed Methods to Combine the Effects of Multiple Countermeasures for PRisM

Risk associated with human systems is challenging to quantify but is critical for the mission planning and decision making required to enable future Lunar and Martian missions. To address this gap, the Crew Health and Performance-Probabilistic Risk Assessment (CHP-PRA) project is developing an integrated computational model for CHP mission risk. Much like how MEDPRAT is designed to allow medical resource trades informed by medical risk, CHP-PRA will enable analogous trades in human system risks across multiple CHP functions and capabilities. Human performance is one component of the risk intended to be captured by CHP-PRA through the Performance Risk Model (PRisM). The sensorimotor risk area provides a good frame of reference for investigating the structure of a performance model because most tasks that astronauts are expected to perform require input from the sensory system and/or movement/motor control. Additionally, sensorimotor countermeasures are an area of particular concern for NASA’s Human Research Program because of the increased sensorimotor risk associated with surface operations in Lunar and Martian missions. Thus, a tool that can quickly compare risk reductions of potential countermeasures would be beneficial in guiding research and development of effective countermeasures. In this proof of concept, we present a systematic way to combine multiple performance data sets for humans subjected to different countermeasures such that we can predict the countermeasure(s) that optimize astronaut performance on relevant tasks. PRisM assumes that both the tests that are used to measure countermeasure effectiveness (input data) and the tasks we use to represent astronaut performance, can be broken down and represented as a function/vector of the human systems required to perform that test/task. Through mathematical combination, test data are used to predict performance on astronaut tasks that use similar systems. We propose that when combining countermeasures evaluated using the same test, that only one value should be used to represent their combined effectiveness. We start our analysis with the assumption that two countermeasures together will perform better than each countermeasure individually. Our initial implementation of this framework compares various space motion sickness countermeasures and the most up to date analysis will be demonstrated at the IWS.

Caroline R Austin↗

Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings: Preprint

Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings

Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible, Multipurpose Laboratory Advances Building and Thermal Energy Systems: Expanding Evaluation and Development of Grid-Interactive Buildings

Robust hardware and controls are necessary to ensure results match their intent before they can be used broadly. However, this often requires multiple field experiments in a variety of climate zones. In the field, it is more difficult to obtain information on other important factors, such as thermal, grid, and occupant interaction. Gaps also exist in understanding the performance degradation and life cycle of thermal energy systems as they relate to buildings. There is a lack of robust, high-quality performance data for projects at scale; this data can be expensive to produce and often remain proprietary.

30 DIRECT ENERGY CONVERSION↗

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00↗

Challenges in Tracking Waste Reduction Performance Improvement in Manufacturing Plants

The recently released Circularity Gap Report 2023 by the Circle Economy Foundation states that the circularity score for the global economy is declining. The US Environmental Protection Agency (EPA) tracked municipal solid waste from 1960 to 2018 and found that 50% of the waste was destined for landfills. EPA estimates that US industry is responsible for 2.7 Gt of solid nonhazardous waste annually in the US mostly linear economy model. The circular economy framework aims to decouple economic value generation from the extraction of virgin materials from nature. The linear model of material extraction and disposal at the end of life is highly unsustainable. Manufacturing companies are adopting ambitious waste reduction targets to achieve sustainability. Through the Better Plants program, US DOE has established the Waste Reduction Network, which offers technical assistance to partners to achieve their ambitious waste reduction goals. Basic requirements of establishing a target include identifying a baseline, quantifying waste performance, and measuring progress over time. One problem faced by industry is unstandardized metrics for quantifying waste performance that may not be well suited to demonstrate progress. This paper studies traditional methods used to measure waste performance and highlights advantages, disadvantages, and limitations of each method. It also examines the suitability of applying the methods in different manufacturing circumstances. Finally, the paper presents a case study of a large manufacturer that faced inconsistencies in its tracked measurement metric. A solution was proposed and implemented to alter the methodology to enable more accurate waste performance tracking against a baseline.

circular economy↗

Zero-gap microbial electrolysis cells for efficient hydrogen production from real liquid waste streams

Zero-gap microbial electrolysis cells (MECs) have demonstrated large current and hydrogen production rates from defined substrates in synthetic media, but operation with real waste streams has yet to be proved. This study evaluated the performance and 30-days stability of zero-gap MECs operated with effluent from a single-stage anaerobic digester. The system achieved a maximum current density of 8.8 ± 0.3 A/m 2 with a hydrogen production rate of 32 ± 6 L/L-d, and during 30 days of continuous operation, sustained an average current density of 7 ± 2 A/m 2 and a hydrogen production rate of 20.8 ± 0.2 L/L-d. Carbonate precipitation was identified as a major challenge to long-term stability, and mild acid washing effectively mitigated its adverse effects. The low buffer capacity of the effluent was primarily limiting performance. Furthermore, these findings underscore the significant impact of wastewater chemistry on MEC operation and validate the feasibility of utilizing real waste streams as viable feedstocks for biohydrogen production in zero-gap configurations.

Acid wash↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

42 ENGINEERING↗

Harnessing Photoelectrochemistry for Wastewater Nitrate Treatment Coupled with Resource Recovery

Wastewater is a misplaced resource well suited to recover nutrients, value-added chemicals, energy, and clean water. A photoelectrochemical device is proposed to transform wastewater nitrates to ammonia and nitrous oxide, coupled with water oxidation. Numerical models were developed to quantify the dependence of process efficiencies and nitrogen-removal rates on light absorber band gaps, electrocatalytic kinetic parameters, competing oxygen reduction and hydrogen evolution reactions, and the reacting nitrate species concentrations that affect the mass-transfer limited current densities. With a single light-absorber and state-of-the-art catalysts, optimal solar-to-chemical efficiencies of 7% and 10% and nitrogen-removal rates of 260 and 395 gN m -2 day -1 are predicted for nitrate reduction to ammonia and nitrous oxide, respectively. The influence of competing reactions on the performance depends on the nitrate concentration and band gap of the light absorber modeled. Oxygen reduction is more dominant than hydrogen evolution to compete with the nitrate reduction reaction, but it is mass-transfer limited. Even with kinetic parameters that enhanced the driving forces for the competing reactions, the performance is only minimally affected by these reactions for optimally selected band gaps and nitrate concentrations larger than 100 mM. Here, theoretically predicted peak nitrogen removal rates and specific energy intensities are competitive with reported estimates for electrochemical and Sharon-Anammox processes for ammonia recovery and nitrogen removal, respectively. This result, together with the added benefit of harnessing sunlight to produce value-added products, indicates promise in the photoelectrochemical approach as a tertiary pathway to recover nutrients and energy from wastewater nitrates.

25 ENERGY STORAGE↗

pop-cosmos : redshifts and physical properties of KiDS-1000 galaxies

ABSTRACT Principled Bayesian inference of galaxy properties has not previously been performed for wide-area weak-lensing surveys with millions of sources. We address this gap by applying the pop-cosmos generative model to perform spectral energy distribution (SED) fitting for 4 million KiDS (Kilo-Degree Survey)-1000 galaxies. Calibrated on deep COSMOS2020 photometric data, pop-cosmos specifies a physically motivated prior over the galaxy population up to $z \simeq 6$ in stellar population synthesis (SPS) parameter space. Using the Speculator SPS emulator with GPU (graphics processing unit)-accelerated Markov Chain Monte Carlo sampling, we perform full posterior inference at 8.2 GPU seconds per galaxy, obtaining joint constraints on galaxy redshifts and physical properties. We validate photometric redshifts against $\sim \!185\,\!000$ KiDS galaxies cross-matched to Dark Energy Spectroscopic Instrument Data Release 1 spectroscopic samples, achieving low bias ($2\times 10^{-3}$), scatter ($\sigma _{\mathrm{MAD}}=0.03$), and outlier fraction (3.2 per cent) for the Bright Galaxy Survey, with comparable performance (bias $3\times 10^{-2}$, $\sigma _{\mathrm{MAD}}=0.05$, 1.0 per cent outliers) for luminous red galaxies (LRGs). Within the LRG sample, we identify massive, dusty, star-forming contaminants at $z \simeq 0.4$ satisfying standard colour selections for quenched populations. We infer trends in stellar mass, star formation, metallicity, and dust across five tomographic redshift bins consistent with established scaling relations. Using specific star formation rate constraints, we identify $\sim$7 per cent of KiDS-1000 galaxies as quenched, versus 37 per cent implied by conservative colour cuts. This enables the construction of weak-lensing samples defined by physical properties while mitigating intrinsic alignment systematics and preserving statistical power. Our analysis validates pop-cosmos out of sample, establishing it as a scalable approach for galaxy evolution and cosmological analyses with photometric surveys.

Halder, Anik [Institute of Astronomy and Kavli Ins↗

Imputation of urban environmental sensor data using gated attention bidirectional long short-term memory (GA-BiLSTM): methods, performance, and implications

Urban environmental monitoring networks frequently encounter significant data gaps due to sensor malfunctions, environmental disturbances, and communication failures. Reliable approaches to address these gaps are essential for ensuring the continuity and quality of environmental data streams. In this study, we developed a gated attention bidirectional long short-term memory (GA-BiLSTM) model to impute missing data in a dense urban monitoring network. Using observations from the CROCUS network in Chicago, we evaluated GA-BiLSTM against widely used approaches (XGBoost and K-nearest neighbors) under scenarios of both short-term intermittent gaps and prolonged outages. GA-BiLSTM consistently outperformed comparative methods, particularly during extended outages of up to ten days, demonstrating its ability to capture spatiotemporal dependencies across sensor nodes. Beyond performance metrics, feature importance and spatial network analyses highlighted the unexpected but critical predictive role of peripheral rural nodes, underlining their strategic value for maintaining robust urban monitoring systems. These results emphasize that advanced imputation methods can substantially improve the reliability of environmental monitoring networks and support more resilient data infrastructures for urban sustainability.

Data imputation↗

Over 11% Efficient Eco-Friendly Kesterite Solar Cell: Effects of S-Enriched Surface of Cu2ZnSn(S,Se)4 Absorber and Band Gap Controlled (Zn,Sn)O Buffer

For high efficiency kesterite Cu2ZnSn(S,Se)4 (CZTSSe) solar cell, CdS thin film was usually used as a buffer layer. However, due to the toxicity of Cd and pollution problems involved from the solution-based chemical bath deposition, eco-friendly high efficiency CZTSSe solar cell with Cd-free buffer is necessary. As an Cd-free buffer layer, we investigated (Zn,Sn)O (ZTO) film deposited by sputtering method. In order to achieve high power conversion efficiency, we controlled energy band gaps of CZTSSe absorber as well as ZTO buffer, which was required to optimize conduction band offset (CBO) between the absorber and the buffer and to increase open circuit voltage (Voc) and fill factor (FF). The CBO was optimized by controlling the band gap of ZTO. By varying the Sn/(Zn + Sn) ratio and its deposition temperature, band gap of ZTO was successfully adjusted. Experimental and computational calculation results showed that solar cell performance was strongly affected by the CBO between absorber and buffer. Besides CBO matching, larger band gap of ZTO improved short circuit current density (Jsc) with enhanced external quantum efficiency value in blue photon spectrum range. As an additional way to improve power conversion efficiency of solar cell, band graded CZTSSe absorber was developed by using spray-based two-step process. The sprayed CZTSSe film was engineered to have S-enriched surface, which makes surface band gap widened and surface passivated, and resultantly increases Voc, Jsc and fill factor (FF). By controlling band gaps of both CZTSSe absorber and ZTO buffer, we obtained 11.22% environment-friendly CZTSSe solar cell without MgF2 anti-reflection coating.

(Zn↗

Evaluation of Graph Analytics Frameworks Using the GAP Benchmark Suite

The analysis of connected data is an increasingly important application in high-performance computing. Such analyses can reveal fraudulent patterns in financial transactions, optimize telecommunications networks, predict information flow in social networks, etc. However, the landscape of graph analytics is highly diverse. Graph algorithms stress processor architectures differently, and no one graph can represent all topologies. Consequently, no single approach or framework is expected to be optimal for all graph analytics problems. To help make sense of this diverse landscape, we evaluated four approaches to graph analytics: GraphBLAS, Galois, BGL17, GraphIt; and compare them against hand-tuned implementations that take advantage of hardware features on our test platform. Graph- BLAS formulates graph analytics as sparse linear algebra. Galois provides syntactic constructs for data parallelism over irregular data structures. BGL17 is a generic C++ template library for implementing graph algorithms. GraphIt provides a domain- specific language to describe and optimize graph algorithms. We use the GAP Benchmark Suite to establish baseline performance and guide the side-by-side evaluation of each framework. GAP consists of 30 tests: six graph analytics algorithms (breadth- first search, single-source shortest path, PageRank, betweenness centrality, connected components, and triangle counting) run on five graphs, each with different topological characteristics (e.g., high diameter, skewed degree distribution, high average degree). High-performance reference implementations are included for each benchmark algorithm. Because a graph can be loaded into memory a number of ways (e.g., flat file on disk, compressed sparse format, data frames, retrieved from SQL or NoSQL databases), our evaluation focused on computational performance rather than I/O. Our results show the relative strengths of each framework.

Graph algorithms, Benchmarking, shared-memory prog↗