At least 649 records · Page 36

WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset of peripheral seeds involved, but lateral shearing movement can have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗

Scanning Probe Microscopy in the Information Age

Scanning probe microscopy (SPM) has brought scientific exploration, visualization, and control to nanoscale. A plethora of measurement approaches and techniques devised around SPM enabled probing structure and functionalities crucial for virtually all areas of science. While high-resolution electron microscopy techniques preceded scanning probes, SPM effectively opened the door to probing the structure–property relationship on length scales spanning 100s of micrometers down to a single atom. As the complexity of the material systems and the scientific questions increased, so too did the SPM techniques. Substantial efforts have been dedicated toward the development of better instrumentation platforms, probes, and novel spectroscopic measurements; however, many opportunities related to data processing and acquisition in SPM are just being realized now. This chapter will describe the recent progress in data-driven SPM by giving a broad overview of the field, the foundation of the scanning tunneling microscope (STM) and the atomic force microscope (AFM), as well as a description behind the operating principles and dynamic modes. A comprehensive overview of the multi-frequency techniques, Band excitation, and general acquisition mode SPM is given, setting the context for the application of big data, machine learning, and artificial intelligence in the field of dynamic SPM.

Collins, Liam↗

Simulate_PCR for amplicon prediction and annotation from multiplex, degenerate primers and probes

Background: Pairing up primers to amplify desired targets and avoid undesired cross reactions can be a combinatorial challenge. Effective prediction of specificity and inclusivity from multiplexed primers and TaqMan®/ Luminex® probes is a critical step in PCR design. Results: Code is described to identify all primer and probe combinations from a list of unpaired, unordered candidates that should produce a product. It predicts and extracts all amplicon sequences in a large sequence database from a list of primers and probes, allowing degenerate bases and user-specified levels of primer-target mismatch tolerance. Amplicons hit by TaqMan®/Luminex® probes are indicated, and products may be annotated with gene information from NCBI. Fragment length distributions are calculated to predict electrophoretic gel banding patterns. Conclusions: Simulate_PCR is the only freely available software that can be run from the command line for high throughput applications which can calculate all products from large lists of primers and probes compared to a large sequence database such as nt. It requires no prior knowledge of how primers should be paired. Degenerate bases are allowed and entire amplicon sequences are extracted and annotated with gene information. Examples are provided for sets of TaqMan®/Luminex® PCR signatures predicted to amplify all HIV-1 genomes, all Coronaviridae genomes, and a group of antibiotic resistance genes. The software is a command line perl script freely available as open source.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging theory of structured pump-probe microscopy

With sub-micron spatial resolution and femtosecond temporal resolution, pump probe microscopy provides a powerful spectroscopic probe of complex electronic environments in bulk and nanoscale materials. However, the electronic structure of many materials systems are governed by compositional and morphological heterogeneities on length scales that lie below the diffraction limit. We have recently demonstrated Structured Pump Probe Microscopy (SPPM), which employs a patterned pump excitation field to provide spectroscopic interrogation of sub-diffraction limited sample volumes. Herein, we develop the imaging theory of SPPM in two dimensions to accompany the previously published experimental methodology. We show that regardless of pump and probe wavelengths, a nearly two-fold reduction in spectroscopic probe volume can be achieved. We also examine the limitations of the approach, with a detailed discussion of ringing in the point spread function that can reduce imaging performance.

47 OTHER INSTRUMENTATION↗

The Design Fabrication Installation & Evaluation of the Balance Probe Monitor for Large Centrifuges at a National Laboratory Facility.

Balance Probe Monitors were designed, fabricated, installed, and evaluated at Sandia National Laboratories (SNL) for the 22,600 g kg (50,000 g lb) direct drive electromotor driven large centrifuges. These centrifuges provide a high onset/decay rate g environment. The Balance Probe Monitor is physically located near a centrifuge’s Capacitance Probe, a crucial sensor for the centrifuge’s sustainability. The Balance Probe Monitor will validate operability of the centrifuge. Most importantly, it is used for triggering a kill switch under the condition that the centrifuge displacement value exceeds allowed tolerances. During operational conditions, the Capacitance Probe continuously detects the structural displacement of the centrifuge and an adjoining AccuMeasure 9000 translates this displacement into an output voltage.

47 OTHER INSTRUMENTATION↗

Hyper-Velocity Nanoparticle Plasma Jet as Fast Probe for Runaway Electrons in Tokamak Disruptions

The large energy focalized deposition of the runaway electron (RE) beam on the first wall can potentially yield to destructive effects on the reactor vessel during the explosive instability of a major disruption in a large tokamak (e.g. RE beam estimation is multi-MA of ~10 MeV energy in ITER.) Impurity injection is seen as an effective way to suppress REs after thermal quench (TQ). Injected material in solid state is advantageous, but it must be in small size grain form, with large surface-to-mass ratio to facilitate its rapid ablation within plasma. However, the results using shattered pellet injection (SPI), a technique aiming to satisfy these condition, indicated that the relatively unexplored RE evolution phases and RE beam-plasma interaction are far from being properly diagnosed and fully understood. We proposed the idea to probe REs with a pulsed power hyper-velocity large-mass nanoparticle plasma jet (NPPJ). NPPJ provides a high specific surface area and swift injection to core, hence fast increase of three basic parameters: 1) the electron density ne (bound and free through ionization, if the cold post-TQ plasma has a still high enough T e ), 2) the effective charge (Z eff ) which rises both the dynamical friction force and plasma resistivity, and, finally, 3) the value of the (Dreicer and critical) threshold E-field above which electrons are accelerated and become REs. But the fast transient phenomena of RE ”seed” creation, RE ”avalanche” multiplication, and RE beam formation and interaction with the background plasma all take place dominantly in the core plasma, where the induction E-field has its maximum. Thus, the RE probe success requires a rapid (1 - 2 ms) injection of sufficient mass able to penetrate through the strong toroidal magnetic field (2 - 5 T) over a long distance (~1 - 2 m) with a large assimilation fraction in the core plasma. As a RE probe, NPPJ is a unique combination of fast response with trigger-to-delivery time of few milliseconds, large mass-velocity (>75 mg at several km/s) and deep injection into post-TQ central plasma. The Objectives of this Category #1 project (concept development) were as follows: 1: We investigated the essential basic physics aspects of creating a plasma with ~10 15 to 10 16 cm -3 boron nitride (BN) NP density suited for a pulsed power plasma gun acceleration to several km/s. We concluded that, for RE NPPJ probe, BN (diameter Ø10 to 100 nm NPs) are in all respects usable. 2: We advanced solutions to get BN NPPJ by adapting FAR-TECH’s technology for C 60 NPPJ. 3: We developed self-consistent models for RE current density j RE (R; t) evolution in the TQ aftermath, with fast and simultaneous increase of n e (R; t) and Z eff (R; t) > 1 upon the specific injection of C 60 (i.e. C ions) and BN NP (i.e. B and N ions), respectively. We showed that prompt post-TQ injection and high velocity are of essence in RE probe diagnostics and suppression. 4: We used the in-house HEM-2D code to simulate the C$_{60}^{q+}$ NPPJ transverse penetration through tokamak-level B-field (BT ~2 to 5 T) and distance (~1 to 2m), with fragmentation of C$_{60}^{q+}$ and developed the algorithm for BN Q+ NPPJ ablative sublimation of BN Q+ NP by the collisions with post-TQ plasma electrons. HEM-2D results indicated that fragmenting C$_{60}^{1+}$ NPPJ penetrates up to ~60 cm in 100 us when injecting at 1.6 ms after TQ and gradually released C 2 fragments and C ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pitot-probe displacement in a supersonic turbulent boundary layer

Eight circular pitot probes ranging in size from 2 to 70 percent of the boundary-layer thickness were tested to provide experimental probe displacement results in a two-dimensional turbulent boundary layer at a nominal free-stream Mach number of 2 and unit Reynolds number of 8 million per meter. The displacement obtained in the study was larger than that reported by previous investigators in either an incompressible turbulent boundary layer or a supersonic laminar boundary layer. The large probes indicated distorted Mach number profiles, probably due to separation. When the probes were small enough to cause no appreciable distortion, the displacement was constant over most of the boundary layer. The displacement in the near-wall region decreased to negative displacement in some cases. This near-wall region was found to extend to about one probe diameter from the test surface.

Allen, J. M.↗

Separation and communications geometry analysis for a Jupiter entry probe from a Pioneer spacecraft

The separation and communications geometry analysis is presented which shows that it is possible to target a Jupiter entry probe from a Pioneer spin-stabilized vehicle to desired entry conditions and maintain a continuous line-of-sight communications link while the probe descends to a pressure of 10 bars within the atmosphere. Such a targeting is possible with either the deflected probe mode or with the deflected bus mode. For the nominal mission studied, an 800 day trip in 1978 with the Pioneer type spacecraft flying by a 1.3 R(J), it was possible to achieve entries near zero angle of attack at about -25 deg relative entry flight path angle. Because of the constraint on the deflection maneuver for the deflected probe mode, the deflection and phasing velocity requirements are much larger for this mode. The geometry parameters, look angles, ranges and range rates, provided by this analysis permit the design of a functional communications system for the bus and probe. Avoiding a high trapped radiation belt hazard at Jupiter by flying the bus by at 6 R(J), however, requires using a despun antenna on the flyby bus.

Tindle, E. L.↗

A comparative study of electrical probe techniques for plasma diagnostics

Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.

Szuszczewicz, E. P.↗

Outer planet entry probe system study. Volume 2: Supporting technical studies

The environment, science investigations, and general mission analysis considerations are given first. These data are followed by discussions of the studies pertaining to the planets Jupiter, Saturn, Uranus, and Neptune. Except for Neptune, each planet discussion is divided into two parts: (1) parametric activities and (2) probe definition for that planet, or the application of a given probe for that planet. The Neptune discussion is limited to parametrics in the area of science and mission analysis. Each of the probe system definitions consists of system and subsystem details including telecommunications, data handling, power pyrotechnics, attitude control, structures, propulsion, thermal control, and probe to spacecraft integration. The first configuration is discussed in detail and the subsequent configuration discussions are limited to the differences. Finally, the hardware availability to support a probe system and commonality of science, missions, and subsystems for use at the various planets are considered.

Source record↗

Frequency response studies for a wedge probe in viscoelastic fluids.

Investigation of a hot-film wedge probe in viscoelastic fluids by imposing on the probe a sinusoidal vibration of known amplitude and frequency. Root-mean-square (rms) velocities calculated from the displacement of the probe are compared to rms velocities obtained with a constant temperature anemometer. The tests were performed under turbulent flow conditions and also at flow rates where viscoelastic effects, i.e., decrease of heat transfer rates from the probe to the fluid and drag reduction, were observed. The experimental technique was established by measuring the response of the probe in mineral oil.

Rodriguez, J. M.↗

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

Current to a moving cylindrical electrostatic probe

The current collection characteristics of a moving cylindrical Langmuir probe are evaluated for a range of probe speeds and potentials which are applicable to earth and planetary measurements. The current expressions derived include the cases of the general accelerated current, sheath area limited current, orbital motion limited current, and retarded current. For the orbital motion limited current, a simple algebraic expression is obtained which includes and generalizes the Mott-Smith and Langmuir expressions for both a stationary probe and a rapidly moving probe. For a rapidly moving probe a single formula adequately represents both the accelerated and the retarded current.

Hoegy, W. R.↗

Electron collection theory for a D-region subsonic blunt electrostatic probe

Blunt probe theory for subsonic flow in a weakly ionized and collisional gas is reviewed, and an electron collection theory for the relatively unexplored case, Deybye length approximately 1, which occurs in the lower ionosphere (D-region), is developed. It is found that the dimensionless Debye length is no longer an electric field screening parameter, and the space charge field effect can be negelected. For ion collection, Hoult-Sonin theory is recognized as a correct description of the thin, ion density-perturbed layer adjacent the blunt probe surface. The large volume with electron density perturbed by a positively biased probe renders the usual thin boundary layer analysis inapplicable. Theories relating free stream conditions to the electron collection rate for both stationary and moving blunt probes are obtained. A model based on experimental nonlinear electron drift velocity data is proposed. For a subsonically moving probe, it is found that the perturbed region can be divided into four regions with distinct collection mechanisms.

Wai-Kwong Lai, T.↗

Current to a moving cylindrical electrostatic probe

The current collection characteristics of a moving cylindrical Langmuir probe are evaluated for a range of probe speeds and potentials which are applicable to earth and planetary measurements. The current expressions derived include the cases of the general accelerated current, sheath area limited current, orbital motion limited current, and retarded current. For the orbital motion limited current, a simple algebric expression is obtained which includes and generalizes the Mott-Smith and Langmuir expressions for both a stationary probe and a rapidly moving probe. For a rapidly moving probe, a single formula adequately represents both the accelerated and the retarded current.

Hoegy, W. R.↗

Techniques of biological contamination avoidance by atmospheric probes

The likelihood of biologically contaminating a planet by an atmospheric probe has a low probability of occurring if the probe is kept biologically clean during terrestrial operations and if the structure remains in tact until the planets life zone is completely penetrated. High standards of cleanliness, monitoring and estimating for remedial actions must be maintained in a probe program. It is not a foregone conclusion, however, that heat sterilization needs to be employed. The use of several techniques having a good potential for lower probe costs are available and appear adequate to render a probe sterile within acceptable bounds. The techniques considered to be satisfactory for minimizing microbial load include: (1) combined heat (at 95-105 C) and gamma radiation; (2) short term heating at 105 + or - 5 C to inactivate all vegetative microbes; (3) irradiation routinely by ultraviolet light; (4) wiping by a bactericidal agent with or without a penetrant; and (5) cleanliness alone.

Defrees, R. E.↗

A heavy ion beam probe system for investigation of a modified Penning discharge

An ion beam probe diagnostic system can measure time- and space-resolved profiles of plasma space potential and electron density. In combination with a computer iterative technique, the ion beam probe can determine both the space potential profile in plasmas containing strong electric fields and potentials comparable in magnitude to the energy of the probing ion beam. During ion beam probing of a modified Penning discharge, several groups of secondary ions were observed coming from the plasma with a fixed primary beam energy and momentum. The energies of these ions were within 10 percent of the values predicted by a computer-generated model of the potential profile in the plasma. The mechanical and electronic components of the system are described, with particular emphasis on those features required to probe plasma potentials comparable in magnitude to the ion beam energy.