Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High-speed dual Langmuir probe

In an effort to temporally resolve the electron density, electron temperature, and plasma potential for turbulent plasma discharges, a unique high-speed dual Langmuir probe (HDLP) has been developed. A traditional single Langmuir probe of cylindrical geometry (exposed to the plasma) is swept simultaneously with a nearby capacitance and noise compensating null probe (fully insulated from the plasma) to enable bias sweep rates on a microsecond timescale. Traditional thin-sheath Langmuir probe theory is applied for interpretation of the collected probe data. Data at a sweep rate of 100 kHz are presented; however the developed system is capable of running at 1 MHz--near the upper limit of the applied electrostatic Langmuir probe theory for the investigated plasma conditions. Large sets (100 000 sweeps at each of 352 spatial locations) of contiguous turbulent plasma properties are collected using simple electronics for probe bias driving and current measurement attaining 80 dB signal-to-noise measurements with dc to 1 MHz bandwidth. Near- and far-field plume measurements with the HDLP system are performed downstream from a modern Hall effect thruster where the time-averaged plasma properties exhibit the approximate ranges: electron density n{sub e} from (1x10{sup 15})-(5x10{sup 16}) m{sup -3}, electron temperature T{sub e} from 1 to 3.5 eV, and plasma potential V{sub p} from 5 to 15 V. The thruster discharge of 200 V (constant anode potential) and 2 A (average discharge current) displays strong, 2.2 A peak-to-peak, current oscillations at 19 kHz, characteristic of the thruster ''breathing mode'' ionization instability. Large amplitude discharge current fluctuations are typical for most Hall thrusters, yet the HDLP system reveals the presence of the same 19 kHz fluctuations in n{sub e}(t), T{sub e}(t), and V{sub p}(t) throughout the entire plume with peak-to-peak divided by mean plasma properties that average 94%. The propagation delays between the discharge current fluctuations and the corresponding plasma density fluctuations agree well with expected ion transit-times observed with distinct plasma waves traveling away from the thruster at velocities >10 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A restoration model of distorted electron density in wave-cutoff probe measurement

This study investigates the problem of electron density distortion and how the density can be restored in a wave-cutoff probe. Despite recent plasma diagnostics research using a wave-cutoff probe, the problem of electron density distortion caused by plasma conditions has not been resolved. Experimental results indicate that electron density measured using the wave-cutoff method is highly susceptible to variations in the probe tip gap. This electron density distortion is caused by the bulk plasma disturbance between probe tips, and it must be removed for calculating the absolute electron density. To do this, a detailed analytic model was developed using the power balance equation near probe tips. This model demonstrates the characteristics of plasma distortion in wave-cutoff probe measurement and successfully restored the absolute value of electron density with varying probe tip gaps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density dependence of impedance probe plasma potential measurements

In earlier works, we used spheres of various sizes as impedance probes in demonstrating a method of determining plasma potential, φ{sub p}, when the probe radius is much larger than the Debye length, λ{sub D}. The basis of the method in those works [Walker et al., Phys. Plasmas 13, 032108 (2006); ibid. 15, 123506 (2008); ibid. 17, 113503 (2010)] relies on applying a small amplitude signal of fixed frequency to a probe in a plasma and, through network analyzer-based measurements, determining the complex reflection coefficient, Γ, for varying probe bias, V{sub b}. The frequency range of the applied signal is restricted to avoid sheath resonant effects and ion contributions such that ω{sub pi} ≪ ω ≪ ω{sub pe}, where ω{sub pi} is the ion plasma frequency and ω{sub pe} is the electron plasma frequency. For a given frequency and applied bias, both Re(Z{sub ac}) and Im(Z{sub ac}) are available from Γ. When Re(Z{sub ac}) is plotted versus V{sub b}, a minimum predicted by theory occurs at φ{sub p} [Walker et al., Phys. Plasmas 17, 113503 (2010)]. In addition, Im(Z{sub ac}) appears at, or very near, a maximum at φ{sub p}. As n{sub e} decreases and the sheath expands, the minimum becomes harder to discern. The purpose of this work is to demonstrate that when using network analyzer-based measurements, Γ itself and Im(Z{sub ac}) and their derivatives are useful as accompanying indicators to Re(Z{sub ac}) in these difficult cases. We note the difficulties encountered by the most commonly used plasma diagnostic, the Langmuir probe. Spherical probe data is mainly used in this work, although we present limited data for a cylinder and a disk. To demonstrate the effect of lowered density as a function of probe geometry, we compare the cylinder and disk using only the indicator Re(Z{sub ac})

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-invasive probe diagnostic method for electron temperature and ion current density in atmospheric pressure plasma jet source

The electrical probe diagnostics are very hard to be applied to atmospheric plasmas due to severe perturbation by the electrical probes. To overcome this, the probe for measuring electron temperature and ion current density is indirectly contacted with an atmospheric jet source. The plasma parameters are obtained by using floating harmonic analysis. The probe is mounted on the quartz tube that surrounds plasma. When a sinusoidal voltage is applied to a probe contacting on a quartz tube, the electrons near the sheath at dielectric tube are collected and the probe current has harmonic components due to probe sheath nonlinearity. From the relation of the harmonic currents and amplitude of the sheath voltage, the electron temperature near the wall can be obtained with collisional sheath model. The electron temperatures and ion current densities measured at the discharge region are in the ranges of 2.7–3.4 eV and 1.7–5.2 mA/cm{sup 2} at various flow rates and input powers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contact resonances of U-shaped atomic force microscope probes

Recent approaches used to characterize the elastic or viscoelastic properties of materials with nanoscale resolution have focused on the contact resonances of atomic force microscope (CR-AFM) probes. The experiments for these CR-AFM methods involve measurement of several contact resonances from which the resonant frequency and peak width are found. The contact resonance values are then compared with the noncontact values in order for the sample properties to be evaluated. The data analysis requires vibration models associated with the probe during contact in order for the beam response to be deconvolved from the measured spectra. To date, the majority of CR-AFM research has used rectangular probes that have a relatively simple vibration response. Recently, U-shaped AFM probes have created much interest because they allow local sample heating. However, the vibration response of these probes is much more complex such that CR-AFM is still in its infancy. In this article, a simplified analytical model of U-shaped probes is evaluated for contact resonance applications relative to a more complex finite element (FE) computational model. The tip-sample contact is modeled using three orthogonal Kelvin-Voigt elements such that the resonant frequency and peak width of each mode are functions of the contact conditions. For the purely elastic case, the frequency results of the simple model are within 8% of the FE model for the lowest six modes over a wide range of contact stiffness values. Results for the viscoelastic contact problem for which the quality factor of the lowest six modes is compared show agreement to within 13%. These results suggest that this simple model can be used effectively to evaluate CR-AFM experimental results during AFM scanning such that quantitative mapping of viscoelastic properties may be possible using U-shaped probes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A versatile rotary-stage high frequency probe station for studying magnetic films and devices

We present a rotary-stage microwave probe station suitable for magnetic films and spintronic devices. Two stages, one for field rotation from parallel to perpendicular to the sample plane (out-of-plane) and the other intended for field rotation within the sample plane (in-plane) have been designed. The sample probes and micro-positioners are rotated simultaneously with the stages, which allows the field orientation to cover θ from 0{sup ∘} to 90{sup ∘} and φ from 0{sup ∘} to 360{sup ∘}. θ and φ being the angle between the direction of current flow and field in a out-of-plane and an in-plane rotation, respectively. The operation frequency is up to 40 GHz and the magnetic field up to 1 T. The sample holder vision system and probe assembly are compactly designed for the probes to land on a wafer with diameter up to 3 cm. Using homemade multi-pin probes and commercially available high frequency probes, several applications including 4-probe DC measurements, the determination of domain wall velocity, and spin transfer torque ferromagnetic resonance are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specialized whisker probes for nanodiagnostics

A short review of specialized probes for nanodiagnostics with an accent to using for this aim of silicon whisker tip probes prepared by crystal growing from vapor phase. The probes ensure significant advantages in comparison with the standard probes that are produced by etching single-crystalline silicon wafers. Whisker probes for chemical force microscopy and for biological force microscopy are considered; their development for new versions, 'single-molecule force microscopy' has been noted. Possibilities of the whisker probes for magnetic force microscopy and its new version, so-called 'nano cluster magnetic force microscopy' that can be useful at chemical design on nanosized high-spin molecules are analyzed. Possibilities of the whisker probes for improvement of resolution and sensitivity of the capacity force microscopy for investigations in impurity distribution in semiconductor crystals and films are considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-Vendor and Cross-State Analysis of GPS Probe Data Latency

Crowd sourced GPS probe data have become a major source of real-time traffic information applications. In addition to traditional traveler advisory systems such as dynamic message signs (DMS) and 511 systems, probe data are being used for automatic incident detection, integrated corridor management (ICM), end of queue warning systems, and mobility-related smartphone applications. Several private sector vendors offer minute by minute network-wide travel time and speed probe data. The quality of such data in terms of deviation of the reported travel time and speeds from ground-truth has been extensively studied in recent years, and as a result concerns over the accuracy of probe data have mostly faded away. However, the latency of probe data - defined as the lag between the time at which disturbance in traffic speed is reported in the outsourced data feed, and the time at which the traffic is perturbed - has become a subject of interest. The extent of latency of probe data for real-time applications is critical, so it is important to have a good understanding of the amount of latency and its influencing factors. This paper uses high-quality independent Bluetooth/Wi-Fi re-identification data collected on multiple freeway segments in three different states, to measure the latency of the vehicle probe data provided by three major vendors. The statistical distribution of the latency and its sensitivity to speed slowdown and recovery periods are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Validation of DNA probes for molecular cytogenetics by mapping onto immobilized circular DNA

Fluorescence in situ hybridization (FISH) is a sensitive and rapid procedure to detect gene rearrangements in tumor cells using non-isotopically labeled DNA probes. Large insert recombinant DNA clones such as bacterial artificial chromosome (BAC) or P1/PAC clones have established themselves in recent years as preferred starting material for probe preparations due to their low rates of chimerism and ease of use. However, when developing probes for the quantitative analysis of rearrangements involving genomic intervals of less than 100kb, careful probe selection and characterization are of paramount importance. We describe a sensitive approach to quality control probe clones suspected of carrying deletions or for measuring clone overlap with near kilobase resolution. The method takes advantage of the fact that P1/PAC/BAC's can be isolated as circular DNA molecules, stretched out on glass slides and fine-mapped by multicolor hybridization with smaller probe molecules. Two examples demonstrate the application of this technique: mapping of a gene-specific {approx}6kb plasmid onto an unusually small, {approx}55kb circular P1 molecule and the determination of the extent of overlap between P1 molecules homologous to the human NF-?B2 locus. The relatively simple method presented here does not require specialized equipment and may thus find widespread applications in DNA probe preparation and characterization, the assembly of physical maps for model organisms or in studies on gene rearrangements.

47 OTHER INSTRUMENTATION↗

FY16 Status of Immersion Phased Array Ultrasonic Probe Development and Performance Demonstration Results for Under Sodium Viewing

This section of the Joint summary technical letter report (TLR) describes work conducted at the Pacific Northwest National Laboratory (PNNL) during FY 2016 (FY16) on the under-sodium viewing (USV) PNNL project 58745, work package AT-16PN230102. This section of the TLR satisfies PNNL’s M3AT-16PN2301025 milestone and is focused on summarizing the design, development, and evaluation of two different phased-array ultrasonic testing (PA-UT) probe designs—a two-dimensional (2D) matrix phased-array probe, and two one-dimensional (1D) linear array probes, referred to as serial number 4 (SN4) engineering test units (ETUs). The 2D probe is a pulse-echo (PE), 32×2, 64-element matrix phased-array ETU. The 1D probes are 32×1 element linear array ETUs. This TLR also provides the results from a performance demonstration (PD) of in-sodium target detection trials at 260°C using both probe designs. This effort continues the iterative evolution supporting the longer term goal of producing and demonstrating a pre-manufacturing prototype ultrasonic probe that possesses the fundamental performance characteristics necessary to enable the development of a high-temperature sodium-cooled fast reactor (SFR) inspection system for in-sodium detection and imaging.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Overview of Key Saturn Probe Mission Trades

Ongoing studies, performed at NASA/JPL over the past two years in support of NASA's SSE Roadmap activities, proved the feasibility of a NF class Saturn probe mission. I. This proposed mission could also provide a good opportunity for international collaboration with the proposed Cosmic Vision KRONOS mission: a) With ESA contributed probes (descent modules) on a NASA lead mission; b) Early 2017 launch could be a good programmatic option for ESA-CV/NASA-NF. II. A number of mission architectures could be suitable for this mission: a) Probe Relay based architecture with short flight time (approx. 6.3-7 years); b) DTE probe telecom based architecture with long flight time (-11 years), and low probe data rate, but with the probes decoupled from the carrier, allowing for polar trajectories I orbiter. This option may need technology development for telecom; c) Orbiter would likely impact mission cost over flyby, but would provide significantly higher science return. The Saturn probes mission is expected to be identified in NASA's New Frontiers AO. Thus, further studies are recommended to refine the most suitable architecture. International collaboration is started through the KRONOS proposal work; further collaborated studies will follow once KRONOS is selected in October under ESA's Cosmic Vision Program.

probes↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10-5 for the non-dimensional total pressure and 2.88 x 10-5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10 -5 for the non-dimensional total pressure and 2.88 x 10 -5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Wind Tunnel Test of A Scale Model of A Venus Probe to Determine Aeroacoustics Environment

The Zephyr probe for NASA’s DAVINCI project is being designed to fly to Venus and collect measurements to characterize the Venusian atmosphere while it descends towards the surface. Despite a slow descent speed as the probe approaches the surface, the very dense atmosphere means the vibro-acoustic environment that the probe must withstand could be very harsh. A wind tunnel test campaign was conducted to characterize the surface-pressure fluctuations (acoustics) on the external surface of the probe during the descent. The goal was to provide forcing functions for vibro-acoustic analysis of all instruments inside the probe. A 25% scale-model of the Zephyr probe was manufactured, instrumented with 18 microphones, and tested in two wind tunnels located in the Fluid Mechanics Lab at NASA Ames Research Center at velocities ranging from 13 m/s to 48 m/s. Trip strips were added to the model to ensure a turbulent boundary layer on the model. Microphones were located appropriately to provide spectra of pressure fluctuations in regions with different flow characteristics as well as for calculating various two-point statistics. The acoustic spectra measured in the wind tunnel tests were scaled up to flight-scale using the estimated flight trajectory information. Besides fluctuating surface-pressure measurements, hot-film velocity measurements as well as smoke-laser flow visualization were conducted to better understand the flow around the probe. Lastly, several different geometry configurations were tested to see whether any reduction in acoustic levels could be achieved, but none of the configurations that were tested offered significant improvements. The flow visualization showed 3 primary flow regimes on the model: an attached turbulent boundary layer on the front of the model, a region of separated flow upstream of the flared lip, and a large, separated wake at the rear of the model. The acoustic spectra generally show three different shapes corresponding to these flow regions, with the highest levels seen at the rear of the model, and directly in front of the drag plate. The scaled overall levels of pressure fluctuations were found to be high: in the range of 130dB to 155dB.

planetary probe↗

Plastic deformation and material transfer on steel gage blocks during low force mechanical probing

Contact probing of gaging surfaces is enabled throughout dimensional metrology. Probe tips such as ruby, sapphire, or diamond are commonly employed as styli for universal length measuring machines (ULMs) and coordinate measuring machines (CMMs) due to the hardness, durability, and wear resistance. Gaging surfaces of gage blocks are precision ground or lapped, with very low surface roughness to enable wringing. Damage or contamination of these surfaces can prevent wringing and lead to measurement error. Experimental investigations using a horizontal ULM and CMM have revealed that even at low force settings (≤0.16 N), probe materials such as ruby and sapphire can cause plastic deformation to hardened carbon chrome steel (such as AISI 52,100) gage block surfaces at the microscale, likely attributed to fretting-associated wear. Under some conditions, permanent transfer of material from the probe stylus to the gaging surface is possible. Results show irreversible changes and damage to gaging surfaces with repeated probe contact on a ULM and CMM. Optical microscopy, optical profilometry, and scanning electron microscopy (SEM) provide a semi-quantitative assessment of microscale plastic deformation and material transfer. X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and Raman techniques validate chemical constituency of reference materials used (gage blocks and probes) and also identify makeup of deposits on gaging surfaces following probe contact.

42 ENGINEERING↗