Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORMANCE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High temperature NASP engine seal development

Key to the development of advanced hypersonic engines such as those being considered for the National Aerospace Plane (NASP) is the development and evaluation of high temperature, flexible seals that must seal the many feet of gaps between the articulating and stationary engine panels. Recent seal progress made at NASA-Lewis is reviewed in the areas of seal concept maturation, test rig development, and performance tests. A test fixture was built at NASA capable of subjecting candidate 3 ft long seals to engine simulated temperatures (up to 1500 F), pressures (up to 100 psi), and engine wall distortions (up to 0.15 in only 18 in span). Leakage performance test results at high temperatures are presented for an innovative high temperature, flexible ceramic wafer seal. Also described is a joint Pratt and Whitney/NASA planned test program to evaluate thermal performance of a braided rope seal under engine simulated heat flux rates (up to 400 Btu/sq ft s), and supersonic flow conditions. These conditions are produced by subjecting the seal specimen to hydrogen oxygen rocket exhaust that flows tangent to the specimen.

Steinetz, Bruce M.↗

In-Situ Testing and Performance Assessment of a Redesigned WIPP Panel Closure - 13192

There are two primary regulatory requirements for Panel Closures at the Waste Isolation Pilot Plant (WIPP), the nation's only deep geologic repository for defense related Transuranic (TRU) and Mixed TRU waste. The Federal requirement is through 40 CFR 191 and 194, promulgated by the U.S. Environmental Protection Agency (EPA). The state requirement is regulated through the authority of the Secretary of the New Mexico Environment Department (NMED) under the New Mexico Hazardous Waste Act (HWA), New Mexico Statutes Annotated (NMSA) 1978, chap. 74-4-1 through 74-4-14, in accordance with the New Mexico Hazardous Waste Management Regulations (HWMR), 20.4.1 New Mexico Annotated Code (NMAC). The state regulations are implemented for the operational period of waste emplacement plus 30 years whereas the federal requirements are implemented from the operational period through 10,000 years. The 10,000 year federal requirement is related to the adequate representation of the panel closures in determining long-term performance of the repository. In Condition 1 of the Final Certification Rulemaking for 40 CFR Part 194, the EPA required a specific design for the panel closure system. The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) has requested, through the Planned Change Request (PCR) process, that the EPA modify Condition 1 via its rulemaking process. The DOE has also requested, through the Permit Modification Request (PMR) process, that the NMED modify the approved panel closure system specified in Permit Attachment G1. The WIPP facility is carved out of a bedded salt formation 655 meters below the surface of southeast New Mexico. Condition 1 of the Final Certification Rulemaking specifies that the waste panels be closed using Option D which is a combination of a Salado mass concrete (SMC) monolith and an isolation/explosion block wall. The Option D design was also accepted as the panel closure of choice by the NMED. After twelve years of waste handling operations and a greater understanding of the waste and the behavior of the underground salt formation, the DOE has established a revised panel closure design. This revised design meets both the short-term NMED Permit requirements for the operational period, and also the Federal requirements for long-term repository performance. This new design is simpler, easier to construct and has less of an adverse impact on waste disposal operations than the originally approved Option D design. The Panel Closure Redesign is based on: (1) the results of in-situ constructability testing performed to determine run-of-mine salt reconsolidation parameters and how the characteristics of the bedded salt formation affect these parameters and, (2) the results of air flow analysis of the new design to determine that the limit for the migration of Volatile Organic Compounds (VOCs) will be met at the compliance point. Waste panel closures comprise a repository feature that has been represented in WIPP performance assessment (PA) since the original Compliance Certification Application of 1996. Panel closures are included in WIPP PA models principally because they are a part of the disposal system, not because they play a substantive role in inhibiting the release of radionuclides to the outside environment. The 1998 rulemaking that certified WIPP to receive transuranic waste placed conditions on the panel closure design to be implemented in the repository. The revised panel closure design, termed the Run-of-Mine (ROM) Panel Closure System (ROMPCS), is comprised of 30.48 meters of ROM salt with barriers at each end. The ROM salt is generated from ongoing mining operations at the WIPP and may be compacted and/or moistened as it is emplaced in a panel entry. The barriers consist of bulkheads, similar to those currently used in the panels as room closures. A WIPP performance assessment has been completed that incorporates the ROMPCS design into the representation of the repository, and compares repository performance to that achieved with the approved Option D design. Several key physical processes and rock mechanics principles are incorporated into the performance assessment. First, creep closure of the salt rock surrounding a panel entry results in consolidation of the ROM salt emplaced in the entry. Eventually, the ROM salt comprising the ROMPCS will approach a condition similar to intact salt. As the ROM salt reaches higher fractional densities during consolidation, back stress will be imposed on the surrounding rock mass leading to eventual healing of the disturbed rock zone above and below the panel closure. Healing of the disturbed rock zone above and below the ROMPCS reduces the porosity and permeability in those areas. Analysis of the new design demonstrates that: (1) the WIPP continues to meet regulatory compliance requirements when the ROMPCS design is implemented instead of Option D, and (2) there is no impact on the short-term effectiveness of the panel closure to limit the concentration of VOCs at the WIPP site boundary to a fraction of the health-based exposure limits (HBLs) during the operational period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerodynamic Simulation of Runback Ice Accretion

This report presents the results of recent investigations into the aerodynamics of simulated runback ice accretion on airfoils. Aerodynamic tests were performed on a full-scale model using a high-fidelity, ice-casting simulation at near-flight Reynolds (Re) number. The ice-casting simulation was attached to the leading edge of a 72-in. (1828.8-mm ) chord NACA 23012 airfoil model. Aerodynamic performance tests were conducted at the ONERA F1 pressurized wind tunnel over a Reynolds number range of 4.7?10(exp 6) to 16.0?10(exp 6) and a Mach (M) number ran ge of 0.10 to 0.28. For Re = 16.0?10(exp 6) and M = 0.20, the simulated runback ice accretion on the airfoil decreased the maximum lift coe fficient from 1.82 to 1.51 and decreased the stalling angle of attack from 18.1deg to 15.0deg. The pitching-moment slope was also increased and the drag coefficient was increased by more than a factor of two. In general, the performance effects were insensitive to Reynolds numb er and Mach number changes over the range tested. Follow-on, subscale aerodynamic tests were conducted on a quarter-scale NACA 23012 model (18-in. (457.2-mm) chord) at Re = 1.8?10(exp 6) and M = 0.18, using low-fidelity, geometrically scaled simulations of the full-scale castin g. It was found that simple, two-dimensional simulations of the upper- and lower-surface runback ridges provided the best representation of the full-scale, high Reynolds number iced-airfoil aerodynamics, whereas higher-fidelity simulations resulted in larger performance degrada tions. The experimental results were used to define a new subclassification of spanwise ridge ice that distinguishes between short and tall ridges. This subclassification is based upon the flow field and resulting aerodynamic characteristics, regardless of the physical size of the ridge and the ice-accretion mechanism.

Broeren, Andy P.↗

Conceptual Design of Forced Convection Molten Salt Heat Transfer Testing Loop

This report develops a proposal to design and construct a forced convection test loop. A detailed test plan will then be conducted to obtain data on heat transfer, thermodynamic, and corrosion characteristics of the molten salts and fluid-solid interaction. In particular, this report outlines an experimental research and development test plan. The most important initial requirement for heat transfer test of molten salt systems is the establishment of reference coolant materials to use in the experiments. An earlier report produced within the same project highlighted how thermophysical properties of the materials that directly impact the heat transfer behavior are strongly correlated to the composition and impurities concentration of the melt. It is therefore essential to establish laboratory techniques that can measure the melt composition, and to develop purification methods that would allow the production of large quantities of coolant with the desired purity. A companion report describes the options available to reach such objectives. In particular, that report outlines an experimental research and development test plan that would include following steps: •Molten Salts: The candidate molten salts for investigation will be selected. •Materials of Construction: Materials of construction for the test loop, heat exchangers, and fluid-solid corrosion tests in the test loop will also be selected. •Scaling Analysis: Scaling analysis to design the test loop will be performed. •Test Plan: A comprehensive test plan to include all the tests that are being planned in the short and long term time frame will be developed. •Design the Test Loop: The forced convection test loop will be designed including extensive mechanical design, instrument selection, data acquisition system, safety requirements, and related precautionary measures. •Fabricate the Test Loop. •Perform the Tests. •Uncertainty Analysis: As a part of the data collection, uncertainty analysis will be performed to develop probability of confidence in what is measured in the test loop. Overall, the testing loop will allow development of needed heat transfer related thermophysical parameters for all the salts, validate existing correlations, validate measuring instruments under harsh environment, and have extensive corrosion testing of materials of construction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NUCON Vapor Abatement Unit Performance on Hanford Tank Farm Chemicals of Potential Concern

This report provided the results and methods used in the NUCON Vapor Abatement Unit performance testing. The purpose of the Pacific Northwest National Laboratory (PNNL) testing was to assess the performance of the NUCON International, Inc., Vapor Abatement Unit (VAU) prototype for the reduction of Hanford Tank Farm vapors associated chemicals of potential concern (COPC). The testing was conducted in compliance with the PNNL Assessment of NUCON Vapor Abatement Unit for Single-Shell Tank (SST) Farm Off-Gas Chemicals of Potential Concern (COPCs) test plan. Performance testing started on May 4, 2018 and continued through June 13, 2018. Eleven (11) COPCs were chosen for testing out of the 61 identified COPCs. The COPCs were chosen either due to the importance of that COPC measured in Hanford high-level waste single-shell tank (SST) vapor emissions, as a surrogate to represent a class of COPC compounds, or both. Results of the performance tests are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing and Performance Analysis of the Multichannel Error Correction Code Decoder

This report provides the test results and performance analysis of the multichannel error correction code decoder (MED) system for a regenerative satellite with asynchronous, frequency-division multiple access (FDMA) uplink channels. It discusses the system performance relative to various critical parameters: the coding length, data pattern, unique word value, unique word threshold, and adjacent-channel interference. Testing was performed under laboratory conditions and used a computer control interface with specifically developed control software to vary these parameters. Needed technologies - the high-speed Bose Chaudhuri-Hocquenghem (BCH) codec from Harris Corporation and the TRW multichannel demultiplexer/demodulator (MCDD) - were fully integrated into the mesh very small aperture terminal (VSAT) onboard processing architecture and were demonstrated.

Soni, Nitin J.↗

Gasification of Mixed Blends of Coal, Biomass, and Plastic Waste

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI. The technical tasks for this research project included: • Feed Procurement and Preparation: Nine different feedstocks were prepared from varying compositions of PRB coal, corn stover biomass, and car fluff waste plastics. Fuel pellets were produced by California Pellet Mill (CPM) and shipped to Sotacarbo’s test facility in Italy. • Test Plan Development: A test plan was created to define the test runs to be performed. The test plan detailed the different tests that were run, instrumentation used, extractive samples taken, and relevant figures of merit. • Gasifier Testing: Tests were performed in the pilot-scale gasifier at Sotacarbo using nine different fuel feedstocks generated from varying mixtures of coal, biomass, and plastic wastes. The testing provides information on gasification reaction efficiency/performance, yielding relevant data for models used to scale up the gasifier design. This task will also included work to reassemble the gasifier at Sotacarbo and perform a baseline 100% coal run. • Data Analysis and Reporting: Review of the data, determination of figures of merit, and interpretation of the results was reported. The results can be used to specify the range of feedstock blends that can be successfully gasified as well as quantify gasifier outputs based on specific blends. The tri-fuel pelletizing conducted at CPM and gasification testing results from Sotacarbo’s 30mm up draft moving bed gasifier are significant. Providing data for an established gasifier to help accelerate its updated design to be able to accommodate feedstocks composed of coal, biomass, and plastic waste. This should ultimately lead to development and commercialization of a lower cost, white hydrogen generation system.

01 COAL, LIGNITE, AND PEAT↗

DWPF SIMULANT CPC STUDIES FOR SB7B

Lab-scale DWPF simulations of Sludge Batch 7b (SB7b) processing were performed. Testing was performed at the Savannah River National Laboratory - Aiken County Technology Laboratory (SRNL-ACTL). The primary goal of the simulations was to define a likely operating window for acid stoichiometry for the DWPF Sludge Receipt and Adjustment Tank (SRAT). In addition, the testing established conditions for the SRNL Shielded Cells qualification simulation of SB7b-Tank 40 blend, supported validation of the current glass redox model, and validated the coupled process flowsheet at the nominal acid stoichiometry. An acid window of 105-140% by the Koopman minimum acid (KMA) equation (107-142% DWPF Hsu equation) worked for the sludge-only flowsheet. Nitrite was present in the SRAT product for the 105% KMA run at 366 mg/kg, while SME cycle hydrogen reached 94% of the DWPF Slurry Mix Evaporator (SME) cycle limit in the 140% KMA run. The window was determined for sludge with added caustic (0.28M additional base, or roughly 12,000 gallons 50% NaOH to 820,000 gallons waste slurry). A suitable processing window appears to be 107-130% DWPF acid equation for sludge-only processing allowing some conservatism for the mapping of lab-scale simulant data to full-scale real waste processing including potentially non-conservative noble metal and mercury concentrations. This window should be usable with or without the addition of up to 7,000 gallons of caustic to the batch. The window could potentially be wider if caustic is not added to SB7b. It is recommended that DWPF begin processing SB7b at 115% stoichiometry using the current DWPF equation. The factor could be increased if necessary, but changes should be made with caution and in small increments. DWPF should not concentrate past 48 wt.% total solids in the SME cycle if moderate hydrogen generation is occurring simultaneously. The coupled flowsheet simulation made more hydrogen in the SRAT and SME cycles than the sludge-only run with the same acid stoichiometric factor. The slow acid addition in MCU seemed to alter the reactions that consumed the small excess acid present such that hydrogen generation was promoted relative to sludge-only processing. The coupled test reached higher wt.% total solids, and this likely contributed to the SME cycle hydrogen limit being exceeded at 110% KMA. It is clear from the trends in the SME processing GC data, however, that the frit slurry formic acid contributed to driving the hydrogen generation rate above the SME cycle limit. Hydrogen generation rates after the second frit addition generally exceeded those after the first frit addition. SRAT formate loss increased with increasing acid stoichiometry (15% to 35%). A substantial nitrate gain which was observed to have occurred after acid addition (and nitrite destruction) was reversed to a net nitrate loss in runs with higher acid stoichiometry (nitrate in SRAT product less than sum of sludge nitrate and added nitric acid). Increased ammonium ion formation was also indicated in the runs with nitrate loss. Oxalate loss on the order 20% was indicated in three of the four acid stoichiometry runs and in the coupled flowsheet run. The minimum acid stoichiometry run had no indicated loss. The losses were of the same order as the official analytical uncertainty of the oxalate concentration measurement, but were not randomly distributed about zero loss, so some actual loss was likely occurring. Based on the entire set of SB7b test data, it is recommended that DWPF avoid concentrating additional sludge solids in single SRAT batches to limit the concentrations of noble metals to SB7a processing levels (on a grams noble metal per SRAT batch basis). It is also recommended that DWPF drop the formic acid addition that accompanies the process frit 418 additions, since SME cycle data showed considerable catalytic activity for hydrogen generation from this additional acid (about 5% increase in stoichiometry occurred from the frit formic acid). Frit 418 also does not appear to need formic acid addition to prevent gel formation in the frit slurry. Simulant processing was successful using 100 ppm of 747 antifoam added prior to nitric acid instead of 200 ppm. This is a potential area for DWPF to cut antifoam usage in any future test program. An additional 100 ppm was added before formic acid addition. Foaming during formic acid addition was not observed. No build-up of oily or waxy material was observed in the off-gas equipment. Lab-scale mercury stripping behavior was similar to SB6 and SB7a. More mercury was unaccounted for as the acid stoichiometry increased.

08 HYDROGEN↗

Defect Measurements of CdZnTe Detectors Using I-DLTS, TCT, I-V and Gamma-ray Spectroscopy

In this work we measured the crystal defect levels and tested the performance of CdZnTe detectors by diverse methodologies, viz., Current Deep Level Transient Spectroscopy (I-DLTS), Transient Current Technique (TCT), Current and Capacitance versus Voltage measurements (I-V and C-V), and gamma-ray spectroscopy. Two important characteristics of I-DLTS technique for advancing this research are (1) it is applicable for high-resistivity materials (>10{sup 6} {Omega}-cm), and, (2) the minimum temperature for measurements can be as low as 10 K. Such low-temperature capability is excellent for obtaining measurements at shallow levels. We acquired CdZnTe crystals grown by different techniques from two different vendors and characterized them for point defects and their response to photons. I-DLTS studies encompassed measuring the parameters of the defects, such as the energy levels in the band gap, the carrier capture cross-sections and their densities. The current induced by the laser-generated carriers and the charge collected (or number of electrons collected) were obtained using TCT that also provides the transport properties, such as the carrier life time and mobility of the detectors under study. The detector's electrical characteristics were explored, and its performance tested using I-V, C-V and gamma-ray spectroscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long Term Performance Retention Test Using High Power COTS NiCd and NiMH Cells

This slide presentation reviews the tests and results for performance retention of high powered commercial off the shelf (COTS) NiCd, and NiMH cells. Electromechanical actuators for space flight requires short duration high power batteries. The concern is that NiCd battery designs demonstrate an unfavorable power degradation after long periods of inactivity. Cycling can recover some of the decay, but this reduces the readiness that these batteries must have. Two 5-cell SubC stick test batteries ere chosen using NiCd and NiMH were tested and then the differences for charge maintenance were compared.

Hall, Dan↗

Current Activities in the Advanced Exploration Systems ISRU Project

Media Filter MOXIE support: completed flow performance tests and initial dust loading tests of the MOXIE HEPA filter in the Mars Flow Loop Designed and fabricated prototype full-scale scroll filter for testing of renewable filter performance Mars Flow Loop upgrades: installed more sensitive instrumentation, improved imaging, and increased run duration capability Electrostatic Precipitator (ESP) Plasma-physics based model predicts particle charge and trajectory Characterizing dust environment from fluidized-bed injection dust environment using laser sheet visualization and Fine Particle Analyzer Sabatier Design Study Defined the Sabatier design space, including reactor type, thermal management, gas recycling/separation Modeled Sabatier systems with one or two reactors with different types of thermal management Adding thermal management schemes and recycling and gas separation to model Catalyst Screening Performing compression testing on new and used catalyst pellets Performing vibration testing on different catalyst pellet types under different load conditions Preparing to test catalysts for performance and degradation

In-Situ Resource Utilization↗

A Novel Lithium-ion Laminated Pouch Cell Tested For Performance And Safety

A new Li-ion 4.0 Ah pouch cell from GS Yuasa has been tested to determine its performance and safety. The cell is of a laminate pouch design with liquid electrolyte. The rate, thermal and vacuum performance capabilities have been tested to determine the optimum parameters. Under vacuum conditions, the cells were cycled under restrained and unrestrained configurations. The burst pressure of the laminate pouch was also determined. The overcharge, overdischarge into reversal and external short circuit safety tests were also performed to determine the cell s tolerance to abuse. Key Words: Li-ion, safety, vacuum test, abuse, COTS batteries, rate capability

Jeevarajan, Judith A.↗

Advanced Hydrogen Fueling Station Supply: Tube Trailers

Air Products and Chemicals, Inc. (Air Products) is reporting on the results of a DOE-funded program to develop and validate Advanced Hydrogen Fueling Station hydrogen tube trailers to support hydrogen and fuel cell market applications. The project involved the engineering design and development of a new composite over-wrapped pressure vessel to increase the pressure capability of tube trailers to deliver hydrogen to greater than 8500 psi (586 bar). The new composite over-wrapped pressure vessel tube trailer was expected to provide improved delivery technology and reduce the cost of transporting hydrogen from central hydrogen production sources. The project aimed to meet or exceed DOE’s 2020 delivery targets for tube trailer hydrogen distribution. A gated approach was taken for the project, with early project Go/No-Go decision points. Specific goals for this four-stage product development project included: Preliminary Study, Modeling, and Analysis: Complete a preliminary design analysis and cost viability of a >8500 psi (586 bar) hydrogen storage vessel with an appropriate frame and chassis configuration for a complete trailer to US DOT requirements; Develop New Tube Size for >8500 psi (586 bar) Vessel: Fabricate tubes for test units, perform testing, and submit test results for a DOT Special Permit; Design, fabricate, and test a delivery trailer unit; Deploy the delivery trailer to hydrogen stations and collect data. Work conducted under DE-EE0006524 established costs for US DOT Type III vessels at 8500 psi (586 bar), 12500 psi (862 bar), and 14000 psi (965 bar) with manufactured water volumes up to 375 liters. Trailer module designs were established for the maximum US DOT design limits and for Air Products’ design limit of a 40-foot trailer length that addresses California hydrogen fueling station ingress and egress operating constraints. Conceptual trailer designs were not capable of achieving the DOE 2020 capacity and cost targets, but they did exceed the DOE pressure target of 500 bar. Based on new trailer cost and simulated operating performance, the 8500 psi (586 bar) new trailer design is not feasible in comparison to Air Products’ DOT-approved 7500 psi (520 bar) trailer design in operation today. Also, the project was expected to incur significantly higher product development costs associated with new US DOT vessel development and approval. Alternative trailer design concepts were explored that included 700 bar compression-less mobile fueling that could be promising for early-market hydrogen infrastructure fueling station placement and development and niche military applications. Due to the economic and budget challenges identified in the feasibility phase of the program, Air Products, in agreement with the Department of Energy, decided to terminate this development program.

08 HYDROGEN↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FFTF main heat transport system/dump heat exchanger testing and performance evaluation (initial pub date April 1978)

This report covers testing of a Main Heat Transport System/Dump Heat Exchanger (MHTS/DHX) for the Fast Flux Test Facility. The primary objective of the test program was to verify the design and generate experience in the installation, operation, and control of the DHX for FFTF. This report discusses test results related to erection, preoperational testing, in-service inspections, and steady-state and transient performance. Emphasis is placed on the effect of the test results on successful DHX operation at FFTF. 36 figures, 9 tables.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Altus small button cell performance

Results of testing performed on Altus lithium thionyl chloride cells are presented. The test plan followed simulates the mine environment. It involves nondestructive testing, ruggedness testing and destructive testing. The nondestructive testing involves open circuit voltage measurements initially on all the cells, alternating current resistance measurements initially on all the cells and closed circuit voltage pulses, 20s on and 20s through 1000, 100, 10 and 1 ohms at temperatures of -54 to 71 C. The ruggedness testing involves low frequency vibration, high frequency vibration, and two-phase water entry shock at temperatures of -54, 25 and 71 C. It also involves thermal shock tests.

Freeman, C.↗

Commissioning and Testing of a new 4.5K Cold Box for JLab Cryogenic Test Facility

A new 4.5K cold box at Jefferson Lab (JLab) Cryogenic Test Facility (CTF) was recently installed and commissioned to upgrade the existing 4.5 K refrigeration system and work in parallel with the existing 4.5 K cold box. This new 4.5 K cold box is equipped with two turbo-expanders and, at its maximum capacity condition, it is expected to support at least 6.6 g/s of helium liquefaction or 650 W of refrigeration at 4.5 K. It can also handle up to 10 g/s 30 K return flow for 2 K refrigeration recovery that supports cryo-module and superconducting cavity testing. Performances of the cold box at its maximum capacity conditions as well as several other operating modes were tested for acceptance. Finally, we will briefly review the new 4.5 K cold box design features and discuss the commissioning and performance testing results.

42 ENGINEERING↗