Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICAL MODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Analysis of the crystal lattice instability for cage–cluster systems using the superatom model

We have investigated the lattice dynamics for a number of rare-earth hexaborides based on the superatom model within which the boron octahedron is substituted by one superatom with a mass equal to the mass of six boron atoms. Phenomenological models have been constructed for the acoustic and lowenergy optical phonon modes in RB{sub 6} (R = La, Gd, Tb, Dy) compounds. Using DyB{sub 6} as an example, we have studied the anomalous softening of longitudinal acoustic phonons in several crystallographic directions, an effect that is also typical of GdB{sub 6} and TbB{sub 6}. The softening of the acoustic branches is shown to be achieved through the introduction of negative interatomic force constants between rare-earth ions. We discuss the structural instability of hexaborides based on 4f elements, the role of valence instability in the lattice dynamics, and the influence of the number of f electrons on the degree of softening of phonon modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Power enhancement of burst-mode UV pulses using a doubly-resonant optical cavity

We report a doubly-resonant enhancement cavity (DREC) that can realize a simultaneous enhancement of two incoming laser beams at different wavelengths and different temporal structures. The double-resonance condition is theoretically analyzed and different DREC locking methods are experimentally investigated. Simultaneous locking of a Fabry-Perot cavity to both an infrared (IR, 1064 nm) and its frequency tripled ultraviolet (UV, 355 nm) pulses has been demonstrated by controlling the frequency difference between the two beams with a fiber optic frequency shifter. The DREC technique opens a new paradigm in the applications of optical cavities to power enhancement of burst-mode lasers with arbitrary macropulse width and repetition rate.

42 ENGINEERING↗

Utah FORGE: Neubrex Well 16B(78)-32 DAS Data - April, 2024

This dataset comprises Distributed Acoustic Sensing (DAS) data collected from the Utah FORGE monitoring well 16B(78)-32 (the producer well) during hydraulic fracture stimulation operations conducted in April 2024. The data were acquired continuously over the stimulation period at a temporal sampling rate of 10,000 Hz (10 kS/s) and a spatial resolution of approximately 3.35 feet (1.02109 meters). The measurements were captured using a Neubrex NBX-S4100 Time Gated Digital DAS interrogator unit connected to a single-mode fiber optic cable, which was permanently installed within the casing string. All recorded channels correspond to downhole segments of the fiber optic cable, from a measured depth (MD) of 5,369.35 feet to 10,352.11 feet. The DAS data reflect raw acoustic energy generated by physical processes within and surrounding the well during stimulation activities at wells 16A(78)-32 and 16B(78)-32. These data have potential applications in analyzing cross-well strain, far-field strain rates (including microseismic activity), induced seismicity, and seismic imaging. Metadata embedded in the attributes of the HDF5 files include detailed information on the measured depths of the channels, interrogation parameters, and other acquisition details. The dataset also includes a recording of a seminar held on September 19, 2024, where Neubrex's Chief Operating Officer presented insights into the data collection, analysis, and preliminary findings. The raw data files, stored in HDF5 format, are organized chronologically according to the recording intervals from April 9 to April 24, 2024, with each file corresponding to a 12-second recording interval.

15 GEOTHERMAL ENERGY↗

Sapphire substrate qubit-based detector for light dark matter search

Harnessing sub-eV energy excitations from light dark matter interaction with a target material is one of the challenges in exploring promising novel materials for dark matter searches. In polar materials like sapphire, dark matter interaction can excite sub-eV optical phonon modes. Furthermore, the anisotropy of sapphire crystal could provide a signature of daily modulation of the dark matter scattering rate, making it a promising target material. We plan to utilize superconducting qubits on a sapphire substrate to take advantage of the excitation of phonons, which scatter and further down-convert to lower-energy phonons. A good fraction of these phonons are expected to reach the qubit superconductor on the substrate and break Cooper pairs. Such a process can cause qubit decoherence, which can be measured using standard qubit readout protocol. In this talk, we describe our ongoing attempt to build such a prototype detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Qubit-Based Detector For Dark Matter Search And Radiation Studies

One of the challenges in exploring promising novel materials for dark matter searches is the detection of sub-eV energy excitations from light-dark matter interaction with a target material. Dark matter interaction can excite sub-eV optical phonon modes in polar materials like sapphire. We plan to utilize superconducting qubits on a sapphire substrate to study their response to energy deposition into the superconducting film and the substrate by irradiating them with photons and particles and also generating phonons in the chip. A fraction of the incident energy is expected to break Cooper pairs in the superconductor, releasing quasiparticles. As the quasiparticles tunnel across the Josephson junction, the charge parity of the qubit changes. The parity switching rate is proportional to the quasiparticle density in the qubit superconductor film and can be measured using standard qubit readout protocol. This presentation describes our ongoing attempt to build such a prototype detector.

Khatiwada, Rakshya↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Developing and Deploying Universal Diagnostic Platforms for One-Health Biosurveillance

ObjectiveOur goal is to develop deployable strategies for infectious disease diagnosis at the point-of-care that are applicable to multiple hosts of infection - conforming to the global One Health Strategy for diagnostics. We aim to develop methods that do not require prior knowledge of the pathogen in question, and can facilitate rapid and effective decision-making and situational awareness.IntroductionThere is an urgent need for diagnostic strategies for infections which are host-independent, so as to effectively track zoonotic spread, monitor animal carriers of pathogens, and evaluate transmission dynamics. Infection of a host - pathogen or human- by an animal results in recognition by the immune response, which consequently causes release of inflammatory mediators. Many scientists have explored the use of cytokines as diagnostic indicators of disease, but the conserved nature of the immune response in humans and animals results in cross-reactivity among many pathogens, making evaluation of the results difficult, especially in high disease burden populations. Measuring the pathogen-specific signature, however, is advantageous - as it offers discrete identification of active infection, and discrimination from exposure. It also offers a universal strategy that can be applied to human and animal hosts of infection - allowing for One Health Biosurveillance. Achieving this, however, requires the development of a) tailored strategies for the measurement of biochemically disparate pathogen signatures in clinical samples and b) ultra-sensitive detection of such signatures in the host. The sensor team at Los Alamos National Laboratory is working on both of these aspects, and the development of One Health Diagnostic platforms, the focus of the work presented here.MethodsMany of the biomarkers secreted by bacterial pathogens and recognized by innate immune receptors elicit host cytokine responses that are amphiphilic (largely glycolipids, lipoproteins or lipoglycans). Based on such, our team has developed tailored methods – membrane insertion and lipoprotein capture for the capture and detection of these greasy and stealthy molecules in infected blood. Sensitivity and specificity, assay optimization, alinearity associated with lipidic molecules and assay parameter development for biomarkers associated with bacterial pathogens will be presented. Considerations for clinical sampling for amphiphile detection in blood, and clinical study design will be demonstrated. Our team has developed an ultra-sensitive biosensor for detection of biomarkers in complex matrices based on the evanescent field properties of single mode planar optical waveguides. Detection of amphiphilic biomarkers in clinical samples, using the waveguide-based biosensor and tailored methods for the detection of such molecules has allowed for the diagnosis of infection in both human and animals hosts. Herein, we present two examples of the same; 1) diagnosis of tuberculosis in humans, cattle and badgers using pathogen-based diagnostic strategies; and 2) detection of Gram-negative Lipopolysacharides in beef and in patients with Salmonella-induced sepsis.ResultsWe have developed tailored ultra-sensitive waveguide-biosensor assays for the detection of Lipoarabinomannan (and other biomarkers) from Mycobacteria and demonstrated feasibility in blinded clinical studies in humans and cattle, demonstrating one -health compatibility.We have also demonstrated detection of lipopolysacharides from eight different serotypes of Shiga-toxin carrying E. coli in beef, and Salmonella Typhimurium in pediatric patients using the same approach.ConclusionsWe have demonstrated clinical feasibility of a One Health Strategy for point-of-care diagnostics of bacterial infections in blood for tuberculosis and Gram-negative pathogens in clinical samples. The results will be demonstrated with several discussion points on the consideration of unconventional biochemistry of pathogens for diagnostics, factors influencing point-of-care deployment and integration of diagnostic platforms for biosurveillance. One Health Considerations and challenges therein will also merit discussion.ReferencesSakamuri, R; et al. Accurate Tracking of Bovine Tuberculosis Biomarkers in Infected Cattle using a Novel Biomarker Capture Strategy, Analytical Sciences, 33(4): 457-460, 2017.Noormohammed A et al. Detection of Salmonella LPS in Patient blood by Lipoprotein Capture. Proc. SPIE 10072, Optical Diagnostics and Sensing XVII: Toward Point-of-Care Diagnostics, 100720A , 2017. doi:10.1117/12.2253506Stromberg L et al. Membrane Insertion for the Detection of Lipopolysaccharides: Exploring the Dynamics of Amphiphile-in-Lipid Assays, PloS One, April 2016.Sakamuri RM et al. Association of lipoarabinomannan with high density lipoprotein in blood: implications for diagnostics.Tuberculosis (Edinb). 2013 May;93(3):301-7. doi: 10.1016/j.tube.2013.02.015. Epub 2013 Mar 16Mukundan H et al. Understanding the interaction of Lipoarabinomannan with membrane mimetic architectures. Tuberculosis, 92(1) 32-47, 2012.Mukundan H et al., Waveguide-based Sensors for Pathogen Detection, Invited Review, Sensors, 9(7), 5783-5809.

Mukundan, Harshini↗

Improved semi-conductor laser device, operating, at room temperature, with an array of three lasers in the spatially coherent, free running mode

The peak pulse power was increased by operating an array of three homostructure Ga As lasers in the laser device. A spatial filter in the laser device selects the spatially coherent, free running, mode. The optical peak power is 5 watts, which is three times the peak power of a single laser in the array. The far-field distribution of the three laser array is a single Gaussian beam of spatial coherence without sidelobes or grating lobes. The length of the optical pulses of spatial coherence was increased to 200 ns by improved heat transfer from the p-n junctions of the lasers to the metal housing of the pulse transformer, and by doubling the core area and increasing the turns of the primary windings of the pulse transformer. The mechanical stability of the laser device was improved and the transition from mechanical alignment to electro-mechanical alignment control, was facilitated.

Rutz, E. M.↗

Test evaluation of the Sperry laser gyro model ASLG 15

Various parameters were evaluated such as bias, scale factor, scale factor sensitivity to supply voltage and external temperature, and turn-on trends. Photographs and descriptions of test equipment are given, and test procedures are outlined. A systems description (electronic equipment, block diagrams), performance characteristics, and equipment specifications of the laser gyro model are given. Also considered are the laser beam optics (laser mode locking). Results are reported for the various parameters examined, and recommendations given.

Source record↗

The LASL program in nuclear pumped liquid lasers

The development of nuclear-pumped, liquid-based lanthanide ion lasers is discussed. Early investigations of lanthanide ion lasers have lead to solid-state and gaseous neodymium lasers, and a demonstration of lasing in the liquid state. Solvents containing organic chelating agents have been employed in liquid Eu(+3) and Tb(+3) lasers to extend fluorescence lifetimes, however aprotic solvents have been found to enable the development of large-scale liquid lasers. The advantages to be gained from high-power nuclear-pumped lasers based on lanthanide solutions include the high density of fissile materials possible, and a nuclear pumping cell which can operate in either a nuclear or optical pumping mode is being fabricated at the Los Alamos Scientific Laboratory to investigate the nuclear pumping of liquid lanthanide ion lasers. Areas that need exploration before specific laser design features can be considered include energy channeling within the liquid upon excitation, radiation damage due to solvent dissociation, and reactor technology for the development of a self-critical liquid reactor.

Mansfield, C. R.↗

Crossover Concept for Optical Printed Circuits

It is possible to reduce crosstalk between optical signals in intersecting optical conductors by taking two steps: Minimize amount of light diffracted into wrong conductor by selecting optimum conductor width, and place light traps in each conductor. How well techniques work depends in part on quality of optical conductors (partically surface smoothness) and on how closely optical-signal mode of propagation approaches ideal. Nature of signals also important: With digital signals, less crosstalk attenuation required than for analog signals.

Jamieson, R. S.↗

Polarization-stabilized 1.15- and 3.39-micron He-Ne lasers

Two methods for polarization stabilization of an internal-mirror 3.39-micron He-Ne laser are reported. The first relies on a concurrently lasing 1.15-micron transition by fixing the relative amplitude of two orthogonally polarized longitudinal modes that are split by a Rochon prism and detected with separate Si photodiodes. In the second method, two spatially separated orthogonally polarized adjacent 3.39-micron modes are optically balanced, differentially chopped, and recombined on a single InSb photodiode for phase-sensitive detection. The dual-wavelength scheme has been tested by beating against a methane-stabilized 3.39-micron He-Ne laser, which yields maximum excursions of less than 0.5 MHz over several hours and comparable reproducibility. The polarization-stabilized He-Ne laser has been used as a reference for a tunable color-center laser molecular-beam optothermal spectrometer and provides a precision of better than 2 MHz.

Junttila, M.-L.↗

A CCD offset guider for the KAO

We describe a focal plane guider for the Kuiper Airborne Observatory which consists of a CCD camera interfaced to an AMIGA personal computer. The camera is made by Photometrics Ltd. and utilizes a Thomson 576 x 384 pixel CCD chip operated in Frame Transfer mode. Custom optics produce a scale of 2.4 arc-sec/pixel, yielding an approx. 12 ft. diameter field of view. Chopped images of stars with HST Guide Star Catalog magnitudes fainter than 14 have been used for guiding at readout rates greater than or equal to 0.5 Hz. The software includes automatic map generation, subframing and zooming, and correction for field rotation when two stars are in the field of view.

Colgan, Sean W. J.↗

Raman Spectroscopy as a Method for Mineral Identification on Lunar Robotic Exploration Missions

The sharp, nonoverlapping Raman bands for plagioclase, pyroxene, and olivine would be advantageous for on-surface, active mineralogical analysis of lunar materials. A robust, light-weight, low-power, rover-based Raman spectrometer with a laser exciting source, entirely transmission-mode holographic optics, and a charge-coupled device (CCD) detector could fit within a less than 20 cm cube. A sensor head on the end of an optical fiber bundle that carried the laser beam and returned the scattered radiation could be placed against surfaces at any desired angle by a deployment mechanism; otherwise, the instrument would need no moving parts. A modem micro-Raman spectrometer with its beam broadened (to expand the spot to 50-micrometer diameter) and set for low resolution (7/cm in the 100-1400/cm region relative to 514.5-nm excitation), was used to simulate the spectra anticipated from a rover instrument. We present spectra for lunar mineral grains, less than 1 mm soil fines, breccia fragments, and glasses. From frequencies of olivine peaks, we derived sufficiently precise forsterite contents to correlate the analyzed grains to known rock types and we obtained appropriate forsterite contents from weak signals above background in soil fines and breccias. Peak positions of pyroxenes were sufficiently well determined to distinguish among orthorhombic, monoclinic, and triclinic (pyroxenoid) structures; additional information can be obtained from pyroxene spectra, but requires further laboratory calibration. Plagioclase provided sharp peaks in soil fines and most breccias even when the glass content was high.

Wang, Alian↗