Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Electrochemical etching of cylindrical nanoprobes using a vibrating electrolyte

An electrochemical etching process using a vibrating electrolyte of potassium hydroxide to prepare tungsten cylindrical nanotips is developed. The vibrating electrolyte eases the effects of a diffusion layer and extends the etching area, which aid in the production of cylindrical nanotips. Larger amplitudes and a vibration frequency of 35 Hz are recommended for producing cylindrical nanotips. Nanotips with a tip radius of approximately 43 nm and a conical angle of arctan 0.0216 are obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Electrochemical cell for in operando X-ray diffraction measurements on a conventional X-ray diffractometer

Electrochemical in operando X-ray diffraction (XRD) is a powerful method to analyze structural changes of energy storage materials while inserting/de-inserting charge carriers, such as Li- or Na-ions, into/from a host structure. The design of an XRD in operando cell is presented, which enables the use of thin (6 μm) aluminum foil as X-ray window as a non-toxic alternative to conventional beryllium windows. Owing to the reduced thickness, diffraction patterns and their changes during cycling can be observed with excellent quality, which was demonstrated for two cathode materials for sodium-ion batteries in a half-cell set-up, P2-Na{sub 0.7}MnO{sub 2} and Na{sub 2.55}V{sub 6}O{sub 16} ⋅ 0.6H{sub 2}O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Design and development of wireless controlled aerosol sampling network for large scale aerosol dispersion experiments

Wireless based custom built aerosol sampling network is designed, developed, and implemented for environmental aerosol sampling. These aerosol sampling systems are used in field measurement campaign, in which sodium aerosol dispersion experiments have been conducted as a part of environmental impact studies related to sodium cooled fast reactor. The sampling network contains 40 aerosol sampling units and each contains custom built sampling head and the wireless control networking designed with Programmable System on Chip (PSoC™) and Xbee Pro RF modules. The base station control is designed using graphical programming language LabView. The sampling network is programmed to operate in a preset time and the running status of the samplers in the network is visualized from the base station. The system is developed in such a way that it can be used for any other environment sampling system deployed in wide area and uneven terrain where manual operation is difficult due to the requirement of simultaneous operation and status logging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Upgrade of electron cyclotron emission imaging system and preliminary results on HL-2A tokamak

The electron cyclotron emission imaging system on the HL-2A tokamak has been upgraded to 24 (poloidally) × 16 (radially) channels based on the previous 24 × 8 array. The measurement region can be flexibly shifted due to the independence of the two local oscillator sources, and the field of view can be adjusted easily by changing the position of the zoom lenses. The temporal resolution is about 2.5 μs and the achievable spatial resolution is 1 cm. After laboratory calibration, it was installed on HL-2A tokamak in 2014, and the local 2D mode structures of MHD activities were obtained for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Compact and light displacement sensor for a precision measurement system in large motion

We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, a simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Coherent resonances observed in the dissociative electron attachment to carbon monoxide

Succeeding our previous finding about coherent interference of the resonant states of CO{sup −} formed by the low-energy electron attachment [Tian et al. Phys. Rev. A 88, 012708 (2013)], here we provide further evidence of the coherent interference. The completely backward distributions of the O{sup −} fragment of the temporary CO{sup −} are observed with anion velocity map imaging technique in an electron energy range of 11.3–12.6 eV and explained as the results of the coherent interferences of three resonant states. Furthermore, the state configuration of the interference is changed with the increase of electron attachment energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Improving long-term stability of hot-wire anemometer sensors by means of annealing

Annealing procedures for hot-wire sensors of platinum and platinum-plated tungsten have been investigated experimentally. It was discovered that the two investigated sensor metals behave quite differently during the annealing process, but for both types annealing may improve long-term stability considerably. Measured drift of sensors both without and with prior annealing is presented. Suggestions for suitable annealing temperatures and times are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A disposable x-ray camera based on mass produced complementary metal-oxide-semiconductor sensors and single-board computers

We have integrated mass-produced commercial complementary metal-oxide-semiconductor (CMOS) image sensors and off-the-shelf single-board computers into an x-ray camera platform optimized for acquisition of x-ray spectra and radiographs at energies of 2–6 keV. The CMOS sensor and single-board computer are complemented by custom mounting and interface hardware that can be easily acquired from rapid prototyping services. For single-pixel detection events, i.e., events where the deposited energy from one photon is substantially localized in a single pixel, we establish ∼20% quantum efficiency at 2.6 keV with ∼190 eV resolution and a 100 kHz maximum detection rate. The detector platform’s useful intrinsic energy resolution, 5-μm pixel size, ease of use, and obvious potential for parallelization make it a promising candidate for many applications at synchrotron facilities, in laser-heating plasma physics studies, and in laboratory-based x-ray spectrometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: An improved calibration system with phase correction for electronic transformers with digital output

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A note on the cylindrical solitary waves in an electron-acoustic plasma with vortex electron distribution

In the present work, we consider the propagation of nonlinear electron-acoustic non-planar waves in a plasma composed of a cold electron fluid, hot electrons obeying a trapped/vortex-like distribution, and stationary ions. The basic nonlinear equations of the above described plasma are re-examined in the cylindrical coordinates through the use reductive perturbation method in the long-wave approximation. The modified cylindrical Korteweg-de Vries equation with fractional power nonlinearity is obtained as the evolution equation. Due to the nature of nonlinearity, which is fractional, this evolution equation cannot be reduced to the conventional Korteweg–de Vries equation. An analytical solution to the evolution equation, by use of the method developed by Demiray [Appl. Math. Comput. 132, 643 (2002); Comput. Math. Appl. 60, 1747 (2010)] and a numerical solution by employing a spectral scheme are presented and the results are depicted in a figure. The numerical results reveal that both solutions are in good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Derivation of two-photon circular dichroism—Addendum to “Two-photon circular dichroism” [J. Chem. Phys. 62, 1006 (1975)]

This addendum shows the detailed derivation of the fundamental equations for two-photon circular dichroism which are given in a very condensed form in the original publication [I. Tinoco, J. Chem. Phys. 62, 1006 (1975)]. In addition, some minor errors are corrected and some of the derivations in the original publication are commented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Utilization of polymer gel as a bolus compensator and a dosimeter in the near-surface buildup region for breast-conserving therapy

Tangential beam radiotherapy is routinely used for radiation therapy after breast conserving surgery. A tissue-equivalent bolus placed on the irradiated area shifts the depth of the dose distribution; this bolus provides uniform dose distribution to the breast. The gel bolus made by the BANG-Pro{sup ®} polymer gel and in an oxygen non-transmission pack was applicable as a dosimeter to measure dose distribution in near-surface buildup region. We validated the use of the gel bolus to improve in the whole-breast/chest wall, including the near-surface buildup region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Directly measuring the direct digital synthesizer frequency chirp-rate for an atom interferometer

During gravity measurements with Raman type atom interferometry, the frequency of the laser used to drive Raman transition is scanned by chirping the frequency of a direct digital synthesizer (DDS), and the local gravity is determined by precisely measuring the chip rate α of DDS. We present an effective method that can directly evaluate the frequency chirp rate stability of our DDS. By mixing a pair of synchronous linear sweeping signals, the chirp rate fluctuation is precisely measured with a frequency counter. The measurement result shows that the relative α instability can reach 5.7 × 10{sup −11} in 1 s, which is neglectable in a 10{sup −9} g level atom interferometry gravimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗