Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Thermoelectric Generator Powered Wireless Sensor Node Prototype for Nuclear Applications

This report presents the development a TEG-powered WSN prototype that could be used in nuclear applications. Different design considerations that are important in assembling different components of a WSN were carefully taken into consideration. In designed WSN is compatible to operate with low-power generating TEG and high-power generating TEG based on application requirements. Also, to maintain appropriate power level across different sensor node components, direct current-to-direct current converter with maximum peak power tracking algorithm is implemented. Storage device with real-time clock is embedded to enable local data storage and real-time time stamping. The wireless communication module selected and implemented is Zig Bee protocol. To accommodate different operating conditions and any loss of power from TEG due to unforeseen reasons, backup battery system is also implemented. Entire assembly is performed on a 2-layer printed circuit board and tested for operation. The outcome was successful and it also provided data to validate the mathematical model developed to estimate average power consumption of a WSN under different operating conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Permutation Engine Switching Node

We describe an asynchronous, strictly non-blocking crossbar node topology and distributed routing algorithm that is particularly suited to optoelectronic implementation.

Permutation engine permutation node topology routi↗

Smart Data Node in the Sky (SDNITS): communications system

In this paper we will discuss: the steps for adequately designing such a complex telecommunications system 'Smart Data Node In The Sky (SDNITS)'; algorithm development for this process; specifications to be levied on the interfacing subsystems; type of the system e.g., the usual Radio Frequency system or a laser communications system.

communication smart node technology system archite↗

Arbitrary-level hanging nodes for adaptive hphp-FEM approximations in 3D

In this paper we discuss constrained approximation with arbitrary-level hanging nodes in adaptive higher-order finite element methods (hphp-FEM) for three-dimensional problems. This technique enables using highly irregular meshes, and it greatly simplifies the design of adaptive algorithms as it prevents refinements from propagating recursively through the finite element mesh. The technique makes it possible to design efficient adaptive algorithms for purely hexahedral meshes. We present a detailed mathematical description of the method and illustrate it with numerical examples.

99 GENERAL AND MISCELLANEOUS↗

Consideration of the Role of Radiotherapy for Abdominal Lymph Node Metastases in Patients With Recurrent Gastric Cancer

Purpose: To evaluate the outcome of external beam radiotherapy for abdominal lymph node (LN) metastases in patients with recurrent gastric cancer. Methods and Materials: The clinical data of 79 patients with abdominal LN metastases developing after curative resection of gastric tumor were retrospectively analyzed. Of the 79 patients, 37 received radiation (40-60 Gy in fractions of 2.0 Gy daily, five times weekly; termed the radiation group), and 42 received chemotherapy or supportive care (the nonradiation group). The Kaplan-Meier method was used to evaluate survival, and a Cox regression model was used to identify predictors of prognosis. Results: After radiation, complete response and partial response were observed in 29.7% and 54.1% of patients, respectively. Clinical symptoms were relieved in 19 of 21 patients (90.5%) after completing radiation. Median survival time was 11.4 months in the radiation group and 4.8 months in the nonradiation group. Overall survival for patients with and without radiation was 43.2% and 19.0% at 1 year and 27.6% and 4.1% at 2 years, respectively (p = 0.002). Multivariate analysis showed that the relative risk of death in the radiation group from the time of diagnosis of LN metastases was 0.253 (p < 0.001). The most common adverse effect of radiation was gastrointestinal toxicity, but it was mild in most patients. Conclusions: Abdominal LN metastases from gastric cancer are sensitive to radiation. Delivery of 50 Gy is effective as palliative treatment and may prolong overall survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence of a Uranium‐Paddlewheel Node in a Catecholate‐Based Metal–Organic Framework

Abstract The interactions between uranium and non‐innocent organic species are an essential component of fundamental uranium redox chemistry. However, they have seldom been explored in the context of multidimensional, porous materials. Uranium‐based metal–organic frameworks (MOFs) offer a new angle to study these interactions, as these self‐assembled species stabilize uranium species through immobilization by organic linkers within a crystalline framework, while potentially providing a method for adjusting metal oxidation state through coordination of non‐innocent linkers. We report the synthesis of the MOF NU‐1700 , assembled from U 4+ ‐paddlewheel nodes and catecholate‐based linkers. We propose this highly unusual structure, which contains two U 4+ ions in a paddlewheel built from four linkers—a first among uranium materials—as a result of extensive characterization via powder X‐ray diffraction (PXRD), sorption, transmission electron microscopy (TEM), and thermogravimetric analysis (TGA), in addition to density functional theory (DFT) calculations.

Knapp, Julia G.↗

Evidence of a Uranium‐Paddlewheel Node in a Catecholate‐Based Metal–Organic Framework

Abstract The interactions between uranium and non‐innocent organic species are an essential component of fundamental uranium redox chemistry. However, they have seldom been explored in the context of multidimensional, porous materials. Uranium‐based metal–organic frameworks (MOFs) offer a new angle to study these interactions, as these self‐assembled species stabilize uranium species through immobilization by organic linkers within a crystalline framework, while potentially providing a method for adjusting metal oxidation state through coordination of non‐innocent linkers. We report the synthesis of the MOF NU‐1700 , assembled from U 4+ ‐paddlewheel nodes and catecholate‐based linkers. We propose this highly unusual structure, which contains two U 4+ ions in a paddlewheel built from four linkers—a first among uranium materials—as a result of extensive characterization via powder X‐ray diffraction (PXRD), sorption, transmission electron microscopy (TEM), and thermogravimetric analysis (TGA), in addition to density functional theory (DFT) calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Node failure resiliency for Uintah without checkpointing

The frequency of failures in upcoming exascale supercomputers may well be greater than at present due to many-core architectures if component failure rates remain unchanged. This potential increase in failure frequency coupled with I/O challenges at exascale may prove problematic for current resiliency approaches such as checkpoint restarting, although the use of fast intermediate memory may help. Algorithm-Based Fault Tolerance (ABFT) using Adaptive Mesh Refinement (AMR) is one resiliency approach used to address these challenges. For adaptive mesh codes, a coarse mesh version of the solu- tion may be used to restore the fine mesh solution. This paper addresses the implementation of the ABFT approach within the Uintah software framework: both at a software level within Uintah and in the data reconstruction method used for the recovery of lost data. This method has two problems: inaccuracies introduced during the reconstruction propagate forward in time, and the physical consistency of variables such as positivity or boundedness may be violated during interpolation. These challenges can be addressed by the combination of two techniques: 1. a fault-tolerant MPI implementation to recover from runtime node failures, and 2. high-order interpolation schemes to preserve the physical solution and reconstruct lost data. Here, the approach considered here uses a "Limited Essentially Non-Oscillatory" (LENO) scheme along with AMR to rebuild the lost data without checkpointing using Uintah. Experiments were carried out using a fault-tolerant MPI - ULFM to recover from runtime failure, and LENO to recover data on patches belonging to failed ranks, while the simulation was continued to the end. Results show that this ABFT approach is up to 10x faster than the traditional checkpointing method. The new interpolation approach is more accurate than linear interpolation and not subject to the overshoots found in other interpolation methods.

97 MATHEMATICS AND COMPUTING↗

Dirac Nodes and Magnetic Order in M 2 X 2 Transition‐Metal Chalcogenides

In this study, we perform a computational analysis of the M 2 X 2 transition‐metal chalcogenides (TMCs). Using density functional theory with a spin‐polarized generalized gradient approximation, we examine the magnetic and electronic properties for the antiferromagnetic and ferromagnetic states with M = Cr, Mn, and Fe and X = S and Se. After optimizing the geometric structure for stability, we examine the spin‐polarized electronic structure, density of states, and Mulliken population. It is discovered that these materials are quasi‐two‐dimensional honeycomb lattices with metallic antiferromagnetic ground states. The structures consist of a distorted tetrahedral crystal‐field symmetry that has a distinct magnetic moment. An analysis of the electronic structure shows the presence of nodal points that resemble Dirac nodes for all cases, which leads to the possibility of the realization of magnetic Dirac materials.

La Martina, Thomas↗

Pairing high-frequency data with a link-node model to manage dissolved oxygen impairment in a dredged estuary

High-frequency data and a link-node model were used to investigate the relative importance of mass loads of oxygen-demanding substances and channel geometry on recurrent low dissolved oxygen (DO) in the San Joaquin River Estuary in California. The model was calibrated using 6 years of data. The calibrated model was then used to determine the significance of the following factors on low DO: excavation of the river to allow navigation of large vessels, non-point source pollution from the agricultural watershed, effluent from a wastewater treatment plant, and non-point source pollution from an urban area. An alternative metric for low DO, excess net oxygen demand (ENOD), was applied to better characterize DO impairment. Model results indicate that the dredged ship channel had the most significant effect on DO (62 % fewer predicted hourly DO violations), followed by mass load inputs from the watershed (52 % fewer predicted hourly DO violations). Model results suggest that elimination of any one factor will not completely resolve DO impairment and that continued use of supplemental aeration is warranted. Calculation of ENOD proved more informative than the sole use of DO. Application of the simple model allowed for interpretation of the extensive data collected. The current monitoring program could be enhanced by additional monitoring stations that would provide better volumetric estimates of low DO.

54 ENVIRONMENTAL SCIENCES↗

Prevention of Overcurrent and Admissible Voltage Limit Violation in Electrical Network Nodes

In a centralized emergency control system (CECS) with a third-generation algorithm, emergency control actions (CA) are selected under conditions of preventing disruption of dynamic stability, providing the required margin of stability in post-emergency condition, as well as preventing overcurrent and restricting voltage in network nodes to admissible limits. A methodology for selecting CAs for these last two conditions is described.

42 ENGINEERING↗

Stress-hybrid virtual element method on six-noded triangular meshes for compressible and nearly-incompressible linear elasticity

In this paper, we present a first-order Stress-Hybrid Virtual Element Method (SH-VEM) on six-noded triangular meshes for linear plane elasticity. Here, we adopt the Hellinger–Reissner variational principle to construct a weak equilibrium condition and a stress based projection operator. In each element, the stress projection operator is expressed in terms of the nodal displacements, which leads to a displacement based formulation. This stress-hybrid approach assumes a globally continuous displacement field while the stress field is discontinuous across each element. The stress field is initially represented by divergence-free tensor polynomials based on Airy stress functions, but we also present a formulation that uses a penalty term to enforce the element equilibrium conditions, referred to as the Penalty Stress-Hybrid Virtual Element Method (PSH-VEM). Numerical results are presented for PSH-VEM and SH-VEM, and we compare their convergence to the composite triangle FEM and B-bar VEM on benchmark problems in linear elasticity. The SH-VEM converges optimally in the L 2 norm of the displacement, energy seminorm, and the L 2 norm of hydrostatic stress. Furthermore, the results reveal that PSH-VEM converges in most cases at a faster rate than the expected optimal rate, but it requires the selection of a suitably chosen penalty parameter.

42 ENGINEERING↗

Defining the Risk of Involvement for Each Neck Nodal Level in Patients With Early T-Stage Node-Positive Oropharyngeal Carcinoma

Purpose: To assess the risk of ipsilateral subclinical neck nodal involvement for early T-stage/node-positive oropharyngeal squamous cell carcinoma. Methods and Materials: Patients undergoing multilevel upfront neck dissection (ND) at Johns Hopkins Hospital within the last 10 years for early clinical T-stage (cT1-2) node-positive (cN+) oropharyngeal squamous cell carcinoma were identified. Pathologic involvement of Levels IB-V was determined. For each nodal level, the negative predictive value of imaging results was computed by using sensitivity/specificity data for computed tomography (CT). This was used to calculate 1 - negative predictive value, or the risk that a negative level on CT harbors subclinical disease. Results: One hundred three patients met the criteria. Radical ND was performed in 14.6%; modified radical ND, in 70.9%; and selective ND, in 14.6%. Pathologic positivity rates were 9.5%, 91.3%, 40.8%, 18.0%, and 3.3% for Levels IB-V, respectively. Risks of subclinical disease despite negative CT imaging results were calculated as 3.1%, 76.3%, 17.5%, 6.3%, and 1.0% for Levels IB-V, respectively. Conclusions: Levels IB and V are at very low (<5%) risk of involvement, even with ipsilateral to pathologically proven neck disease; this can guide radiation planning. Levels II and III should be included in high-risk volumes regardless of imaging results, and Level IV should be included within the lowest risk volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Need for High Radiation Dose (>=70 Gy) in Early Postoperative Irradiation After Radical Prostatectomy: A Single-Institution Analysis of 334 High-Risk, Node-Negative Patients

Purpose: To determine the clinical benefit of high-dose early adjuvant radiotherapy (EART) in high-risk prostate cancer (hrCaP) patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy. Patients and Methods: The clinical outcome of 334 hrCaP (pT3-4 and/or positive resection margins) node-negative patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy before 2004 was analyzed according to the EART dose delivered to the prostatic bed, <70.2 Gy (lower dose, median 66.6 Gy, n = 153) or >=70.2 Gy (median 70.2 Gy, n = 181). Results: The two groups were comparable except for a significant difference in terms of median follow-up (10 vs. 7 years, respectively) owing to the gradual increase of EART doses over time. Nevertheless, median time to prostate-specific antigen (PSA) failure was almost identical, 38 and 36 months, respectively. At univariate analysis, both 5-year biochemical relapse-free survival (bRFS) and disease-free survival (DFS) were significantly higher (83% vs. 71% [p = 0.001] and 94% vs. 88% [p = 0.005], respectively) in the HD group. Multivariate analysis confirmed EART dose >=70 Gy to be independently related to both bRFS (hazard ratio 2.5, p = 0.04) and DFS (hazard ratio 3.6, p = 0.004). Similar results were obtained after the exclusion of patients receiving any androgen deprivation. After grouping the hormone-naive patients by postoperative PSA level the statistically significant impact of high-dose EART on both 5-year bRFS and DFS was maintained only for those with undetectable values, possibly owing to micrometastatic disease outside the irradiated area in case of detectable postoperative PSA values. Conclusion: This series provides strong support for the use of EART doses >=70 Gy after radical retropubic prostatectomy in hrCaP patients with undetectable postoperative PSA levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involved-Node and Involved-Field Volumetric Modulated Arc vs. Fixed Beam Intensity-Modulated Radiotherapy for Female Patients With Early-Stage Supra-Diaphragmatic Hodgkin Lymphoma: A Comparative Planning Study

Purpose: A comparative treatment planning study was performed to compare volumetric-modulated arc (RA) to conventional intensity modulated (IMRT) for involved-field (IFRT) and involved-node (INRT) radiotherapy for Hodgkin lymphoma (HL). Methods and Materials: Plans for 10 early-stage HL female patients were computed for RA and IMRT. First, the planning target volume (PTV) coverage and organs at risk (OAR) dose deposition was assessed between the two modalities. Second, the OAR (lung, breast, heart, thyroid, and submandibular gland) dose-volume histograms were computed and compared for IFRT and INRT, respectively. Results: For IFRT and INRT, PTV coverage was equally homogeneous with both RA and IMRT. By and large, the OAR irradiation with IFRT planning was not significantly different between RA and IMRT. For INRT, doses computed for RA were, however, usually lower than those with IMRT, particularly so for the lung, breast, and thyroid. Regardless of RA and IMRT modalities, a significant 20-50% decrease of the OAR computed mean doses was observed with INRT when compared with IFRT (Breast D{sub Mean} 1.5 +- 1.1 vs. 2.6 +- 1.7 Gy, p < 0.01 and 1.6 +- 1.1 vs. 2.9 +- 1.9 Gy, p < 0.01 for RA and IMRT, respectively). Conclusions: RA and IMRT results in similar level of dose homogeneity. With INRT but not IFRT planning, the computed doses to the PTV and OAR were usually higher and lower with RA when compared to IMRT. Regardless of the treatment modality, INRT when compared with IFRT planning led to a significant decrease in OAR doses, particularly so for the breast and heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy Improves Dosimetry and Reduces Treatment Time Compared to Conventional Intensity-Modulated Radiotherapy for Locoregional Radiotherapy of Left-Sided Breast Cancer and Internal Mammary Nodes

Purpose: Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (cIMRT), in which an optimized three-dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to RapidArc (Varian Medical System). This study compared VMAT with cIMRT and with conventional modified wide-tangent (MWT) techniques for locoregional radiotherapy for left-sided breast cancer, including internal mammary nodes. Methods and Materials: Therapy for 5 patients previously treated with 50 Gy/25 fractions using nine-field cIMRT was replanned with VMAT and MWT. Comparative endpoints were planning target volume (PTV) dose homogeneity, doses to surrounding structures, number of monitor units, and treatment delivery time. Results: For VMAT, two 190 deg. arcs with 2-cm overlapping jaws were required to optimize over the large treatment volumes. Treatment plans generated using VMAT optimization resulted in PTV homogeneity similar to that of cIMRT and MWT. The average heart volumes receiving >30 Gy for VMAT, cIMRT, and MWT were 2.6% +- 0.7%, 3.5% +- 0.8%, and 16.4% +- 4.3%, respectively, and the average ipsilateral lung volumes receiving >20 Gy were 16.9% +- 1.1%, 17.3% +- 0.9%, and 37.3% +- 7.2%, respectively. The average mean dose to the contralateral medial breast was 3.2 +- 0.6 Gy for VMAT, 4.3 +- 0.4 Gy for cIMRT, and 4.4 +- 4.7 Gy for MWT. The healthy tissue volume percentages receiving 5 Gy were significantly larger with VMAT (33.1% +- 2.1%) and IMRT (45.3% +- 3.1%) than with MWT (19.4% +- 3.7%). VMAT reduced the number of monitor units by 30% and the treatment time by 55% compared with cIMRT. Conclusions: VMAT achieved similar PTV coverage and sparing of organs at risk, with fewer monitor units and shorter delivery time than cIMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involved-Node Radiotherapy and Modern Radiation Treatment Techniques in Patients With Hodgkin Lymphoma

Purpose: To assess the clinical outcome of the involved-node radiotherapy (INRT) concept using modern radiation treatments (intensity-modulated radiotherapy [IMRT]or deep-inspiration breath-hold radiotherapy [DIBH) in patients with localized supradiaphragmatic Hodgkin lymphoma. Methods and Materials: All but 2 patients had early-stage Hodgkin lymphoma, and they were treated with chemotherapy prior to irradiation. Radiation treatments were delivered using the INRT concept according to European Organization for Research and Treatment of Cancer guidelines. IMRT was performed with the patient free-breathing. For the adapted breath-hold technique, a spirometer dedicated to DIBH radiotherapy was used. Three-dimensional conformal radiotherapy was performed with those patients. Results: Fifty patients with Hodgkin lymphoma (48 patients with primary Hodgkin lymphoma, 1 patient with recurrent disease, and 1 patient with refractory disease) entered the study from January 2003 to August 2008. Thirty-two patients were treated with IMRT, and 18 patients were treated with the DIBH technique. The median age was 28 years (range, 17-62 years). Thirty-four (68%) patients had stage I - (I-IIA) IIA disease, and 16 (32%) patients had stage I - (I-IIB) IIB disease. All but 3 patients received three to six cycles of adriamycin, bleomycin, vinblastine, and dacarbazine (ABVD). The median radiation doses to patients treated with IMRT and DIBH were, respectively, 40 Gy (range, 21.6-40 Gy) and 30.6 Gy (range, 19.8-40 Gy). Protection of various organs at risk was satisfactory. Median follow-up was 53.4 months (range, 19.1-93 months). The 5-year progression-free and overall survival rates for the whole population were 92% (95% confidence interval [CI], 80%-97%) and 94% (95% CI, 75%-98%), respectively. Recurrences occurred in 4 patients: 2 patients had in-field relapses, and 2 patients had visceral recurrences. Grade 3 acute lung toxicity (transient pneumonitis) occurred in 1 case. Conclusions: Our results suggest that patients with localized Hodgkin lymphoma can be safely and efficiently treated using the INRT concept and modern radiation treatment techniques such as IMRT and DIBH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consolidative Involved-Node Proton Therapy for Stage IA-IIIB Mediastinal Hodgkin Lymphoma: Preliminary Dosimetric Outcomes From a Phase II Study

Purpose: To compare the dose reduction to organs at risk (OARs) with proton therapy (PT) versus three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in patients with mediastinal Hodgkin lymphoma (HL) enrolled on a Phase II study of involved-node radiotherapy (INRT). Methods and Materials: Between June 2009 and October 2010, 10 patients were enrolled on a University of Florida institutional review board-approved protocol for de novo 'classical' Stage IA-IIIB HL with mediastinal (bulky or nonbulky) involvement after chemotherapy. INRT was planned per European Organization for Research and Treatment of Cancer guidelines. Three separate optimized plans were developed for each patient: 3D-CRT, IMRT, and PT. The primary end point was a 50% reduction in the body V4 with PT compared with 3D-CRT or IMRT. Results: The median relative reduction with PT in the primary end point, body V4, was 51% compared with 3D-CRT (p = 0.0098) and 59% compared with IMRT (p = 0.0020), thus all patients were offered treatment with PT. PT provided the lowest mean dose to the heart, lungs, and breasts for all 10 patients compared with either 3D-CRT or IMRT. The median difference in the OAR mean dose reduction with PT compared with 3D-CRT were 10.4 Gy/CGE for heart; 5.5 Gy/CGE for lung; 0.9 Gy/CGE for breast; 8.3 Gy/CGE for esophagus; and 4.1 Gy/CGE for thyroid. The median differences for mean OAR dose reduction for PT compared with IMRT were 4.3 Gy/CGE for heart, 3.1 Gy/CGE for lung, 1.4 Gy/CGE for breast, 2.8 Gy/CGE for esophagus, and 2.7 Gy/CGE for thyroid. Conclusions: All 10 patients benefitted from dose reductions to OARs with PT compared with either 3D-CRT or IMRT. It is anticipated that these reductions in dose to OAR will translate into lower rates of late complications, but long-term follow-up on this Phase II INRT study is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗