Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Gravitational-Wave Physics and Astronomy in the 2020s and 2030s

The 100 years since the publication of Albert Einstein’s theory of General Relativity saw significant development of the understanding of the theory, the identification of potential astrophysical sources of sufficiently strong gravitational waves, and development of key technologies for gravitational-wave detectors. In 2015, the first gravitational wave signals were detected by the two US Advanced LIGO instruments. In 2017, Advanced LIGO and the European Advanced Virgo detectors pinpointed a binary neutron star coalescence that was also seen across the electromagnetic spectrum. The field of gravitational wave astronomy is just starting, and this Roadmap of future developments surveys the potential for growth in bandwidth and sensitivity of future gravitational-wave detectors and discusses the science results anticipated to come from upcoming instruments.

Compact astrophysical objects↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Detector needs for STS instruments

This white paper contains an analysis of the requirements for the detectors for the initial suite of neutron scattering instruments at the Second Target Station, STS. The detector technologies proposed are compared with the instrument requirements, in-house proficiencies and strengths, and where appropriate, expertise at other facilities. Where relevant, alternative detector options are proposed. The performance gaps between the current state-of-the-art and the required characteristics are identified and projects within the R&D program are proposed in order to close these gaps. Further, neutron beam monitor needs are considered in a similar light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of limited coverage effects on areal density measurements in inertial confinement fusion implosions

Accurate diagnosis of areal density ($\textit{ρR}$) is critical for the inference of performance metrics in inertial confinement fusion implosions. One potential source of error in this diagnosis is the existence of low mode perturbations in the imploding target, which lead to asymmetries in the inference of the $\textit{ρR}$ from different lines of sight. Here, the error accrued as a result of limited coverage of the sphere due to a finite number of detectors is quantified, and the development of a forward scatter measurement from the OMEGA neutron time-of-flight detectors is motivated. In this work, a method by which the 1D-equivalent 4 π-averaged $\langleρR\rangle$ can be reconstructed, if accurate mode information can be diagnosed by other means, is validated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron-antineutron oscillation sensitivity study at DUNE

The Deep Underground Neutrino Experiment (DUNE) aims to measure neutrino oscillations as well as search for beyond the standard model physics such as baryon number violating (BNV) processes. DUNE will use a 70 kt Liquid Argon Time Projection Chamber (LArTPC) located more than 1 km underground. A promising BNV process is neutron-antineutron oscillation ($n \rightarrow \bar{n}$) which, if discovered, would offer unique insight into the baryon asymmetry of the universe. We are developing a classification algorithm that separates $n \rightarrow \bar{n}$ events from major background atmospheric neutrino interactions using DUNE far detector simulations. We will perform the classification of signals and backgrounds by analyzing key features such as the multiplicity, isotropy, and kinematics of the reconstructed events. In the future, this algorithm can be used to obtain the sensitivity of the DUNE detectors to the neutron-antineutron oscillation lifetime.

Wheeler, Justin↗

Absorbed dose and LET spectra measurements on LDEF

Total absorbed doses measured with TLD's, linear energy transfer (LET) spectra measured with plastic track detectors, and low energy neutrons measured on LDEF have been compared with model calculations. The total absorbed doses measured in TLD's were higher than predicted in the calculations of Armstrong et al. and differ from the calculations of Atwell et al. LDEF LET spectra are dependent on detector orientation, shielding and experiment location. These factors need to be taken into account when modeling the LDEF LET spectra. LET spectra measured with plastic nuclear track detectors (PNTD's) also deviate significantly from calculations especially for high LET particles (LET(sub infinity) H2O greater than 100keV/micron). Modeling efforts to date do not include the contribution of proton induced secondaries. Analysis of polycarbonate PNTD's from the West-side of LDEF has revealed a very high fluence of tracks (greater than 1 x 10(exp 7) tracks/cm(exp 2) under 2 gm/cm(exp 2) shielding). Fluence drops off rapidly as shielding depth increases. Tracks only form in the region of the detector closest to the surface, not in the bulk of the detector. To date no adequate explanation for this observation has been found. We plan to measure range distribution of very high LET (LET (sub infinity) H2O greater than 500 keV/micron) secondary particles produced in silicon wafer by high energy primary cosmic ray particles. Refinements of experimental techniques and model calculations are being carried out in order to understand existing discrepancies between experimental measurements and calculations.

Benton, E. V.↗

Signal discrimination for neutron-antineutron oscillation sensitivity study at DUNE

The Deep Underground Neutrino Experiment (DUNE) aims to measure neutrino oscillations as well as search for beyond the standard model physics such as baryon number violating (BNV) processes. DUNE will use a 70 kt Liquid Argon Time Projection Chamber (LArTPC) located more than 1 km underground. A promising BNV process is neutron-antineutron oscillation $\left(n\rightarrow\bar{n}\right)$ which, if discovered, would offer unique insight into the baryon asymmetry of the universe. We are developing a classification algorithm that separates $n\rightarrow\bar{n}$ events from major background atmospheric neutrino interactions using DUNE far detector simulations. We will perform the classification of signals and backgrounds by analyzing key features such as the multiplicity, isotropy, and kinematics of the reconstructed events. In the future, this algorithm can be used to obtain the sensitivity of the DUNE detectors to the neutron-antineutron oscillation lifetime.

Wheeler, Justin↗

Rossi-alpha Analysis of CURIE Experiment [Slides]

Critical assembly measurement and operations are crucial to the development of benchmark data. Knowledge of the prompt neutron lifetime informs on the state of the system’s neutron spectrum. Rossi-alpha analysis can give us time-dependent information on the system. Teflon was selected, via genetic algorithm, as a moderator to target the URR in uranium for CURIE. Rossi-alpha measurements of the assembly's approach to critical using He-3 detectors estimated the prompt neutron decay constant (α) at delayed critical. α values of several subcritical measurements were then used to predict the α value at delayed critical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute Neutron Rate Measurement and Non-Thermal/Thermonuclear Fusion Differentiation

The goal of fusion energy is to produce significantly more energy from fusion reactions than is input into the device. One of the products of fusion reactions is neutrons, which, due to their lack of charge, provide a unique view into the parameters of the device. Lawrence Livermore National Laboratory (LLNL) in collaboration with the University of California, Berkeley (UCB) have designed, assembled, and fielded a robust and portable neutron detection system known as PANDA (Portable and Adaptable Neutron Diagnostics for ARPA-E). This detector suite consists of three LaBr activation detectors that are calibrated to give a total neutron yield on shot, and twenty-four scintillators coupled to photo-multiplier tubes (SPMT). The SPMTs can be configured to attain spatial, temporal and/or energy information from fusion neutrons. The system was designed to be portable and is compartmentalized so that individual components can be used at different fusion facilities. During the duration of this work, part of the system was installed at the FuZE facility, a part of Zap Energy. Another component was installed that the CESZAR facility at the University of California, San Diego (UCSD) to support experiments by Magneto-Inertial Fusion Technologies, Inc. (MIFTI). The diagnostics were successful at both locations and the LLNL/UCB team supported the data analysis by creating and running analysis scripts and Monte-Carlo calculations. At Zap Energy the diagnostics demonstrated that the fusion from the FuZE device is thermonuclear in nature, a result that resulted in an invited talk at the American Physical Society Division of Plasma Physics and an invited paper. Additionally, temporal and spatial data was taken using the SPMTs to understand the duration and length of fusion production. At UCSD the neutron yield from the diagnostics was used to show improvements to fusion yields on their gas puff Z-pinch when using a gas shell surrounding the fuel. The success in this diagnostic has led to continued work at both Zap Energy and MIFTI, as well as follow on funding and interest at other fusion energy companies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A search for solar neutrons on a long duration balloon flight

The EOSCOR 3 detector, designed to measure the flux of solar neutrons, was flown on a long duration RACOON balloon flight from Australia during Jan. through Feb, 1983. The Circum-global flight lasted 22 days. No major solar activity occurred during the flight and thus only an upper limit to the solar flare neutrons flux is given. The atmospheric neutron response is compared with that obtained on earlier flights from Palestine, Texas.

Koga, R.↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Analysis of the Multisphere Neutron Spectrometer

Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the Atmospheric Ionizing Radiation (AIR) Project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (thermal to greater than 10 GeV), total neutron fluence rate, and neutron effective dose and dose equivalent rates and their dependence on altitude and geomagnetic cutoff. The measured cosmic-ray neutron spectra have almost no thermal neutrons, a large "evaporation" peak near 1 MeV and a second broad peak near 100 MeV which contributes about 69% of the neutron effective dose. At high altitude, geomagnetic latitude has very little effect on the shape of the spectrum, but it is the dominant variable affecting neutron fluence rate, which was 8 times higher at the northernmost measurement location than it was at the southernmost. The shape of the spectrum varied only slightly with altitude from 21 km down to 12 km (56 - 201 grams per square centimeter atmospheric depth), but was significantly different on the ground. In all cases, ambient dose equivalent was greater than effective dose for cosmic-ray neutrons.

Goldhagen, P.↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Neutron reconstruction via blips in liquid argon time projection chambers

Neutrons are important final-state particles in neutrino interactions, yet they are not considered or reconstructed in most current neutrino liquid argon time projection chamber (LArTPC) physics analyses. In this paper, we present a simulation-based proof-of-concept study of neutron reconstruction in a generic LArTPC detector. Leveraging isolated, MeV-scale energy deposits, or blips, from neutron inelastic scattering, and using realistic blip response from published experimental results, we demonstrate the capability to identify neutrons and to reconstruct the direction and energy of the final-state neutron system in sub-GeV neutrino interactions. We then explore how neutron-related blip attributes can be used to improve physics studies of neutrino interactions, such as enhancing neutrino-antineutrino separation in atmospheric neutrinos and reverse-horn-current beam neutrinos. This study provides an initial quantification of LArTPC neutron reconstruction capabilities, which we expect to improve with future advancements in blip reconstruction, identification, and classification algorithms, as well as the modeling of neutrons.

Morquecho, Miguel Hernandez [Univ. of Minnesota, M↗