SEARCH · Engineering Papers
Results for “Multispectral”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Estimation and analysis of along-track attitude jitter of ZiYuan-3 satellite based on relative residuals of tri-band multispectral imagery
Not Available
Evaluation of Fluence Correction Algorithms in Multispectral Photoacoustic Imaging
Not Available
Mesoscale Battery Science: The Behavior of Electrode Particles Caught on a Multispectral X-ray Camera
Here, functional materials and devices are usually morphologically complex and chemically heterogeneous. Their structures are often designed to be hierarchical because of the desired functionalities, which usually require many different components to work together in a coherent manner. The lithium ion battery, as an energy storage device, is a very typical example of this kind of structure. In a lithium ion battery, the cathode, anode, and separator are soaked in a liquid electrolyte, facilitating the back and forward shuttling of the lithium ions for energy storage and release. The desired performance of a lithium ion battery has many different aspects that need to be engineered and balanced depending on the targeted applications. In most cases, the cathode material has become the limiting factor for further improvements and, thus, has attracted intense attention from the research community.
Isolating the Vibrational Spectra of the Red Chlorophylls in Photosystem I with Multispectral Two-Dimensional Spectroscopy
Photosystem I (PSI) uses an antenna of chlorophyll (Chl) molecules to create a charge separated state with high quantum efficiency. Understanding the charge separation mechanism is currently hindered by spectral overlap between the antenna and reaction center (RC) Chls and the fact that energy transfer and electron transfer occur with similar time scales. Here, we characterize the antenna excited states by applying two-dimensional electronic (2DES) and two-dimensional electronic-vibrational (2DEV) spectroscopy to PSI complexes with closed RCs. Comparison of the 2DES and 2DEV spectra, which evolve with the same kinetics, enabled characterization of the vibrational modes of the antenna during energy equilibration between spectrally distinct Chls. Through global analysis, we learn how energy transfer between the Bulk and Red Chls presents in the 2DEV spectra and we definitively identify vibrations of the cationic components of the mixed exciton and intermolecular charge transfer states associated with the Red Chls. This work enables future studies of the initial charge separation mechanism of PSI by 2DEV spectroscopy.
Electrostatically Doped Silicon Nanowire Arrays for Multispectral Photodetectors
Not provided.
Automatic detection of methane emissions in multispectral satellite imagery using a vision transformer
Curbing methane emissions is among the most effective actions that can be taken to slow down global warming. However, monitoring emissions remains challenging, as detection methods have a limited quantification completeness due to trade-offs that have to be made between coverage, resolution and detection accuracy. Here we show that deep learning can overcome the trade-off in terms of spectral resolution that comes with multi-spectral satellite data, resulting in a methane detection tool with global coverage and high temporal and spatial resolution. We compare our detections with airborne methane measurement campaigns, which suggests that our method can detect methane point sources in Sentinel-2 data down to plumes of 0.01 km 2 , corresponding to 200 to 300 kg CH 4 /h -1 sources. Our model shows an order of magnitude improvement over the state-of-the-art, providing a significant step towards the automated, high resolution detection of methane emissions at a global scale, every few days.
Novel x-ray multispectral imaging of ultraintense laser plasmas by a single-photon charge coupled device based pinhole camera
Spectrally resolved two-dimensional imaging of ultrashort laser-produced plasmas is described, obtained by means of an advanced technique. The technique has been tested with microplasmas produced by ultrashort relativistic laser pulses. The technique is based on the use of a pinhole camera equipped with a charge coupled device detector operating in the single-photon regime. The spectral resolution is about 150 eV in the 4-10 keV range, and images in any selected photon energy range have a spatial resolution of 5 {mu}m. The potential of the technique to study fast electron propagation in ultraintense laser interaction with multilayer targets is discussed and some preliminary results are shown.
Photonic Crystal High-Efficiency Multispectral Thermal Emitters.
Abstract not provided.
Multispectral guided fluorescence diffuse optical tomography using upconverting nanoparticles
We report on improved image detectability for fluorescence diffuse optical tomography using upconverting nanoparticles doped with rare-earth elements. Core-shell NaYF{sub 4}:Yb{sup 3+}/Er{sup 3+}@NaYF{sub 4} upconverting nanoparticles were synthesized through a stoichiometric method. The Yb{sup 3+}/Er{sup 3+} sensitizer-activator pair yielded two anti-Stokes shifted fluorescence emission bands at 540 nm and 660 nm, here used to a priori estimate the fluorescence source depth with sub-millimeter precision. A spatially varying regularization incorporated the a priori fluorescence source depth estimation into the tomography reconstruction scheme. Tissue phantom experiments showed both an improved resolution and contrast in the reconstructed images as compared to not using any a priori information.
Tunable and angle-insensitive plasmon resonances in graphene ribbon arrays with multispectral diffraction response
Plasmon resonances in graphene ribbon arrays are investigated numerically by means of the Finite Element Method. Numerical analysis shows that a series of multipolar resonances take place when graphene ribbon arrays are illuminated by a TM polarized electromagnetic wave. Moreover, these resonances are angle-independent, and can be tuned greatly by the width and the doping level of the graphene ribbons. Specifically, we demonstrate that for graphene arrays with several sets of graphene ribbons, which have different widths or doping levels, each of these multipolar resonances will be split into several ones. In addition, as plasmon resonances can confine electromagnetic field at the ribbon edges, graphene ribbons with different widths or doping levels offer intriguing application for electrically tunable spectral imaging.
MONSTIR II: A 32-channel, multispectral, time-resolved optical tomography system for neonatal brain imaging
We detail the design, construction and performance of the second generation UCL time-resolved optical tomography system, known as MONSTIR II. Intended primarily for the study of the newborn brain, the system employs 32 source fibres that sequentially transmit picosecond pulses of light at any four wavelengths between 650 and 900 nm. The 32 detector channels each contain an independent photo-multiplier tube and temporally correlated photon-counting electronics that allow the photon transit time between each source and each detector position to be measured with high temporal resolution. The system's response time, temporal stability, cross-talk, and spectral characteristics are reported. The efficacy of MONSTIR II is demonstrated by performing multi-spectral imaging of a simple phantom.
Ultrasensitive organic phototransistors with multispectral response based on thin-film/single-crystal bilayer structures
We report on highly efficient organic phototransistors (OPTs) based on thin-film/single-crystal planar bilayer junctions between 5,6,11,12-tetraphenyltetracene (rubrene) and [6,6]-phenyl-C{sub 61}-butyric acid methyl ester (PC{sub 61}BM). The OPTs show good field-effect characteristics in the dark, with high hole-mobility (4–5 cm{sup 2} V{sup −1} s{sup −1}), low-contact resistance (20 kΩ cm), and low-operating voltage (≤5 V). Excellent sensing capabilities allow for light detection in the 400–750 nm range, with photocurrent/dark current ratio as high as 4 × 10{sup 4}, responsivity on the order of 20 AW{sup −1} at 27 μW cm{sup −2}, and an external quantum efficiency of 52 000%. Photocurrent generation is attributed to enhanced electron and hole transfer at the interface between rubrene and PC{sub 61}BM, and fast response times are observed as a consequence of the high-mobility of the interfaces. The optoelectronic properties exhibited in these OPTs outperform those typically provided by a-Si based devices, enabling future applications where multifunctionality in a single-device is sought.
Multispectral and polarimetric photodetection using a plasmonic metasurface
Not Available
CGAP: A Hybrid Contrastive and Graph-Based Active Learning Pipeline to Detect Water and Sediment in Multispectral Images
Not Available