Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Air Quality Monitoring Case Study Using Mobile Low-cost Sensors Mounted on Trash-Trucks: Methods Development and Lessons Learned

Air quality monitoring (AQM) is crucial for cities to develop management plans supporting population health. However, there is a dearth of measurements due to the high cost of standard reference instruments. Mobile AQM using low-cost sensors deployed on routine fleets of vehicles can enable the continuous detection of fine-scale pollutant variations in cities at a lower cost. New methods need to be developed to interpret these measurements. This paper presents three such methods. First, we propose a technique to identify aerosol hotspots. Second, we employ techniques published previously to assess the generalizable map of fine and coarse particle number concentrations, to understand qualitatively the contribution of local and regional sources across the region sampled. By using the raw number concentration of differently sized particles from the Optical Particle Counters (OPCs) instead of the noisier mass concentrations, we obtain more robust results. Third, in order to evaluate source signatures in cities, we propose another technique, in which we cluster the entire range of aerosol size-distribution measurements acquired. The properties of each cluster provide insight into the aerosol source characteristics in the sampling environment. We test these methods using a dataset we collected by mounting OPCs on two trash-trucks in Cambridge, Massachusetts.

Drive-by sensing↗

Air Quality Monitoring Case Study Using Mobile Low-cost Sensors mounted on Trash-Trucks: Methods Development and Lessons Learned

Air quality monitoring (AQM) is crucial for cities to develop management plans supporting population health. However, there is a dearth of measurements due to the high cost of standard reference instruments. Mobile AQM using low-cost sensors deployed on routine fleets of vehicles can enable the continuous detection of fine-scale pollutant variations in cities at a lower cost. New methods need to be developed to interpret these measurements. This paper presents three such methods. First, we propose a technique to identify aerosol hotspots. Second, we employ techniques published previously to assess the generalizable map of fine and coarse particle number concentrations, to understand qualitatively the contribution of local and regional sources across the region sampled. By using the raw number concentration of differently sized particles from the Optical Particle Counters (OPCs) instead of the noisier mass concentrations, we obtain more robust results. Third, in order to evaluate source signatures in cities, we propose another technique, in which we cluster the entire range of aerosol size-distribution measurements acquired. The properties of each cluster provide insight into the aerosol source characteristics in the sampling environment. We test these methods using a dataset we collected by mounting OPCs on two trash-trucks in Cambridge, Massachusetts.

Drive-by sensing↗

Sensitivity evaluation of mounting optics using elastomer and bipod flexures

A sensitivity evaluation of mounting 100mm optics using elastomer or bipod flexures was completed to determine the relative effects of geometry, structure, material, thermal and vibration environment as they relate to optical distortion. This paper covers both opto-mechanical designs, as well as analytical results from computer modeling and brassboard tests.

elasomer↗

Tail-mounted engine Architecture and Design for the Subsonic Single Aft Engine Electrofan Aircraft

This paper describes the turbofan engine architecture for SUbsonic Single Aft eNgine (SUSAN) Electrofan is, a transformative concept hybrid electric aircraft. SUSAN has a single tail-mounted turbofan engine that produces a portion of the requires thrust and drives a 20MW electric generator which in turn provides the power to the 16 electric propulsors located on the wing responsible for producing the remainder of the required thrust. The atypical operation of the turbofan due to the large levels of power extraction from the low pressure turbine (LPT) is described here. This paper investigates the most efficient engine architecture to enable this unique operation, as well as exploring natural gas as an alternative fuel for SUSAN.

EAP↗

Helmet-Mounted Display Technology for Eva Training in NASA's Neutral Buoyancy Lab

Currently, during extravehicular activity (EVA) on the International Space Station (ISS), astronauts are in constant communication with mission control; however, this paradigm will significantly change during future NASA exploration missions due to limited and time-delayed communications. As exploration missions will thereby require an increase in crew autonomy, it is hypothesized that heads-up display (HUD) technology can supplement communications with mission control. Before introducing novel display technology to EVA operations, it must first be demonstrated and evaluated in an EVA training environment. The UC Davis Center for Spaceflight Research, in collaboration with NASA Johnson Space Center’s Human Physiology, Performance, Protection, and Operations (H-3PO) Lab has developed a low-cost and rapid development helmet-mounted display (HMD) for EVA training at NASA’s Neutral Buoyancy Lab (NBL). The first two phases of HMD testing (Phase I and II) at the NBL focused on technology and capability development and demonstration. Crew member feedback was obtained that evaluated aspects of HMD including its user satisfaction, visibility, readability, and usefulness. Overall, feedback indicated HMD was readable, un-obtrusive, and the available display modes had potential to be useful and enhance EVA training. HMD display modes currently available include: real-time biofeedback (metabolic rate), phase elapsed time (PET), ability to set timers, task procedural aids (e.g. Pistol Grip Tool settings) and custom messages. The goal for Phase III, which is currently underway, is to evaluate the effects that access to bioinformatics through HMD has on astronaut training and performance at the NBL. For this phase of testing, crewmembers will be asked to perform a go/no-go task while wearing HMD throughout the NBL run to characterize crew member state of situational awareness with respect to HMD. This information could be used to inform how best to display relatively important or supplemental, but not critical, data in the future.

Heads up display↗

Viral Enumeration Using Cost-Effective Wet-Mount Epifluorescence Microscopy for Aquatic Ecosystems and Modern Microbialites

Enumeration is a fundamental measure of community ecology in which viruses represent the most numerous biological identities. Epifluorescence microscopy (EFM) has been the gold standard method for environmental viral enumeration for over 25 years. Currently, standard EFM methods using the Anodisc filters are no longer cost-effective (>$15 per slide) and have yet to be applied to modern microbialites. Microbialites are microbially driven benthic organosedimentary deposits that have been present for most of Earth’s history. We present a cost-effective method for environ mental viral enumeration from aquatic samples, microbial mats, and exopolymeric substances (EPSs) within modern microbialites using EFM. Our integrated approach, which includes filtration, differential centrifugation, chloroform treatment, glutaralde hyde fixation, benzonase nuclease treatment, probe sonication (EPS and mat only), SYBR Gold staining, wet mounting, and imaging, provides a robust method for modern microbialites and aquatic samples. Viral abundances of modern microbialites and aquatic samples collected from Fayetteville Green Lake (FGL) and Great Salt Lake (GSL) did not differ across ecosystems by sample type. EPS and microbial mat samples had an order of magnitude higher viral-like particle abundance when compared to water regardless of the ecosystem (107 vs 106). Viral enumeration allows for estimates of total viral numbers and weights. The entire weight of all the viruses in FGL and GSL are ~598 g and ~2.2 kg, respectively. Further development of EFM methods and software is needed for viral enumeration. Our method provides a robust and cost-effective (~$0.75 per sample) viral enumeration within modern microbialites and aquatic ecosystems.

Madeline Bellanger↗

Research Needs for Developing Qualification Standards for Flight Simulation Training Devices with Head Mounted Displays

This presentation discusses research needs to support evidence-based qualification standards for Flight Simulation Training Devices (FSTDs) with head mounted displays (HMDs). Currently, the FAA and EASA have no qualification standards specifically for FSTDs using HMDs and extended reality (XR) visuals, and existing qualification standards may not be sufficient. Special Conditions can be prescribed for the evaluation and qualification of individual devices, but these Special Conditions need to be assessed and adjusted on a case-by-case basis resulting in an elaborate process. Furthermore, test tolerances used in Special Conditions are often based on conventional visual systems and may not be adequate. This presentation first identifies gaps in the current knowledge of using HMDs in pilot training, and, more specifically, using HMDs in the training of manual aircraft control with motion cues. Next, research is proposed to help close these gaps, inform the development of qualification criteria and tolerances, and guide efforts to update regulations. The Vertical Motion Simulator (VMS) at NASA Ames Research Center, with its large motion capability, is currently undergoing significant upgrades including a state-of-the-art out-the-window visual system. In addition, an HMD capability will be introduced to use in conjunction with the conventional visual system. With its long history of setting standards in the simulation industry, the VMS is the ultimate tool to conduct research that could help accelerate the development of standards for the use of HMDs in FSTDs. The goal of the talk is ultimately to spark a discussion about the research needs and priorities to best serve the development of new qualification standards.

XR↗

Visual Stability of Objects and Environments Viewed through Head-Mounted Displays

Virtual Environments (aka Virtual Reality) is again catching the public imagination and a number of startups (e.g. Oculus) and even not-so-startup companies (e.g. Microsoft) are trying to develop display systems to capitalize on this renewed interest. All acknowledge that this time they will get it right by providing the required dynamic fidelity, visual quality, and interesting content for the concept of VR to take off and change the world in ways it failed to do so in past incarnations. Some of the surprisingly long historical background of the technology that the form of direct simulation that underlies virtual environment and augmented reality displays will be briefly reviewed. An example of a mid 1990's augmented reality display system with good dynamic performance from our lab will be used to illustrate some of the underlying phenomena and technology concerning visual stability of virtual environments and objects during movement. In conclusion some idealized performance characteristics for a reference system will be proposed. Interestingly, many systems more or less on the market now may actually meet many of these proposed technical requirements. This observation leads to the conclusion that the current success of the IT firms trying to commercialize the technology will depend on the hidden costs of using the systems as well as the development of interesting and compelling content.

virtual environment↗

Mounting for diodes provides efficient heat sink

Efficient heat sink is provided by soldering diodes to metal support bars which are brazed to a ceramic base. Electrical connections between diodes on adjacent bars are made flexible by metal strips which aid in heat dissipation.

Source record↗