Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Numerical method for determination of resonance electron velocities in periodic electric fields

A Monte Carlo method is applied for modeling of a plasma source with a periodic structure of a radiofrequency electric field. The method is modified in order to detect resonance increase of the electron energy at given velocities of the electrons as expected from theoretical considerations. The numerical model is validated by comparison with known analytical results. The applicability of the method for detection of resonance velocities in plasma sources with electric field variation parallel or perpendicular to the electric field vector is proven.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New Developments in Experimental Thermonuclear Reactions

We review new developments regarding experimental thermonuclear reaction rates. First, it is pointed out that published experimental thermonuclear reaction rates have no rigorous statistical meaning. To overcome this problem, we have been working for the past 3 years on a new method of estimating experimental reaction rates by using a Monte Carlo method. Our new reaction rate evaluation for charged-particle reactions on A = 14-40 target nuclei, which is based on this method, has just been completed. With these new reaction rates, many interesting aspects of nucleosynthesis and energy generation can be addressed that were previously not accessible. Second, as an example for a direct measurement, we discuss the recent study of the direct capture component in the {sup 17}O(p,gamma){sup 18}F reaction at our LENA facility. The {sup 17}O+p reactions in classical novae are particularly important for the production of radioactive nuclei (mainly {sup 18}F), for the Galactic origin of {sup 17}O, and for oxygen isotopic ratios in nova presolar grains. Third, as an example for an indirect measurement, we discuss the recent {sup 26}Mg nuclear resonance fluorescence study at our HIgammaS facility. By measuring angular correlations using a linearly polarized gamma-ray beam, we determined the spins and parities of 5 levels near the alpha-particle threshold in {sup 26}Mg. Thus we could substantially reduce the rate uncertainties for the {sup 22}Ne(alpha,n){sup 25}Mg neutron source. Our new reaction rates may have an important impact on the s-process in both massive stars and in AGB stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A space radiation transport method development

Improved spacecraft shield design requires early entry of radiation constraints into the design process to maximize performance and minimize costs. As a result, we have been investigating high-speed computational procedures to allow shield analysis from the preliminary design concepts to the final design. In particular, we will discuss the progress towards a full three-dimensional and computationally efficient deterministic code for which the current HZETRN evaluates the lowest-order asymptotic term. HZETRN is the first deterministic solution to the Boltzmann equation allowing field mapping within the International Space Station (ISS) in tens of minutes using standard finite element method (FEM) geometry common to engineering design practice enabling development of integrated multidisciplinary design optimization methods. A single ray trace in ISS FEM geometry requires 14 ms and severely limits application of Monte Carlo methods to such engineering models. A potential means of improving the Monte Carlo efficiency in coupling to spacecraft geometry is given in terms of re-configurable computing and could be utilized in the final design as verification of the deterministic method optimized design. Published by Elsevier Ltd on behalf of COSPAR.

NASA Center JSC↗

SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation

Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulation (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)

60 APPLIED LIFE SCIENCES↗

Fe and Co nanostructures embedded into the Cu(100) surface: Self-Organization and magnetic properties

The self-organization and magnetic properties of small iron and cobalt nanostructures embedded into the first layer of a Cu(100) surface are investigated using the self-learning kinetic Monte Carlo method and density functional theory. The similarities and differences between the Fe/Cu(100) and the Co/Cu(100) are underlined. The time evolution of magnetic properties of a copper monolayer with embedded magnetic atoms at 380 K is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calculating Control Rod Differential Worth Using Adjoint-Weighted Method

Recently, there are more and more research on using Monte Carlo method to calculate reactor important parameters. Control rod worth is one of the important parameters as it can determine the critical control rod position. There are two presentations of the control rod worth for utilization purpose, integral and differential. The former is the total reactivity change, while the latter is the reactivity change caused by per unit movement. In Monte Carlo calculation, differential control rod worth of a particular position is estimated by finite difference of reactivity between a small gap divided by gap distance. Though easy to implemented, the problem of this approach lies in that too large gap will enlarge error between 'differential' and 'difference', while too small gap will be disturbed by error caused by random fluctuation. Monte Carlo perturbation theory has been used to calculate the k{sub eff} sensitivity to certain parameters for a long time. By calculating the differential coefficient along with the k{sub eff}, this method is quite time-consuming and relatively accurate compared to finite difference method. Nevertheless, most of perturbation research focus on the perturbation of nuclide density or nuclear data. For geometrical perturbation, limited research was done before. Takahashi estimated the k{sub eff} sensitivity to reflector movement of pulsed fast reactor. MCNP6 used adjoint-weighted method for Godiva, Zeus and uranium oxyfluoride solution container benchmarks. This paper tries to apply the perturbation method to the determination of control rod differential worth. In this paper, based on RMC, a continuous-energy Reactor Monte Carlo transport code, Iterated Fission Probability method (IFP) is researched to calculate control rod differential worth on assembly level. IFP was originally developed by Hurwitz, and has been adopted by most of Monte Carlo code to compute adjoint-weighted parameters. This paper is organized with four parts. The first is introduction. Adjoint-weighted method is introduced in the second part. Problem 4 of benchmark from CASL is built to verify the method. Conclusion is given in final part.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transport error estimation using residual Monte Carlo

The residual Monte Carlo (RMC) method is also known in the literature as sequential Monte Carlo and reduced-source Monte Carlo. Given a Monte Carlo method for solving a linear equation and an approximate solution to that system, the residual method enables use of essentially the same Monte Carlo algorithm to directly compute the additive error or “defect” associated with the approximate solution. As the size of the defect decreases relative to the size of the solution, the residual Monte Carlo method becomes increasingly efficient relative to the standard Monte Carlo (SMC) method. Here we present a new RMC algorithm for evaluating the space-angle error in S n radiation transport solutions, and provide computational examples demonstrating that it can be far more efficient than SMC for this purpose. Herein we also describe a particular pitfall that must be avoided if RMC is to be efficient, and explain why the performance of RMC can significantly differ between different transport problems and different quantities of interest for the same problem.

97 MATHEMATICS AND COMPUTING↗

Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 kV. Conclusions: Ranging from 20 kV to 640 kV, 621 x-ray spectra were produced and are available at 1 kV tube potential intervals. The spectra are tabulated at 1 keV intervals. TASMICS spectra were shown to be largely equivalent to published spectral models and are available in spreadsheet format for interested users by emailing the corresponding author (JMB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The multi-element probabilistic collocation method (ME-PCM): Error analysis and applications

Stochastic spectral methods are numerical techniques for approximating solutions to partial differential equations with random parameters. In this work, we present and examine the multi-element probabilistic collocation method (ME-PCM), which is a generalized form of the probabilistic collocation method. In the ME-PCM, the parametric space is discretized and a collocation/cubature grid is prescribed on each element. Both full and sparse tensor product grids based on Gauss and Clenshaw-Curtis quadrature rules are considered. We prove analytically and observe in numerical tests that as the parameter space mesh is refined, the convergence rate of the solution depends on the quadrature rule of each element only through its degree of exactness. In addition, the L{sup 2} error of the tensor product interpolant is examined and an adaptivity algorithm is provided. Numerical examples demonstrating adaptive ME-PCM are shown, including low-regularity problems and long-time integration. We test the ME-PCM on two-dimensional Navier-Stokes examples and a stochastic diffusion problem with various random input distributions and up to 50 dimensions. While the convergence rate of ME-PCM deteriorates in 50 dimensions, the error in the mean and variance is two orders of magnitude lower than the error obtained with the Monte Carlo method using only a small number of samples (e.g., 100). The computational cost of ME-PCM is found to be favorable when compared to the cost of other methods including stochastic Galerkin, Monte Carlo and quasi-random sequence methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction of Fluorescent Images of Biological Tissues for the Effects of Light Absorption and Scattering

A method for correcting the influence of light attenuation processes in biological tissues on their fluorescent images is proposed. The transfer function that takes into account the radiation losses in the medium at the wavelengths of excitation and emission of fluorescence is calculated analytically, depending on the transport scattering index and the hemoglobin tissue index. The latter is determined on the basis of a color image of the tissue in reflected visible light. Verification of the developed method was carried out on the basis of computer simulation of fluorescent images of biological tissue by the Monte Carlo method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical thermalization in particle-in-cell simulations with Monte-Carlo collisions

Numerical thermalization in collisional one-dimensional (1D) electrostatic (ES) particle-in-cell (PIC) simulations was investigated. Two collision models, the pitch-angle scattering of electrons by the stationary ion background and large-angle collisions between the electrons and the neutral background, were included in the PIC simulation using Monte-Carlo methods. The numerical results show that the thermalization times in both models were considerably reduced by the additional Monte-Carlo collisions as demonstrated by comparisons with Turner's previous simulation results based on a head-on collision model [M. M. Turner, Phys. Plasmas 13, 033506 (2006)]. However, the breakdown of Dawson's scaling law in the collisional 1D ES PIC simulation is more complicated than that was observed by Turner, and the revised scaling law of the numerical thermalization time with numerical parameters are derived on the basis of the simulation results obtained in this study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo neutronics analysis of the SNS STS monolith - 25684

Neutronics analysis for the Oak Ridge National Laboratory's Spallation Neutron Source second target station monolith conceptual design was performed entirely with the Monte Carlo method. It has been demonstrated that even though the monolith provides ∼peta-scale attenuation of the dose rates, Monte Carlo simulations are within reach of computing capabilities of relatively inexpensive Linux clusters. Several monolith configurations achieved or exceeded design requirements and provide basis for the final design. (authors)

43 PARTICLE ACCELERATORS↗

Prediction of tissue optical properties using the Monte Carlo modeling of photon transport in turbid media and integrating spheres

Monte Carlo methods are an established technique for simulating light transport in biological tissue. Integrating spheres make experimental measurements of the reflectance and transmittance of a sample straightforward and inexpensive. This work presents an extension to existing Monte Carlo photon transport methods to simulate integrating sphere experiments. Crosstalk between spheres in dual-sphere experiments is accounted for in the method. Analytical models, previous works on Monte Carlo photon transport, and experimental measurements of a synthetic tissue phantom validate this method. We present two approaches for using this method to back-calculate the optical properties of samples. Experimental and simulation uncertainties are propagated through both methods. Both back-calculation methods find the optical properties of a sample accurately and precisely. Our model is implemented in standard Python 3 and CUDA C++ [J. Nickolls, I. Buck, M. Garland, and K. Skadron, ACM Queue 6 , 40 ( 2008 ) ] and is publicly available in Code 1.

Cook, Patrick D. (ORCID:0000000279345428)↗

Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources

Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Monte Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling techniques for quantum cascade lasers

Quantum cascade lasers are unipolar semiconductor lasers covering a wide range of the infrared and terahertz spectrum. Lasing action is achieved by using optical intersubband transitions between quantized states in specifically designed multiple-quantum-well heterostructures. A systematic improvement of quantum cascade lasers with respect to operating temperature, efficiency, and spectral range requires detailed modeling of the underlying physical processes in these structures. Moreover, the quantum cascade laser constitutes a versatile model device for the development and improvement of simulation techniques in nano- and optoelectronics. This review provides a comprehensive survey and discussion of the modeling techniques used for the simulation of quantum cascade lasers. The main focus is on the modeling of carrier transport in the nanostructured gain medium, while the simulation of the optical cavity is covered at a more basic level. Specifically, the transfer matrix and finite difference methods for solving the one-dimensional Schrödinger equation and Schrödinger-Poisson system are discussed, providing the quantized states in the multiple-quantum-well active region. The modeling of the optical cavity is covered with a focus on basic waveguide resonator structures. Furthermore, various carrier transport simulation methods are discussed, ranging from basic empirical approaches to advanced self-consistent techniques. The methods include empirical rate equation and related Maxwell-Bloch equation approaches, self-consistent rate equation and ensemble Monte Carlo methods, as well as quantum transport approaches, in particular the density matrix and non-equilibrium Green's function formalism. The derived scattering rates and self-energies are generally valid for n-type devices based on one-dimensional quantum confinement, such as quantum well structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗