Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applicability for MELCOR Accident Code System (MACCS) to Model the Atmospheric Transport of Biological Contaminants

Characterization of airborne transmission behavior for biological contaminants is a critical aspect in developing public health guidelines in the event of an outbreak. Guidelines such as safe separation distances and physical protections (mask and face-shields) are heavily influenced by the particular biological airborne transmission risk, which depends on a multitude of factors and is not easily or readily determined, therefore potentially lagging behind the time sensitive need to inform effective public health guidelines. Herein is proposed a means to leverage the substantial investment over the last three decades of the Nuclear Regulatory Commission in the MACCS code suite developed at Sandia National Laboratories. This work includes augmenting the MACCS code to represent biological rather than radioactive contaminants in the atmosphere, therefore characterizing the airborne transmission risk for such contaminants and helping to inform critical and time sensitive public health guidelines.

54 ENVIRONMENTAL SCIENCES↗

Practices Implemented by DOE Better Plants Program Partners to Mitigate COVID-19

Screening for symptoms, maintaining physical distance, sanitizing surfaces, wearing appropriate face masks, maintaining good personal hygiene, and reconfiguring HVAC air management are the major activities that the DOE BP partners have implemented to mitigate COVID-19. This article shares some specific practices that BP program partners have implemented for these activities. The energy impact of some practices has also been discussed and some rules of thumb have been provided to estimate energy penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CONFIDANTE Demonstration Prototype Report

This report summarizes design optimization and performance evaluation studies for a new prototype CONFIDANTE (CONfirmation using a Fast-neutron Imaging Detector with Anti-image Null-positive Time Encoding) warhead confirmation system. It was found that a spherical mask geometry and a 2” diameter cylindrical central detector is expected to best discriminate between the parametrically varied source distributions that were evaluated. The optimized design as fabricated and its performance was evaluated in a series of laboratory measurements. The performance was in good agreement with the design studies, with demonstrated discrimination between objects with differences in scale on the order of 5 centimeters or better at 1 meter stand-off

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer Learning using Denoising Auto-Encoders for Cellular-Level Annotation of Tumor in Pathology Slides

Adversarial examples can produce altered classifications using only seemingly innocuous, imperceptible perturbations to the original image. The imperceptibility of adversarial perturbations suggests that the corresponding classifiers use decision criteria different than those of a human. In a medical setting, inexplicable decision criteria confound a pathologist’s willingness to trust machine-generated annotations. Here, we analyze denoising tumor detection models to see if they are robust to imperceptible adversarial perturbations. Moreover, to be more fully trusted by pathologists, we require tumor detectors that generate interpretable annotations which segment pathology slides into tumorous and normal regions at the cellular level. We therefore compare transfer learning based on two different autoencoder architectures, one derived from a deep denoising bottleneck autoencoder and one from an over-complete sparse autoencoder. Both autoencoders were first trained in an unsupervised manner on a set of pathology slides drawn from the Camelyon16 dataset. The latent representations produced by each autoencoder were then passed to separate neural networks that were trained in a supervised manner on binary tumor-normal masks generated by pathologists at cellular resolution. Both tumor detectors supported better than 90% AUC PR as measured by the area under the precision/recall curve on a held-out pathology slide. To assess the underlying decision criteria used by both tumor detectors, we constructed imperceptible adversarial examples which reduced the AUC PR of both models to less than 70%. Random noise of the same amplitude had almost no effect on the AUC PR of either model. Additionally, each tumor detector was resistant to adversarial “transfer” attacks targeting the other. The adversarial perturbations showed strong characteristic differences: the deep denoising models perturbations were a very diffuse, seemingly unrecognizable pattern while the sparse coding models perturbations showed traces of tissue cells.

47 OTHER INSTRUMENTATION↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Spatially and Temporally Resolved Velocimetry for Hypersonic Flows

The development of new hypersonic flight vehicles is limited by the physical understanding that may be obtained from ground test facilities. This has motivated the present development of a temporally and spatially resolved velocimetry measurement for Sandia National Laboratories (SNL) Hypersonic Wind Tunnel (HWT) using Femtosecond Laser Electronic Excitation Tagging (FLEET). First, a multi-line FLEET technique has been created for the first time and tested in a supersonic jet, allowing simultaneous measurements of velocities along multiple profiles in a flow. Secondly, two different approaches have been demonstrated for generating dotted FLEET lines. One employs a slit mask pattern focused into points to yield a dotted line, allowing for two- or three-component velocity measurements free of contamination between components. The other dotted-line approach is based upon an optical wedge array and yields a grid of points rather than a dotted line. Two successful FLEET measurement campaigns have been conducted in SNL’s HWT. The first effort established optimal diagnostic configurations in the hypersonic environment based on earlier benchtop reproductions, including validation of the use of a 267 nm beam to boost the measurement signal-to-noise ratio (SNR) with minimal risk of perturbing the flow and greater simplicity than a comparable resonant technique at 202 nm. The same FLEET system subsequently was reconstituted to demonstrate the ability to make velocimetry measurements of hypersonic turbulence in a realistic flow field. Mean velocity profiles and turbulence intensity profiles of the shear layer in the wake of a hypersonic cone model were measured at several different downstream stations, proving the viability of FLEET as a hypersonic diagnostic.

33 ADVANCED PROPULSION SYSTEMS↗

Wind Plant Performance Prediction Benchmark Phase 1 (Technical Report)

Financial risk resulting from the uncertainty associated with developing, owning, and operating wind power plants remains a barrier to reducing the levelized cost of energy (LCOE). On average, modern wind power plants in the U.S. underperform their expected annual energy output by 3.5-4.5% , with many underperforming by over 10%. To compensate for this uncertainty, investors require a larger return on investment (ROI) and apply "knock-down" factors that mask much of the underlying sources of uncertainty. Wind energy projects thus have reduced access to low-cost capital. Furthermore, operating wind plants often take a simple approach to estimating operations & maintenance (O&M) costs (e.g. straight-line estimates based on similar plants), which can eat into profits. To overcome these issues, the wind industry must improve the models they use for estimating wind plant performance and operations. An industry consortium (IC) requested that the National Renewable Energy Laboratory (NREL) lead a Department of Energy (DOE) working group to benchmark the accuracy of wind power plant energy predictions against real operational data. The IC was also motivated by DOE and NREL's potential to characterize systematic energy underperformance, identify sources of uncertainty, and explore root causes. The Wind Plant Performance Prediction (WP3) project was created out of this request, and this report represents the successful completion of Phase 1 of the WP3 project. During the project, wind plant owners provided both pre-construction and operational data to NREL. The pre-construction data was provided to wind resource assessment (WRA) consultants so they could conduct energy yield assessments (EYA). NREL took all of the completed EYAs, along with the operational data, and conducted an operational assessment to benchmark the EYA results against actual operational data. Given the large amounts of sensitive data required for this effort, as well as historical opposition to sharing data within industry, successful completion of Phase 1 represents an unprecedented milestone for industry data sharing. To improve the accuracy and confidence of pre-construction EYAs, wind plant owners and investors need better, more certain, energy yield predictions. The WP3 Benchmark Project is an industry-driven response to this reality. For the first time, industry has taken the important step of working together at scale, sharing valuable operational data with DOE and NREL in order to investigate the sources of bias and uncertainty in these energy estimates. This IC provides wind plant preconstruction and operational data to NREL in an organized and documented fashion and provides guidance and feedback as needed. The IC also provides introspection of the design of experiment, key metrics of success, data challenges, analysis best practices, and quality of results.

17 WIND ENERGY↗

Photo-cleaned Backgroundless Ion Chambers (Final Report for PDRD SR18010)

Ion chambers are often employed to measure the concentration of tritium within flowing gases. In real world environments the active surfaces of ion chambers become covered with tritiated surface contaminants. This tritiated surface contamination will create a large background response that can mask the signature of interest, which is the tritium concentration in the gas phase. Previous efforts to reduce the effects of surface contamination in ion chambers utilize inert coatings (e.g., gold) and low surface area electrodes (e.g., wire mesh), but this route only reduces the effect and does not necessarily alter the ratio of surface contamination to current collection area. Additionally, gold coating may add a substantial cost to the instrument. In the Tritium Facility, ion chambers are periodically cleaned using an alcohol-based process. This process is time consuming and often leads to ion chamber wear and breakage. In addition, periodic cleaning does not address tritium level ambiguities in gloveboxes. An ideal solution to this issue would be to either develop an ion chamber that does not accrue surface contamination, or one that is self-cleaning while it is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Motional Stark Effect Diagnostic for NSTX-U

This report describes the development of the motional Stark Effect diagnostic for NSTX. The MSE concept relies upon observation of the Balmer-alpha (n=3 to n=2) emission from a neutral hydrogen beam traversing a plasma. As a beam at high velocity, $\vec{ν}$, passes through the magnetic field in the plasma, $\vec{B}$, it experiences in its reference frame a Lorentz electric field, $\vec{E}$ = $\vec{ν}$ x $\vec{B}$. This electric field causes the spectral emission to be split and polarized as described by the Stark effect. The transition is separated into a set of lines in which the line spacing is linearly proportional to the electric field magnitude, and the line polarization is dependent on the electric field direction. Traditionally, MSE has used polarimetry to determine the polarization angle of the light, and related that to the magnetic field pitch angle in the plasma. The MSE diagnostic was developed under high magnetic field ($>$ 1~T) conditions, and the lower fields of recent high-beta experiments such as NSTX posed challenges to the technique. At low magnetic fields Doppler broadening effects mask the Stark effect. With the use of a narrow bandwidth filter MSE measurements at very low magnetic fields have been obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NA-IM TGESC Mobile Device Secure Sled [Slides]

SafeCase provides essential controls such as: 1) Audio masking and 2) camera blocking capabilities if a mobile device has been compromised. This exoskeleton phone case provides a solution in secure spaces at a hardware level providing key attack surface reductions and potential exposures from an audio and visual standpoint.

47 OTHER INSTRUMENTATION↗

Ultra-compact Imaging Technology (CRADA Final Report)

As part of the Cyclotron Road program, Synopic (formerly FlatCam LLC) sought to investigate the benefits of its depth-sensitive imaging techniques. The basic principle involved using a thin mask specially designed to encode light reaching a sensor, in conjunction with optimized computational algorithms, in such a manner that allowed for both miniaturization of imaging systems and improved computation toward high resolution, three-dimensional imaging. By thoroughly exploring the resolution, mask/optical design, and algorithmic capabilities of our depth sensitive technology, we expand the potential applications for (but not limited to) medical, consumer and industrial purposes. The project aimed to develop new imaging systems by building on previous work and using 1) materials capable of modulating and 2) sensors capable of measuring visible and longer wavelengths. Preliminary research was conducted to design, fabricate and characterize imaging systems with the goal of improving resolution, enhancing single capture, three-dimensional imaging, and extending depth of field of captured images. The primary goal was to determine whether adapting the depth-sensitive imaging system is feasible, and early results are promising.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TEAMER: DAISY Flow-noise Testing (Abstract)

Evaluating impacts of marine energy devices is generally difficult given the dynamic environment where these devices need to be placed. The University of Washington’s (UW) DAISY (The Drifting Acoustic Instrumentation SYstem) is designed to measure radiated noise around marine energy converters operating in energetic waves and currents. In currents, a primary limitation for measurement fidelity at low frequencies (< 100 Hz) is the potential for non-propagating “flow-noise” to mask propagating sound and inflate estimates of the radiated noise from marine energy converters at frequencies that overlap with hearing sensitivities of fish and some marine mammals. While free-drifting measurements help to minimize the relative velocity that produces flow-noise, significant levels were still observed during initial DAISY tests. This motivated the development of a fabric “flow shield” around the hydrophone that disrupts both flow-noise generation mechanisms proposed by the initial tests. First, the flow shield is a source of substantial drag which keeps the hydrophone package moving with the approximate velocity of the surrounding water, compensating for differential wind or current forcing on the surface expression. By minimizing relative velocity around the hydrophone, turbulence shed by the hydrophone is also minimized. Second, the flow shield creates a largely quiescent pocket around the hydrophone, minimizing advection of free stream turbulence over the hydrophone element. Field data collected in these experiments will test effectiveness of these flow shields and provide quantitative data use and deployment.

16 TIDAL AND WAVE POWER↗

Compact scalable nanofiber mass production using electrospinning

A low power out put high voltage power supply unit for mass producing thicker nanofiber mat has been built in-house and earned a provisional patent last year. This nanofiber fabrication unit has unique features to produce stand alone thick ceramic nanofiber for specialized application such as isotop production and accelerator targets for high energy physics experiments. This is a versatile unit which can produce wide variety of polymer nanofibers on a semi industrial scale for application in air filtration, face mask, facial beauty pads, gas sensors and many more.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation Based Inference with Domain Adaptation for Strong Gravitational Lensing

Simulation based inference leverages machine learning to carry out Bayesian inference for systems with intractable likelihoods. However, transitioning a network trained on simulated data to real data runs the risk of encountering domain shift, leading to performance losses. We attempt to implement domain adaptation into the sbi neural posterior estimation framework using the Maximum Mean Discrepancy as an additional network loss. We test two network architectures and use masked autoregressive flow for density estimation. We test the network on a set of 400,000 simulated strong gravitational lensing images generated using deeplenstronomy. The source domain is defined as low noise whereas the target domain has a noise profile sampled from experimentally derived DES survey conditions. We find that, while DA does lead to performance improvements, they are marginal at ~6% less inference error. We also find a similar marginal improvement in uncertainty calibration at around 8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Chilled-water Injection at EGS Collab Testbed 2 using the GEOS simulation framework

This work seeks to model the chilled-water injection that occurred at EGS Collab Testbed 2 as part of experiment 3, using the open-source GEOS simulation framework. Modeling of this process, previously conducted using STOMP-GT, confirmed that thermal breakthrough was expected to occur during the chill water injection and may have been masked by strong Joule-Thompsons effects induced by large pressure drops between the fractures and the production wells. Building a GEOS numerical model of this process will allow to include additional physics. In fact, GEOS can model fully coupled thermo-poromechanical processes in fractured porous media and can be employed to model the process of artificially enhancing rock permeability by hydraulically fracturing the rocks. For example, the GEOS model could help understanding the dynamic nature of the EGS collab experiment 3 flow system. Since the limited time and resources do not allow for an extensive study, the focus is on building a baseline model of this process. As such, the main outcomes of this modelling efforts are listed below.

15 GEOTHERMAL ENERGY↗