Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-Assembled BaTiO 3 –Au x Ag 1– x Low-Loss Hybrid Plasmonic Metamaterials with an Ordered “Nano-Domino-like” Microstructure

Metallic plasmonic hybrid nanostructures have attracted enormous research interest due to the combined physical properties coming from different material components and the broad range of applications in nanophotonic and electronic devices. However, the high loss and narrow range of property tunability of the metallic hybrid materials have limited their practical applications. In this study, a metallic alloy-based self-assembled plasmonic hybrid nanostructure, i.e., a BaTiO 3 –Au x Ag 1– x (BTO) vertically aligned nanocomposite, has been integrated by a templated growth method for low-loss plasmonic systems. Comprehensive microstructural characterizations including high-resolution scanning transmission electron microscopy (HRSTEM), energy-dispersive X-ray spectroscopy (EDS), and three-dimensional (3D) electron tomography demonstrate the formation of an ordered “nano-domino-like” morphology with Au 0.4 Ag 0.6 nanopillars as cylindrical cores and BTO as square shells. By comparing with the BTO–Au hybrid thin film, the BTO–Au 0.4 Ag 0.6 alloyed film exhibits much broader plasmon resonance, hyperbolic dispersion, low-loss, and thermally robust features in the UV–vis–NIR wavelength region. This study provides a feasible platform for a complex alloyed plasmonic hybrid material design with low-loss and highly tunable optical properties toward all-optical integrated devices.

36 MATERIALS SCIENCE↗

Enhanced Spatial Mapping of Histone Proteoforms in Human Kidney Through MALDI-MSI by High-Field UHMR-Orbitrap Detection

Core histones including H2A, H2B, H3, and H4 are key modulators of cellular repair, transcription, and replication within eukaryotic cells, playing vital roles within the pathogenesis of disease and cellular responses to environmental stimuli. Traditional mass spectrometry (MS) based bottom-up and top-down proteomics allows for the comprehensive identification of proteins and of post-translational modification (PTM) harboring proteoforms. However, these methodologies have difficulties preserving near cellular spatial distributions because they typically require laser capture microdissection (LCM) and advanced sample preparation techniques. Herein, we coupled matrix-assisted laser desorption/ionization (MALDI) source with a Thermo Scientific Q-Exactive HF Orbitrap MS upgraded with ultra-high mass range (UHMR) boards for the first demonstration of complementary high-resolution accurate mass measurements of proteoforms directly from tissue using this benchtop mass spectrometer. The platform achieved isotopic resolution throughout the detected mass range, providing confident assignments of proteoforms with low ppm mass error and a vastly improved duty cycle over other Fourier transform mass analyzers. Proteoform mapping of core histones was demonstrated on sections of human kidney at near-cellular spatial resolution, with several key distributions of histone and other proteoforms noted within both healthy biopsy and a section from a renal cell carcinoma (RCC) containing nephrectomy. Further, the use of MALDI-MS imaging (MSI) for proteoform mapping demonstrates several steps towards high-throughput accurate identification of proteoforms and provides a new tool for mapping biomolecule distributions throughout tissue sections in extended mass ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distilling nanoscale heterogeneity of amorphous silicon using tip-enhanced Raman spectroscopy (TERS) via multiresolution manifold learning

Abstract Accurately identifying the local structural heterogeneity of complex, disordered amorphous materials such as amorphous silicon is crucial for accelerating technology development. However, short-range atomic ordering quantification and nanoscale spatial resolution over a large area on a-Si have remained major challenges and practically unexplored. We resolve phonon vibrational modes of a-Si at a lateral resolution of <60 nm by tip-enhanced Raman spectroscopy. To project the high dimensional TERS imaging to a two-dimensional manifold space and categorize amorphous silicon structure, we developed a multiresolution manifold learning algorithm. It allows for quantifying average Si-Si distortion angle and the strain free energy at nanoscale without a human-specified physical threshold. The multiresolution feature of the multiresolution manifold learning allows for distilling local defects of ultra-low abundance (< 0.3%), presenting a new Raman mode at finer resolution grids. This work promises a general paradigm of resolving nanoscale structural heterogeneity and updating domain knowledge for highly disordered materials.

36 MATERIALS SCIENCE↗

Oil-Pressure Based Apparatus for In-Situ High-Energy Synchrotron X-Ray Diffraction Studies During Biaxial Deformation

Background: Understanding biaxial loading response at the microstructural level is crucial in helping better design sheet manufacturing processes and calibrate/validate material deformation models. Objective: The objective of this work was to develop a low-cost testing apparatus to probe, with sufficient spatial resolution, the micro-mechanical response of a sheet material in-situ under biaxial loading conditions. Methods: The testing apparatus fabricated as a part of this study operates in a similar fashion to a standard bulge test and uses oil pressure to generate biaxial loading conditions. This biaxial testing apparatus was operated within a synchrotron beamline to characterize the mechanical response of a flash-processed steel sheet using in-situ high-energy X-ray diffraction (XRD) measurements. Further, the GSAS-II package was utilized to develop a workflow for the analysis of the large volume of diffraction data acquired. The workflow was then used to extract the peak position, width, and integrated intensity of the XRD peaks corresponding to the major body-centered cubic phase. Results: The equi-biaxial nature of the loading in the measured area was independently corroborated using experimental (XRD) and simulation (finite element analysis) methods. Furthermore, we discuss the evolution of elastic strain in the major body-centered cubic phase as a function of applied oil pressure and location on the steel sheet. Conclusions: A key advantage of the biaxial apparatus fabricated in this synchrotron study is demonstrated using the results obtained for the flash-processed steel sheet – i.e., mapping the lattice plane-dependent response to biaxial loading for a relatively large sample area in a spatially resolved manner.

36 MATERIALS SCIENCE↗

Atomic-scale characterization of (electro-)catalysts and battery materials by atom probe tomography

To optimise the performance of heterogeneous (electro-)catalysts and battery electrodes, it is essential to establish the structure-property relationships. This can only be achieved by obtaining a full three-dimensional (3D) characterisation of atomic-scale structure and chemistry of these advanced materials. Atom probe tomography (APT) can provide unique insights into 3D elemental distribution, including low atomic mass elements, with sub-nanometer spatial resolution. Despite its superior chemical analytical capability and spatial resolution, APT has limited applications for sustainable energy materials due to technical and analytical challenges. The recent developments in experimental setups, sample preparation methods and data analysis algorithms have opened the door to the possibility of analysing heterogeneous (electro-)catalysts and battery electrodes. This perspective provides an overview of these developments, exemplified by recent achievements of analyzing model heterogeneous model (electro-)catalysts, nanoparticles, zeolites, MOFs and Li-ion battery electrodes, followed by a discussion of limitations, opportunities, and potentials of APT for future scientific exploration.

atom probe tomography↗

Single Molecule Spectroscopy Studies of Acid–Base Chemical Gradients Using Nile Red as a Probe of Local Surface Acidity

Single molecule spectroscopy studies of local acidity along bifunctional acid-base gradients are reported. Gradients are prepared by directional vapor phase diffusion and subsequent reaction of 3-aminopropyl-trimethoxysilane with a uniform silica film. Gradient formation is confirmed by spectroscopic ellipsometry and by static water contact angle measurements. X-ray photoelectron spectroscopy is used to characterize the nitrogen content and degree of nitrogen protonation along the gradient. Nile Red is employed as the probe dye in single molecule spectroscopy studies of these gradients. While Nile Red is well-known for its solvent sensitivity, it is used here, for the first time, to sense the acid/base properties of the film in two-color wide-field fluorescence imaging experiments. The data reveal broad bimodal distributions of Nile Red emission spectra that vary along the gradient direction. The single-molecule results are consistent with solution-phase ensemble acid/base studies of the dye. The former reveal a gradual transition from a surface dominated by basic aminosilane sites at the high-amine end of the gradient to one dominated by acidic silanol sites at the low-amine end. The sub-diffraction-limited spatial resolution afforded by superlocalization of the single molecules reveals spatial correlations in the acid/base properties of the gradient over ~ 200 nm distances. Furthermore, these studies provide data relevant to the use of aminosilane-modified silica in bifunctional, cooperative chemical catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Chemistry↗

Tomography of the rho meson in the QCD instanton vacuum: Transverse momentum dependent parton distribution functions

We analyze the rho meson unpolarized and polarized transverse momentum dependent parton distribution functions (TMDPDFs) in the instanton liquid model (ILM). The corresponding TMDs in ILM are approximated by a constituent quark beam function in the leading Fock state multiplied by a rapidity-dependent factor resulting from the staple-shaped Wilson lines, for fixed longitudinal momentum, transverse separation, and rapidity. At the resolution of the ILM, all of the rho meson TMDs are symmetric in parton 𝑥 for fixed transverse momentum, and Gaussian-like in the transverse momentum for fixed parton 𝑥. The latter is a direct consequence of the profiling of the quark zero modes in the ILM. The evolved TMDs at higher rapidity using the Collins-Soper kernel, and higher resolution using the renormalization group, show substantial skewness towards low parton 𝑥.

Gluons↗

Bolometric Superconducting Optical Nanoscopy (BOSON)

Superconducting transition-edge sensors are renowned for their extraordinary photon sensitivity and energy resolution, finding applications spanning quantum information, astronomy, and nanophotonics. Here, we report the development of bolometric superconducting optical nanoscopy (BOSON), a novel platform that integrates bolometric detection at the superconducting transition edges with near-field optical techniques. BOSON enables the mapping of photoinduced changes in superconductivity with unprecedented spatial resolution and photon sensitivity. By incorporating BOSON with low-dimensional materials, we achieved polariton imaging at nanowatt excitation levels—at least 4 orders of magnitude lower than the power typically required in prior near-field nanoscopy experiments. Our findings highlight the potential for BOSON to advance scanning-probe-based optical platforms to enable the detection of photons, polaritons, and Cooper pair dynamics at the nanoscale. This paves the way for quantum sensing applications using single-polariton detection and can offer deeper insights into quasiparticle dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phonon spectrum in the spin-Peierls phase of CuGeO 3

CuGeO 3 has long been studied as a prototypical example of the spin-Peierls transition in a 𝑆 = 1/2 Heisenberg chain. Despite intensive investigation of this quasi-one-dimensional material, systematic measurements and calculations of the phonon excitations in the dimerized phase have not to date been possible, leaving certain aspects of the spin-Peierls phenomenon unresolved. We perform state-of-the-art density functional theory (DFT) calculations to compute the electronic structure and phonon dynamics in the low-temperature dimerized phase. We also perform high-resolution neutron spectroscopy to measure the full phonon spectrum over multiple Brillouin zones. We find excellent agreement between our numerical and experimental results that extend to all measurement temperatures. Notable features of our phonon spectra include a number of steeply dispersive modes, nonmonotonic dispersion features, and specific phonon anticrossings, which we relate to the mode eigenvectors. By calculating the magnetic interactions within DFT and studying the effects of different phonon modes on the superexchange paths, we discuss the possibility of observing spin-phonon hybridization effects in experiments performed both in and out of equilibrium.

density functional theory↗

Seedless nonresonant gas-flow velocimetry with single-shot coherent Rayleigh-Brillouin scattering

We demonstrate neutral gas-flow velocimetry by exploiting the optical dipole forces exerted by precisely tailored high-intensity laser fields on polarizable particles, in the form of single-shot coherent Rayleigh-Brillouin scattering (CRBS). This enables mapping of the velocity distribution function of the particles in a single laser shot of approximately 200 ns duration, allowing us to perform spectroscopic measurements in the time, rather than the frequency, domain. Importantly, CRBS results in a coherent signal beam, which renders the technique ideal for measurements in optically noisy environments. By correlating the time shift of the resulting spectrum to the Doppler shift caused by the bulk motion of particles, we perform neutral gas-flow velocimetry without the need to seed the flow, nondestructively, for a variety of gases, atomic or molecular. We demonstrate gas-flow velocimetry at flow velocities as low as 1 m ⁢s −1 , with similar velocity resolution, while temperature and gas density can also be estimated from the same single-shot spectra. To prove the effectiveness of the measurement technique, we benchmark it against Pitot tube measurements, which show excellent agreement.

Gerakis, Alexandros [Luxembourg Institute of Scien↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Arasteh, Kourosh [Lawrence Livermore National Labo↗

The Next Generation of MeV Energy X-ray Sources for Use in the Inspection of Additively Manufactured Parts for Industry

In September 2022, we investigated whether we can change the way we perform non-destructive characterization (NDC) of dense, micrometer-scale objects, e.g., additively manufactured (AM) parts, using the BELLA inverse Compton source (ICS). X-ray computed tomography (CT) is the most suitable technique for NDC of these objects, but often requires x-rays with MeV energy for penetration, sub-mm spatial resolution for small structures, a narrow spectrum for low-artifact images, and the ability to tune x ray energy to image a wide range of materials. The BELLA ICS has the unique potential to produce such an x-ray beam with a repetition rate high enough for CT. We scanned a geometric calibration phantom, fabricated by LLNL, a bearing, and an AM part manufactured by Renishaw. We reconstructed the first CT images of their kind. The results are very promising, and LLNL will present our findings at an SPIE conference.

42 ENGINEERING↗

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza↗