Experimental Data Curation at Large Instrument Facilities with Open Source Software

The National Synchrotron Light Source II operating at Brookhaven National Laboratory since 2014 for the US Department of Energy is one of the newest and brightest storage-ring synchrotron facility in the world. NSLS-II, like other facilities, provides pre-processing of the raw data and some analysis capabilities to its users. We describe the research collaborations and open source infrastructure developed at large instrument facilities such as NSLS-II for the purpose of curating high value scientific data along the early stages of the data lifecycle. Data acquisition and curation tasks include storing experiment configuration, detector metadata, raw data acquisition with infrastructure that converts proprietary instrument formats to industry standards. In addition, we describe a specific effort for discovering sample information at NSLS-II and tracing the provenance of analysis performed on acquired images. We show that curation tasks must be embedded into software along the data life cycle for effectiveness and ease of use, and that loosely defined collaborations evolve around shared open source tools. Finally we discuss best practices for experimental metadata capture in such facilities, data access and the new challenges of scale and complexity posed by AI-based discovery for the synthesis of new materials.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Design of the solid cryogen dewar for the Near-Infrared Camera and Multi-Object Spectrometer

A multipurpose, second-generation HST instrument for imaging and spectroscopy in the 1 to 2.5 microns wavelength region is being developed. The Near-Infrared Camera Multi-Object Spectrometer (NICMOS) is unique since it is the only HST instrument operating in the NIR and cryogenically cooled. The NICMOS detector arrays are cooled to 58 K by a solid-nitrogen (SN2) dewar with a predicted lifetime of nearly five years. To obtain this long lifetime, a hybrid cooling approach using thermoelectric coolers (TECs) is employed to reduce the parasitic heat load on the SN2. The design features used to promote long life, the predicted lifetime improvements provided by the TECs, and the performance degradation in the event of TEC failure(s) are discussed.

Oonk, Rodney L.↗

Sensors for Environmental Control

Under a Kennedy Space Center Small Business Innovation Research contract, GEO-CENTERS, Inc. developed a sensing element or 'optrode,' which NASA needed for space life support research to measure a hydroponic culture's pH factor. The company then commercialized the technology in the PC Based pH Monitoring System. The system employs the optrode to enable long term continuous monitoring of the pH level of fluids in standing and flowing conditions, an optoelectronic board with light sensors and detectors that fits into a desktop computer, and a fiber optic cable that connects the two. The system is effective in monitoring the pH output of industries to maintain ranges acceptable to the Environmental Protection Agency.

Source record↗

MoonBEAM: A Beyond Earth-Orbit Gamma-Ray Burst Detector for Multi-Messenger Astronomy

MoonBEAM is a 12U CubeSat concept of deploying gamma-ray detectors in cislunar space to increase gamma-ray burst detections and improve localization precision with the timing triangulation technique. Such an instrument would probe the extreme processes in cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of explore the end of stellar life cycles and black hole formation.

Beyond Earth-Orbit↗

Characterization of image quality and image-guidance performance of a preclinical microirradiator

Purpose: To assess image quality and image-guidance capabilities of a cone-beam CT based small-animal image-guided irradiation unit (micro-IGRT). Methods: A micro-IGRT system has been developed in collaboration with the authors' laboratory as a means to study the radiobiological effects of conformal radiation dose distributions in small animals. The system, the X-Rad 225Cx, consists of a 225 kVp x-ray tube and a flat-panel amorphous silicon detector mounted on a rotational C-arm gantry and is capable of both fluoroscopic x-ray and cone-beam CT imaging, as well as image-guided placement of the radiation beams. Image quality (voxel noise, modulation transfer, CT number accuracy, and geometric accuracy characteristics) was assessed using water cylinder and micro-CT test phantoms. Image guidance was tested by analyzing the dose delivered to radiochromic films fixed to BB's through the end-to-end process of imaging, targeting the center of the BB, and irradiation of the film/BB in order to compare the offset between the center of the field and the center of the BB. Image quality and geometric studies were repeated over a 5-7 month period to assess stability. Results: CT numbers reported were found to be linear (R{sup 2}{>=}0.998) and the noise for images of homogeneous water phantom was 30 HU at imaging doses of approximately 1 cGy (to water). The presampled MTF at 50% and 10% reached 0.64 and 1.35 mm{sup -1}, respectively. Targeting accuracy by means of film irradiations was shown to have a mean displacement error of [{Delta}x,{Delta}y,{Delta}z]=[-0.12,-0.05,-0.02] mm, with standard deviations of [0.02, 0.20, 0.17] mm. The system has proven to be stable over time, with both the image quality and image-guidance performance being reproducible for the duration of the studies. Conclusions: The micro-IGRT unit provides soft-tissue imaging of small-animal anatomy at acceptable imaging doses ({<=}1 cGy). The geometric accuracy and targeting systems permit dose placement with submillimeter accuracy and precision. The system has proven itself to be stable over 2 yr of routine laboratory use (>1800 irradiations) and provides a platform for the exploration of targeted radiation effects in small-animal models.

60 APPLIED LIFE SCIENCES↗

A two-dimensional matrix correction for off-axis portal dose prediction errors

Purpose: This study presents a follow-up to a modified calibration procedure for portal dosimetry published by Bailey et al. ['An effective correction algorithm for off-axis portal dosimetry errors,' Med. Phys. 36, 4089-4094 (2009)]. A commercial portal dose prediction system exhibits disagreement of up to 15% (calibrated units) between measured and predicted images as off-axis distance increases. The previous modified calibration procedure accounts for these off-axis effects in most regions of the detecting surface, but is limited by the simplistic assumption of radial symmetry. Methods: We find that a two-dimensional (2D) matrix correction, applied to each calibrated image, accounts for off-axis prediction errors in all regions of the detecting surface, including those still problematic after the radial correction is performed. The correction matrix is calculated by quantitative comparison of predicted and measured images that span the entire detecting surface. The correction matrix was verified for dose-linearity, and its effectiveness was verified on a number of test fields. The 2D correction was employed to retrospectively examine 22 off-axis, asymmetric electronic-compensation breast fields, five intensity-modulated brain fields (moderate-high modulation) manipulated for far off-axis delivery, and 29 intensity-modulated clinical fields of varying complexity in the central portion of the detecting surface. Results: Employing the matrix correction to the off-axis test fields and clinical fields, predicted vs measured portal dose agreement improves by up to 15%, producing up to 10% better agreement than the radial correction in some areas of the detecting surface. Gamma evaluation analyses (3 mm, 3% global, 10% dose threshold) of predicted vs measured portal dose images demonstrate pass rate improvement of up to 75% with the matrix correction, producing pass rates that are up to 30% higher than those resulting from the radial correction technique alone. As in the 1D correction case, the 2D algorithm leaves the portal dosimetry process virtually unchanged in the central portion of the detector, and thus these correction algorithms are not needed for centrally located fields of moderate size (at least, in the case of 6 MV beam energy).Conclusion: The 2D correction improves the portal dosimetry results for those fields for which the 1D correction proves insufficient, especially in the inplane, off-axis regions of the detector. This 2D correction neglects the relatively smaller discrepancies that may be caused by backscatter from nonuniform machine components downstream from the detecting layer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-207: Comparison of Integrated Tissue Air Ratio (ITAR) to Traditional TAR for Kilovoltage Pencil-Beams

Purpose: Clinically viable depth dose determination in kilovoltage pencil-beams is a great challenge that resulted in a published dosimetry method called ITAR, which involves measurement of air kerma and attenuation with a detector in a low scatter environment coupled with MCNP scatter calculations. The objective of this work is to compare ITAR to traditional TAR using inherently water-proof microchambers that have only recently become commercially available. Methods: An Exradin A26 microchamber was centered 150 mm from a 100 kVp x-ray source with 2 mm aluminum HVL. Depth dose in water from 16 to 24 mm in 2 mm increments was determined by: (1) placing blocks of Plastic Water LR near the source to minimize scatter and using previously published conversion coefficients [ITAR method] and (2) submerging the detector in a water tank with 2 mm thick Plastic Water LR walls and jogging the tank with motor controllers while keeping the detector position fixed [traditional TAR method]. Each method was repeated four to five times. For each repetition, dose was measured free in-air to normalize the data for exponential regression. Results: Traditional TAR indicated higher depth dose than ITAR; differences ranged from 2.1% at 24 mm depth to 2.5% at 16 mm depth. However, the results of traditional TAR did not include a correction for Pq,cham because it is unknown for this detector type in these conditions. It is estimated that the component of Pq,cham due to the effect of water displacement alone is ∼0.94, but Pq,cham is likely several percent larger than 0.94 due to the energy dependency of the microchamber in the presence of low energy scatter that is not present during in-air calibration. Conclusion: The ITAR method remains preferable for clinical depth dose determination in kilovoltage pencil-beams due to Pq,cham being unknown for suitable detectors in relevant conditions. All four of the authors are either current full time employees, which include stock option grants, or consultants of Oraya Therapeutics Inc.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry

Purpose: To investigate a miniature optical dosimeter for real-time, high-resolution dosimetry, and explore its potential applications for in vivo measurements and small field dosimetry. Methods: A micro-sized hemispherical (400 µm radius) scintillating detector was constructed from lanthanide activated phosphors doped with Europium (GOS:Eu) and encapsulated in a 17 gauge plastic catheter. A photon counting PMT and CCD-chip spectrometer were used to detect signals emitted from the detector. A single band-passing spectral approach (630nm) was implemented to discriminate the micro-phosphor optical signal from background signals (Cerenkov radiation) in the optical fiber. To test real-time monitoring capabilities, a 3D-printed phantom was used to detect an 192Ir HDR brachytherapy source at locations ranging from 1 to 4 cm radially and 12 cm along the travel axis of the HDR wire. To test the application of the micro-sized detector for small field dosimetry, the linearity of detector was characterized through irradiation of 6MV photon beam at dose-rates ranging from 100 to 600 MU, and the effect of field size was characterized through detections of beams ranging from 30×30 to 1×1 cm2 size. Results: With a 1 second integration time for the spectrometer, the recorded measurements indicated that the micro-sized detector allowed accurate detection of source position at distances of up to 6 cm along the axis of travel in water. EB measurements showed that the detected signal was linearly correlated with dose rate (R{sup 2} = 0.99). The crossbeam profile was determined with a step size of ∼500 µm. Conclusion: Miniaturization of optical dosimeters is shown to be possible through the construction of lanthanide activated doped phosphors detectors. The small size of the detector makes it amenable to a variety of applications, including real-time dose delivery verification during HDR brachytherapy and EB beam calibrations in small fields.

60 APPLIED LIFE SCIENCES↗

Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields

Purpose: Modern radiotherapy modalities often use small or nonstandard fields to ensure highly localized and precise dose delivery, challenging conventional clinical dosimetry protocols. The emergence of preclinical spatially fractionated synchrotron radiotherapies with high dose-rate, sub-millimetric parallel kilovoltage x-ray beams, has pushed clinical dosimetry to its limit. A commercially available synthetic single crystal diamond detector designed for small field dosimetry has been characterized to assess its potential as a dosimeter for synchrotron microbeam and minibeam radiotherapy. Methods: Experiments were carried out using a synthetic diamond detector on the imaging and medical beamline (IMBL) at the Australian Synchrotron. The energy dependence of the detector was characterized by cross-referencing with a calibrated ionization chamber in monoenergetic beams in the energy range 30–120 keV. The dose-rate dependence was measured in the range 1–700 Gy/s. Dosimetric quantities were measured in filtered white beams, with a weighted mean energy of 95 keV, in broadbeam and spatially fractionated geometries, and compared to reference dosimeters. Results: The detector exhibits an energy dependence; however, beam quality correction factors (k{sub Q}) have been measured for energies in the range 30–120 keV. The k{sub Q} factor for the weighted mean energy of the IMBL radiotherapy spectrum, 95 keV, is 1.05 ± 0.09. The detector response is independent of dose-rate in the range 1–700 Gy/s. The percentage depth dose curves measured by the diamond detector were compared to ionization chambers and agreed to within 2%. Profile measurements of microbeam and minibeam arrays were performed. The beams are well resolved and the full width at halfmaximum agrees with the nominal width of the beams. The peak to valley dose ratio (PVDR) calculated from the profiles at various depths in water agrees within experimental error with PVDR calculations from Gafchromic film data. Conclusions: The synthetic diamond detector is now well characterized and will be used to develop an experimental dosimetry protocol for spatially fractionated synchrotron radiotherapy.

60 APPLIED LIFE SCIENCES↗

Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation

Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.

NASA Discipline Radiation Health↗

Biomolecular solution X-ray scattering at the National Synchrotron Light Source

In recent years there has been a growing interest in the application of X-ray scattering techniques to biomolecules in solution. At NSLS, a new undulator-based beamline, X9, has been constructed to address the oversubscribed user demand for X-ray scattering. Beamline X9 has the capability to perform small/wide-angle X-ray scattering (SAXS/WAXS) all in one single instrument. This is accomplished by utilizing a vacuum sample/detector chamber that is an integral part of the SAXS scattering flight path. This vacuum chamber allows a WAXS detector to be positioned at a close distance from the sample, while not interfering with scattered X-rays at small angles from reaching the SAXS detector. A regular training program, the X9 workbench, has also been established to allow users to become familiar with beamline X9 for solution X-ray scattering.

43 PARTICLE ACCELERATORS↗

239 Pu Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 239 Pu. Fission was induced in a pure 239 Pu (>99%) target using the Godiva IV critical assembly in burst mode. Further, the irradiated sample was transferred to a high-resolution γ-ray detector within 45 minutes. γ-ray list mode data was collected from 45 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. The initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New measurement of double- β decays of Mo 100 to excited states of Ru 100 with the CUPID-Mo experiment

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li 2 100 MoO 4 (LMO) calorimeters each equipped with a Ge light detector (LD) for particle identification. In this work, we present the result of a search for two-neutrino and neutrinoless double beta decays of 100 Mo to the first 0 + and 2 + excited states of 100 Ru using the full CUPID-Mo exposure (2.71 kg yr of LMO). We measure the half-life of 2νββ decay to the $0^+_1$ state as $T^{2ν→0^+_1}_{1/2}$ = (7.5 ± 0.8 (stat.) $^{+0.4}_{-0.3}$ (syst.)) × 10 20 yr. The bolometric technique enables measurement of the electron energies as well as the gamma rays from nuclear de-excitation and this allows us to set new limits on the two-neutrino decay to the $2^+_1$ state of $T^{2ν→2^+_1}_{1/2}$ > 4.4×10 21 yr (90% c.i.) and on the neutrinoless modes of $T^{0ν→2^+_1}_{1/2}$ > 2.1×10 23 yr (90% c.i.), $T^{0ν→0^+_1}_{1/2}$ > 1.2 × 10 23 yr (90% c.i.). Information on the electrons spectral shape is obtained which allows us to make the first comparison of the single state (SSD) and higher state (HSD) 2νββ decay models for the $0^+_1$ excited state of 100 Ru.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Technical Report for "High Energy Physics at The University of Iowa"

Particle Physics explores the very fundamental building blocks of our universe: the nature of forces, of space and time. By exploring very energetic collisions of sub-nuclear particles with sophisticated detectors at the colliding beam accelerators (as well as others), experimental particle physicists have established the current theory known as the Standard Model (SM), one of the several theoretical postulates to explain our everyday world. It explains all phenomena known up to a very small fraction of a second after the Big Bang to a high precision; the Higgs boson, discovered recently, was the last of the particle predicted by the SM. However, many other phenomena, like existence of dark energy, dark matter, absence of anti-matter, the parameters in the SM, neutrino masses etc. are not explained by the SM. So, in order to find out what lies beyond the SM, i.e., what conditions at the earliest fractions of the first second of the universe gave rise to the SM, we constructed the Large Hadron Collider (LHC) at CERN after the Tevatron collider at Fermi National Accelerator Laboratory. Each of these projects helped us push the boundary further with new insights as we explore a yet higher energy regime. The experiments are extremely complex, and as we push the boundaries of our existing knowledge, it also requires pushing the boundaries of our technical knowhow. So, not only do we pursue humankind’s most basic intellectual pursuit of knowledge, we help develop technology that benefits today’s highly technical society. Our trained Ph.D. students become experts at fast computing, manipulation of large data volumes and databases, developing cloud computing, fast electronics, advanced detector developments, and complex interfaces in several of these areas. Many of the Particle physics Ph.D.s build their careers at various technology and computing facilities, even financial institutions use some of their skills of simulation and statistical prowess. Additionally, last but not least, today’s discoveries make for tomorrow’s practical uses of an improved life style, case in point, internet technology, fiber optics, and many such things. At The University of Iowa we are involved in the LHC experiments, ATLAS and CMS, building equipment, with calibration and maintenance, supporting the infrastructure in hardware, software and analysis as well as participating in various aspects of data analyses. Our theory group works on fundamentals of field theories and on exploration of non-accelerator high energy neutrinos and possible dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MoonBEAM: A Beyond Earth-orbit Gamma-ray Burst Detector for Multi-Messenger Astronomy

MoonBEAM is a SmallSat concept of deploying gamma-ray detectors in cislunar space to increase gamma-ray burst detections and improve localization precision with the timing triangulation technique. Such an instrument would probe the extreme processes involved in the cosmic collision of compact objects and facilitate multi-messenger time-domain astronomy to explore the end of explore the end of stellar life cycles and black hole formation.

Hui, Chiumun M.↗

Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and {sup 60}Co γ-rays

Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference {sup 60}Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a {sup 60}Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to {sup 60}Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2–40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. Conclusions: The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and {sup 60}Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.

60 APPLIED LIFE SCIENCES↗

SU-E-T-494: A MOSFET-Based In-Vivo Dosimetry System for MR Image-Guided Radiation Therapy (MR-IGRT)

Purpose: To determine if a MOSFET based in-vivo dosimetry system can be used for patients undergoing MR-IGRT. Methods: Standard and high sensitivity MOSFET detectors were used for in-field and out-of-field measurements respectively. The systems were benchmarked and calibrated against a calibrated ionization chamber on a standard 6 MV linear accelerator, and then on the MR-IGRT system. Known doses were delivered to a water phantom with the MOSFETs placed between the top of the phantom and underneath a layer of bolus and water equivalent plastic, using a 6 MV beam and a {sup 6} {sup 0}Co MR-IGRT beam. The latter was performed with and without real-time MRI-guidance during the beam delivery (MRIGRT). Results: The in-field dosimeter response was linear from 50-500 cGy with little evidence of energy dependence or change in response due to the permanent static magnetic field of the MR-IGRT system. The detector response varied by < 2% between 6 MV and {sup 6} {sup 0}Co without image guided delivery. The out-of-field dosimeter response was linear from 1-50 cGy; however the detectors did display dose rate and energy dependence as the response varied by > 20% depending on distance from isocenter used during calibration. Therefore, to use the dosimeters for out-of-field measurements they must be calibrated out-of-field. Regardless of the detector orientation in the coronal plan, the response of the MOSFETs during MRI-guided delivery increased by 5% due to induced currents from the dynamic magnetic field present with image guidance. During the MRI-guided delivery, some loss in image quality was seen when the MOSFETs were present in the imaging plane. This was mitigated by using a handheld reader without a transmitting wireless receiver. Conclusion: A MOSFET-based in-vivo dosimetry system can be used for patients receiving MR-IGRT; however the change in detector response due to the dynamic magnetic field requires a special calibration.

07 ISOTOPE AND RADIATION SOURCES↗