Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Low RF Power Plasma Ignition and Detection for In-Situ Cleaning of 1.3 GHz 9-Cell Cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Lab- oratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomod-ules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

43 PARTICLE ACCELERATORS↗

Advanced Control Methods for Particle Accelerators (ACM4PA) 2019

Los Alamos is currently developing novel particle accelerator controls and diagnostics algorithms to enable higher quality beams with lower beam losses than is currently possible. The purpose of this workshop was to consider tuning and optimization challenges of a wide range of particle accelerators including linear proton accelerators such as the Los Alamos Neutron Science Center (LANSCE), rings such as the Advanced Photon Source (APS) synchrotron, free electron lasers (FEL) such as the Linac Coherent Light Source (LCLS) and LCLS-II, the European X-ray Free Electron Laser (EuXFEL), the Swiss FEL, and the planned MaRIE FEL, and plasma wake- eld accelerators such as FACET, FACET-II, and AWAKE at CERN. One major challenge is an the ability to quickly create very high quality, extremely intense, custom current and energy pro le beams while working with limited real time non-invasive diagnostics and utilizing time-varying uncertain initial beam distributions and accelerator components. Currently, a few individual accelerator labs have been developing and applying their own diagnostics tools and custom control and ML algorithms for au- tomated machine tuning and optimization. The goal of this workshop was to bring together a group of accelerator physicists and accelerator related control and ML experts in order to de ne which controls and diagnostics would be most useful for existing and future accelerators and to create a plan for developing a new family of algorithms that can be shared and maintained by the community.

43 PARTICLE ACCELERATORS↗

SRF Cavity R&D - Enabling New Frontiers in High Energy Physics and Quantum Science

Advances in SRF research at Fermilab have potential for impact in a wide variety of scientific fields: High energy physics (e.g. PIP-II, proposed colliders), basic energy sciences (e.g. LCLS-II, LCLS-II HE), nuclear physics (e.g. proposed MaRIE, EIC), Quantum Science (see quantum lab for details), dark matter searches (e.g. ADMX g-2), and industrial particle accelerators for wastewater treatment, cancer treatment, isotope production, and more.

43 PARTICLE ACCELERATORS↗

Pressure-induced complexity in dynamically compressed calcium

In this project we studied the series of structural phase transitions that occurs in the alkali earth metal Ca as it transforms to increasingly complex arrangements with pressure. The experiments were designed specifically for the ultra-bright X-ray source of the LCLS and the optical capabilities of the MEC nanosecond drive laser. We studied in detail the unusual structural behavior near the minimum of Ca’s melt curve along the Hugoniot and investigated possible metastable phase formation as an explanation for large discrepancies in pressure-volume data from previous shock and static experiments. In total 200 data shots were taken. Using the laser pulse shaping capabilities for the MEC nanosecond laser permitted two thermodynamic compression paths to be explored: (i) Along the principal Hugoniot within the solid and liquid phases, (ii) along a double-shock path to access a cooler P-T compression path within the solid state. Probing the compressed Ca sample with the LCLS XFEL permitted structural determination of the Ca through x-ray diffraction. Pressure was determined with Doppler Interferometry (MEC VISAR diagnostic) and the known equation-of-state of Ca. These data represent the first direct measurements of lattice level rearrangement in Ca under shock compression. We observe the onset of melt, structure within the liquid and an evolution of crystal structure along off-Hugoniot paths up to 100 GPa. These experiments yield important insights into non-equilibrium phase formation under dynamic loading and the deviation away from nearly free electron like behavior, which has been found to be ubiquitous among the elements.

36 MATERIALS SCIENCE↗

New Physics in the Hot Electron Furnace (Final Report)

The primary purpose of this award was experiments and simulations related to the idea of a ‘Hot Electron Furnace’ where nonlocal heat transport would allow unique new experimental opportunities at x-ray free electron lasers. The period of this award included beamtime at the MEC endstation of the LCLS, and the execution of those experiments was a primary goal. Unfortunately, the beamtime had limited success due to (1) inability of the LCLS to deliver the expected two-color operations mode, and (2) failure of the MEC endstation’s own software to save the cavity timing data that would have allowed inference of time delays for the few hours when two-color mode briefly operated. The beamtime was then switched to operate in single-color (one pulse) mode, and studies were performed of x-ray heating and probe, simultaneously. Two interesting manuscripts are finally near submission, having been delayed by student graduations, need for collaborator simulations of x-ray heating processes, and then COVID. I am hopeful that they will soon be submitted (especially the paper on x-ray heating of MgO) because one of the principal students involved has returned from industry to take a postdoc position at SLAC. Below, we first list all publications and other work products (including the two that are nearing submission) and then summarize several outcomes from this effort. During the term of this award three UW physics graduate students were at least partially supported, and all three received their Ph.D.’s with significant components of their supported work in the dissertation.

47 OTHER INSTRUMENTATION↗

Deep learning reconstruction of attosecond X-ray pulses from an angularly streaked 2D photoelectron momentum distribution

The Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory produces intense X-ray pulses using a beam of accelerated electrons. The X-ray laser enhanced attosecond pulse generation (XLEAP) project at SLAC has enabled LCLS to produce much shorter X-ray pulses than previously possible, with durations of a few hundred attoseconds. To measure the time-profile of these extremely short pulses a velocity map imaging spectrometer (VMI) was developed. The pulse duration is measured with using an angular streaking method.

Franz, Paris↗

Matter in Extreme Conditions Upgrade (Conceptual Design Report)

The Linac Coherent Light Source (LCLS) X-ray Free Electron Laser (XFEL) is an open-access user facility that delivers ultrashort X-ray pulses that are nine orders of magnitude brighter than any prior source, able to probe the characteristics of matter with unprecedented spatial and temporal precision. The Matter in Extreme Conditions (MEC) instrument at LCLS combines the XFEL with high-power, short-pulse lasers to produce and study high energy density (HED) plasmas to develop the fundamental understanding of plasmas and matter in extreme environments. This has driven a remarkably rich array of high-profile scientific results with applications in fusion energy, isotope production, advanced materials, and medical and nuclear technology. The Matter in Extreme Conditions Upgrade (MEC-U) Project proposes a major upgrade to MEC that would significantly increase the power and repetition rate of the high intensity laser system to the petawatt level (PW, 10 15 Watts) at 10 Hz, increase the energy of the shock-driver laser to the kilojoule level (kJ), and expand the capabilities of the MEC instrument to support groundbreaking experiments enabled by the combination of high-power lasers with the world’s brightest X-ray source.

36 MATERIALS SCIENCE↗

RF Accelerator Technology R&D: Report of AF7-rf Topical Group to Snowmass 2021

Accelerator radio frequency (RF) technology has been and remains critical for modern high energy physics (HEP) experiments based on particle accelerators. Tremendous progress in advancing this technology has been achieved over the past decade in several areas highlighted in this report. These achievements and new results expected from continued R&D efforts could pave the way for upgrades of existing facilities, improvements to accelerators already under construction (e.g., PIP-II), well-developed proposals (e.g., ILC, CLIC), and/or enable concepts under development, such as FCC-ee, CEPC, C 3 , HELEN, multi-MW Fermilab Proton Intensity Upgrade, future Muon Colloder, etc. Advances in RF technology have impact beyond HEP on accelerators built for nuclear physics, basic energy sciences, and other areas. Recent examples of such accelerators are European XFEL, LCLS-II and LCLS-II-HE, SHINE, SNS, ESS, FRIB, and EIC. To support and enable new accelerator-based applications and even make some of them feasible, we must continue addressing their challenges via a comprehensive RF R&D program that would advance the existing RF technologies and explore the nascent ones.

43 PARTICLE ACCELERATORS↗

Theory and Simulation of Ultrafast Multidimensional Nonlinear X-ray Spectroscopy of Molecules (Final Report)

Emerging X-ray free electron laser (XFEL) beam sources offer new types of probes of matter with unprecedented spatial and temporal resolutions. These experimental advances must be met by robust theoretical and computational tools that provide predictive modeling capacity of the underlining electronic and structural dynamics. The latter will be essential for the design of sophisticated multi-pulse experiments and for their interpretation. The proposed research effort will focus on developing cutting- edge simulation tools for nonlinear multidimensional X-ray/optical spectroscopies and aims to address key questions in Priority Research Opportunities 1 (Probing and controlling electron motion within a molecule) and 3 (Capturing rare events and intermediate states in the transformation of matter) as mentioned in the BES Roundtable Report “Opportunities for Basic Research at the Frontiers of XFEL Ultrafast Science”. XFEL multidimensional nonlinear techniques, which combine sequences of X-ray and possibly optical pulses, provide a unique experimental toolbox for probing the dynamics of core and valence electronic excitations, as well as material structure. Predictive modeling of these dynamical processes requires the combination of analytical theory for nonlinear interactions of light and matter, robust quantum-chemical methodologies for the accurate description of electronic structure of various materials, and multiscale ab initio electron and nuclear dynamics techniques operating beyond Born-Oppenheimer approximation. These challenges will be addressed with three research thrusts (i) Develop and implement theoretical apparatus for modeling a broad range of multidimensional spectroscopic techniques enabled by present and upcoming XFEL facilities. This thrust also includes the incorporation of a computational module in the DOE supported open-source NWChem computational chemistry package as well as the development of other open-source codes ready for dissemination across a broad user base; (ii) Propose and design new multi-pulse experiments that make use of the capabilities of the incoming LCLS-II facility; (iii) Perform selected applications to specific molecular systems that can be carried out at LCLS-II and demonstrate how these X-ray sources may be used to study nonadiabatic dynamics through conical interactions, electronic correlations in multi-core excitons, and charge transfer/energy transfer processes. The proposed research will be carried out by a multi-disciplinary four-institution research team which combines academia and national laboratories and spans the broad and necessary expertise in theoretical spectroscopy, nonlinear optics, quantum chemistry, molecular non-adiabatic dynamics and code development. The work will be performed in a highly interactive team environment with junior researchers shared between institutions thus cementing cross- disciplinary interactions. The developed simulation tools will be immediately deployed for XFEL facility users, both experimentalists and theorists, via freely distributed codes and databases. Altogether, this project will facilitate establishing XFEL-based multidimensional spectroscopies as a novel diagnostic tool for monitoring electronic and structural dynamics in molecular materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lessons learned from nitrogen doping at JLab - Exploration of surface resistance and quench field trade-offs with varied interstitial atom diffusion of niobium cavity surfaces

Interstitial diffusion of atomic species into the surface of niobium has been found to yield significantly reduced srf surface resistance and lowered quench fields. This talk summarizes systematic efforts to explore the trade-offs of these phenomena with a goal of learning how to maximize Q0 in the 30 MV/m regime. The talk also summarizes N-doped cavity progress at JLab for LCLS-II. This work is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177 and by the LCLS-II Project under DE-AC02-76SF00515.

Palczewski, Ari↗

Materials Science of the Interstitial Doping Process

Particle accelerators are an increasingly important tool for frontier science. Growing initial and operating costs are a significant barrier for upgrades and for new machines. While everything matters, the major cost contributor is the SRF cavities and their ancillary facilities (e.g., cryoplant). Accordingly, the accelerator science community devotes much R&D effort to improving their energy efficiency (increased Q o ) and gradient (E acc ). While improved gradient is at the forefront for certain machines (ILC), improved quality factor has broader impact, benefitting all SRF applications. An important opportunity for accelerator science and technology to move forward arose in the course of building the LCLS-II, the second generation Linac Coherent Light Source at SLAC. At more or less the same time, researchers at Fermilab discovered that introducing a small amount of nitrogen to the niobium surface could improve the mid-range quality factor as much as three-fold. A firm resolution of how nitrogen confers its benefit attracts much current research interest. The key elements of the “nitrogen doping” process were vacuum bake at 800 °C, brief exposure to mTorr of nitrogen at several hundred degrees followed by electropolish (EP) to remove several microns from the surface to eliminate unwanted nitrides: While the process as a whole was novel, the comprising unit operations are familiar to the accelerator community. It was judged reasonable to adopt it as a cost-reduction technology for LCLS-II. Researchers carried out a program of varying process parameters and measuring performance in single-cell cavities, leading to a consensus stable protocol for the project. The transition to vendor fabrication and multiple niobium sources has presented unforeseen challenges of performance variation evidently not connected to anything that could be incorporated in a purchase specification. Moving beyond the high temperature N-doping process above, researchers reported a simplified process consisting entirely of tens of hours anneal in a N atmosphere at low temperatures (~120°C – 160°C) after 800 °C UHV bake. These processes typically yield a few-nm doped layer while the high temperature process yields at least a few to many micron doped layer. Even more recently, oxygen has been used to dope instead of nitrogen which leaves a few-µm O-alloyed layer upon vacuum annealing for 300 °C for ~3 hours. The investigation of these materials is just beginning, but the process simplification they may offer is surely attractive. The very low quantity of material that appears to be significant in the “infusion” process indicates the need for very careful control of gas species available for diffusion into the surface during low temperature treatment, both for process control and research to characterize the underlying dynamics. Oxygen alloying offers the further opportunity to utilize the decomposition of the surface native oxide as the dopant source. It is necessary to understand and (thus) manage this process. We have been supported by the Department of Energy Offices of High Energy Physics and Nuclear Physics to pursue this goal.

36 MATERIALS SCIENCE↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

Undulator Changes Due To Temperature Excursions

The temperature of the LCLS undulators has not been controlled during storage. The effects of the temperature excursions are documented in this note. After a number of LCLS undulators were tuned, fiducialized, and placed in storage anticipating their use, a test was made to ensure that their properties had not changed. The test revealed, however, that indeed the undulators had changed. Detailed study of this problem followed. We now believe that the gap of the undulators changes permanently when the undulators go through temperature excursions. We have tested the other possible cause, transportation, and do not see gap changes. In this note, we document how the undulators have changed since they were originally tuned. The undulators were tuned and fiducialized in the Magnetic Measurement Facility (MMF). Afterward, many of them (approximately 18) were taken to building 750 for storage during summer and fall 2007. Building 750 had no temperature control. The undulator temperatures went from 20 C, used for tuning, down to approximately 11 C during the winter. In January 2008, three of the undulators were brought back to the MMF for a check. All three undulators showed similar changes. Trajectories, phases, and most undulator properties stayed the same, but the fiducialization (beam axis position relative to tooling balls on the undulator) had changed. Further investigation showed that the undulator gap was altered in a periodic way along the magnetic axis with a net average gap change causing the fiducialization change. A new storage location in building 33 was found and future undulators were placed there. A failure in the temperature control, however, caused the undulators to get too hot. Again the gap changed, but with a different periodic pattern. This note documents the measured changes in the undulators. In particular, it shows the detailed history of undulator 39 which went through both negative and positive temperature excursions.

43 PARTICLE ACCELERATORS↗

RF Processing Experience with the GTF Prototype RF Gun

The SSRL Gun Test Facility (GTF) was built to develop a high brightness electron injector for the LCLS and has been operational since 1996. A total of five different metal cathodes (4 Cu and 1 Mg) have been installed on the GTF gun. The rf processing history with the different cathodes will be presented including peak field achieved at the cathode. The LCLS gun is intended to operate at 120 MV/m and fields up to 140 MV/m have been achieved in the GTF gun. After installing a new cathode the number of rf pulses required to reach 120 MV/m is approximately 5-10 million. Total emitted dark current and Fowler Nordheim plots are also shown over the life of the cathode. The GTF photo-injector gun is an S-band standing-wave structure, with two resonant cavities and an intervening thick washer (Figure 1). The flat, back wall of the first cavity is a copper plate that serves as photocathode when illuminated with ultraviolet light from a pulsed, high-power laser. RF power enters the gun through an iris on the outer wall of the second cavity, and is coupled to the first through the axial opening of the washer. The first cavity is often referred to as a half cell, because its full-cell length has been truncated by the cathode plate and the second cavity is called the full cell. The gun is designed to operate in a {pi} mode, with the peak field on axis in each cell approximately equal. The maximum in the half cell occurs at the cathode, and in the full cell near the center of the cavity. The field profile and tuning procedures are discussed in a separate tech note [1].

43 PARTICLE ACCELERATORS↗

Undulator Beam Pipe Magnetic Shielding Effect Tests

The proposed stainless steel beampipe for the LCLS undulator has a measurable shielding effect on the magnetic field of the LCLS undulators. This note describes the tests used to determine the magnitude of the shielding effect, as well as deviations in the shielding effect caused by placing different phase shims in the undulator gap. The effect of the proposed Steel strongback which will be used to support the beam pipe, was also studied. A hall probe on a 3 axis movement system was set up to measure the main component of the magnetic field in the Prototype Undulator. To account for temperature variations of the magnetic field of the undulator for successive tests, a correction is applied which is described in this technical note. Using this method, we found the shielding effect, the amount which the field inside the gap was reduced due to the placement of the beampipe, to be {approx}10 Gauss. A series of tests was also performed to determine the effect of phase shims and X and Y correction shims on the shielding. The largest effect on shielding was found for the .3 mm phase shims. The effect of the .3 mm phase shims was to increase the shielding effect {approx}4 Gauss. The tolerance for the shielding effect of the phase shims is less than 1 gauss. The effect of the strongback was seen in its permanent magnetic field. It introduced a dipole field across the measured section of the undulator of {approx}3 gauss. This note documents the tests performed to determine these effects, as well as the results of those tests.

36 MATERIALS SCIENCE↗

Tuning The Laser Heater Undulator

The laser heater undulator for the LCLS requires different tuning techniques than the main undulators. It is a pure permanent magnet (PPM) undulator, rather than the hybrid design of the main undulators. The PPM design allows analytic calculation of the undulator fields. The calculations let errors be introduced and correction techniques be derived. This note describes how the undulator was modelled, and the methods which were found to correct potential errors in the undulator. The laser heater undulator for the LCLS is a pure permanent magnet device requiring different tuning techniques than the main undulators. In this note, the laser heater undulator is modelled and tuning techniques to compensate various errors are derived.

43 PARTICLE ACCELERATORS↗

ExaFEL: extreme-scale real-time data processing for X-ray free electron laser science

ExaFEL is an HPC-capable X-ray Free Electron Laser (XFEL) data analysis software suite for both Serial Femtosecond Crystallography (SFX) and Single Particle Imaging (SPI) developed in collaboration with the Linac Coherent Lightsource (LCLS), Lawrence Berkeley National Laboratory (LBNL) and Los Alamos National Laboratory. ExaFEL supports real-time data analysis via a cross-facility workflow spanning LCLS and HPC centers such as NERSC and OLCF. Our work therefore constitutes initial path-finding for the US Department of Energy's (DOE) Integrated Research Infrastructure (IRI) program. We present the ExaFEL team's 7 years of experience in developing real-time XFEL data analysis software for the DOE's exascale supercomputers. We present our experiences and lessons learned with the Perlmutter and Frontier supercomputers. Furthermore we outline essential data center services (and the implications for institutional policy) required for real-time data analysis. Finally we summarize our software and performance engineering approaches and our experiences with NERSC's Perlmutter and OLCF's Frontier systems. This work is intended to be a practical blueprint for similar efforts in integrating exascale compute resources into other cross-facility workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Seventh User Workshop on High-Power Lasers at the Linac Coherent Light Source

We report on a seventh annual workshop in a series focused on science realized by the combination of hard X-ray free electron lasers with high power optical lasers, hosted at the SLAC National Accelerator Laboratory in Menlo Park, CA. Members from the user community of the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source (LCLS) and other scientists met with local scientists to discuss developments at LCLS and MEC and related facilities, including experimental results and future plans.

47 OTHER INSTRUMENTATION↗