Plasmaspheric H+, He+, O+, He++, and O++ Densities and Temperatures

Thermal plasmaspheric densities and temperatures for five ion species have recently become available, even though these quantities were derived some time ago from the Retarding Ion Mass Spectrometer onboard the Dynamics Explorer 1 satellite over the years 1981-1984. The quantitative properties will be presented. Densities are found to have one behavior with lessor statistical variation below about L=2 and another with much greater variability above that Lshell. Temperatures also have a behavior difference between low and higher L-values. The density ratio He++/H+ is the best behaved with values of about 0.2% that slightly increase with increasing L. Unlike the He+/H+ density ratio that on average decreases with increasing Lvalue, the O+/H+ and O++/H+ density ratios have decreasing values below about L=2 and increasing average ratios at higher L-values. Hydrogen ion temperatures range from about 0.2 eV to several 10s of eV for a few measurements, although the bulk of the observations are of temperatures below 3 eV, again increasing with L-value. The temperature ratios of He+/H+ are tightly ordered around 1.0 except for the middle plasmasphere between L=3.5 and 4.5 where He+ temperatures can be significantly higher. The temperatures of He++, O+, and O++ are consistently higher than H+.

Gallagher, D. L.↗

Plasmaspheric H+, He+, He++, O+, and O++ Densities and Temperatures

Thermal plasmaspheric densities and temperatures for five ion species have recently become available, even though these quantities were derived some time ago from the Retarding Ion Mass Spectrometer onboard the Dynamics Explorer 1 satellite over the years 1981-1984. The quantitative properties will be presented. Densities are found to have one behavior with lessor statistical variation below about L=2 and another with much greater variability above that Lshell. Temperatures also have a behavior difference between low and higher L-values. The density ratio He++/H+ is the best behaved with values of about 0.2% that slightly increase with increasing L. Unlike the He+/H+ density ratio that on average decreases with increasing Lvalue, the O+/H+ and O++/H+ density ratios have decreasing values below about L=2 and increasing average ratios at higher L-values. Hydrogen ion temperatures range from about 0.2 eV to several 10s of eV for a few measurements, although the bulk of the observations are of temperatures below 3 eV, again increasing with L-value. The temperature ratios of He+/H+ are tightly ordered around 1.0 except for the middle plasmasphere between L=3.5 and 4.5 where He+ temperatures can be significantly higher. The temperatures of He++, O+, and O++ are consistently higher than H+.

Gallagher, G. L.↗

Comparison of Martian Surface Radiation Predictions to the Measurements of Mars Science Laboratory Radiation Assessment Detector (MSL/RAD)

For the analysis of radiation risks to astronauts and planning exploratory space missions, detailed knowledge of particle spectra is an important factor. Detailed measurements of the energetic particle radiation environment on the surface of Mars have been made by the Mars Science Laboratory Radiation Assessment Detector (MSL-RAD) on the Curiosity rover since August 2012, and particle fluxes for a wide range of ion species (up to several hundred MeV/u) and high energy neutrons (8 - 1000 MeV) have been available for the first 200 sols. Although the data obtained on the surface of Mars for 200 sols are limited in the narrow energy spectra, the simulation results using the Badhwar-O'Neill galactic cosmic ray (GCR) environment model and the high-charge and energy transport (HZETRN) code are compared to the data. For the nuclear interactions of primary GCR through Mars atmosphere and Curiosity rover, the quantum multiple scattering theory of nuclear fragmentation (QMSFRG) is used, which includes direct knockout, evaporation and nuclear coalescence. Daily atmospheric pressure measurements at Gale Crater by the MSL Rover Environmental Monitoring Station are implemented into transport calculations for describing the daily column depth of atmosphere. Particles impinging on top of the Martian atmosphere reach the RAD after traversing varying depths of atmosphere that depend on the slant angles, and the model accounts for shielding of the RAD by the rest of the instrument. Calculations of stopping particle spectra are in good agreement with the RAD measurements for the first 200 sols by accounting changing heliospheric conditions and atmospheric pressure. Detailed comparisons between model predictions and spectral data of various particle types provide the validation of radiation transport models, and thus increase the accuracy of the predictions of future radiation environments on Mars. These contributions lend support to the understanding of radiation health risks to astronauts for the planning of various mission scenarios.

Kim, Myung-Hee Y.↗

Multidirectional Cosmic Ray Ion Detector for Deep Space CubeSats

Understanding the nature of anisotropy of solar energetic protons (SEPs) and galactic cosmic ray (GCR) fluxes in the interplanetary medium is crucial in characterizing time-dependent radiation exposure in interplanetary space for future exploration missions. NASA Glenn Research Center has proposed a CubeSat-based instrument to study solar and cosmic ray ions in lunar orbit or deep space. The objective of Solar Proton Anisotropy and Galactic cosmic ray High Energy Transport Instrument (SPAGHETI) is to provide multi-directional ion data to further understand anisotropies in SEP and GCR flux. The instrument is to be developed using large area detectors fabricated from high density, high purity silicon carbide (SiC) to measure linear energy transfer (LET) of ions. Stacks of these LET detectors are arranged in a CubeSat at orthogonal directions to provide multidirectional measurements. The low-noise, thermally-stable nature of silicon carbide and its radiation tolerance allows the multidirectional array of detector stacks to be packed in a 6U CubeSat without active cooling. A concept involving additional coincidence/anticoincidence detectors and a high energy Cherenkov detector is possible to further expand ion energy range and sensitivity.

Extraterrestrial Radiation↗

Wave Telescope Technique for MMS Magnetometer

Multipoint measurements are a powerful method in studying wavefields in space plasmas.The wave telescope technique is tested against magnetic field fluctuations in the terrestrial magnetosheath measured by the four Magnetospheric Multiscale (MMS) spacecraft on a spatial scale of about 20 km.The dispersion relation diagram and the wave vector distribution are determined for the first time in the ion-kinetic range. Moreover, the dispersion relation diagram is determined in a proxy plasma restframe by regarding the low-frequency dispersion relation as a Doppler relation and compensating for the apparent phase velocity. Fluctuations are highly compressible, and the wave vectors have an angle of about 60 from the mean magnetic field. We interpret that the measured fluctuations represent akinetic-drift mirror mode in the magnetosheath which is dispersive and in a turbulent state accompanied by a sideband formation.

Magnetometer↗

TEM Characterization of Solar Wind Effects on Genesis Mission Silicon Collectors

The Genesis Discovery Mission passively allowed solar wind (SW) to implant into substrates during exposure times up to ~853 days from 2001 to 2004. The spacecraft then returned the SW to Earth for analysis. Substrates included semiconductor wafers (silicon, sapphire, and germanium), as well as a number of thin films supported by either silicon or sapphire wafers. During flight, subsets of the SW collectors were exposed to one of 4 SW regimes: bulk solar wind, coronal hole solar wind (CH, high speed), interstream solar wind (IS, low speed) or coronal mass ejections (CMEs). Each SW regime had a different composition and range of ion speeds and, during their collection, uniquely changed their host SW collector. This study focuses on bulk vs IS SW effects on CZ silicon.

Allums, K. K.↗

NASA GeneLab Platform Utilized for Biological Response to Space Radiation in Animal Models

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

The Rapid Variability of Wave Electric Fields Within and Near Quasiperpendicular Interplanetary Shock Ramps: STEREO Observations

We present STEREO observations within 1500 proton gyroradii of 12 quasiperpendicular interplanetary shocks, with long-duration burst mode electric field acquisition by S/WAVES enabling observation of the evolution of waves throughout the entire ramp of interplanetary shocks. The shocks are low Mach number (Mf ~1-5), with beta ( ) ~0.2-1.8. High variability in frequency, amplitude, and wave mode is observed upstream, downstream, and in shock ramps. Observations in every region include ion acoustic-like waves, electron cyclotron drift instability driven waves, electrostatic solitary waves, and high frequency whistler mode waves. We also show for the fi rst time the existence of electrostatic waves with frequencies in the ion acoustic range which are frequency dispersed in time and the first observations of electron cyclotron drift instability (ECDI) driven waves at interplanetary shocks. The waves are bursty, large amplitude (~5 to > 200 mV/m), and seen in all three regions. All wave modes are more commonly observed downstream than upstream.

Z. A. Cohen↗

Edge ICRF simulations in 3D geometry: From MHD equilibrium to coupling determination

We present in this work a consistent numerical scheme that allows the computation of 3D magnetic fields a nd 3D density profiles and their usage in ion cyclotron range of frequencies (ICRF) coupling simulations. We first utilize the PARVMEC code to compute the 3D free-boundary plasma equilibrium in the ideal magnetohydrodynamic (MHD) approximation. Since the PARVMEC solution is only defined within the last closed flux surface (LCFS), the magnetic field domain is extended to the scrape-off layer (SOL) via the BMW code, which computes a divergence-free magnetic field solution arising from the external conductors’ vacuum field a nd t he PARVMEC flux surface currents. This magnetic reconstruction is then used in the EMC3-EIRENE transport code in order to compute 3D density profiles. In the last step, the RAPLICASOL code is utilized to compute the ICRF antenna S-matrices resulting from the 3D density profiles. We exemplify this scheme for the ASDEX Upgrade tokamak. A new implementation of a curved model for the ASDEX Upgrade ICRF 2-strap antenna in RAPLICASOL allows simulations in realistic geometry, without any coordinate transformations.

Lopez, Graham↗

Progress Testing TRANSP-TORIC Simulations of ICRH in JE

Introduction - Ion Cyclotron Range of Frequency (ICRF) waves are candidates for heating (ICRH), current drive, and possible flow drive in ITER and future tokamaks. There are considerable challenges developing the technology of ICRF systems and the tools for assessing effects on plasma performance. These tools are important both for guiding present experiments and for indicating efforts for future research. This paper addresses some of the tools for simulating ICRH. The TORIC ICRF full-wave code [1] solves the kinetic wave equation in 2D axisymmetric equilibria. TORIC solves Maxwell's Equations for a fixed wave frequency with a linear plasma response in a mixed spectral-finite element basis. The antenna is modelled as a sheet current. A kinetic model for the plasma dielectric response is derived using an Eikonal ansatz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cole-cole analysis and electrical conduction mechanism of N{sup +} implanted polycarbonate

In this paper, we present the analysis of the dielectric (dielectric constant, dielectric loss, a.c. conductivity) and electrical properties (I–V characteristics) of pristine and nitrogen ion implanted polycarbonate. The samples of polycarbonate were implanted with 100 keV N{sup +} ions with fluence ranging from 1 × 10{sup 15} to 1 × 10{sup 17} ions cm{sup −2}. The dielectric measurements of these samples were performed in the frequency range of 100 kHz to 100 MHz. It has been observed that dielectric constant decreases whereas dielectric loss and a.c. conductivity increases with increasing ion fluence. An analysis of real and imaginary parts of dielectric permittivity has been elucidated using Cole-Cole plot of the complex permittivity. With the help of Cole-Cole plot, we determined the values of static dielectric constant (ε{sub s}), optical dielectric constant (ε{sub ∞}), spreading factor (α), average relaxation time (τ{sub 0}), and molecular relaxation time (τ). The I–V characteristics were studied using Keithley (6517) electrometer. The electrical conduction behaviour of pristine and implanted polycarbonate specimens has been explained using various models of conduction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of frequency tuning and double-frequency heating on ions extracted from an electron cyclotron resonance ion source

The electromagnetic field within the plasma chamber of an electron cyclotron resonance ion source (ECRIS) and the properties of the plasma waves affect the plasma properties and ion beam production. We have experimentally investigated the ''frequency tuning effect'' and ''double frequency heating'' on the CAPRICE ECRIS device. A traveling wave tube amplifier, two microwave sweep generators, and a dedicated experimental set-up were used to carry out experiments in the 12.5-16.5 GHz frequency range. During the frequency sweeps the evolution of the intensity and shape of the extracted argon beam were measured together with the microwave reflection coefficient. A range of different ion source parameter settings was used. Here we describe these experiments and the resultant improved understanding of these operational modes of the ECR ion source.

43 PARTICLE ACCELERATORS↗

SU-E-T-539: Maximum Energy of Helium and Carbon Ions Clinically Needed for Spine, Lung, Prostate and Pancreas Cancer

Purpose: Maximum available kinetic energy of accelerated heavy ions is a critical parameter to consider during the establishment of a heavy ion therapy center. It dictates the maximum range in tissue and determines the size and cost of ion gantry. We have started planning our heavy ion therapy center and we report on the needed ion range. Methods: We analyzed 50 of random SBRT-spine, SBRT- lung, prostate and pancreatic cancer patients from our photon clinic. In the isocentric axial CT cut we recorded the maximum water equivalent depth (WED4Field) of PTV’s most distal edge in four cardinal directions and also in a beam direction that required the largest penetration, WEDGantry. These depths were then used to calculate the percentage of our patients we would be able to treat as a function of available maximum carbon and helium beam energy. Based on the Anterior-Posterior WED for lung patients and the maximum available ion energy we estimated the largest possible non-coplanar beam entry angle φ (deviation from vertical) in the isocentric vertical sagittal plane. Results: We found that if 430MeV/u C-12, equivalently 220MeV/u He-4, beams are available, more than 96% (98%) of all patients can be treated without any gantry restrictions (in cardinals angles only) respectively. If the energy is reduced to 400MeV/u C-12, equivalently 205MeV/u He-4, the above fractions reduce to 80% (87%) for prostate and 88% (97%) for other sites. This 7% energy decrease translates to almost 5% gantry size and cost decrease for both ions. These energy limits in combination with the WED in the AP direction for lung patients resulted in average non-coplanar angles of φ430MeV/u = 68°±8° and φ400MeV/u = 65°±10° if nozzle clearance permits them. Conclusion: We found that the two worldwide most common maximum carbon beam energies will treat above 80% of all our patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dissociative double-photoionization of butadiene in the 25-45 eV energy range using 3-D multi-coincidence ion momentum imaging spectrometry

Dissociative double-photoionization of butadiene in the 25-45 eV energy range has been studied with tunable synchrotron radiation using full three-dimensional ion momentum imaging. Using ab initio calculations, the electronic states of the molecular dication below 33 eV are identified. The results of the measurement and calculation show that double ionization from π orbitals selectively triggers twisting about the terminal or central C–C bonds. We show that this conformational rearrangement depends upon the dication electronic state, which effectively acts as a gateway for the dissociation reaction pathway. For photon energies above 33 eV, three-body dissociation channels where neutral H-atom evaporation precedes C–C charge-separation in the dication species appear in the correlation map. The fragment angular distributions support a model where the dication species is initially aligned with the molecular backbone parallel to the polarization vector of the light, indicating a high probability for double-ionization to the “gateway states” for molecules with this orientation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parametric Decay of Pump Waves into two Linear Modes in SINP MaPLE Device

Parametric decay of incident waves of ion cyclotron frequency range into linear modes is observed in experiment performed in the SINP MaPLE device where nitrogen plasma produced by ECR discharge. Along with a mode in drift wave frequency range, sideband of the incident waves are observed when amplitude of the exciter signal goes above a threshold value. Sideband of the second harmonic is also seen. Preliminary studies point towards excitation of ion Bernstein wave. Details of the experimental results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pre-treating water with non-thermal plasma

The present invention consists of a method of pre-treatment of adulterated water for distillation, including adulterated water produced during hydraulic fracturing ("fracking") of shale rock during natural gas drilling. In particular, the invention is directed to a method of treating adulterated water, said adulterated water having an initial level of bicarbonate ion in a range of about 250 ppm to about 5000 ppm and an initial level of calcium ion in a range of about 500 ppm to about 50,000 ppm, said method comprising contacting the adulterated water with a non-thermal arc discharge plasma to produce plasma treated water having a level of bicarbonate ion of less than about 100 ppm. Optionally, the plasma treated water may be further distilled.

03 NATURAL GAS↗