Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

U.S. Coast Guard Boat Recovery Simulation at the NASA Ames Vertical Motion Simulator

The U.S. Coast Guard routinely uses the Over-The-Horizon (OTH-IV), a cutter deployed, rigid-hulled inflatable boat for rescue and law enforcement operations. The term "cutter" refers to a Coast Guard vessel 65 feet in length or greater with accommodations for crew to live aboard and the ability to deploy smaller boats including the OTH-IV. A deployment method employed by some cutter class vessels is a davit crane system and specialized hook mechanism to connect the smaller boat. The launch and recovery operation requires several crewmembers, where one is tasked with releasing and connecting the hook to the small boat. Manipulating the hook can pose a risk to the crewmember depending on sea conditions combined with fatigue level or task expertise. Equipment and crewmembers are tested extensively due to the inherent risk of the task, but the sea conditions cannot be controlled. To address the sea condition variable, the U.S. Coast Guard and NASA leveraged the Vertical Motion Simulator (VMS) as a platform to test new equipment or train crewmembers in varying sea conditions. With 6 degrees of freedom and a vertical displacement of +/- 22ft, the VMS is capable of simulating conditions up to sea-state 5. The proof of concept experiment took place in September 2018 and demonstrated that the VMS can accurately simulate varying sea-states, collect performance data, and design a reliable and safe system for participants. The U.S. Coast Guard provided boat displacement data from the Large Amplitude Motion Program (LAMP). The program generates multi-directional waves with a cosine squared spreading function which produced a time history response of displacement data (surge, sway, heave, roll, pitch, yaw) of the OTH-IV's center of gravity (C.G). The displacement data was differentiated into acceleration evaluated at the crewmember's position at the front (bow) of the boat. Those accelerations were transformed to the VMS coordinate system and used as command inputs to the motion system's washout filters. The VMS uses Interchangeable Cabs (ICab) to perform flight simulations on a variety of aircraft or spacecraft configurations. An ICab typically contains seats, restraints, pilot controls, instrument panel, and out-the-window projectors all enclosed in a familiar cockpit configuration. To replicate the launch and recovery of a small boat, all the conventional features of a flight simulator and canopy were removed to be replaced with a to-scale OTH-IV bow mockup. The bow section was constructed from aluminum, and a connection point known as the davit ring. Additionally, a hook replica was suspended by a cable from the ceiling as if it were hanging from a davit crane aboard a cutter vessel. The last step was providing an auxiliary control to close the distance between suspended hook and the davit ring on the bow mockup. Without control the boat would simulate the wave motion, but with no guarantee that the crewmember will be in reach of the hook. Since the wave motion was repeatable, an additional acceleration command sent to the washout filters to move the simulator in the surge, sway, and heave directions, independently. The commands were rate limited such that the additional movement was not detectable with respect to the wave motion. The results showed that for each wave profile, a unique set of acceleration commands provided opportunities for crewmembers to gain control of the hook and connect it to the davit ring.

Riccobono, Nicholas S.↗

SIM testbed 3 real-time control software

SIM System Testbed 3 (STB3) features three optical interferometers sharing a common baseline, as a dynamic representation of the SIM instrument. An artificial star feeding the interferometers is installed on a separate optics bench. All three interferometers use photons captured by avalanche photo diodes (APDs) to measure the position and quality of fringes, and additional pointing precision is achieved by fast steering mirrors (FSMs) that keep the star images centered on the beam combining optics using a CCD camera. Each interferometer uses internal metrology to measure changes in its optical pathlength. External metrology beams measure changes in the baseline vector. This system acquires and tracks white light fringes with one interferometer, while the other two acquire and track laser light fringes representing the bright guide stars that will be used by SIM. The white light source represents a dim star that cannot supply enough photons for the Science interferometer to lock onto fringes in closed-loop mode; instead it operates open-loop, using pathlength corrections fed to it from the two guide interferometers and the external metrology subsystem to reject disturbances and maintain the fringes. This tracking mode is known as Pathlength Feed Forward (PFF). The precise real-time behavior required to achieve this result is implemented by a complex set of interacting software control loops. This paper describes how these loops take advantage of the benefits of the RTC Core architecture, and how they work together to accomplish STB3's objectives.

interferometry↗

Compact, single mode, frequency stabilized laser spectroscopy sources for isotope analysis

We will discuss here ultra-stable narrow line-width Hybrid External Cavity Lasers (HECL) of visible spectrum. The customer requires ~ 2 MHz linewidth / stability (2.7 fm). It is our goal to design the most stable possible ECL, and then enhance its long-term stability by disciplining it to an atomic wavelength reference. Protection against long-term drift can be provided by calibrating HECL wavelength to a hollow-cathode lamp (HCL) standard using the optogalvanic effect to adjust the HECL set-point. Here we report the short-term stability of the HECL alone, i.e., without the discipline of an atomic wavelength reference. For this purpose, we have studied HECLs operating at 405 nm and at 638 nm. We will interpret their performance in terms of the customer’s need for 600 – 700 nm narrow-linewidth spectroscopy. We selected to perform the portion of the work at 405 nm since the sensitivity to cavity stability is ~2x compared with operating in the 600 – 700 nm wavelength range. Further, we will show excellent wavelength stability over time at 638 nm. The two main ECL components are the semiconductor laser chip, including a high reflectivity (HR) mirror, and a volume Bragg grating (VBG) that provides output coupling. Between them is collimating optics. The theoretical analysis and experimental data suggest that control of ECL wavelength in the femtometer wavelength range can be achieved over short-term time scales by carefully controlling both the temperature and very high current stability. From the results presented here temperature control of the laser to 0.001° C along with current stability of 0.001 mA will be needed in a sensor instrument. Finally, we show a path to achieve 2 MHz short-term stability at 600 to 700 nm.

07 ISOTOPE AND RADIATION SOURCES↗

Reduction in 317-780 nm Radiance Reflected from the Sunlit Earth During the Eclipse of 21 August 2017

Ten wavelength channels of calibrated radiance image data from the sunlit Earth are obtained every 65 min during Northern Hemisphere summer from the EPIC (Earth Polychromatic Imaging Camera) instrument on the DSCOVR (Deep Space Climate Observatory) satellite located near the Earth-Sun Lagrange 1 point (L1), about 1.5 million km from the Earth. The L1 location permitted seven observations of the Moon's shadow on the Earth for about 3 h during the 21 August 2017 eclipse. Two of the observations were timed to coincide with totality over Casper, Wyoming, and Columbia, Missouri. Since the solar irradiances within five channels (λi = 388, 443, 551, 680, and 780 nm) are not strongly absorbed in the atmosphere, they can be used for characterizing the eclipse reduction in reflected radiances for the Earth's sunlit face containing the eclipse shadow. Five channels (λi = 317:5, 325, 340, 688, and 764 nm) that are partially absorbed in the atmosphere give consistent reductions compared to the non-absorbed channels. This indicates that cloud reflectivities dominate the 317.5-780 nm radiances reflected back to space from the sunlit Earth's disk with a significant contribution from Rayleigh scattering for the shorter wavelengths. An estimated reduction of 10% was obtained for spectrally integrated radiance (387 to 781 nm) reflected from the sunlit Earth towards L1 for two sets of observations on 21 August 2017, while the shadow was in the vicinity of Casper, Wyoming (42.8666° N, 106.3131° W; centered on 17:44:50 UTC), and Columbia, Missouri (38.9517° N, 92.3341° W; centered on 18:14:50 UTC). In contrast, when non-eclipse days (20 and 23 August) are compared for each wavelength channel, the change in reflected light is much smaller (less than 1% for 443 nm compared to 9% (Casper) and 8% (Columbia) during the eclipse). Also measured was the ratio R(sub EN)(λi) of reflected radiance on adjacent non-eclipse days divided by radiances centered in the eclipse totality region with the same geometry for all 10 wavelength channels. The measured R(sub EN)(443 nm) was smaller for Columbia (169) than for Casper (935), because Columbia had more cloud cover than Casper. R(sub EN)(λi) forms a useful test of a 3-D radiative transfer models for an eclipse in the presence of optically thin clouds. Specific values measured at Casper with thin clouds are R(sub EN)(340 nm)=475, R(sub EN)(388 nm)=3500, REN(443 nm)=935, REN(551 nm)=5455, REN(680 nm)=220, and R(sub EN)(780 nm)=395. Some of the variability is caused by changing cloud amounts within the moving region of totality during the 2.7 min needed to measure all 10 wavelength channels.

DSCOVR↗

Change Detection in Constellations of Buried Objects Extracted From Ground-Penetrating Radar Data

Detection of deliberately buried objects in ground-penetrating radar (GPR) data acquired along a path is a clutter-limited problem. Detection-false alarm rate performance can be improved by replacing the detection statistic with a change statistic that incorporates information from previous path traversals. A constellation matching approach is developed for buried-object change detection in GPR data. Network topologies of buried objects detected in GPR data from previous path traversals are maintained in a constellation database. Localized groups of buried objects newly detected on the latest path traversal are matched to the constellation. Buried objects from the latest path traversal whose locations or strengths cannot be reconciled with the constellation are identified as changes. The system has one component that generates constellation databases offline and another component suitable for change detection in real time. It can tolerate paths with significant translational misalignments. The system uses the following: 1) a customized translational relaxation algorithm for point pattern matching that incorporates detection strength and a probabilistic uncertainty model for buried-object location into the objective function and 2) a change statistic that accounts for the magnitude of change relative to predicted detection strength. A constellation database can typically be generated offline from a single path traversal roughly two orders of magnitude faster than the time typically required for a vehicle to travel the extent of the path. Database sizes are typically four to five orders of magnitude smaller than the data sets of GPR signal scans or focused 3-D GPR images that they were generated from. On bumpy dirt roads buried exclusively with nonmetallic objects at various depths, detection-false alarm rate performance is shown to be significantly better for our change statistics than for our detection statistics.

47 OTHER INSTRUMENTATION↗

An Applied Strategy for Using Empirical and Hybrid Models in Online Monitoring

The monitoring of plant equipment for failure prediction is one of the key contributors to operation and maintenance (O&M) costs for a nuclear power plant (NPP) because O&M monitoring depends on labor-intensive activities that are required to meet high equipment reliability standards. These activities rely primarily on humans for information gathering, condition diagnosis, and predictive analysis. Online monitoring aims to automate these activities by relying on sensors to replace human information gathering and machine learning to replace human analysis and decision making. To facilitate automated monitoring, a systematic strategy for anomaly detection is needed to optimally use the available sensor data, empirical models, and physics-supported models. This strategy is essential to provide credible reasoning on why and when an empirical (i.e., purely data-driven) versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. The extant methods usually adopt an ad hoc trial-and-error approach that, in addition to being time-consuming and costly, is also highly subjective; it is impacted by the background and the skill set of the personnel making the decisions. Thus, such an approach cannot guarantee an optimum outcome. This represents the motivation of the current research effort, which is focused on devising a scientifically supported strategy for the optimum selection of anomaly detection methods. This report presents a detailed assessment of the main anomaly detection techniques within the empirical or hybrid method streams. Empirical methods include pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The listed techniques within these two streams represent the vast majority of techniques performed for anomaly detection. Using the techniques as outcomes, a strategy was developed to enable a systematic decision-making process to lead to one of these techniques. The strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability and suitability for training and testing, cause-effect, entropy inference, and model fitting. Each of these decision points in the strategy is explained in detail in this report with examples, along with the scientific basis behind the decisions and outcomes in common and simplified terminology. The strategy is developed for use by any NPP staff with basic engineering or science knowledge. A user-friendly graphical state flow diagram was also developed as a visual presentation of the strategy. The strategy was tested and demonstrated through two pilot projects for the application of anomaly detection at an NPP. Each pilot had two use cases: an initial case in which certain decisions were made that resulted in one or more empirical techniques and a revised use case where one or more key decisions were modified resulting in using a set of hybrid methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of mathematical modeling in nuclear measurements projects

Mathematical modeling of nuclear measurement systems is not a new concept. The response of the measurement system is described using a pre-defined mathematical model that depends on a set of parameters. These parameters are determined using a limited set of experimental measurement points e.g. efficiency curve, dose rates... etc. The model that agrees with the few experimental points is called an experimentally validated model. Once these models have been validated, we use mathematical interpolation to find the parameters of interest. Sometimes, when measurements are not practical or are impossible extrapolation is implemented but with care. CANBERRA has been extensively using mathematical modeling for the design and calibration of large and sophisticated systems to create and optimize designs that would be prohibitively expensive with only experimental tools. The case studies that will be presented here are primarily performed with MCNP, CANBERRA's MERCURAD/PASCALYS and ISOCS (In Situ Object Counting Software). For benchmarking purposes, both Monte Carlo and ray-tracing based codes are inter-compared to show models consistency and add a degree of reliability to modeling results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method for High Resolution Surface Change Detection: Data Collection and Validation of Measurements from UAS at the Nevada National Security Site, Nevada, USA

The use of uncrewed aerial systems (UAS) increases the opportunities for detecting surface changes in remote areas and in challenging terrain. Detecting surface topographic changes offers an important constraint for understanding earthquake damage, groundwater depletion, effects of mining, and other events. For these purposes, changes on the order of 5–10 cm are readily detected, but sometimes it is necessary to detect smaller changes. An example is the surface changes that result from underground explosions, which can be as small as 3 cm. Previous studies that described change detection methodologies were generally not aimed at detecting sub-5-cm changes. Additionally, studies focused on high-fidelity accuracy were either computationally modeled or did not fully provide the necessary examples to highlight the usability of these workflows. Detecting changes at this threshold may be critical in certain applications, such as global security research and monitoring for high-consequence natural hazards, including landslides. Here we provide a detailed description of the methodology we used to detect 2–3 cm changes in an important applied research setting—surface changes related to underground explosions. This methodology improves the accuracy of change detection data collection and analysis through the optimization of pre-field planning, surveying, flight operations, and post-processing the collected data, all of which are critical to obtaining the highest output data resolution possible. We applied this methodology to a field study location, collecting 1.4 Tb of images over the course of 30 flights, and location data for 239 ground control points (GCPs). We independently verified changes with orthoimagery, and found that structure-from-motion, software-reported root mean square errors (RMSEs) for both control and check points underestimated the actual error. We found that 3 cm changes are detectable with this methodology, thereby improving our knowledge of a rock’s response to underground explosions.

47 OTHER INSTRUMENTATION↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is viewed as a viable hydrogen carrier due to favorable storage and transport characteristics. While it can be re-converted to hydrogen at point-of-use via thermal catalytic cracking, direct utilization in combustion systems can result in reduced costs and improved efficiency. A major barrier to this approach is the low flammability and potential for high nitrogen oxide emissions, driven by fuel-bound nitrogen and complex kinetic pathways. While a number of kinetic mechanisms currently exist for simulating ammonia combustion, a major need continues to be direct information about species profiles in easy-to-model systems capable of isolating chemical kinetics from multi-dimensional fluid dynamic effects. This paper reports on recent species measurements made in a flat flame burner using a combined tunable-diode-laser-absorption-spectroscopy (TDLAS) and chemiluminescence imaging approach. Three flame conditions were included representative of NH3/H2 blends, partially cracked NH3 (inc. N2), and 100% NH3 with enhanced air (30% oxygen). Two NIR distributed feedback (DFB) laser diodes were used to determine H2O concentration and temperature (via ratio thermometry) at various radial and axial positions, after which an inverse Abel transform was used to infer centerline values. Companion images were collected using a Princeton Instrument PI-MAX intensified camera equipped with a 105mm UV lens and multiple filter sets targeting OH*, NH*, and NH2* emission. Results were compared to companion Cantera burner-stabilized flame simulations using various kinetic mechanisms. A recent mechanism including excited species chemistry was also included, to investigate whether excited and ground state profiles exhibit significant differences.

ammonia combustion↗

Implementation and assessment of resolution-dependent elastic incoherent neutron scattering measurements at a backscattering spectrometer for probing relaxations in complex systems

We introduce the use of a higher-order reflection, Si(333), of the silicon analyzer crystals at a backscattering spectrometer to implement analysis of the relaxation dynamics in the samples. Here, this is achieved by monitoring the temperature dependence of the neutron scattering intensity perceived as elastic when measured using Si(111), Si(311), and Si(333) reflections. As a test case, we use a sample with well-characterized, but complex, relaxation pattern, where the non-Lorentzian relaxation function is known to exhibit a set of parameters specific to each temperature point and scattering momentum transfer (Q) value. Even for this very general relaxation pattern, characterized by no constrains on the relaxation function parameters, we successfully map the relaxation times measured using the present approach onto those previously obtained from the full analysis of the quasielastic neutron scattering signal. Analysis of the Q-specific activation energies becomes possible for the Q values accessible simultaneously through Si(111), Si(311), and Si(333) reflections (in the present case, 0.9 Å –1 < Q < 1.9 Å –1 ). While the dedicated neutron spectrometers for this type of analysis are yet to be constructed, we show that the present-day backscattering spectrometers can be employed, under certain conditions, to analyze temperature dependence of the relaxation time in the samples not amenable to traditional full analysis of the quasielastic neutron scattering signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed adaptive contact-mode atomic force microscopy imaging with near-minimum-force

In this paper, an adaptive contact-mode imaging approach is proposed to replace the traditional contact-mode imaging by addressing the major concerns in both the speed and the force exerted to the sample. The speed of the traditional contact-mode imaging is largely limited by the need to maintain precision tracking of the sample topography over the entire imaged sample surface, while large image distortion and excessive probe-sample interaction force occur during high-speed imaging. In this work, first, the image distortion caused by the topography tracking error is accounted for in the topography quantification. Second, the quantified sample topography is utilized in a gradient-based optimization method to adjust the cantilever deflection set-point for each scanline closely around the minimal level needed for maintaining stable probe-sample contact, and a data-driven iterative feedforward control that utilizes a prediction of the next-line topography is integrated to the topography feeedback loop to enhance the sample topography tracking. The proposed approach is demonstrated and evaluated through imaging a calibration sample of square pitches at both high speeds (e.g., scan rate of 75 Hz and 130 Hz) and large sizes (e.g., scan size of 30 μm and 80 μm). The experimental results show that compared to the traditional constant-force contact-mode imaging, the imaging speed can be increased by over 30 folds (with the scanning speed at 13 mm/s), and the probe-sample interaction force can be reduced by more than 15% while maintaining the same image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Airborne High Spectral Resolution Lidar Data to Evaluate Combined Active Plus Passive Retrievals of Aerosol Extinction Profiles

We derive aerosol extinction profiles from airborne and space-based lidar backscatter signals by constraining the retrieval with column aerosol optical thickness (AOT), with no need to rely on assumptions about aerosol type or lidar ratio. The backscatter data were acquired by the NASA Langley Research Center airborne High Spectral Resolution Lidar (HSRL) and by the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) instrument on the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) satellite. The HSRL also simultaneously measures aerosol extinction coefficients independently using the high spectral resolution lidar technique, thereby providing an ideal data set for evaluating the retrieval. We retrieve aerosol extinction profiles from both HSRL and CALIOP attenuated backscatter data constrained with HSRL, Moderate-Resolution Imaging Spectroradiometer (MODIS), and Multiangle Imaging Spectroradiometer column AOT. The resulting profiles are compared with the aerosol extinction measured by HSRL. Retrievals are limited to cases where the column aerosol thickness is greater than 0.2 over land and 0.15 over water. In the case of large AOT, the results using the Aqua MODIS constraint over water are poorer than Aqua MODIS over land or Terra MODIS. The poorer results relate to an apparent bias in Aqua MODIS AOT over water observed in August 2007. This apparent bias is still under investigation. Finally, aerosol extinction coefficients are derived from CALIPSO backscatter data using AOT from Aqua MODIS for 28 profiles over land and 9 over water. They agree with coincident measurements by the airborne HSRL to within +/-0.016/km +/- 20% for at least two-thirds of land points and within +/-0.028/km +/- 20% for at least two-thirds of ocean points.

Burton, S. P.↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

Kalman Filter for Calibrating a Telescope Focal Plane

The instrument-pointing frame (IPF) Kalman filter, and an algorithm that implements this filter, have been devised for calibrating the focal plane of a telescope. As used here, calibration signifies, more specifically, a combination of measurements and calculations directed toward ensuring accuracy in aiming the telescope and determining the locations of objects imaged in various arrays of photodetectors in instruments located on the focal plane. The IPF Kalman filter was originally intended for application to a spaceborne infrared astronomical telescope, but can also be applied to other spaceborne and ground-based telescopes. In the traditional approach to calibration of a telescope, (1) one team of experts concentrates on estimating parameters (e.g., pointing alignments and gyroscope drifts) that are classified as being of primarily an engineering nature, (2) another team of experts concentrates on estimating calibration parameters (e.g., plate scales and optical distortions) that are classified as being primarily of a scientific nature, and (3) the two teams repeatedly exchange data in an iterative process in which each team refines its estimates with the help of the data provided by the other team. This iterative process is inefficient and uneconomical because it is time-consuming and entails the maintenance of two survey teams and the development of computer programs specific to the requirements of each team. Moreover, theoretical analysis reveals that the engineering/ science iterative approach is not optimal in that it does not yield the best estimates of focal-plane parameters and, depending on the application, may not even enable convergence toward a set of estimates.

Kang, Bryan↗

Handheld Biosensor for COVID-19 Screening

We have made significant progress toward the development of an integrated nucleic acid amplification system for Autonomous Medical Devices Incorporated (AMDIs) Optikus handheld diagnostic device. In this effort, we developed a set of loop-mediated isothermal amplification (LAMP) primers for SARS-CoV-2 and then demonstrate amplification directly on a surface acoustic wave (SAW) sensor. We built associated hardware and developed a C-code to control the amplification process. The goal of this project was to develop a nucleic amplification assay that is compatible with SAW sensors to enable both nucleic and serological testing in a single handheld diagnostic device. Toward this goal, AMDI is collaborating Sandia National Laboratories to develop a rapid, portable diagnostic screening device that utilizes Sandias unique surface acoustic wave biosensor (SAW) for COVID-19 detection. Previously, the SANDIA- AMDI SAW sensor has successfully detected multiple high-profile bacteria viruses, including Ebola, HIV, Sin Nombre, and Anthrax. Over the last two years, AMDI and SANDIA have significantly improved the sensitivity and detection capability of the SAW biosensor and have also developed a modular hand-held, portable platform called the Optikus, which uses CD microfluidics and handheld instrumentation to automate all sample preparation, reagent introduction, sample delivery, and measurement for a number of different assay targets. We propose to use this platform for the development of a rapid (%3C30 minutes), point-of-care diagnostic test for detection of COVID-19 from nasal swab samples.

47 OTHER INSTRUMENTATION↗

Track-structure investigations: A supplement to microdosimetry

We conceived and developed an experimental apparatus able to measure the track structure (the spatial distribution of the points of ionizing collisions) of light ions, allowing the investigation of the track-core and penumbra regions separately. The device is based on single-electron counting technique, and simulates a target volume V of about 20 nm in diameter that can be moved with respect to a narrow primary particle beam, allowing the measurement of the ionization-cluster-size distribution as a function of the impact parameter. The experimental set up is mounted at the Tandem-Alpi LNL particle accelerator complex. The goal of the experiment is to investigate the formation of ionization-cluster-size distributions caused in a nanometre-sized volume by different light ions of medical interest (protons, lithium ions and carbon ions), when penetrating through or passing by the target volume at a specified distance.

43 PARTICLE ACCELERATORS↗

Modeling the National Ignition Facility neutron imaging system

Numerical modeling of the neutron imaging system for the National Ignition Facility (NIF), forward from calculated target neutron emission to a camera image, will guide both the reduction of data and the future development of the system. Located 28 m from target chamber center, the system can produce two images at different neutron energies by gating on neutron arrival time. The brighter image, using neutrons near 14 MeV, reflects the size and symmetry of the implosion ''hot spot.'' A second image in scattered neutrons, 10-12 MeV, reflects the size and symmetry of colder, denser fuel, but with only {approx}1%-7% of the neutrons. A misalignment of the pinhole assembly up to {+-}175 {mu}m is covered by a set of 37 subapertures with different pointings. The model includes the variability of the pinhole point spread function across the field of view. Omega experiments provided absolute calibration, scintillator spatial broadening, and the level of residual light in the down-scattered image from the primary neutrons. Application of the model to light decay measurements of EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A suggests that DPAC-30 and Liquid A would be preferred over the BCF99-55 scintillator chosen for the first NIF system, if they could be fabricated into detectors with sufficient resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Virtual Current Meters in Hydroelectric Turbine Intakes

Standards provide recommendations for the best practices in the installation of current meters for measuring fluid flow in closed conduits. These include PTC-18 and IEC-41 . Both of these standards refer to the requirements of the ISO Standard 3354 for cases where the velocity distribution is assumed to be regular and the flow steady. Due to the nature of the short converging intakes of Kaplan hydroturbines, these assumptions may be invalid if current meters are intended to be used to characterize turbine flows. In this study, we examine a combination of measurement guidelines from both ISO standards by means of virtual current meters (VCM) set up over a simulated hydroturbine flow field. To this purpose, a computational fluid dynamics (CFD) model was developed to model the velocity field of a short converging intake of the Ice Harbor Dam on the Snake River, in the State of Washington. The detailed geometry and resulting wake of the submersible traveling screen (STS) at the first gate slot was of particular interest in the development of the CFD model using a detached eddy simulation (DES) turbulence solution. An array of virtual point velocity measurements were extracted from the resulting velocity field to simulate VCM at two virtual measurement (VM) locations at different distances downstream of the STS. The discharge through each bay was calculated from the VM using the graphical integration solution to the velocity-area method. This method of representing practical velocimetry techniques in a numerical flow field has been successfully used in a range of marine and conventional hydropower applications. A sensitivity analysis was performed to observe the effect of the VCM array resolution on the discharge error. The downstream VM section required 11–33% less VCM in the array than the upstream VM location to achieve a given discharge error. In general, more instruments were required to quantify the discharge at high levels of accuracy when the STS was introduced because of the increased spatial variability of the flow velocity.

13 HYDRO ENERGY↗