Image retrieval and processing system version 2.0 development work

The Image Retrieval and Processing System (IRPS) is a software package developed at Washington University and used by the NASA Regional Planetary Image Facilities (RPIF's). The IRPS combines data base management and image processing components to allow the user to examine catalogs of image data, locate the data of interest, and perform radiometric and geometric calibration of the data in preparation for analysis. Version 1.0 of IRPS was completed in Aug. 1989 and was installed at several IRPS's. Other RPIF's use remote logins via NASA Science Internet to access IRPS at Washington University. Work was begun on designing and population a catalog of Magellan image products that will be part of IRPS Version 2.0, planned for release by the end of calendar year 1991. With this catalog, a user will be able to search by orbit and by location for Magellan Basic Image Data Records (BIDR's), Mosaicked Image Data Records (MIDR's), and Altimetry-Radiometry Composite Data Records (ARCDR's). The catalog will include the Magellan CD-ROM volume, director, and file name for each data product. The image processing component of IRPS is based on the Planetary Image Cartography Software (PICS) developed by the U.S. Geological Survey, Flagstaff, Arizona. To augment PICS capabilities, a set of image processing programs were developed that are compatible with PICS-format images. This software includes general-purpose functions that PICS does not have, analysis and utility programs for specific data sets, and programs from other sources that were modified to work with PICS images. Some of the software will be integrated into the Version 2.0 release of IRPS. A table is presented that lists the programs with a brief functional description of each.

Slavney, Susan H.↗

On the Use of Mahalanobis Distance in Particle Image Velocimetry Post-Processing

Particle Image Velocimetry (PIV) is a method of flow measurement that has become increasingly popular as an experimental tool. New technology has made high-speed and higher-dimension (stereoscopic, tomographic, etc) methods available to an ever-growing population of researchers. These advanced methods can provide significantly more data than traditional low-speed planar PIV, but these larger data sets also require more resources to process and store. A major time sink in the post-processing of large PIV data sets is the identification and rejection of “bad” or ”spurious” vectors that survive an initial processing step in commercial software, which attempts to identify spurious vectors on an image-by-image basis and not with respect to repeated trials. The Mahalanobis distance, an almost 100-year-old statistical function, was determined to be well suited for this task for its computational efficiency and higher-dimensional nature. This work includes a summary of the Mahalanobis distance and validation of its usefulness as a tool for outlier rejection in the post-processing of PIV data.

Experimental Methods↗

Photogrammetry Toolbox Reference Manual

Specialized photogrammetric and image processing MATLAB functions useful for wind tunnel and other ground-based testing of aerospace structures are described. These functions include single view and multi-view photogrammetric solutions, basic image processing to determine image coordinates, 2D and 3D coordinate transformations and least squares solutions, spatial and radiometric camera calibration, epipolar relations, and various supporting utility functions.

Liu, Tianshu↗

Super-resolution for scanning light stimulation systems

Super-resolution (SR) is a technique used in digital image processing to overcome the resolution limitation of imaging systems. In this process, a single high resolution image is reconstructed from multiple low resolution images. SR is commonly used for CCD and CMOS (Complementary Metal-Oxide-Semiconductor) sensor images, as well as for medical applications, e.g., magnetic resonance imaging. Here, we demonstrate that super-resolution can be applied with scanning light stimulation (LS) systems, which are common to obtain space-resolved electro-optical parameters of a sample. For our purposes, the Projection Onto Convex Sets (POCS) was chosen and modified to suit the needs of LS systems. To demonstrate the SR adaption, an Optical Beam Induced Current (OBIC) LS system was used. The POCS algorithm was optimized by means of OBIC short circuit current measurements on a multicrystalline solar cell, resulting in a mean square error reduction of up to 61% and improved image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A programmable video image remapper

NASA's Johnson Space Center (JSC) has created the specifications for a new kind of image processing machine, a video-rate coordinate remapper. Previous image-processing machines for machine vision typically have done point operations without changing the geometry of the image. The JSC Programmable Remapper offers complete flexibility in changing the coordinates of an input image at video rates. Presented here are the main capabilities and some of the applications of such a device.

Fisher, Timothy E.↗

Optical processing for distributed sensors in control of flexible spacecraft

A recent potential of distributed image processing is discussed. Applications in the control of flexible spacecraft are emphasized. Devices are currently being developed at NASA and in universities and industries that allow the real-time processing of holographic images. Within 5 years, it is expected that, in real-time, one may add or subtract holographic images at optical accuracy. Images are stored and processed in crystal mediums. The accuracy of their storage and processing is dictated by the grating level of laser holograms. It is far greater than that achievable using current analog-to-digital, pixel oriented, image digitizing and computing techniques. Processors using image processing algebra can conceptually be designed to mechanize Fourier transforms, least square lattice filters, and other complex control system operations. Thus, actuator command inputs derived from complex control laws involving distributed holographic images can be generated by such an image processor. Plans are revealed for the development of a Conjugate Optics Processor for control of a flexible object.

Montgomery, Raymond C.↗

Methodology for the Elimination of Reflection and System Vibration Effects in Particle Image Velocimetry Data Processing

A methodology to eliminate model reflection and system vibration effects from post processed particle image velocimetry data is presented. Reflection and vibration lead to loss of data, and biased velocity calculations in PIV processing. A series of algorithms were developed to alleviate these problems. Reflections emanating from the model surface caused by the laser light sheet are removed from the PIV images by subtracting an image in which only the reflections are visible from all of the images within a data acquisition set. The result is a set of PIV images where only the seeded particles are apparent. Fiduciary marks painted on the surface of the test model were used as reference points in the images. By locating the centroids of these marks it was possible to shift all of the images to a common reference frame. This image alignment procedure as well as the subtraction of model reflection are performed in a first algorithm. Once the images have been shifted, they are compared with a background image that was recorded under no flow conditions. The second and third algorithms find the coordinates of fiduciary marks in the acquisition set images and the background image and calculate the displacement between these images. The final algorithm shifts all of the images so that fiduciary mark centroids lie in the same location as the background image centroids. This methodology effectively eliminated the effects of vibration so that unbiased data could be used for PIV processing. The PIV data used for this work was generated at the NASA Langley Research Center Quiet Flow Facility. The experiment entailed flow visualization near the flap side edge region of an airfoil model. Commercial PIV software was used for data acquisition and processing. In this paper, the experiment and the PIV acquisition of the data are described. The methodology used to develop the algorithms for reflection and system vibration removal is stated, and the implementation, testing and validation of these algorithms are presented.

Bremmer, David M.↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

METEOSAT studies of clouds and radiation budget

Radiation budget studies of the atmosphere/surface system from Meteosat, cloud parameter determination from space, and sea surface temperature measurements from TIROS N data are all described. This work was carried out on the interactive planetary image processing system (IPIPS), which allows interactive manipulationion of the image data in addition to the conventional computational tasks. The current hardware configuration of IPIPS is shown. The I(2)S is the principal interactive display allowing interaction via a trackball, four buttons under program control, or a touch tablet. Simple image processing operations such as contrast enhancing, pseudocoloring, histogram equalization, and multispectral combinations, can all be executed at the push of a button.

Saunders, R. W.↗

Investigation of Bipropellant Plume-Induced Contamination Effects on Coverglass Materials

Contamination and degradation of external spacecraft materials by unburned and partially combusted species from bipropellant thruster plumes has long been observed as a key component of the induced space environment. Space shuttle flight experiments and returned flight hardware from the International Space Station (ISS) have both experienced microscopic impact features induced by high-velocity thruster plume droplets. Analytical results have shown that droplet impingement angle relative to a receiving surface plays a key role in the surface damage. Although impacts with normal impingement angles contribute more severely to surface degradation than highly oblique angles, surface effects at higher impingement angles should not be dismissed. Thruster plume-induced materials degradation is a complex phenomenon that depends on a variety of parameters, including but not limited to material type, system temperature and pressure, plume composition, and thruster firing specifications such as number of pulses, pulse duration, and sample distance from the thruster. For space applications, attaining the vacuum pressure and temperature conditions necessary for flight-like plume expansion and exposure conditions is not a trivial task. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt, DLR) is a facility uniquely capable of simulating such conditions. Test coupons were exposed to bipropellant thruster firings under high vacuum at the DLR facility. Percent area coverage (PAC) and droplet size distributions were evaluated for the uncoated and coated solar array coverglass materials over a range of impingement angles (0̊ to 75̊). A post-test imaging workflow was developed that aimed to quantify changes in sample surface morphology obtained from scanning electron microscopy (SEM) images using the Image Processing and Analysis in Java (ImageJ) tool; an opensource image processing software. The goal was to create a framework through which to evaluate the effect of bipropellant-induced PAC and droplet size distribution on solar array coverglass optical transmission losses. Understanding this relationship is important because optical transmission losses are known to lead to current reduction in solar power generation systems. In addition to the development of surface characterization workflows, valuable lessons learned as they pertain to future investigations and experiments will be discussed. The authors hope that sharing these lessons will facilitate more utilization of DLR’s unique capabilities as well as open the conversation for how best to address experimental characterization of flight-like plume expansion and its impacts on materials surface degradation effects.

Gateway↗

Automated Recognition of 3D Features in GPIR Images

A method of automated recognition of three-dimensional (3D) features in images generated by ground-penetrating imaging radar (GPIR) is undergoing development. GPIR 3D images can be analyzed to detect and identify such subsurface features as pipes and other utility conduits. Until now, much of the analysis of GPIR images has been performed manually by expert operators who must visually identify and track each feature. The present method is intended to satisfy a need for more efficient and accurate analysis by means of algorithms that can automatically identify and track subsurface features, with minimal supervision by human operators. In this method, data from multiple sources (for example, data on different features extracted by different algorithms) are fused together for identifying subsurface objects. The algorithms of this method can be classified in several different ways. In one classification, the algorithms fall into three classes: (1) image-processing algorithms, (2) feature- extraction algorithms, and (3) a multiaxis data-fusion/pattern-recognition algorithm that includes a combination of machine-learning, pattern-recognition, and object-linking algorithms. The image-processing class includes preprocessing algorithms for reducing noise and enhancing target features for pattern recognition. The feature-extraction algorithms operate on preprocessed data to extract such specific features in images as two-dimensional (2D) slices of a pipe. Then the multiaxis data-fusion/ pattern-recognition algorithm identifies, classifies, and reconstructs 3D objects from the extracted features. In this process, multiple 2D features extracted by use of different algorithms and representing views along different directions are used to identify and reconstruct 3D objects. In object linking, which is an essential part of this process, features identified in successive 2D slices and located within a threshold radius of identical features in adjacent slices are linked in a directed-graph data structure. Relative to past approaches, this multiaxis approach offers the advantages of more reliable detections, better discrimination of objects, and provision of redundant information, which can be helpful in filling gaps in feature recognition by one of the component algorithms. The image-processing class also includes postprocessing algorithms that enhance identified features to prepare them for further scrutiny by human analysts (see figure). Enhancement of images as a postprocessing step is a significant departure from traditional practice, in which enhancement of images is a preprocessing step.

Park, Han↗

Developing tools for digital radar image data evaluation

The refinement of radar image analysis methods has led to a need for a systems approach to radar image processing software. Developments stimulated through satellite radar are combined with standard image processing techniques to create a user environment to manipulate and analyze airborne and satellite radar images. One aim is to create radar products for the user from the original data to enhance the ease of understanding the contents. The results are called secondary image products and derive from the original digital images. Another aim is to support interactive SAR image analysis. Software methods permit use of a digital height model to create ortho images, synthetic images, stereo-ortho images, radar maps or color combinations of different component products. Efforts are ongoing to integrate individual tools into a combined hardware/software environment for interactive radar image analysis.

Domik, G.↗

Focus enhancement in long schlieren imaging systems using corrector lenses

Long schlieren imaging systems, where the parallel light test section is longer than the focal length of the focusing schlieren optics, have a limited region in the test section in which any occluding object, such as a wind tunnel model, is in focus in the schlieren image. Corrector lenses are introduced here to alter the location in the test section where image focus is achieved. Corrector lenses with focal lengths varying from −1000 to −100mm were studied. Lens-type inline and z -type mirror schlieren systems were experimentally tested with multiple collecting optic focal lengths to characterize the changes in focal position. An automated image processing method was used to determine the plane of best focus from image sequences. The introduction of the corrector lens was observed to move the location of best focus within the schlieren system test section while also causing a decrease in the focal sharpness of the images and altering the magnification. The thin lens equation was found to provide a good estimate of the focal location change in the schlieren imaging systems with the addition of the corrector lens.

Torres, Sivana M.↗

Application of advanced signal processing techniques to the rectification and registration of spaceborne imagery

The development of an ERTS/MSS image processing system responsive to the needs of the user community is discussed. An overview of the TRW ERTS/MSS processor is presented, followed by a more detailed discussion of image processing functions satisfied by the system. The particular functions chosen for discussion are evolved from advanced signal processing techniques rooted in the areas of communication and control. These examples show how classical aerospace technology can be transferred to solve the more contemporary problems confronting the users of spaceborne imagery.

Caron, R. H.↗

Opportunistic bone density screening for the abdominal radiologist using colored CT images: a pilot retrospective study

Purpose: The purpose of the study was to develop an accurate and reproducible method for detecting low spinal bone density on abdominal CT images. Methods: For this IRB-approved HIPAA-compliant single-center retrospective study, nonenhanced CT images of the lower abdomen were obtained in 631 African-American participants. Mean attenuation of L3/L4 was associated with quantitative CT bone density (QCT) in a randomly selected training cohort (N = 511), and receiver operating characteristics analysis was used to identify the optimal mean attenuation threshold for differentiating normal from low bone density. Custom image processing software was used to generate grayscale and colored CT images of the midline spine, with green for normal and red for low bone density. Five radiologists independently assessed bone density at L3/L4 in a validation cohort (N = 120) using various methods: QCT, visual assessment of sagittal grayscale images (Grayscale), quantitative measurement of mean attenuation on a midline sagittal image (Attenuation), and visual assessment of a midline sagittal colored image (Color). Accuracy was calculated using the average QCT bone density as a reference standard. Inter-observer agreement was assessed using intraclass correlation coefficient (ICC). Results: The optimal mean attenuation threshold for differentiating normal from low bone density at L3/L4 was 145 Hounsfield Units. The average accuracy of Grayscale, Attenuation, and Color methods was 58, 87, and 91% (p < 0.001), respectively. Inter-observer agreement was poor for Grayscale (ICC: 0.20; 95% CI 0.12, 0.28) and excellent for both Attenuation (ICC: 0.85; 95% CI 0.73, 0.91) and Color methods (ICC: 0.87; 95% CI 0.83, 0.90). Conclusion: Detection of low spinal bone density using colored abdominal CT images was highly accurate and reproducible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perona Malik anisotropic diffusion model using Peaceman Rachford scheme on digital radiographic image

In image processing, it is important to remove noise without affecting the image structure as well as preserving all the edges. Perona Malik Anisotropic Diffusion (PMAD) is a PDE-based model which is suitable for image denoising and edge detection problems. In this paper, the Peaceman Rachford scheme is applied on PMAD to remove unwanted noise as the scheme is efficient and unconditionally stable. The capability of the scheme to remove noise is evaluated on several digital radiography weld defect images computed using MATLAB R2009a. Experimental results obtained show that the Peaceman Rachford scheme improves the image quality substantially well based on the Peak Signal to Noise Ratio (PSNR). The Peaceman Rachford scheme used in solving the PMAD model successfully removes unwanted noise in digital radiographic image.