Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Design and Engineering of LUPIN: A Test-Bed Radiofrequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D Neutral Beam Injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10 s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa·L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Liquid metal alloy ion sources—An alternative for focussed ion beam technology

Today, Focused Ion Beam (FIB) processing is nearly exclusively based on gallium Liquid Metal Ion Sources (LMIS). But, many applications in the μm- or nm range could benefit from ion species other than gallium: local ion implantation, ion beam mixing, ion beam synthesis, or Focused Ion Beam Lithography (IBL). Therefore, Liquid Metal Alloy Ion Sources (LMAIS) represent a promising alternative to expand the remarkable application fields for FIB. Especially, the IBL process shows potential advantages over, e.g., electron beam or other lithography techniques: direct, resistless, and three-dimensional patterning, enabling a simultaneous in-situ process control by cross-sectioning and inspection. Taking additionally into account that the used ion species influences significantly the physical and chemical nature of the resulting nanostructures—in particular, the electrical, optical, magnetic, and mechanic properties leading to a large potential application area which can be tuned by choosing a well suited LMAIS. Nearly half of the elements of the periodic table are recently available in the FIB technology as a result of continuous research in this area during the last forty years. Key features of a LMAIS are long life-time, high brightness, and stable ion current. Recent developments could make these sources feasible for nano patterning issues as an alternative technology more in research than in industry. The authors will review existing LMAIS, LMIS other than Ga, and binary and ternary alloys. These physical properties as well as the fabrication technology and prospective domains for modern FIB applications will similarly be reviewed. Other emerging ion sources will be also presented and their performances discussed.

36 MATERIALS SCIENCE↗

DUHOCAMIS: A dual hollow cathode ion source for metal ion beams

In this paper we describe a novel ion source named DUHOCAMIS for multiply charged metal ion beams. This ion source is derived from the hot cathode Penning ion gauge ion source (JINR, Dubna, 1957). A notable characteristic is the modified Penning geometry in the form of a hollow sputter electrode, coaxially positioned in a compact bottle-magnetic field along the central magnetic line of force. The interaction of the discharge geometry with the inhomogeneous but symmetrical magnetic field enables this device to be operated as hollow cathode discharge and Penning discharge as well. The main features of the ion source are the very high metal ion efficiency (up to 25%), good operational reproducibility, flexible and efficient operations for low charged as well as highly charged ions, compact setup, and easy maintenance. For light ions, e.g., up to titanium, well-collimated beams in the range of several tens of milliamperes of pulsed ion current (1 ms, 10/s) have been reliably performed in long time runs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-pulse arc-discharge plasma source with cold cathode for diagnostic neutral beam injector

Long-pulse cold cathode arc-discharge plasma generators have been successfully used as high-quality hydrogen ion sources for plasma diagnostic neutral beams. One of the main advantages of this type of plasma source is a high proton fraction (80%-90%). However, the lifetime of the plasma source is limited due to intensive electrode's erosion, especially at the cathode region. An optimized design of the cathode and the nearest electrodes is found which reduces the erosion and allows us to increase the pulse length. The plasma source produces the extracted ion current up to 3 A at a low angular divergence, and at the pulse duration up to 2 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solar wind double ions beams and the heliospheric current sheet

Double ion beams are often observed in the solar wind, but little work has been done in relating these beams to structures within the solar wind. Double ion beams are observed as beams of a given ion species and charge state occurring at two different energies. We use the three-dimensional ion plasma instrument on board the Ulysses spacecraft to look for evidence of such beams associated with the heliospheric current sheet. In a subset chosen independently of plasma parameters consisting of 8 of cover 47 crossings of the current sheet made during the inecliptic phase of the Ulysses mission we find that these double ion beams are always present on either side of the current sheet. The double beams are present in both the proton and helium species. The secondary beam typically has a higher helium abundance, which suggests that these beams are formed in the helium-rich corona rather than in interplanetary space. The double beams are not present in the interior of the current sheet. Neither collisions nor effects of plasma beta can account for the disappearance of the double beams inside the current sheet in all eight cases. We postulate that these beams are formed by reconnection occurring near the Sun in the boundary region between the open field lines of the coronal holes and the closed field line region of the heliospheric current sheet. Such a scenario would be consistent with previous X ray measurements which suggect that reconnection is occurring in this region.

Hammond, C. M.↗

From Microparticles to Nanowires and Back: Radical Transformations in Plated Li Metal Morphology Revealed via in Situ Scanning Electron Microscopy

We report that Li metal is the preferred anode material for all-solid-state Li batteries. However, a stable plating and stripping of Li metal at the anode–solid electrolyte interface remains a significant challenge particularly at practically feasible current densities. This problem usually relates to high and/or inhomogeneous Li-electrode–electrolyte interfacial impedance and formation and growth of high-aspect-ratio dendritic Li deposits at the electrode–electrolyte interface, which eventually shunt the battery. To better understand details of Li metal plating, we use operando electron microscopy and Auger spectroscopy to probe nucleation, growth, and stripping of Li metal during cycling of a model solid-state Li battery as a function of current density and oxygen pressure. We find a linear correlation between the nucleation density of Li clusters and the charging rate in an ultrahigh vacuum, which agrees with a classical nucleation and growth model. Moreover, the trace amount of oxidizing gas (≈10 –6 Pa of O 2 ) promotes the Li growth in a form of nanowires due to a fine balance between the ion current density and a growth rate of a thin lithium-oxide shell on the surface of the metallic Li. Interestingly, increasing the partial pressure of O 2 to 10 –5 Pa resumes Li plating in a form of 3D particles. In conclusion, our results demonstrate the importance of trace amounts of preexisting or ambient oxidizing species on lithiation processes in solid-state batteries.

25 ENERGY STORAGE↗

First storage of ion beams in the Double Electrostatic Ion-Ring Experiment: DESIREE

We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C{sub n}{sup -}, n= 1, 2, 3, 4) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C{sub 2}{sup -} molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s {+-} 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10{sup -14} mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity.

43 PARTICLE ACCELERATORS↗

A comparison of the Gurevich et al. and the Liu-Jew wake models for the ion flux around a satellite

Observations of ion currents obtained by a retarding potential analyzer on board the Explorer 31 satellite were used to compare the Liu-Jew (Liu, 1969) and Gurevich et al. (1970) wake models with experiment. The quantitative degree of agreement is shown and discussed. The Gurevich et al. 'neutral approximation' was tested via the observations and was found to be fairly good for regions where the hydrogen ions constitute more than 20 per cent of the plasma and the Mach number is low. For the case of high Mach number, the Liu-Jew computations are in better agreement with the observations over the angle of attack range which could be studied, namely, 100-130 degrees.

Samir, U.↗

Modeling fast ion losses due to tearing and internal kink perturbations in MAST-U

Fast ion (FI) loss properties in the presence of tearing mode and internal kink perturbations are numerically investigated for discharges in the MAST-U spherical tokamak, utilizing the MARS-F magnetohydrodynamic stability code and the REORBIT test particle guiding-center orbit-following module. Here, tracing about 100 000 particle markers sampled from the equilibrium distribution of the neutral-beam injection induced FIs, it is found that about 10% out of the total strike the limiting surface (including the divertor surface) in MAST-U discharge 46943, assuming a maximum perturbation of 100 G inside the plasma (corresponding to ~6 G at the Mirnov probe location at the outboard mid-plane). Detailed particle tracing, assuming a uniform initial distribution in the 2D phase space (at given radial locations), reveals that initially counter-current FIs launched near the plasma edge are subject to significant prompt losses, while almost all initially co-current ions remain well confined at the assumed perturbation level. Most lost FIs strike the lower-half of the limiting surface. Finite gyro-radius effects prevent lost ions from striking the top-outer corner of the super-X divertor chamber. A scan of the perturbation level (based on discharge 45163) reveals, not surprisingly, an approximately linear scaling of the particle loss fraction (for counter-current FIs) with respect to the perturbation amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of Gas-Phase Ion Mobility Coefficients Using Voltage Sweep Multiplexing

In a standard single averaged, drift tube ion mobility spectrometry (IMS) experiment, typically less than 1% of the ions are utilized, with the rest of the ions neutralizing on a closed ion gate or ion optic element. Though some efforts at lower pressures (e.g., 4 Torr) have been made to address this issue by concentrating ions prior to release into a drift cell, the ion current reaching the detector during an IMS experiment is often diminished due to this lower duty cycle. Additionally, when considering the temporal nature of the drift tube IMS experiment and the trajectory of IMS towards higher resolution separations and lower duty cycles, increased detector sampling rates are another factor also which further necessitates new modes of conducting the IMS experiment. Placing this trend in context with ion mobility-mass spectrometry instruments (IM-MS), there are numerous types of mass spectrometers that are simply incompatible with the single averaged ion mobility spectrometry experiments due to timing incompatibilities (i.e., ion traps are an order of magnitude slower than the IMS experiment). However, by utilizing a dual gate ion mobility spectrometer for ion multiplexing, ion utilization efficiency can be significantly increased while creating a measurement signal that can be recorded at low sampling rates. In this work, we present the fundamental theory and first results from proof-of-concept measurements using a new type of ion multiplexing that relies on changing the electric field within the drift cell during the course of an experiment while simultaneously opening the ion gates at a constant frequency. For brevity, this mode is termed voltage sweep multiplexing (VSM). Key variables for this type of experiment are discussed and verified with measurements from traditional signal averaged experiments. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

Thermal ions at Saturn - Plasma parameters and implications

Plasma data from the PLS experiment on Voyagers 1 and 2 are analyzed at the Saturn encounters. Measured ion currents are simulated using the full response function of the PLS instrument assuming plasma distributions are isotropic Maxwellians. The plasma velocity, densities, and temperatures which best simulate the observations are determined. Saturn's magnetosphere is found to subcorotate outside of L = 5.5 for Voyager 1 and L = 7 for Voyager 2. Large radial and vertical flows are observed, especially in the outer magnetosphere and on the nightside. Ion temperatures increase with L to a maximum at L = 10, outside of which they vary rapidly. A temperature anisotropy with T-perpendicular greater than T-parallel is necessary to account for the observed temperatures and densities. The ions present are H(+) and O(+); there is no evidence of heavier ions or higher charge states. Calculations of N(L-squared) show an O(+) peak at L = 10 for both encounters, indicating the major O(+) source is at L = 10.

Richardson, J. D.↗

Properties of a weakly ionized NO gas sensor based on multi-walled carbon nanotubes

Nitric oxide NO is one of the major targets for environmental monitoring, but the existing NO sensors are limited by their low sensitivity and narrow test range. Here, a NO gas sensor employing multiwalled carbon nanotubes (MWCNTs) was fabricated, and its properties in NO–N{sub 2} mixture were investigated from both emission and ionization. The current I{sub e} passing through the nanotubes cathode was found to decrease with increasing NO concentration and increase linearly in different slopes with the extracting voltage U{sub e}. It is shown that the Schottky barrier of the MWCNTs calculated by I{sub e} increased with NO concentration due to the adsorption of NO gas, which restrained the electron emission and consequently weakened the ionization. The positive ion currents I{sub c} passing through the collecting electrode at different voltages of U{sub e} were found to monotonically decrease with increasing NO concentration, which was induced by both of the reduced electron emission and the consumption of the two excited metastable states N{sub 2}(A{sup 3}∑{sub u}{sup +}) and N{sub 2}(a′{sup 1}∑{sub u}{sup −}) by NO. The sensor exhibited high sensitivity at the low temperature of 30 °C. The calculated conductivity was found to be able to take place of I{sub c} for NO detection in a wide voltage range of 80–150 V U{sub e}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A large-acceptance beam-deceleration module for retrofitting into ion-source beam lines

We describe a large-acceptance deceleration module capable of decelerating large-emittance full-intensity ion beams typical of ECR ion sources to very low energies with high efficiency. The deceleration module is designed to permit convenient retrofitting into an existing beam line to replace, e.g., the first Faraday cup after magnetic analysis of the beam extracted from the ion source. For starting energies of 10 keV, and incident ion currents as large as 300 {mu}A, deceleration efficiencies have been measured to be greater than 80% for final energies as low as 70 eV. The decelerated beam intensity can be monitored either by insertion of a beam catcher floating at the final deceleration voltage or from the current to the exit grid itself, with suitable correction applied for the grid transparency factor. The behavior of the deceleration optics was modeled using SIMION, incorporating the effects of intra-beam space charge repulsion. We describe a recent application of this deceleration module to study near-surface He bubble and blister formation of a W target heated to 1250 K and irradiated with a 98 eV He ion beam with a flux of {approx}10{sup 16} cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗

Environmentally-induced discharge transient coupling to spacecraft

The Hughes SCREENS (Space Craft Response to Environments of Space) technique was applied to generic spin and 3-axis stabilized spacecraft models. It involved the NASCAP modeling for surface charging and lumped element modeling for transients coupling into a spacecraft. A differential voltage between antenna and spun shelf of approx. 400 V and current of 12 A resulted from discharge at antenna for the spinner and approx. 3 kv and 0.3 A from a discharge at solar panels for the 3-axis stabilized Spacecraft. A typical interface circuit response was analyzed to show that the transients would couple into the Spacecraft System through ground points, which are most vulnerable. A compilation and review was performed on 15 years of available data from electron and ion current collection phenomena. Empirical models were developed to match data and compared with flight data of Pix-1 and Pix-2 mission. It was found that large space power systems would float negative and discharge if operated at or above 300 V. Several recommendations are given to improve the models and to apply them to large space systems.

Viswanathan, R.↗

Modeling Electric Field Influences on Plasmaspheric Refilling

We have a new model of ion transport that we have applied to the problem of plasmaspheric flux tube refilling after a geomagnetic disturbance. This model solves the Fokker-Planck kinetic equation by applying discrete difference numerical schemes to the various operators. Features of the model include a time-varying ionospheric source, self-consistent Coulomb collisions, field-aligned electric field, hot plasma interactions, and ion cyclotron wave heating. We see refilling rates similar to those of earlier observations and models, except when the electric field is included. In this case, the refilling rates can be quite different that previously predicted. Depending on the populations included and the values of relevant parameters, trap zone densities can increase or decrease. In particular, the inclusion of hot populations near the equatorial region (specifically warm pancake distributions and ring current ions) can dramatically alter the refilling rate. Results are compared with observations as well as previous hydrodynamic and kinetic particle model simulations.

Liemohn, M. W.↗

Simple filtered repetitively pulsed vacuum arc plasma source

A very simple design of cathodic filtered vacuum arc plasma source is proposed. The source without filter has only four components and none of them require precise machining. The source operates in a repetitively pulsed regime, and for laboratory experiments it can be used without water cooling. Despite the simple construction, the source provides high ion current at the filter outlet reaching 2.5% of 400 A arc current, revealing stable operation in a wide pressure range from high vacuum to oxygen pressure up to more than 10{sup -2} mbar. There is no need in complicated power supply system for this plasma source, only one power supply can be used to ignite the arc, to provide the current for the arc itself, to generate the magnetic field in the filter, and provide its positive electric biasing without any additional high power resistance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling for calculation of vanadium oxide film composition in reactive-sputtering process

A modified model describing the changing ratio of vanadium to oxide on the target and substrate as a function of oxygen flow is described. Actually, this ratio is extremely sensitive to the deposition conditions during the vanadium oxide (VO{sub x}) reactive magnetron-sputtering process. The method in this article is an extension of a previously presented Berg's model, where only a single stoichiometry compound layer was taken into consideration. This work deals with reactive magnetron sputtering of vanadium oxide films with different oxygen contents from vanadium metal target. The presence of vanadium mixed oxides at both target and substrate surface produced during reactive-sputtering process are included. It shows that the model can be used for the optimization of film composition with respect to oxygen flow in a stable hysteresis-free reactive-sputtering process. A systematic experimental study of deposition rate of VO{sub x} with respect to target ion current was also made. Compared to experimental results, it was verified that the theoretical calculation from modeling is in good agreement with the experimental counterpart.

36 MATERIALS SCIENCE↗