Investigation of the adsorption mechanism of a peptide in reversed phase liquid chromatography, from pH controlled and uncontrolled solutions

The single-component equilibrium adsorption of the tripeptide Leucyl-Leucyl-Leucine (LLL) on a high-efficiency Jupiter Proteo column (C{sub 12}) was investigated experimentally and modeled theoretically. The experimental equilibrium isotherms of LLL for adsorption on a C{sub 12} packing material from an aqueous solution of methanol (48%) and trifluoroacetic acid (0.1%) were measured by frontal analysis (FA). The FA measurements were done with two solutions, one in which the pH was controlled, the other in which it was not. Two solutions of LLL in the mobile phase were prepared (4.3 and 5.4 g/L) and their pH measured (2.94 and 2.88), respectively. The first solution was titrated with TFA to match the pH of the mobile phase (2.03), so its pH was controlled. The pH of the other solution was left uncontrolled. In both cases the isotherms could be modeled by a bi-Langmuir equation, a choice consistent with the bimodal affinity energy distribution (AED) obtained for LLL. The isotherm parameters derived from the inverse method (IM) of isotherm determination under controlled pH conditions (by fitting calculated profiles to experimental breakthrough profiles) are in a good agreement with those derived from the FA data. Under uncontrolled pH conditions, the application of IM suggests the coexistence of two different adsorption mechanisms. According to the isotherm parameters found by these three methods (FA, AED and IM), the C{sub 12}-bonded silica can adsorb around 500 and 70 g/L of LLL under controlled and uncontrolled pH conditions, respectively. The adsorption of LLL on the C{sub 12} material strongly depends on the pH of the mobile phase and on the quantity of TFA added, which plays the role of an ion-pairing agent.

10 SYNTHETIC FUELS↗

Sensitive ion detection device and method for analysis of compounds as vapors in gases

An ion mobility spectrometer (IMS) for the detection of trace gaseous molecular compounds dissolved or suspended in a carrier gas, particularly in ambient air, without preconcentration or the trapping of analyte particles. The IMS of the invention comprises an ionization volume of greater than 5 cm.sup.3 and preferably greater than 100 cm.sup.3. The larger size ionizers of this invention enable analysis of trace (<1 ppb) of sample compounds in the gas phase. To facilitate efficient ion motion through the large volume ionization and reaction regions of the IMS, an electric field gradient can be provided in the ionization region or in both the ionization and reaction regions. The systems can be implemented with radioactive ionization sources, corona discharge ion sources or ions can be formed by photoionization. In specific embodiments, particularly when the sample gas is ambient air, the sample gas is heater prior to entry into the instrument, the instrument is run at temperatures above ambient, and the instrument can be heated by contact with heated sample gas exiting the instrument.

47 OTHER INSTRUMENTATION↗

Sensitive ion detection device and method for analysis of compounds as vapors in gases

An ion mobility spectrometer (IMS) for the detection of trace gaseous molecular compounds dissolved or suspended in a carrier gas, particularly in ambient air, without preconcentration or the trapping of analyte particles. The IMS of the invention comprises an ionization volume of greater than 5 cm.sup.3 and preferably greater than 100 cm.sup.3. The larger size ionizers of this invention enable analysis of trace (<1 ppb) of sample compounds in the gas phase. To facilitate efficient ion motion through the large volume ionization and reaction regions of the IMS, an electric field gradient can be provided in the ionization region or in both the ionization and reaction regions. The systems can be implemented with radioactive ionization sources, corona discharge ion sources or ions can be formed by photoionization. In specific embodiments, particularly when the sample gas is ambient air, the sample gas is heater prior to entry into the instrument, the instrument is run at temperatures above ambient, and the instrument can be heated by contact with heated sample gas exiting the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NetMOD v. 1.0

NetMOD is a tool to model the performance of global ground-based explosion monitoring systems. The version 2.0 of the software supports the simulation of seismic, hydroacoustic, and infrasonic detection capability. The tool provides a user interface to execute simulations based upon a hypothetical definition of the monitoring system configuration, geophysical properties of the Earth, and detection analysis criteria. NetMOD will be distributed with a project file defining the basic performance characteristics of the International Monitoring System (IMS), a network of sensors operated by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO). Network modeling is needed to be able to assess and explain the potential effect of changes to the IMS, to prioritize station deployment and repair, and to assess the overall CTBTO monitoring capability currently and in the future. Currently the CTBTO uses version 1.0 of NetMOD, provided to them in early 2014. NetMOD will provide a modern tool that will cover all the simulations currently available and allow for the development of additional simulation capabilities of the IMS in the future. NetMOD simulates the performance of monitoring networks by estimating the relative amplitudes of the signal and noise measured at each of the stations within the network based upon known geophysical principles. From these signal and noise estimates, a probability of detection may be determined for each of the stations. The detection probabilities at each of the stations may then be combined to produce an estimate of the detection probability for the entire monitoring network.

Merchant, Bion J↗

The Journey to Vulnerability Management?

Abstract Text Idaho National Laboratory’s Information Management (IM) is transforming how they manage IT vulnerabilities. The IM team realized the increasing risks to the Lab and the difficulty of ‘keeping tabs’ on multiple organizations and multiple process for Vulnerability Management (VM). They chose to stand up an IT Operations and Vulnerability Management group to help centralize VM across IM organizations. Come listen and participate as we describe the on-going journey to facilitating a centralized vulnerability management operation. A mature VM program should provide a manageable life cycle for vulnerabilities and variances. In addition, the program must provide visibility to management and stakeholders for continuous monitoring and reporting of vulnerability discovery and remediation across Applications, Databases, Workstations, Servers, Infrastructure Equipment, and remediation of Variances.

97 MATHEMATICS AND COMPUTING↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Two-Dimensional Ion Mobility Analyses of Proteins and Peptides

INTRODUCTION-Analytical methods based on ion transport in gases under the influence of electric field, known collectively as Ion Mobility Spectrometry (IMS), add major new capabilities to mass-spectrometric (MS) investigations. Separation of ion mixtures and characterization of ions by IMS are of particular utility in biological MS, where the sample complexity creates a virtually open-ended demand for separation power (1) while the ion size normally rules out structural elucidation by spectroscopic means. The use of IMS in mass spectrometry of proteins and peptides has expanded dramatically since the previous edition of this volume in 2000...

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic multiplexed analysis method using ion mobility spectrometer

A method for multiplexed analysis using ion mobility spectrometer in which the effectiveness and efficiency of the multiplexed method is optimized by automatically adjusting rates of passage of analyte materials through an IMS drift tube during operation of the system. This automatic adjustment is performed by the IMS instrument itself after determining the appropriate levels of adjustment according to the method of the present invention. In one example, the adjustment of the rates of passage for these materials is determined by quantifying the total number of analyte molecules delivered to the ion trap in a preselected period of time, comparing this number to the charge capacity of the ion trap, selecting a gate opening sequence; and implementing the selected gate opening sequence to obtain a preselected rate of analytes within said IMS drift tube.

47 OTHER INSTRUMENTATION↗

Ion Mobility Mass Spectrometry Direct Isotope Abundance Analysis

The nuclear forensics community is currently engaged in the analysis of illicit nuclear or radioactive material for the purposes of non-proliferations and attribution. One technique commonly employed for gathering nuclear forensics information is isotope analysis. At present, the state-of-the-art methodology for obtaining isotopic distributions is thermal ionization mass spectrometry (TIMS). Although TIMS is highly accurate at determining isotope distributions, the technique requires an elementally pure sample to perform the measurement. The required radiochemical separations give rise to sample preparation times that can be in excess of one to two weeks. Clearly, the nuclear forensics community is in need of instrumentation and methods that can expedite their decision making process in the event of a radiological release or nuclear detonation. Accordingly, we are developing instrumentation that couples a high resolution IM drift cell to the front end of a MS. The IM cell provides a means of separating ions based upon their collision cross-section and mass-to-charge ratio (m/z). Two analytes with the same m/z, but with different collision cross-sections (shapes) would exit the cell at different times, essentially enabling the cell to function in a similar manner to a gas chromatography (GC) column. Thus, molecular and atomic isobaric interferences can be effectively removed from the ion beam. The mobility selected chemical species could then be introduced to a MS for high-resolution mass analysis to generate isotopic distributions of the target analytes. The outcome would be an IM/MS system capable of accurately measuring isotopic distributions while concurrently eliminating isobaric interferences and laboratory radiochemical sample preparation. The overall objective of this project is developing instrumentation and methods to produce near real-time isotope distributions with a modular mass spectrometric system that performs the required gas-phase chemistry and separations. The system couples a high-resolution ion mobility (IM) drift cell to the front end of a mass spectrometer (MS) allowing for chemical separation prior to isotope distribution analyses. This will yield isotope ratio measurement capabilities with minimal sample preparation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CTBT infrasound network performance to detect the 2013 Russian fireball event

The explosive fragmentation of the 2013 Chelyabinsk meteorite generated a large airburst with an equivalent yield of 500 kT TNT. It is the most energetic event recorded by the infrasound component of the Comprehensive Nuclear-Test-Ban Treaty-International Monitoring System (CTBT-IMS), globally detected by 20 out of 42 operational stations. This study performs a station-by-station estimation of the IMS detection capability to explain infrasound detections and nondetections from short to long distances, using the Chelyabinsk meteorite as global reference event. Investigated parameters influencing the detection capability are the directivity of the line source signal, the ducting of acoustic energy, and the individual noise conditions at each station. Findings include a clear detection preference for stations perpendicular to the meteorite trajectory, even over large distances. Only a weak influence of stratospheric ducting is observed for this low-frequency case. As a result, a strong dependence on the diurnal variability of background noise levels at each station is observed, favoring nocturnal detections.

58 GEOSCIENCES↗

Real-time Stack Monitoring at the BaTek Medical Isotope Production Facility

Radioxenon emissions from radiopharmaceutical production are a major source of background concentrations affecting the radioxenon detection systems of the International Monitoring System (IMS). Collection of real-time emissions data from production facilities makes it possible to screen out some medical isotope signatures from the IMS radioxenon data sets. This paper describes an effort to obtain and analyze real-time stack emissions data with the design, construction and installation of a small stack monitoring system developed by a joint CTBTO-IDC, BATAN, and PNNL team at the BaTek medical isotope production facility near Jakarta, Indonesia.

CTBTO↗

Low-Background Gamma Spectrometry for the International Monitoring System

PNNL has developed two very low-background gamma detectors housed in a new shallow underground laboratory. This new capability significantly improves our ability to detect trace amounts of airborne particulate that may be present in samples from the IMS field stations. The detectors were custom ordered to be fabricated using very low background materials. The combination of cosmic veto panels, dry nitrogen gas to reduce radon, low background shielding, and the shallow underground laboratory results in a reduction of the background count rate by a factor of 100 compared to an off –the-shelf commercial gamma detector operating above ground at our laboratory. Detection limits are thus reduced an order of magnitude.

gamma specgtroscopy, lo↗

Mobility-Selected Ion Trapping and Enrichment Using Structures for Lossless Ion Manipulations

The integration of ion mobility spectrometry (IMS) with mass spectrometry (MS) and the ability to trap ions in IMS-MS measurements is of great importance for performing reactions, accumulating ions, and increasing analytical measurement sensitivity. The development of Structures for Lossless Ion Manipulations (SLIM) offers the potential for ion manipulations in a more reliable and cost-effective manner, while opening opportunities for much more complex sequences of manipulations. Here, we demonstrate an ion separation and trapping module and a method based upon SLIM that consists of a linear mobility ion drift region, a switch/tee and a trapping region that allows the isolation and accumulation of mobility-separated species. The operation and optimization of the SLIM switch/tee and trap are described and demonstrated for the enrichment of the low abundance ions. Lastly, we observed a linear increase in ion intensity with the number of trapping/accumulation events using the SLIM trap, illustrating its potential for enhancing the sensitivity of low abundance or targeted species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LipidOz enables automated elucidation of lipid carbon–carbon double bond positions from ozone-induced dissociation mass spectrometry data

Lipids play essential roles in many biological processes and disease pathology, but unambiguous identification of lipids is complicated by the presence of multiple isomeric species differing by fatty acyl chain length, stereospecifically numbered (sn) position, and position/stereochemistry of double bonds. Conventional liquid chromatography-mass spectrometry (LC-MS/MS) analyses enable the determination of fatty acyl chain lengths (and in some cases sn position) and number of double bonds, but not carbon-carbon double bond positions. Ozone-induced dissociation (OzID) is a gas-phase oxidation reaction that produces characteristic fragments from lipids containing double bonds. OzID can be incorporated into ion mobility spectrometry (IMS)-MS instruments for the structural characterization of lipids, including additional isomer separation and confident assignment of double bond positions. The complexity and repetitive nature of OzID data analysis and lack of software tool support have limited the application of OzID for routine lipidomics studies. Here, we present an open-source Python tool, LipidOz, for the automated determination of lipid double bond positions from OzID-IMS-MS data, which employs a combination of traditional automation and deep learning approaches. Our results demonstrate the ability of LipidOz to robustly assign double bond positions for lipid standard mixtures and complex lipid extracts, enabling practical application of OzID for future lipidomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of Worldwide Radioxenon Backgrounds - The "EU" Project

Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), radioactive xenon (radioxenon) measurements are one of the principle techniques used to detect nuclear underground nuclear explosions, and specifically, the presence of one or more radioxenon isotopes allows one to determine whether a suspected event was a nuclear explosion or originated from an innocent source. During the design of the International Monitoring System (IMS), which was designed as the verification mechanism for the Treaty, it was determined that radioxenon measurements should be performed at 40 or more stations worldwide. At the time of the design of the IMS, however, very few details about the background of the xenon isotopes was known and it is now recognized that the backgrounds were probably evolving anyhow. This paper lays out the beginning of a study of the worldwide concentrations of xenon isotopes that can be used to detect nuclear explosions and several sources that also release radioxenons, and will have to be accounted for during analysis of atmospheric levels. Although the global concentrations of the xenon isotopes are the scope of a much larger activity that could span over several years, this study measures radioxenon concentrations in locations where there was either very little information or there was a unique opportunity to learn more about emissions from known sources. The locations where radioxenon levels were measured and reported are included.

background measurements↗

Modeling of fission and activation products in molten salt reactors and their potential impact on the radionuclide monitoring stations of the International Monitoring System

Molten Salt Reactors (MSRs) are one of six Generation IV reactor designs currently under development around the world. Because of the unique operating conditions of MSRs, which include molten fuel and the continuous removal of gaseous fission products during operation, work was performed to analyze the potential impact of emissions on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Simulations were performed to predict the production of IMS-relevant radionuclides in four MSR designs operating under two scenarios – (1) a sealed reactor with releases only during operational shutdown and (2) continuous reprocessing or sparging of the fuel salt. From these production estimates the radioxenon and radioiodine signatures were extracted and compared to three current reactor designs (PWR, BWR, RBMK). In the cases where continuous reprocessing of the fuel salt occurred both the radioxenon and radioiodine signatures are nearly indistinguishable from a nuclear explosion. Estimates were also made of the potential emission rate of radioxenon for three reactor designs and it was found that MSRs have the potential to emit radioxenon isotopes at a rate of 1015 – 8×1016 Bq/d for 133Xe if no abatement is used. An assessment was also made of activation products using a candidate fuel salt (FLiBe) mixed with corrosion products for the Thorium Molten Salt Reactor (TMSR-LF1)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LESSONS LEARNED IN AEROSOL MONITORING WITH THE RASA

The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

GENERATION OF RADIOXENON ISOTOPES

With the continued population of the International Monitoring System (IMS) network and the certification of radioxenon laboratory systems it has become necessary to calibrate and test these systems using as many of the radioxenon isotopes as possible. Several very promising techniques have been explored recently that allow for convenient production of Xe-133, Xe-131m, the short-lived isotope Xe-135, and even the difficult to obtain Xe-133m. IMS national and international laboratories have traditionally obtained Xe-133 from medical isotope suppliers. The activity of these medical dose samples is extremely high (~ 740 MBq) and requires very careful fume hood work to dilute down to appropriate levels (~ 10 Bq). By waiting for 10 or more half-lives it is possible to reduce the handling regimen considerably, while also obtaining a strong Xe-131m signature due to its longer half-life (11.9 days). The short-lived isotope Xe-135 (9.14 hrs) and the longer lived parent nuclide Xe-133m (2.2 day half-life) are never present in these samples. To obtain these isotopes another source or technique is required. This paper will discuss the two techniques developed and implemented at Pacific Northwest National Lab (PNNL) and show the results obtained from each technique. The first is an in-house method that allows for on demand production of two of these isotopes, Xe-133 and Xe-135, using HEU and a modest flux neutron source. The second method uses a research reactor at the Pullman campus of Washington State University to produce Xe-133, Xe-133m and Xe-135.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗