Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Microwave Heating-Induced Temperature Gradients in Liquid–Liquid Biphasic Systems

Microwaves (MWs) can enable the electrification and intensification of chemical manufacturing. They have been applied to various unit separations, such as drying, distillation, and extraction, entailing gas–liquid and solid–liquid systems. However, a limited quantitative understanding of MW-heated liquid–liquid biphasic systems related to extraction exists. This work measures the temporal and spatial temperature difference between an aqueous and an organic phase in batch and continuous microfluidic modes. We demonstrate permanent temperature differences between phases over 35 °C and spatiotemporal periodic and quasiperiodic oscillations modulated by the flow patterns. The temperature differences are primarily driven by the faster absorption rate of MW irradiation by the aqueous phase versus the slower heat transfer from the aqueous phase to the organic phase. These are amplified by low specific interfacial area and modifications of the electromagnetic field. We employ a multiphysics model to predict the temperature difference in a batch system. The model is in good agreement with the experiments. We demonstrate a strong effect of input power, dielectric properties of organic solvents, the volume of solvents, and the volume ratio between phases on the temperature difference. A simple analytical model describes the temperature difference and provides design principles. Furthermore, the combined approach offers new insights into the design and optimization of the MW-heated biphasic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of localized heating phenomena during microwave heating of mixed powders using in situ x-ray diffraction technique

In materials processing research using microwave heating, there have been several observations of various phenomena occurring known as microwave effects. One significant example of such a phenomenon is increased reaction kinetics. It is believed that there is a possibility that this might be caused by localized heating, were some reactants would attain a higher than apparent temperature. To examine whether such thermal gradients are indeed possible, mixed powders of two microwave non-absorbers, alumina and magnesia, were mixed with graphite, a known absorber, and heated in a microwave furnace. During microwave irradiation, the local temperatures of the respective sample constituents were measured using an in situ x-ray diffraction technique. In the case of the alumina and graphite sample, a temperature difference of around 100 °C could be observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron-cyclotron-resonance heating in Wendelstein 7-X: A versatile heating and current-drive method and a tool for in-depth physics studies

For stellarators, which need no or only small amounts of current drive, electron-cyclotron-resonance heating (ECRH) is a promising heating method even for the envisaged application in a fusion power plant. Wendelstein 7-X (W7-X) is equipped with a steady-state capable ECRH system, operating at 140 GHz, which corresponds to the 2nd cyclotron harmonic of the electrons at a magnetic field of 2.5 T. Ten gyrotrons are operational and already delivered 7 MW to W7-X plasmas. Combined with pellet injection, the highest triple product (0.68 × 10 20 keV m –3 s), observed up to now in stellarators, was achieved. For the first time, W7-X plasmas were sustained by 2nd harmonic O-mode heating, approaching the collisionality regime for which W7-X was optimized. Power deposition scans did not show any indication of electron temperature profile resilience. In low-density, low-power plasmas a compensation of the bootstrap current with electron-cyclotron current drive (ECCD) was demonstrated. Furthermore, sufficiently strong ECCD close to the plasma centre produced periodic internal plasma-crash events, which coincide with the appearance of low order rationals of the rotational transform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Reduced-Boundary-Function Method for Convective Heat Transfer with Axial Heat Conduction and Viscous Dissipation

We introduce a method of solution for the convective heat transfer under forced laminar flow that is confined by two parallel plates with a distance of 2a or by a circular tube with a radius of a. The advection-conduction equation is first mapped onto the boundary. The original problem of solving the unknown field is reduced to seek the solutions of T at the boundary (r=a or r=0, r is the distance from the centerline shown in Fig. 1), i.e. the boundary functions and/or . In this manner, the original problem is significantly simplified by reducing the problem dimensionality from 3 to 2. The unknown field can be eventually solved in terms of these boundary functions. The method is applied to the convective heat transfer with uniform wall temperature boundary condition and with heat exchange between flowing fluids and its surroundings that is relevant to the geothermal applications. Analytical solutions are presented and validated for the steady state problem using the proposed method.

Heat Transport, Convective, Conduction, Multi-scal↗

Exergetic design and analysis of a freeze-out heat exchanger for helium purification

The freeze-out purification process is very effective in removing moisture contamination and can be utilised for purification of helium gas in cryogenic applications. A process model for a freeze-out helium purifier (up to 30 g/s of contaminated helium at 10 ppmv) with a coiled finned-tube heat exchanger is developed. Furthermore, an extensive 1st and 2nd law (exergy) analysis is carried out and the exergetically optimal heat exchanger configuration (diameter and number of flow passes) for a given heat exchanger surface area ranging from 42.5 m 2 to 57.5 m 2 are found.

cryogenics↗

Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

15 GEOTHERMAL ENERGY↗

Cooling and Heating Season Impacts of Right-Sizing of Fixed- and Variable-Capacity Heat Pumps With Attic and Indoor Ductwork

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. They are controlled differently than standard fixed-capacity systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40% - 118% of nominal full capacity), thus staying 'on' for 60% - 100% more hours per day compared to fixed -capacity systems. Experiments in this research examined the performance of 2-ton and 3-ton fixed- and variable-capacity systems and the impacts of system oversizing.

BA-PIRC↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Dependence of Techno-Economic and Ecological Indicators of Flat-Plate Solar Water Heating Collectors in Hot Water Supply Systems from the Temperature of Heating Water

The main ways of improving the performance efficiency of solar energy (SE) use in hot water supply systems (HWSSs) are discussed. It is established that the environmental characteristics of flat-plate solar water heating collectors (FPSWHCs) for heating water in HWSSs depend on the water heating temperature in these systems.

14 SOLAR ENERGY↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaporative Heat Transfer Mechanisms within a Heat Melt Compactor

This paper will discuss the status of microgravity analysis and testing for the development of a Heat Melt Compactor (HMC). Since fluids behave completely differently in microgravity, the evaporation process for the HMC is expected to be different than in 1-g. A thermal model is developed to support the design and operation of the HMC. Also, low-gravity aircraft flight data is described to assess the point at which water may be squeezed out of the HMC during microgravity operation. For optimum heat transfer operation of the HMC, the compaction process should stop prior to any water exiting the HMC, but nevertheless seek to compact as much as possible to cause high heat transfer and therefore shorter evaporation times.

Heat Transfer↗

Phase transformations, heat evolution, and atomic diffusion during slow heating of Al-rich Al/Zr multilayered foils

We describe the energy and sequence of phase transformations in multilayered Al/Zr foils with atomic ratios of 3 Al:1 Zr during low temperature (<350 °C) heat treatments in a differential scanning calorimeter. The initial phase formed is an Al-rich amorphous phase that appears to grow by Zr diffusion through the amorphous phase. The subsequent nucleation and growth of tetragonal Al{sub 3}Zr along the Al/amorphous layer interface is mediated by Al diffusion through the crystalline intermetallic phase. Diffusion coefficients associated with these processes are higher than expected from reports of diffusivities measured at higher temperatures. The inferred heat of formation of the tetragonal Al{sub 3}Zr phase is 1240 ± 40 J/g (53 ± 2 kJ/mol atom). No anomalous variation in the energy or sequence of phase transformations is found with bilayer thickness for samples with bilayer thickness in the range of 17 nm to 90 nm despite anomalies in the bilayer dependence of self-propagating reaction velocities in the same foils.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MHD flow of a Casson fluid with power law heat flux and heat source

This investigation looks at the effects of thermal radiation on the magnetohydrodynamic flow of Casson fluid over a stretched surface subject to power law heat flux and internal heat generation. Conservation of mass, linear momentum and energy are used in the development of relevant flow equations. Series solutions for velocity and temperature are derived. Effects of embedded physical parameters on the velocity and temperature profiles are analyzed. Numerical values of skin-friction coefficient and local Nusselt number are examined.

42 ENGINEERING↗

Target-heating effects on the K{sub {alpha}{sub 1{sub ,{sub 2}}}}-emission spectrum from solid targets heated by laser-generated hot electrons

Target-heating effects on the K{sub {alpha}{sub 1{sub ,{sub 2}}}}-emission spectrum from small-mass Cu targets irradiated with 1-ps pulses focused to intensities >10{sup 18} W/cm{sup 2} have been observed. A collisional-radiative atomic physics model is unable to reproduce the time-integrated K{sub {alpha}{sub 1{sub ,{sub 2}}}}-emission spectrum from the smallest-mass targets when calculated with a single, time-independent thermal-electron temperature. When time-dependent heating to several hundred electron volts is included in the model, the synthetic spectra better reproduce the main observed spectral features.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilization of an Advanced Sensor network to determine fuel heating value and Real-Time net unit heat rate during transient operation

Coal-fired utility boilers are being increasingly used as variable electricity generation to resolve the imbalance in the energy market from the expansion of intermittent renewable energy. The frequent transient operation required to meet residual energy demand has created a challenge for coal-fired units to operate efficiently. This work utilizes an advanced sensor network (ASN) to calculate net unit heat rate (NUHR) of a coal-fired boiler in real time through combustion calculations and statistical correlations to provide the tools for optimizing dynamic operation. Real-time heating values that were necessary to determine fuel input energy to calculate accurate NUHR were found using both fundamental and data-driven methods. Real-time NUHR shows distinct shifts that reflect changes in process conditions that will improve the ability to optimize transient operation. Data-driven heating value correlations had 24% lower root mean square error (RMSE) than the fundamental combustion calculation approach when compared to daily retrospective proximate analysis. Furthermore, the data-driven method RMSE improved by 7% with the inclusion of ASN data. Future work is to validate by comparing unit performance with and without the inclusion of NUHR as a control parameter for the dynamic neural network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗