Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Water Vapor Measurements by Howard University Raman Lidar during the WAVES 2006 Campaign

Retrieval of water vapor mixing ratio using the Howard University Raman Lidar is presented with emphasis on three aspects: i) performance of the lidar against collocated radiosondes and Raman lidar, ii) investigation of the atmospheric state variables when poor agreement between lidar and radiosondes values occurred and iii) a comparison with satellite-based measurements. The measurements were acquired during the Water Vapor Validation Experiment Sondes/Satellites 2006 field campaign. Ensemble averaging of water vapor mixing ratio data from ten night-time comparisons with Vaisala RS92 radiosondes shows on average an agreement within 10 % up to approx. 8 km. A similar analysis of lidar-to-lidar data of over 700 profiles revealed an agreement to within 20 % over the first 7 km (10 % below 4 km). A grid analysis, defined in the temperature - relative humidity space, was developed to characterize the lidar - radiosonde agreement and quantitatively localizes regions of strong and weak correlations as a function of altitude, temperature or relative humidity. Three main regions of weak correlation emerge: i) regions of low relative humidity and low temperature, ii) moderate relative humidity at low temperatures and iii) low relative humidity at moderate temperatures. Comparison of Atmospheric InfraRed Sounder and Tropospheric Emission Sounder satellites retrievals of moisture with that of Howard University Raman Lidar showed a general agreement in the trend but the formers miss a lot of the details in atmospheric structure due to their low resolution. A relative difference of about 20 % is usually found between lidar and satellites measurements.

Adam, M.↗

Characteristics of Mesoscale Organization in WRF Simulations of Convection during TWP-ICE

Compared to satellite-derived heating profiles, the Goddard Institute for Space Studies general circulation model (GCM) convective heating is too deep and its stratiform upper-level heating is too weak. This deficiency highlights the need for GCMs to parameterize the mesoscale organization of convection. Cloud-resolving model simulations of convection near Darwin, Australia, in weak wind shear environments of different humidities are used to characterize mesoscale organization processes and to provide parameterization guidance. Downdraft cold pools appear to stimulate further deep convection both through their effect on eddy size and vertical velocity. Anomalously humid air surrounds updrafts, reducing the efficacy of entrainment. Recovery of cold pool properties to ambient conditions over 5-6 h proceeds differently over land and ocean. Over ocean increased surface fluxes restore the cold pool to prestorm conditions. Over land surface fluxes are suppressed in the cold pool region; temperature decreases and humidity increases, and both then remain nearly constant, while the undisturbed environment cools diurnally. The upper-troposphere stratiform rain region area lags convection by 5-6 h under humid active monsoon conditions but by only 1-2 h during drier break periods, suggesting that mesoscale organization is more readily sustained in a humid environment. Stratiform region hydrometeor mixing ratio lags convection by 0-2 h, suggesting that it is strongly influenced by detrainment from convective updrafts. Small stratiform region temperature anomalies suggest that a mesoscale updraft parameterization initialized with properties of buoyant detrained air and evolving to a balance between diabatic heating and adiabatic cooling might be a plausible approach for GCMs.

Del Genio, Anthony D.↗

Impact of Convectively Detrained Ice Crystals on the Tropical Upper Troposphere and Lower Stratosphere

The role of convectively detrained ice crystals on the humidity of the tropical upper troposphere and lower stratosphere (UTLS) is investigated in simulations of cirrus clouds along trajectories launched from the 378K potential temperature level in the tropics. The one-dimensional (vertical) cloud model tracks individual ice crystals through their lifecycle beginning with detrainment from convection, followed by deposition growth, sedimentation and sublimation. Convective influence of the parcels is diagnosed by tracing the trajectories through time-dependent fields of convective cloud-top height adjusted to match the CloudSAT and CALIPSO statistics. Model simulations of UTLS water vapor and cloud fields are evaluated and constrained by comparison with Aura MLS and CALIPSO measurements. Preliminary results indicate sensitivity of the detrained ice crystal lifecycle to atmospheric conditions downstream of convection. Specifically, cooling (high relative humidity and supersaturation) downstream of convection leads to deposition growth and sedimentation of detrained ice crystals, resulting in net dehydration of the UTLS. In contrast, warming (low relative humidity and subsaturation) downstream of convection leads to sublimation of detrained ice crystals and subsequent hydration. As such, the impact of detrained ice crystals on the humidity of the UTLS exhibits distinct spatial variability. Detrained ice crystals predominantly dehydrate the UTLS in the tropical mean. Sensitivities to the convectively detrained ice crystal size and concentration are also examined using measurements from the StatoClim aircraft campaign. The importance of convectively detrained ice crystals will be discussed within the context of the overall contribution of convection to the lower stratospheric humidity.

Ueyama, Rei↗

Evaporation from the Southern Ocean Estimated on the Basis of AIRS Satellite Data

Evaporation plays an important role in the global water and energy cycles and, hence, in climate change. Evaporation over the Southern Ocean, where the Antarctic sea ice coverage has a large annual cycle, is poorly quantified. In this study, daily evaporation is estimated for the Southern Ocean with a sea‐ice‐specific algorithm, using surface temperature and air humidity from National Aeronautics and Space Administration's Atmospheric Infrared Sounder (AIRS), and wind speeds from Modern‐Era Retrospective Analysis for Research and Applications, Version 2 (MERRA‐2), reanalysis during 2003–2016. An uncertainty of 34% was found in the evaporation product. The results indicate that annual evaporation has considerable interannual and regional variability, but with a decreasing trend during the study period over most of the Southern Ocean. There are, however, areas where evaporation has increased, specifically in the Ross Sea in winter and summer, with smaller positive trends in spring and fall. Overall, the changes in the difference between the surface specific humidity and the air specific humidity, and to a much lesser extent in the wind speed, are the main drivers for the changes in evaporation throughout the year. During spring and fall months, changes to the sea ice cover, which alter the surface specific humidity, are the main drivers for the change, but in summer and winter the main driver is the air‐specific humidity. Air masses originating from the Antarctic continent (south) are associated with cold and dry conditions, which increase evaporation, whereas air masses from lower latitudes in the Southern Ocean (north) are associated with warm and moist conditions, decreasing evaporation. Comparisons with other reanalysis evaporation products produce similar trends, although annual averages differ.

Boisvert, Linette↗

Statistical Analysis of Factors Riving Surface Ozone Variability over Continental South Africa

Statistical relationships between surface ozone (O3) concentration, precursor species and meteorological conditions in continental South Africa were examined from data obtained from measurement stations in north-eastern South Africa. Three multivariate statistical methods were applied in the investigation, i.e. multiple linear regression (MLR), principal component analysis (PCA) and –regression (PCR), and generalised additive model (GAM) analysis. The daily maximum 8-h moving average O3 concentrations were considered in these statistical models (dependent variable). MLR models indicated that meteorology and precursor species concentrations are able to explain ~50% of the variability in daily maximum O3 levels. MLR analysis revealed that atmospheric carbon monoxide (CO), temperature and relative humidity were the strongest factors affecting the daily O3 variability. In summer, daily O3 variances were mostly associated with relative humidity, while winter O3 levels were mostly linked to temperature and CO. PCA indicated that CO, temperature and relative humidity were not strongly collinear. GAM also identified CO, temperature and relative humidity as the strongest factors affecting the daily variation of O3. Partial residual plots found that temperature, radiation and nitrogen oxides most likely have a non-linear relationship with O3,while the relationship with relative humidity and CO is probably linear. An inter-comparison between O3 levels modelled with the three statistical models compared to measured O3 concentrations showed that the GAM model offered a slight improvement over the MLR model. These findings emphasise the critical role of regional-scale O3 precursors coupled with meteorological conditions in daily variances of O3 levels in continental South Africa.

multiple linear regression (MLR)↗

Impact of an SRA (hexylene glycol) on irreversible drying shrinkage and pore solution properties of cement pastes

Cementitious materials shrink when exposed to decreasing relative humidities, which may result in cracking. Shrinkage reducing admixtures (SRAs) can be used to reduce this drying shrinkage. Although many studies have shown that SRAs reduce the surface tension of the pore solution, the effects of SRAs on other pore solution properties and their relationship to drying shrinkage have been poorly characterized. In this work, we investigate the impact of an SRA (hexylene glycol) on the drying and re-humidification of a cement paste over an extended relative humidity range. The reduction in the first drying shrinkage by the SRA depends on relative humidity. The SRA also significantly reduces the irreversible drying shrinkage. We concluded that the SRA impacts drying shrinkage by acting on the capillary forces, by acting on the specific range of relative humidity over which those forces occur, and potentially by acting on the surface stresses through pore wall adsorption.

36 MATERIALS SCIENCE↗

Impact of Controlled Storage Conditions on the Hydrolysis and Surface Morphology of Amorphous-UO 3

The hydration and morphological effects of amorphous (A)-UO 3 following storage under varying temperature and relative humidity have been investigated. This study provides valuable insight into U-oxide speciation following aging, the U-oxide quantitative morphological data set, and, overall, the characterization of nuclear material provenance. A-UO 3 was synthesized via the washed uranyl peroxide synthetic route and aged based on a 3-factor circumscribed central composite design of experiment. Target aging times include 2.57, 7.00, 14.0, 21.0, and 25.4 days, temperatures of 5.51, 15.0, 30.0, 45.0, and 54.5 °C, and relative humidities of 14.2, 30.0, 55.0, 80.0, and 95.8% were examined. Following aging, crystallographic changes were quantified via powder X-ray diffraction and an internal standard Rietveld refinement method was used to confirm the hydration of A-UO 3 to crystalline schoepite phases. The particle morphology from scanning electron microscopy images was quantified using both the Morphological Analysis of MAterials software and machine learning. Results from the machine learning were processed via agglomerative hierarchical clustering analysis to distinguish trends in morphological attributes from the aging study. Significantly hydrated samples were found to have a much larger, plate-like morphology in comparison to the unaged controls. Predictive modeling via a response surface methodology determined that while aging time, temperature, and relative humidity all have a quantifiable effect on A-UO 3 crystallographic and morphological changes, relative humidity has the most significant impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Daily grass reference evapotranspiration with Meteosat Second Generation shortwave radiation and reference ET products

Here we assess the accuracy of estimating daily grass reference evapotranspiration (PM-ET o ) using daily shortwave radiation (R s ) and reference evapotranspiration (ET REF ) products provided by the Meteosat Second Generation (MSG) geostationary satellite delivered by the Satellite Applications Facility on Land Surface Analysis (LSA-SAF) framework. The accuracy of using reanalysis ERA5 shortwave radiation data (R s ERA5 ) provided by the European Center for Medium-Range Weather Forecasts (ECMWF) is also evaluated. The assessments were performed using observed weather variables at 37 weather stations distributed across continental Portugal, where climate conditions range from semi-arid to humid, and 12 weather stations located in Azores islands, characterized by humid, windy and often cloudy conditions. This study&#x27;s use of data from a variety of climate conditions contributed to a unique and innovative assessment of the usability of LSA-SAF and ERA5 products for ET o estimation. The first assessment focused on comparing LSA-SAF estimates of R s (R s LSA-SAF ) against ground stations (R s ground ). The results showed a good matching between the two R s data sets for continental Portugal but a tendency for R s LSA-SAF to under-estimate R s ground in the cloudy islands of Azores. ET o values computed using R s LSA-SAF data and observed temperature, humidity and wind speed (ET o LSA-SAF ) were then compared with PM-ET o estimates with ground-based data, which were used as benchmark; input data of temperature and humidity needed for PM-ET o were quality checked for surface aridity effects. It was observed that ET o LSA-SAF is strongly correlated with PM-ET o (R 2 > 0.97) for most locations in continental Portugal, with regression coefficient of a linear regression forced to the origin ranging between 0.95 and 1.05, mean root mean square error (RMSE) of 0.13 mm d –1 , and Nash and Sutcliff efficiency of modeling (EF) above 0.95. For most Azores locations, ET o LSA-SAF over-estimated PM-ET o . This is likely a consequence of the high spatio-temporal heterogeneity of weather conditions that occur in these oceanic islands together with the different footprints of satellite (averaged over the pixel) and station observations. Reanalysis ERA5 shortwave radiation data presented similar behavior to the LSA-SAF products, however with slightly lower accuracy. The daily LSA-SAF ET REF product (ET REF LSA-SAF ) was assessed and results have shown a good accuracy of this product, with acceptable RMSE and high EF values, for continental Portugal but a low accuracy for the Azores islands. A simplified bias correction approach was shown to improve both ET o derived from the LSA-SAF products, namely for Azores stations, which seem to be representative of smaller areas. The use of the FAO-PM temperature approach (PMT) was also assessed using the R s LSA-SAF and R s ERA5 data, which showed a superiority of the LSA-SAF product for ET o estimations (ET o PMT LSA-SAF ). No significant differences (p < 0.05) were observed in terms of the median value of the RMSE when adopting ET o PMT and ET REF LSA-SAF . Differently, results showed that using the R s LSA-SAF in the PMT approach (ET o PMT LSA-SAF ) produces significantly better RMSE results than ET o PMT and ET REF LSA-SAF . Overall, the performed assessment allows concluding that the use of R s LSA-SAF, and to a lesser extent the use of the R s ERA5 , highly improves the accuracy of computation of ET o when R s observations are not available, including when only temperature data are accessible. The use of the ET REF LSA-SAF product is a good alternative when observed weather data are not available.

54 ENVIRONMENTAL SCIENCES↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

An international study on THM modelling of the full-scale heater experiment at Mont Terri laboratory

We present results from an international model comparison study of the Full-Scale Emplacement (FE) experiment in Opalinus Clay at the Mont Terri Laboratory, Switzerland. Based on a provided parameter set the teams decided which parameters they adopted for their models, whether they considered the excavation and the ventilation phase in addition to the heating phase and if they included technical features like the shotcrete or the EDZ. The teams were able to reproduce the measured parameters temperature, relative humidity and pore pressure. The modelled results for temperature agree very closely between the teams especially in the sensors in Opalinus Clay. All teams were able to reproduce the redistribution of water in the bentonite backfill due to heating. The evolution of the relative humidity showed similar trends with differences in the intensity of the dry out effect. To model the pore pressure evolution is more complex because it comprises the full interaction of the coupled THM processes. The spread between the pore pressure modelled by the teams was larger, with some teams overestimating the pressure increase due to heating and some teams overestimating the extent of drainage. The agreement of modelled results with measurements improves with larger distance to the heater. We conclude that the EDZ and the shotcrete potentially influence the behaviour of the rock causing higher differences closer to the heater. Further research is needed to better implement those influences into the models. Based on the calibrated models, the future evolution of temperature, relative humidity and pore pressure was predicted over the next 10 years following a change of the heat power applied in 2023 and 2024. Again, the predicted temperatures agree very closely between the teams. Most teams do not expect an increase in relative humidity during the next 10 years after the initial dry-out.

58 GEOSCIENCES↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coupled neutronics, thermochemistry, corrosion modeling and sensitivity analyses for isotopic evolution in molten salt reactors

This study presents a computational methodology for analyzing isotopic evolution and associated uncertainties in molten salt reactors (MSRs), focusing on both fluoride- and chloride-based fuel salts. The primary goal is to enhance the understanding of isotopic behavior in MSRs and provide data to support future experimental efforts. The methodology integrates transport-coupled depletion calculations using OpenMC, equilibrium thermodynamics modeling with Thermochimica, and a corrosion model. Sensitivity analyses are performed to evaluate the impact of power density, air ingress, and humidity content on isotopic evolution in MSR concepts. This study examines representative F- and Cl-based MSR designs, highlighting the dominant influence of power density on isotopic composition, which significantly affects isotope production and depletion rates, accounting for approximately 76% of the observed variance in element concentration. Air ingress and humidity content also affect the redox potential, solubility of heavier elements, and corrosion rates, thereby altering the expected isotopic evolution in the reactor. On average, air ingress accounts for around 17% of the variance in element concentrations, while humidity explains the remaining 7%. These variances differ significantly from element to element, depending on the element’s role in depletion, redox potential evolution, and galvanic corrosion. The findings indicate that power density, air ingress, and humidity content are all critical factors for optimizing reactor design and operational strategies. Furthermore, the study provides expected ranges for key impurities in the fuel salt, which are crucial for guiding future experimental studies and refining MSR designs. Finally, this study demonstrates the importance of modeling depletion coupled with the evolution of redox potential and chemical interactions in MSR fuel salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hygrothermal aging effects on polyimide and acrylate-based adhesive materials in high-performance flat-flex cable assemblies

Flat-flex assemblies are widely used across a diverse range of technologies, including consumer electronics, automotive systems, aerospace and defense applications, and medical devices, due to their compact form factor and flexibility. However, environmental stressors like temperature and humidity are known to degrade performance over time, though the main mechanisms for degradation remain unknown. Here, in this work, we examined the aging behavior of copper/polyimide/adhesive laminate systems under varying temperature and humidity conditions, focusing on material degradation and its effects on mechanical and dielectric properties. Results show that peel strength and breakdown voltage decrease with exposure time, temperature, and humidity; spectroscopic characterization revealed that the adhesive, and not the polyimide, is the weak link in the material stack-up. The adhesive, identified as a butyl acrylate-acrylonitrile (BA-AN) copolymer, exhibited age-related spectral changes that correlated with exposure severity and duration. Hydrolysis at BA ester and AN nitrile groups was identified as the primary degradation mechanism, producing amides, acids, and alcohols. We developed a mechanistic model that connects kinetic parameters for BA-AN spectral band decay to peel strength and breakdown voltage, and implicates hydrolysis at the AN moiety, not BA, in performance decrements. Modeling predictions at ambient conditions indicate faster decline in peel strength than dielectric strength at early times, followed by plateauing of both properties at longer times. These findings provide critical insights into laminate aging mechanisms and highlight the importance of addressing BA-AN degradation to improve the long-term reliability of these systems in high-humidity environments.

organic↗

Frictional Contacts Between Individual Woody Biomass Particles under Wet and Dry Conditions

Friction between wood particles can be a critical property when designing processing equipment for creating cellulosic biofuels and similar natural products. Also, as wood processing is likely to occur year-round, understanding the friction between wet as well as dry wood particles can help design and model equipment, such as screw feeders. Here, a tribo-rheometry method was developed using a commercial rheometer that measured the torque required to rotate two contacting millimeter-scale wood chip particles. First, a range of normal forces were used to find the limits of the experimental method. Torque values were measured for seven pairs of wood chip particles at 1 N normal force under both dry and wet conditions, at both ambient conditions and in a humidity-controlled chamber. The torque required to rotate the wet particles was consistently higher than that of the dry particles, although differences were not quite statistically significant when measurements were performed at ambient conditions. Using humidity control resulted in torque values for wet particles of 1900 uNm and 900 uNm for dry particles. Finally, the friction coefficient was calculated as 0.23 for wet particles and 0.11 for dry particles when humidity was controlled. These frictions coefficients agreed with values for wood reported in the literature. Overall, controlling humidity is strongly recommended to quantify the range of friction for particles that uptake water, including granular systems from biomass to food to powders.

biomass↗

Radiation-induced molecular hydrogen gas generation in the presence of aluminum alloy 1100

The United States government currently manages nearly 13 metric tons of aluminum-clad spent nuclear fuel (SNF) without a long-term storage solution, so a fundamental understanding of corrosion processes occurring on aluminum alloy surfaces is of utmost importance to plan for extended (>50 years) interim dry storage of aluminum-clad SNF. While thermal and chemical corrosion processes are well characterized for aluminum, radiation effects are not. To help understand the impacts of radiation on aluminum-clad SNF, here the radiation-induced molecular hydrogen gas (H 2 ) generation from pristine and pre-corroded aluminum alloy 1100 (Al-1100) coupons have been studied. Corrosion of coupons was achieved by submerging coupons in water at 95 °C for 29 days, yielding a ~5 μm boehmite/bayerite oxide film. Pre-corroded coupons were exposed to cobalt-60 gamma radiation to absorbed doses of up to 1.0 MGy under a variety of conditions: cover-gas composition (argon, nitrogen, or air), relative humidity (0, 50, and 100%), and temperature (ambient, 100, and 200 °C). Post-irradiation measurements demonstrated that the yield of H 2 was directly attributable to the presence of the Al-1100 coupons and their physisorbed water with dependence on absorbed gamma dose, relative humidity, and cover-gas composition. No H 2 was quantified in the presence of air, while both nitrogen and argon environments afforded higher H 2 yields with increasing relative humidities. This was attributed to the greater availability of adsorbed water for radiolytic processes. Irradiation of pre-corroded Al-1100 coupons at different temperatures under 0% relative humidity argon conditions yielded statistically equivalent H 2 yields for ambient temperatures and 100 °C. However, irradiation at 200 °C promoted a 3 to 4-fold increase in the yield of H 2 , possibly due to the transformation of bayerite to boehmite and/or improved efficiency of H • and H 2 release from oxide surfaces.

36 MATERIALS SCIENCE↗