Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Integration of an Arm Kinematics Hot Patch onboard the Curiosity Rover

NASA's Mars Science Laboratory (MSL) mission has updated the Curiosity rover's flight software multiple times since landing on Mars on August 6, 2012. The most common patching method has been a hot patch, in which running flight software is modified after being copied into RAM from its persistent storage. The latest hot patch to be installed on Curiosity fixed an issue in the robotic arm software that computes generalized inverse kinematics. Additional unit testing performed since the start of the surface mission revealed that this software can sometimes produce erroneous solutions.The cause was identified as numerical instability in a quartic root finder. When the inputs to that solver are not well conditioned, floating-point numerical issuescan cause erroneous roots to be reported. In theory, this could result in the robotic arm turret instruments being commanded to unintended positions, for example, below the terrain surface. Out of approximately 3.7 million unit test cases, 97.2\% of the position errors were below 5 mm. However, there were 16 test cases where theposition error was greater than 20 cm, and the maximum position error was 1.2 meters.The patch was uploaded to Curiosity on sol 2642 (January 11, 2020) after the solution was developed, re-implemented as a hot patch, and validated and verified using Earth-based Curiosity testbeds. A checkout test of the patch was performed on Curiosity on sol 2657, and nominal use of the patch began on sol 2658. In this paper, we describe the steps that led to integrating the arm kinematic hot patch into Curiosity's flight software, from the discovery of the bug to the nominal use of the patch in flight.

Maimone, Mark↗

Exploring the Limits of the Data-Model-Theory Synergy: “Hot” MW Transitions for Rovibrational IR Studies

In order to further improve the accuracy of rovibrational IR line lists generated from the “Best Theory +Reliable High-resolution Experiment” (BTRHE) strategy from 0.01-0.05 cm-1, or 300-1500 MHz, to ~10 MHz, we explore the current limits of the Data-Model-Theory synergy by examining the accuracy and consistency of existing data, then propose that “hot” bands in microwave (MW) spectra is the solution we need for future enhancements. The Ames SO2 J=0-20 rovibrational energy levels computed on the semi-empirically refined Ames-2 potential energy surface (PES) are fit to the Effective Hamiltonian (EH) model regularly used in the experimental infrared (IR) analysis for SO2 isotopologues. In the fitted EH(Ames) model, the rotational constants A/B/C and all 5 quartic centrifugal distortion constants display clear, systematic, and consistent patterns along the vibrational state energy or quanta. Such consistent patterns may facilitate the vibrational assignments for MW hot bands and extract more information from high temperature MW spectra. Some EH(Expt) analyses were carried out with the lowest order Coriolis Coupling term, C1. Their constants should not be directly compared with other EH(Expt) and EH(Ames) results. After excluding them, our  = EH(Ames)- EH(Expt) analyses for 5 isotopologues (626, 636, 646, 628 and 828) indicates some loss of accuracy and consistency starting from vibrational states as low as 22 or 1000 cm-1. Some EH parameters, e.g. K, may have relative deviations as large as 50-100% and totally lose any recognizable patterns. This simply means that current EH(Expt) models do not have the system-wide consistency we need to further refine the EH(Ames) and Ames rovibrational IR line lists. A large part of such defects are probably inherited from the limited precision of experimental line positions, i.e. 1E-3 ~ 1E-4 cm-1, or 3-30 MHz. This is confirmed in a series of truncation tests using the Ames data. Although the EH(Ames) consistency may help identify unreliable rovibrational EH(Expt) parameters, and make reliable predictions for minor isotopologues and unobserved vibrational bands, we believe only the highly accurate “hot” MW transitions can provide real enhancements for EH(Expt) accuracy and consistency. “Hot” MW spectra should play a more significant role in the future synergy of Data, Model, and Theory in the field of rovibrational IR studies.

Xinchuan Huang↗

Structural Dynamics Observations in Space Launch System Green Run Hot Fire Testing

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of eight mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. The Green Run Hot Fire (GRHF) of the SLS Core Stage provided a flight-like ground test environment for verification of integrated vehicle TVC performance. A TVC model coupled to a vehicle structural dynamic model has been developed previously and incrementally validated in subsystem tests and simulations. Still, some aspects of TVC performance in GRHF were not anticipated. The ensuing investigation demonstrated the need for well-instrumented test environments, various levels of modeling fidelity, test-representative structural models, and caution in reuse of legacy components. This paper is the sixth installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. It introduces the salient structural dynamic phenomena uncovered in ambient and hot fire testing. During the Green Run test campaign, a comparison of ambient and hot fire step responses showed a significant change in apparent damping due to the presence of friction, challenging long standing assumptions that friction could be neglected. Additionally, the characteristic response of the engine and thrust structure during GRHF proved to be more complex than anticipated, as evidenced by the available actuator, thrust structure, and engine measurements. While the string-potentiometer based test instrumentation was intended to allow for reconstruction of the engine angles along the two control axes, the geometric placement, location uncertainty, and responses in overlapping frequency spectra revealed additional phenomena requiring further analysis and post-processing. The observations from both modal and frequency response testing during the Green Run ambient and hot fire configurations led to Engine and Core Stage FEM (finite element model) updates. When evidence of unexpected engine motion was found in engine section accelerometer data, the authors pursued additional structural analysis leading to FEM updates associated with the TVC gimbal and thrust structure. Through collaboration between structures, TVC, and flight control disciplines, the test-informed models and root-cause analysis led to confident flight rationale for the first flight of the SLS launch vehicle.

Richard K. Moore↗

Structural Dynamics Observations in Space Launch System Green Run Hot Fire Testing

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of eight mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. The Green Run Hot Fire (GRHF) of the SLS Core Stage provided a flight-like ground test environment for verification of integrated vehicle TVC performance. A TVC model coupled to a vehicle structural dynamic model has been developed previously and incrementally validated in subsystem tests and simulations. Still, some aspects of TVC performance in GRHF were not anticipated. The ensuing investigation demonstrated the need for well-instrumented test environments, various levels of modeling fidelity, test-representative structural models, and caution in reuse of legacy components. This paper is the sixth installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. It introduces the salient structural dynamic phenomena uncovered in ambient and hot fire testing. During the Green Run test campaign, a comparison of ambient and hot fire step responses showed a significant change in apparent damping due to the presence of friction, challenging long standing assumptions that friction could be neglected. Additionally, the characteristic response of the engine and thrust structure during GRHF proved to be more complex than anticipated, as evidenced by the available actuator, thrust structure, and engine measurements. While the string-potentiometer based test instrumentation was intended to allow for reconstruction of the engine angles along the two control axes, the geometric placement, location uncertainty, and responses in overlapping frequency spectra revealed additional phenomena requiring further analysis and post-processing. The observations from both modal and frequency response testing during the Green Run ambient and hot fire configurations led to Engine and Core Stage FEM (finite element model) updates. When evidence of unexpected engine motion was found in engine section accelerometer data, the authors pursued additional structural analysis leading to FEM updates associated with the TVC gimbal and thrust structure. Through collaboration between structures, TVC, and flight control disciplines, the test-informed models and root-cause analysis led to confident flight rationale for the first flight of the SLS launch vehicle.

Richard Moore↗

Sampling Tools for Contaminated Hot Cells and Remotely Accessed Tanks

The U.S. Department of Energy (DOE) and the Pacific Northwest National Laboratory in collaboration with the Andronikashvili Institute of Physics in Tbilisi, Georgia have developed and tested technologies which sample contaminated areas inside hot cell facilities. Sampling locations in the facility include drains, ventilation exhaust ducts, sumps and shielded waste tanks. Tool designs for sampling each location include the ability to introduce the tool using existing ports, pass-throughs or inter-cells trolley and operate the tool with the existing remote manipulators. Areas inside the hot cell facility that would likely be contaminated from chemically processing irradiated reactor targets and fuel even after decontamination have been identified as potential sampling locations. Andronikashvili Institute of Physics in Tbilisi, Georgia has access to a reactor, hot cells, glove boxes and storage facilities that have been used to develop and test hot cell sampling technologies. These facilities are uncontaminated with radiological material and provide the ability to test these sampling technologies on representative equipment without contaminating the tools. Prototype tools have been fabricate and tested at these facilities using simulants representative of radiological contamination and waste.

Rostomashvili, Z.↗

Sealed Attics Exposed to Two Years of Weathering in a Hot and Humid Climate

Field studies in a hot, humid climate were conducted to investigate the thermal and hygrothermal performance of ventilated attics and non-ventilated semi-conditioned attics sealed with open-cell and with closed-cell spray polyurethane foam insulation. Moisture pin measurements made in the sheathing and absolute humidity sensor data from inside the foam and from the attic air show that moisture is being stored in the foam. The moisture in the foam diffuses to and from the sheathing dependent on the pressure gradient at the foam-sheathing interface which is driven by the irradiance and night-sky radiation. Ventilated attics in the same hot, humid climate showed less moisture movement in the sheathing than those sealed with either open- or closed-cell spray foam. In the ventilated attics the relative humidity drops as the attic air warms; however, the opposite was observed in the sealed attics. Peaks in measured relative humidity in excess of 80 90% and occasionally near saturation (i.e., 100%) were observed from solar noon till about 8 PM on hot, humid days. The conditioned space of the test facility is heated and cooled by an air-to-air heat pump. Therefore the partial pressure of the indoor air during peak irradiance is almost always less than that observed in the sealed attics. Field data will be presented to bring to light the critical humidity control issues in sealed attics exposed to hot, humid climates.

insulation↗

Prediction of countercurrent flow limitation and its uncertainty in a PWR hot leg

In previous studies, we did small-scale air-water experiments for the hot leg and pressurizer surge line in a PWR and three-dimensional (3D) numerical simulations for PWR conditions to evaluate countercurrent flow limitation (CCFL) there, and we developed a one-dimensional (1D) prediction method to generalize prediction of CCFL in a piping system such as the hot leg and pressurizer surge line. In this study, we evaluated computation errors of the 1D prediction method in comparison with CCFL data in the PWR hot leg models with the diameter D and length L of D = 50-650 mm and L/D = 4.5-9.5, and then evaluated uncertainties of the 1D prediction method in comparison with 3D numerical simulations for PWR conditions with D = 750 mm and L/D = 8.6. We found the computation errors were within the difference of dC = ±0.05 for the CCFL constant of C = 0.63 in the correlation with the Wallis parameters, but the computation errors include experimental errors and they are not uncertainties for the PWR conditions. The total uncertainty of the 1D computations for the actual PWR hot leg (including effects of the diameter and fluid properties) was estimated to be dC = ±0.035. The CCFL correlation and its uncertainty of dC = ±0.035 derived from the 1D prediction method were very close to those previously obtained from CCFL data and 3D simulations (dC = ±0.03). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Slip and Dilation Tendency Analysis of Neal Hot Springs Geothermal Area

Slip and Dilation Tendency in focus areas Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an indication of which faults or fault segments within a geothermal system are critically stressed and therefore likely to transmit geothermal fluids. The slip tendency of a surface is defined by the ratio of shear stress to normal stress on that surface: Ts = T / on (Morris et al., 1996). Dilation tendency is defined by the stress acting normal to a given surface: Td = (o1-on) / (o1-o3) (Ferrill et al., 1999). Slip and dilation were calculated using 3DStress (Southwest Research Institute). Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the fault plane by ambient stress conditions. Values range from a maximum of 1, a fault plane ideally oriented to slip or dilate under ambient stress conditions to zero, a fault plane with no potential to slip or dilate. Slip and dilation tendency values were calculated for each fault in the focus study areas at, McGinness Hills, Neal Hot Springs, Patua, Salt Wells, San Emidio, and Tuscarora on fault traces. As dip is not well constrained or unknown for many faults mapped in within these we made these calculations using the dip for each fault that would yield the maximum slip tendency or dilation tendency. As such, these results should be viewed as maximum tendency of each fault to slip or dilate. The resulting along-fault and fault-to-fault variation in slip or dilation potential is a proxy for along fault and fault-to-fault variation in fluid flow conduit potential. Stress Magnitudes and directions Stress field variation within each focus area was approximated based on regional published data and the world stress database (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2010; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012; Moeck et al., 2010; Moos and Ronne, 2010 and Reinecker et al., 2005) as well as local stress information if applicable. For faults within these focus systems we applied either a normal faulting stress regime where the vertical stress (sv) is larger than the maximum horizontal stress (shmax) which is larger than the minimum horizontal stress (sv>shmax>shmin) or strike-slip faulting stress regime where the maximum horizontal stress (shmax) is larger than the vertical stress (sv) which is larger than the minimum horizontal stress (shmax >sv>shmin) depending on the general tectonic province of the system. Based on visual inspection of the limited stress magnitude data in the Great Basin we used magnitudes such that shmin/shmax = .527 and shmin/sv= .46, which are consistent with complete and partial stress field determinations from Desert Peak, Coso, the Fallon area and Dixie valley (Hickman et al., 2000; Hickman et al., 1998 Robertson-Tait et al., 2004; Hickman and Davatzes, 2011; Davatzes and Hickman, 2006; Blake and Davatzes 2011; Blake and Davatzes, 2012). Based on inversion of fault kinematic data, Edwards (2013) interpreted that two discrete stress orientations are preserved at Neal Hot Springs. An older episode of east-west directed extension and a younger episode of southwest-northeast directed sinistral, oblique -normal extension. This interpretation is consistent with the evolution of Cenozoic tectonics in the region (Edwards, 2013). As such we applied a southwest-northeast (060) directed normal faulting stress regime, consistent with the younger extensional episode, to the Neal Hot Springs faults. Under these stress conditions northeast striking steeply dipping fault segments have the highest tendency to dilate and northeast striking 60 degrees dipping fault segments have the highest tendency to slip. Under these stress condi...

15 GEOTHERMAL ENERGY↗

Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

ARIES↗

The Evolution of Hot-Isostatic Pressing for the Treatment of Radioactive Wastes - 18276

Hot-isostatic Pressing (HIPing) was first developed by Battelle in the 1950's for applications in the nuclear program. The use of HIPing as a means of treating radioactive wastes was first proposed and patented in Sweden in the 1970's and subsequently gained traction in the US, where throughout the 1980's and 90's work was undertaken at Rockwell, Lawrence Livermore National Laboratory (LLNL), and Idaho National Laboratory (INL) on waste-forms for US Defense wastes. This development was coupled with front-end processing options leading to conceptual plant designs which included hot-cell layouts and costings. Industrial maturation of hot-isostatic press (HIP) technology over the last 20+ years has seen it increasingly become a candidate for treating a variety of waste streams. In this paper, we discuss HIP concepts for treating radioactive wastes, present some recent work undertaken by the authors to demonstrate the feasibility of HIPing for sludge wastes and ion exchangers, and discuss the options and technology challenges for implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fabrication of Monolithic RERTR Fuels by Hot Isostatic Pressing

The RERTR (Reduced Enrichment for Research and Test Reactors) Program is developing advanced nuclear fuels for high-power test reactors. Monolithic fuel design provides higher uranium loading than that of the traditional dispersion fuel design. Hot isostatic pressing is a promising process for low-cost batch fabrication of monolithic RERTR fuel plates for these high-power reactors. Bonding U Mo fuel foil and 6061 Al cladding by hot isostatic press bonding was successfully developed at Idaho National Laboratory. Due to the relatively high processing temperature, the interaction between fuel meat and aluminum cladding is a concern. Two different methods were employed to mitigate this effect: (1) a diffusion barrier and (2) a doping addition to the interface. Both types of fuel plates have been fabricated by hot isostatic press bonding. Preliminary results show that the direct fuel/cladding interaction during the bonding process was eliminated by introducing a thin zirconium diffusion barrier layer between the fuel and the cladding. Fuel plates were also produced and characterized with a silicon-rich interlayer between fuel and cladding. This paper reports the recent progress of this developmental effort and identifies the areas that need further attention.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hot-Casting-Assisted Liquid Additive Engineering for Efficient and Stable Perovskite Solar Cells

High-performance inorganic–organic lead halide perovskite solar cells (PSCs) are often fabricated with a liquid additive such as dimethyl sulfoxide (DMSO), which retards crystallization and reduces roughness and pinholes in the perovskite layers. However, DMSO can be trapped during perovskite film formation and induce voids and undesired reaction byproducts upon later processing steps. Here, it is shown that the amount of residual DMSO can be reduced in as-spin-coated films significantly through use of preheated substrates, or a so-called hot-casting method. Hot casting increases the perovskite film thickness given the same concentration of solutions, which allows for reducing the perovskite solution concentration. By reducing the amount of DMSO in proportion to the concentration of perovskite precursors and using hot casting, it is possible to fabricate perovskite layers with improved perovskite–substrate interfaces by suppressing the formation of byproducts, which increase trap density and accelerate degradation of the perovskite layers. The best-performing PSCs exhibit a power conversion efficiency (PCE) of 23.4% (23.0% stabilized efficiency) under simulated solar illumination. Furthermore, encapsulated devices show considerably reduced post-burn-in decay, retaining 75% and 90% of their initial and post-burn-in efficiencies after 3000 h of operation with maximum power point tracking (MPPT) under high power of ultraviolet (UV)-containing continuous light exposure.

perovskite-substrate interface↗

Detection of ligand binding hot spots on protein surfaces via fragment-based methods: application to DJ-1 and glucocerebrosidase

The identification of hot spots, i.e., binding regions that contribute substantially to the free energy of ligand binding, is a critical step for structure-based drug design. Here we present the application of two fragment-based methods to the detection of hot spots for DJ-1 and glucocerebrosidase (GCase), targets for the development of therapeutics for Parkinson's and Gaucher's diseases, respectively. While the structures of these two proteins are known, binding information is lacking. In this study we employ the experimental multiple solvent crystal structures (MSCS) method and computational fragment mapping (FTMap) to identify regions suitable for the development of pharmacological chaperones for DJ-1 and GCase. Comparison of data derived via MSCS and FTMap also shows that FTMap, a computational method for the identification of fragment binding hot spots, is an accurate and robust alternative to the performance of expensive and difficult crystallographic experiments.

36 MATERIALS SCIENCE↗

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗