Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HFIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Neutron Imaging Calibration to Measure Void Fraction

Void fraction is an intuitive parameter that describes the fraction of vapor in a two-phase flow. It appears as a key variable in most heat transfer and pressure drop correlations used to design evaporating and condensing heat exchangers, as well as determining charge inventory in refrigeration systems. Void fraction measurement is not straightforward, however, and assumptions on the invasiveness of the measuring technique must be made. Neutron radiography or neutron imaging has the potential to be a truly non-invasive void fraction measuring technique but has until recently only offered qualitative descriptions of two-phase flow, in terms of flow maldistributions, for example. This paper describes the calibration approach necessary to employ neutron imaging to measure steady-state void fraction. Experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory (ORNL), Oak Ridge, TN, USA.

42 ENGINEERING↗

The CG-1D neutron imaging beamline at the Oak Ridge National Laboratory High Flux Isotope Reactor

The Oak Ridge National Laboratory Neutron Sciences Directorate has installed a neutron imaging beamline at the High Flux Isotope Reactor (HFIR) cold guide hall. CG-1D is one of the three instruments that make up the CG1 instrument suite. The beamline optics and detector have recently been upgraded to meet the needs of the neutron imaging community (better smoothing of guide system artifacts, higher flux or spatial resolution). These upgrades comprise a new diffuser/aperture system, two new detectors, a He-filled flight tube and silicon (Si) windows. Shielding inside the flight tube, beam scrapers and a beam stop ensure that biological dose is less than 50 Sv/hr outside of the radiation boundary. A set of diffusers and apertures (pinhole geometry) has been installed at the exit of the guide system to allow motorized L/D variation. Samples sit on a translation/rotation stage for alignment and tomography purposes. Detectors for the CG-1D beamline are (1) an ANDOR DW936 charge coupled device (CCD) camera with a field of view of approximately 7 cm x 7 cm and ~ 80 microns spatial resolution and 1 frame per second time resolution, (2) a new Micro-Channel Plate (MCP) detector with a 2.8 cm x 2.8 cm field of view and 55 microns spatial resolution, and 5 s timing capability. 6LiF/ZnS scintillators of thickness varying from 50 to 200 microns are being used at this facility. An overview of the beamline upgrade and preliminary data is presented here.

Santodonato, Louis J↗

CS-Studio Scan System Parallelization

For several years, the Control System Studio (CS-Studio) Scan System has successfully automated the operation of beam lines at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and Spallation Neutron Source (SNS). As it is applied to additional beam lines, we need to support simultaneous adjustments of temperatures or motor positions. While this can be implemented via virtual motors or similar logic inside the Experimental Physics and Industrial Control System (EPICS) Input/Output Controllers (IOCs), doing so requires a priori knowledge of experimenters requirements. By adding support for the parallel control of multiple process variables (PVs) to the Scan System, we can better support ad hoc automation of experiments that benefit from such simultaneous PV adjustments.

43 PARTICLE ACCELERATORS↗

Neutron Imaging of a Two-Phase Refrigerant Flow

Void fraction remains a crucial parameter in understanding and characterizing two-phase flow. It appears as a key variable in both heat transfer and pressure drop correlations of two-phase flows, from the macro to micro- channel scale. Void fraction estimation dictates the sizing of both evaporating and condensing phase change heat exchangers, for example. In order to measure void fraction some invasive approach is necessary. Typically, visualization is achieved either downstream of the test section or on top by machining to expose the channel. Both approaches can lead to inaccuracies. The former assumes the flow will not be affected moving from the heat exchanger surface to the transparent section. The latter distorts the heat flow path. Neutron Imaging can provide a non-invasive measurement because metals such as Aluminum are essentially transparent to neutrons. Hence, if a refrigerant is selected that provides suitable neutron attenuation; steady-state void fraction measurements in two-phase flow are attainable in-situ without disturbing the fluid flow or heat flow path. Neutron Imaging has been used in the past to qualitatively describe the flow in heat exchangers in terms of maldistributions without providing void fraction data. This work is distinguished from previous efforts because the heat exchanger has been designed and the refrigerant selected to avail of neutron imaging. This work describes the experimental flow loop that enables a boiling two-phase flow; the heat exchanger test section and downstream transparent section are described. The flow loop controls the degree of subcooling and the refrigerant flowrate. Heating cartridges embedded in the test section are employed to control the heat input. Neutron-imaged steady-state void fraction measurements are captured and compared to representative high-speed videography captured at the visualization section. This allows a qualitative comparison between neutron imaged and traditional techniques. The measurements are also compared to correlations in the literature. Preliminary void fraction images from a macro-channel flow are presented, consisting of 1 channel, 4mm wide, 4mm high and 83.32mm long. Flow regime identification is examined. The experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA.

Geoghegan, Patrick J↗

Comparison of Calculated and Experimental Results for a Boiling/Condensing Experimental Facility

A new experimental facility for materials irradiation and testing at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) is being developed. Details of this facility have been presented before [1, 2]. A prototype of this facility, the Thermo-Syphon Test Loop (TSTL) has been built and experimental data have been obtained and analyzed [3, 4]. Pre-test calculations for this facility with the RELAP5-3D code [5] have been presented previously [6] as well as other calculations [7, 8] with the TRACE code [9]. The results of both codes were very different [7]. RELAP5-3D predicted much higher pressures and temperatures than TRACE. This paper compares calculated results with the TSTL experimental data.

boiling↗

TEM characterization of a simultaneously neutron-irradiated and helium-injected PM2000 ODS alloy

Transmission electron microscopy (TEM) discs of PM2000 were coated on one side with a ~4 µm thick NiAl film and irradiated in HFIR to a neutron displacement damage dose of 21.2 dpa at 500°C. The dpa are primarily produced by fast neutrons, while the in situ He injection (ISHI) to 1230 appm derives from the thermal neutron two-step 59 Ni(n,α) reaction. A uniform He injection profile extends up to about 8 µm below the NiAl coating, hence the remaining material experiences only dpa damage (21.2 dpa at 500°C). This report summarizes analytical TEM analyses to compare the two different regions, i.e., simultaneous He-injection/displacement damage versus displacement damage only, or high and very low He/dpa ratios, respectively. TEM analyses of the He implanted region reveals a high density of small (<2 nm) He bubbles predominantly associated with dislocation loops in the matrix. Because of a very large grain size, no grain or subgrain boundaries were observed in the samples prepared by focused ion beam (FIB) micromachining. The only voids formed were associated with large ODS particles, all of which were amorphous, irrespective of particle size and level of He. The ODS particles range in size from 15-30 nm, and most particles have a single faceted void attached to it that ranges in size from 5 to 15 nm. On the non-implanted side of the sample, no He bubbles could be detected, and faceted voids were found on ~10% of the ODS particles. The He-implanted side contains both <100>{100} and ½<111>{111} dislocation loops and a low density of line dislocations, whereas the un-implanted side possesses predominantly line dislocations with a lower density of dislocation loops. In both regions, nanoscale fcc precipitates exhibiting a cube-on-cube orientation relationship with the bcc matrix were observed. Chemical analysis using energy dispersive x-ray spectroscopy (EDS) indicates this phase is rich in Al and Ti. It was also noted that substantial Cr segregation occurs around the dislocation loops, concurrent with Fe depletion. The clusters of fcc precipitates that do not appear to be associated with the existing loops or line dislocations. The amorphous Y-Al-O particles contain a high Al concentration (>20 at%) and Cr segregation/Fe-depletion at the periphery.

Jung, Hee Joon↗

Overview of the Neutron Radiography and Computed Tomography at the Oak Ridge National Laboratory and Applications

The Oak Ridge National Laboratory (ORNL) Neutron Sciences Directorate (NScD) has installed a neutron imaging (NI) beam line at the High Flux Isotope Reactor (HFIR) cold guide hall. The CG-1D beam line produces cold neutrons for a broad range of user research spanning from engineering to material research, additive manufacturing, vehicle technologies, archaeology, biology, and plant physiology. Recent efforts have focused on increasing flux and spatial resolution. A series of selected engineering applications is presented here. Historically and for more than four decades, neutron imaging (NI) facilities have been installed exclusively at continuous (i.e. reactor-based) neutron sources rather than at pulsed sources. This is mainly due to (1) the limited number of accelerator-based facilities and therefore the fierce competition for beam lines with neutron scattering instruments, (2) the limited flux available at accelerator-based neutron sources and finally, (3) the lack of high efficiency imaging detector technology capable of time-stamping pulsed neutrons with sufficient time resolution. Recently completed high flux pulsed proton-driven neutron sources such as the ORNL Spallation Neutron Source (SNS) at ORNL and the Japanese Spallation Neutron Source (JSNS) of the Japan Proton Accelerator Research Complex (J-PARC) in Japan produce high neutron fluxes that offer new and unique opportunities for NI techniques. Pulsed-based neutron imaging facilities RADEN and IMAT are currently being built at J-PARC and the Rutherford National Laboratory in the U.K., respectively. ORNL is building a pulsed neutron imaging beam line called VENUS to respond to the U.S. based scientific community. A team composed of engineers, scientists and designers has developed a conceptual design of the future VENUS imaging instrument at the SNS.

additive manufacturing↗

US Progress on Property Characterization to Support LEU U-10 Mo Monolithic Fuel Development

The US High Performance Research Reactor program is pursuing development and qualification of a new high density monolithic LEU fuel to facilitate conversion of five higher power research reactors located in the US (ATR, HFIR, NBSR, MIT and MURR). In order to support fabrication development and fuel performance evaluations, new testing capabilities are being developed to evaluate the properties of fuel specimens. Residual stress and fuel-cladding bond strength are two characteristics related to fuel performance that are being investigated. In this overview, new measurement capabilities being developed to assess these characteristics in both fresh and irradiated fuel are described. Progress on fresh fuel testing is summarized and on-going hot-cell implementation efforts to support future PIE campaigns are detailed. It is anticipated that benchmarking of as-fabricated fuel characteristics will be critical to establishing technical bases for specifications that optimize fuel fabrication and ensure acceptable in-reactor fuel performance.

Characterization↗

Failure, modal, and vibration analysis of a reactor pool cooling pump

Two 75 HP pumps redundantly supply cooling water to the reactor pool of the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). Due to a recent history of premature bearing failures, one of these pumps has undergone maintenance to deal with possible issues of misalignment and base looseness. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up and down order tracking, and modal impact have been utilized to verify the effectiveness of the maintenance and identify possible remaining failure modes. The studies conclude that the pump is, after the maintenance, in an overall good conditional state as per ISO 10816, but a few failure modes remain. These modes consist of some shaft unbalance, considerable shaft misalignment intensified by piping movement, possible motor ground fault, hydrodynamic issues such as cavitation with modal interaction, and base looseness. These failure modes and their supporting data have been used to make suggestions for future maintenance, to verify the effectiveness of the previous maintenance, and to provide a base on which to check future data. This report will cover the testing setup, methodology, analysis results, and maintenance suggestions.

42 ENGINEERING↗

A Versatile Coupled Test Reactor Concept

A Versatile Coupled Test Reactor (VCTR) is a highly reconfigurable, sodium-cooled, coupled fast and thermal spectrum test reactor, which provides (1) a fast flux irradiation environment prototypical of potential fast reactor designs, (2) thermal and epithermal flux irradiation environments complementary to those of ATR and HFIR, and (3) other possibilities, including beam tubes for scientific experiments, irradiation vehicles for isotope production, etc. The ongoing design of a new versatile coupled thermal-fast test reactor at INL that can accommodate both fast and thermal irradiation, technology and safety features tests is described in this paper. A coupled reactor is defined as a reactor with two distinct spectral zones (Fast and Thermal), which are neutronically coupled to each other: some neutrons born in zone F cause fission in zone T and vice-versa. Only fast neutrons are allowed to go from one zone to the other, which is assured by a thermal neutron filter. A distinction of coupling can be made depending on the main purpose of using fuel assemblies with some level of neutron moderation (thermal zone) together with fuel assemblies with as little moderation as possible (fast zone). It can be used mainly to minimize the core power and fissile inventory, or it can be used mainly to provide additional control of the irradiation conditions in the thermal zone. The steady-state neutronics calculations were performed using the three-dimensional continuous-energy Monte Carlo reactor physics burnup calculation code Serpent2. Although, a few changes were necessary to support the Serpent code in calculating the coupling coefficients. Steady state and transient thermal analyses were performed with RELAP5-3D. RELAP5-3D is the latest in the RELAP5 code series developed at INL. One of the core configurations using only low enriched uranium fuel could provide both a high fast neutron flux and a high thermal neutron flux—respectively 3.5E15 n/s.cm2 and 1E15 n/s.cm2—in large volumes while maintaining core power below 300 MW. The use of plutonium in the fast zone provides more flexibility in fuel assembly design than when low enriched uranium is used, the designer has more degrees of freedom to work with; in particular it could provide additional control of the irradiation conditions in the thermal zone. The results showed that the current design fulfills most R&D needs requirements providing high thermal and fast fluxes and wide possibilities for diversified future reactor features test in appropriate loops, both in steady state and during transients.

coupled spectrum↗

ADVANCED TEST REACTOR (ATR) CONVERSION TO LOW ENRICHED URANIUM (LEU) FUEL

The United States Department of Energy (DOE), National Nuclear Security Administration (NNSA), Office of Material Management and Minimization (MMM) is working to convert research reactors globally from highly enriched uranium (HEU) fuel to low-enriched uranium (LEU) fuel. MMM and its predecessor programs have converted or verified the shutdown of 88 HEU research reactors and isotope production facilities, using LEU fuel developed in the 1980s. However, there is a small set of high performance research reactors which require a new high density LEU fuel for conversion, including six U.S. high performance research reactors (USHPRRs), which include the Advanced Test Reactor (ATR) and the ATR Critical (ATRC) Facility at the Idaho National Laboratory (INL) near Idaho Falls, ID; University of Missouri Research Reactor (MURR) at Columbia, MO; Massachusetts Institute of Technology Reactor (MITR) at MIT in Cambridge, MA; High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) near Oak Ridge, TN; and National Bureau of Standards Reactor (NBSR) at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) in Gaithersburg, MA. These reactors will share the same uranium-molybdenum (U-Mo) fuel plate design. The U-Mo fuel meat foil will have a zirconium (Zr) diffusion barrier with aluminum cladding. Three different application methods for the Zr diffusion barrier layer are being pursued – co-rolled, electroplating and plasma spraying. Fabrication of the higher density LEU U-Mo fuel has presented several challenges. Because the U-Mo fuel fabrication process uses the existing stockpile of 93% highly enriched uranium (HEU) to be blended with molybdenum and depleted uranium (DU) to form 19.75% LEU, cost benefits of enriching to 19.75% will not be realized. Homogeneity of the U-235 and molybdenum in the metal foil is a challenge due to U-Mo casting process results in variations between adjacent cast U-Mo plates. LEU will not require less U-235 as previously believed due to self-shielding properties of U-238 requiring additional U-235 to be loaded in each fuel element. Although the overall dimensions of the ATR fuel element remain unchanged, the weight of the LEU ATR fuel element is 72% greater than a HEU ATR fuel element. During waste recovery and recycling efforts, separation of aluminum cladding from the HEU fuel meat is a relatively simple chemical dissolution, however, separation of the Zr diffusion barrier from the U-Mo fuel meat is significantly more challenging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Residual Stress Mapping of Repaired Spent Nuclear Fuel Welded Stainless-Steel Canisters

Stress corrosion cracking (SCC) caused by atmospheric deposition and deliquescence of aggressive compounds such as chloride-containing salts or oxidized sulfur species may pose a potential issue to the extended service life of spent nuclear fuel (SNF) storage canisters. When a chemically susceptible material is exposed to a hostile environment (e.g., coastal salt air) for a sufficient length of time, SCC may occur at locations on the canister which have undergone high tensile residual stress. These locations are often found in weld zones and the heat-affected zones (HAZ) of welded joints. Ideally, these cracks could be repaired by traditional fusion welding techniques, but the highly localized heat input of the repair welding may introduce additional high tensile residual stress and could increase the risk for future SCCs. This paper presents the results of neutron residual stress mapping of as-welded and repaired stainless steel specimens. The as-welded specimens were provided by Sandia National Laboratories from a canister mock-up manufactured using procedures similar to those used for actual canister production. ASME-qualified gas-tungsten arc welding (GTAW) was used to repair the specimens, and post-repair residual stresses were measured using neutron diffraction at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR). As-welded and repaired specimen residual stress distributions are evaluated and compared.

Chatzidakis, Stylianos↗

Novel Low-Cost Approach for Acquiring High Resolution High-Speed Data

The Oak Ridge National Laboratory (ORNL) has developed and tested a novel system architecture for acquiring high fidelity high-speed data. The approach uses a low-cost consumer grade audio recording device coupled with computing technology running open-source software. The main advantage of this approach is perchannel cost; an instrument grade data acquisition system typically costs between $800 to $2,000 per channel compared to less than $50 per channel for these consumer grade components. Three systems, each featuring four channels, have been deployed for acquiring data from geophones and the electrical supply system that supports the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC) at ORNL. Each channel samples at 96 kHz at 24-bit resolution. The deployed systems operate continuously 24/7 and produce about 4 terabytes of data per month per system. This paper provides a technical overview of this approach, its implementation, and some preliminary results from qualification testing. This work was conducted in support of the Multi-Informatics for Nuclear Operations Scenarios (MINOS).

Wetherington Jr, G↗

Deployment of magnetometers to monitor stray magnetic fields near the PROSPECT detector

PROSPECT is a reactor antineutrino experiment located in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. PROSPECT’s primary goals are to probe short-baseline oscillations and perform a precise measurement of the U-235 reactor antineutrino spectrum. The detector consists of 154 segmented cells filled with 6Li-doped liquid scintillator. Each segment holds two PMTs, one on each end of the cell. The PMTs can be exposed to stray magnetic fields from superconducting magnets operating on the experiment hall one floor below the detector. The monitoring of the magnetic fields is an important part of our background characterization as the magnetic fields can directly influence the energy measurement. This study presents the characterization and monitoring of stray magnetic fields using triple axis magnetometers near the detector.

Gilbert, Corey E.↗

Imaging Based Detector with Efficient Scintillators for Neutron Diffraction Measurements

The Anger Camera developed by the detector group at the Oak Ridge National Laboratory was utilized for the present work for its unique advantage of employing multiple modules to obtain large active measurement area for detecting diffracted/scattered thermal neutrons. Considering the relatively small flux associated with diffracted/scattered neutrons, suitable efficiency with high spatial resolution is a requirement for utilizing two-dimensional imaging detectors. The potential to implement pulse shape (in addition to pulse height) discrimination-based scintillators further enhances the ability to detect diffracted neutrons with improved signal to noise ratio. In this paper, initial results associated with 6Li glass-based scintillator will be presented. The authors explored the feasibility of using this system to detect and quantify diffraction peaks and peak shifts at the Neutron Residual Stress Facility (NRSF2), High Flux Isotope Reactor (HFIR) in the Oak Ridge National Laboratory (ORNL). Suitable camera mounting and shielding had to be developed. Reference measurements using polycrystalline powders with known atomic planar spacing will be discussed along with measurement settings associated with expected resolution for peak shift measurements. Initial results are promising and demonstrate that a suitable scintillation-based neutron detecting system is viable for residual stress-based diffraction measurements. Small area detectors are also feasible with suitable consideration to scattering volume and distance to detector.

Seals, Matthew↗

Diagnostic Use of Neutron-Sensitive Image Plates at ORNL Neutron Facilities

Neutron facilities at the ORNL provide a versatile suite of instruments to the neutron scattering community. Neutron-sensitive imaging plates are useful when characterizing neutron beamlines at the SNS and HFIR facilities. We describe a number of characterization, commissioning, and troubleshooting measurements in which we use neutron-sensitive image plates to better understand and improve instrument performance. We have used image plates to characterize neutron beams in many ways: to determine absolute beam size, assess transverse beam distribution, and to measure absolute intensity. During the initial radiation survey of the new US/Japan Cold Triple Axis instrument (CTAX), images of the beam footprint were taken multiple monochromator assembly angles. Images of the CTAX beam footprint showed a secondary beam spot, indicating a misalignment in the monochromator. Measurements at the Fine-Resolution Fermi Chopper Spectrometer (SEQUOIA) instrument for 400, 300, 250 and 120meV provide beam size and relative intensity. We frequently use image plates to verify sample alignment within a neutron beam prior to data acquisition. Finally, we measured the absolute intensity across a very large (20cm by 30cm) mono- chromatic beam with a combination of image plates and a conventional beam monitor on the Fundamental Physics beam line. While there are limitations to the data obtained from image plates, especially on pulsed sources, when combined with other tools, they can provide more depth to beamline analysis and development.

Geoghegan, Ceris↗

Radioactivity Calculator for Research and Test Reactor Neutron-Activated Materials

The Idaho National Laboratory (INL) Nuclear Science User Facility (NSUF) supports nuclear energy-relevant research into the effects of radiation on nuclear fuels and structural materials. The NSUF provides access, at no cost to the researcher, to the Advanced Test Reactor (ATR), the High-Flux Isotope Reactor (HFIR), and other university and national laboratory research and test reactors for radiation effects experiments. Post-irradiation examination of materials poses some difficulties when studying neutron-irradiated materials due to the radioactivity levels of the materials. Inside a test reactor, under high neutron flux, stable materials can activate (capture a neutron) and become unstable or radioactive. These newly created radioactive materials decay, based on their respective half-lives, and emit energetic radiation. Nuclides with short half-lives are able to decay to sufficiently low radiation levels prior to the sample being removed from the reactor. However, nuclides with longer half-lives present a challenge since they must be handled with extreme caution and stored until their radioactivity levels decrease. If immediate examination is required, the examination may take place in a hot cell, which can dramatically increase the cost of the project. The NSUF has access to a variety of hot cells and characterization capabilities at national laboratories, universities, and industrial sites across the United States. In order to estimate the post-irradiation radioactivity levels of materials early in the experiment cycle, we created a radioactivity calculator, hosted on the NSUF web site (nsuf.inl.gov), which will consider three stages of neutron activations and decays for sample materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coordination of Plutonium Separations

NASA and the Department of Energy (DOE) are currently working together to reestablish a 238Pu supply capability using DOE's existing facilities and reactors. The effort is being led by Oak Ridge National Laboratory (ORNL). Target rods, containing neptunium oxide (NpO2), are fabricated at ORNL and irradiated in the ORNL High Flux Isotope Reactor (HFIR) currently and soon will be irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Irradiated targets are processed in hot cells at the ORNL Radiochemical Engineering Center to recover the plutonium (Pu) product and unconverted neptunium (Np) for recycle. The 238PuO2 product is shipped to Los Alamos National Laboratory (LANL) for fabrication of heat source pellets. Key activities, such as the transport of the neptunium to ORNL, irradiation of neptunium, and chemical processing to recover the newly generated 238Pu, have been demonstrated with the initial amounts of ~100 g heat-source plutonium oxide (HS PuO2) produced. Product samples have been shipped to LANL for evaluation, including chemical impurity analysis. This paper will examine the status of producing new 238Pu from irradiated targets.

Wham, Robert↗