TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Observation of Cosmic Gamma Ray Bursts in the Experiments Onboard Lomonosov and Vernov Satellites

The study of cosmic gamma ray bursts (GRBs) is one of the main goals of the Lomonosov space mission. The main advantage of this mission is simultaneous multiwavelength observations of GRBs covering the optical, X-ray and gamma-ray ranges. The mission payload includes the GRB monitor BDRG, wide-field optical cameras SHOK, and the UFFO instrument. Data are recorded mainly by the event trigger provided by the BDRG instrument, which measures the spectral and temporal properties of the burst in the energy range 10–3000 keV. The BDRG instrument also provides estimation of the source coordinates by comparing the readings of three differently directed detectors with an accuracy of several degrees. Wide-field SHOK optical cameras have a field of view of ~20° × 40°. They fix a set of images with a frequency of about five frames per second prior to the trigger and another set immediately after the trigger. The UFFO instrument includes the UBAT telescope with a coded mask for measurements in hard X-ray and soft gamma-ray ranges and an optical telescope with a slewing mirror (SMT) that can be directed on the GRB source for a time ~1 s for measuring GRB prompt emission in the early stages. In response to an BDRG trigger signal, the real-time data on a detected GRB are transmitted to the Earth via Globalstar network to the Gamma-ray Coordinates Network (GCN) and ground-based observatories. During observations on the Lomonosov satellite, 20 gamma-ray bursts were detected and catalogued. Several gamma-ray bursts were also detected in the Vernov satellite experiment. An example of such an event is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MODELING THE GAMMA-RAY EMISSION IN THE GALACTIC CENTER WITH A FADING COSMIC-RAY ACCELERATOR

Recent HESS observations of the ∼200 pc scale diffuse gamma-ray emission from the central molecular zone (CMZ) suggest the presence of a PeV cosmic-ray accelerator (PeVatron) located in the inner 10 pc region of the Galactic center. Interestingly, the gamma-ray spectrum of the point-like source (HESS J1745-290) in the Galactic center shows a cutoff at ∼10 TeV, implying a cutoff around 100 TeV in the cosmic-ray proton spectrum. Here we propose that the gamma-ray emission from the inner and the outer regions may be explained self-consistently by run-away protons from a single yet fading accelerator. In this model, gamma-rays from the CMZ region are produced by protons injected in the past, while gamma-rays from the inner region are produced by protons injected more recently. We suggest that the blast wave formed in a tidal disruption event (TDE) caused by the supermassive black hole (Sgr A*) could serve as such a fading accelerator. With typical parameters of the TDE blast wave, gamma-ray spectra of both the CMZ region and HESS J1745-290 can be reproduced simultaneously. Meanwhile, we find that the cosmic-ray energy density profile in the CMZ region may also be reproduced in the fading accelerator model when appropriate combinations of the particle injection history and the diffusion coefficient of cosmic rays are adopted.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification and Quantification of Beta-Emitters in Waste Packages by Segmented Gamma-Scanning - 20114

A commonly applied method for the non-destructive characterization of the radioactive inventory of waste packages (e.g. 200-l drums) is segmented gamma-scanning. The gamma-emitting inventory is identified via their characteristic lines in the measured spectra. The corresponding net peak areas allow for quantification applying appropriate models. The identification and quantification of beta-emitters present in the waste package require further evaluation. While some of them emit gamma-rays, too, which can be used for identification and quantification, pure beta-emitters contribute to the gamma-spectra only by their Bremsstrahlung-spectra. {sup 32}P, {sup 90}Sr and {sup 90}Y are typical representatives of these isotopes. A method is developed for identification and quantification of these pure beta-emitters in radioactive waste packages. Origin of the procedure is the evaluation of the measured gamma-spectrum. After the identification of all lines present in the spectrum (characteristic gamma-lines, single- and double-escape-lines, X-ray-lines, annihilation peak etc.) this information is used together with calibration data of the detection system and further a-priori information like matrix composition, cross-section data from databases etc. to simulate the spectra without the Bremsstrahlung-components by an appropriate method. This may be Monte Carlo simulations or, like in our case, a computer code taking into account mathematical descriptions of the physical effects like photo effect, (multiple) Compton scattering, backscattering etc. and the attenuation effects of the waste matrix. In any case, the resulting spectrum must simulate the real spectrum without its Bremsstrahlung-component as good as possible. Subtracting the simulated from the measured spectrum then results in the Bremsstrahlung-components caused by the beta-emitters. Prior to evaluation, a set of Bremsstrahlung-spectra is calculated and stored for different beta-emitters in different matrices using the Bethe-Heitler equation. This data set can be extended for new conditions, if necessary, and is allocated in a data base for future application. Applying a non-linear optimization using the generalized reduced gradient method for comparing the calculated with the derived Bremsstrahlung-spectra results in the identification of the beta-emitter and a factor, which is proportional to its activity. The proportionality is determined by previous calibration measurements. The application of the method is demonstrated by measurements on a 200-l mock-up drum and a real waste package. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

An investigation of {sup 60}Co gamma radiation-induced effects on the properties of nanostructured α-MoO{sub 3} for the application in optoelectronic and photonic devices

Gamma ray has sufficient energy to ionize and displace of atoms when interacts with optoelectronic and photonic devices that are placed at γ-radiation exposure environment, can be exposed to gamma radiation, resulting the alteration of the physical properties and hence the performances of devices. A comprehensive investigation of physical properties of the semiconductor materials under the influence of gamma radiation is essential for the effective design of devices for the application in the radiation exposure environment. In this article, a potential candidate for optoelectronic and photonic devices, orthorhombic MoO{sub 3} nanoparticles with average crystallite size of 135.31 nm successfully synthesized by hydrothermal method. Then, the properties of nanoparticles exposed to low (10 kGy) and high (120 kGy) absorbed dose of γ-rays from {sup 60}Co source were characterized by XRD, FESEM, FTIR and UV–Vis–NIR spectrophotometer and effects of absorbed doses was investigated for the first time. A significant change is observed in different physical properties of α-MoO{sub 3} nanoparticles after gamma exposure. The XRD patterns reveal the average crystallite size, intensity and the degree of crystallinity decrease for low dose (10 kGy) and increases for high dose (120 kGy). The calculated average crystallite size exposed to low and high doses are 127.79 nm and 136 nm, respectively. The lattice strain and dislocation density, however, shows the opposite trend of crystallite size with absorbed doses. This result is good evidence for the deterioration of crystallinity for low dose and improvement for high dose. The FESEM results reveal the significant effects of gamma doses on the micrographs of layered structure and on grain size. The optical studies disclose that band gap increases gradually from 2.78 to 2.90 eV, this behavior is associated with the reduction of electronic localized states. These results suggest that α-MoO{sub 3} nanoparticles could tolerate high doses of gamma radiation, making it a promising candidate for optoelectronic and photonic devices for γ-ray exposure environment applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study of electronic transport in gamma ray exposed nanowires

Graphical abstract: A sharp decline in the I–V characteristics of Cu (and Cd) nanowires was experimentally observed after the gamma ray exposure of nanowires. Irradiation induced transformations in the granular properties and the resonance state of electron–phonon coupling beyond a particular value of external field may be accountable for observed shape of I–V characteristics in gamma ray exposed nanowires. - Highlights: • Cu and Cd nanowires were synthesized by technique of electrodeposition in templates. • The nanowires were exposed to different doses of gamma ray photons. • A sharp decline in the current in I–V characteristics (IVC) was observed. • Structural deviation in terms of granular orientations was also analysed. • The electron–phonon coupling may be responsible for observed sharp decline in IVC. - Abstract: One dimensional nanostructures provide the most restricted and narrow channel for the transport of charge carriers and therefore 1D structures preserve their significance from the viewpoint of electronic devices. The net radiation effect on nanomaterials is expected to be more (due to their increased reactivity and lesser bulk volume) than their bulk counterparts. Radiation often modifies the structure and simultaneously the other physical properties of materials. In this manner, the irradiation phenomenon could be counted as a strong criterion to induce changes in the structural and electrical properties of nanowires. We have studied the effect of gamma rays on the electronic flow through Cu and Cd nanowires by plotting their I–V characteristics (IVC). The IVC of gamma ray exposed nanowires was found to be a combination of the linear and nonlinear regions and a decreasing pattern in the electrical conductivity (calculated from the linear portion of IVC) was observed as we increased the dose of gamma rays.

36 MATERIALS SCIENCE↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An upper limit on the cosmic-ray luminosity of individual sources from gamma-ray observations

Different types of extragalactic objects are known to produce TeV gamma-rays. Some of these objects are the most probable candidates to accelerate cosmic rays up to 10{sup 20} eV. It is very well known that gamma-rays can be produced as a result of the cosmic ray propagation through the intergalactic medium. These gamma-rays contribute to the total flux observed in the direction of the source. In this paper we propose a new method to derive an upper limit on the cosmic-ray luminosity of an individual source based on the measured upper limit on the integral flux of GeV-TeV gamma-rays. We show how it is possible to calculate an upper limit on the cosmic-ray luminosity of a particular source and we explore the parameter space in which the current GeV-TeV gamma-ray measurements can offer a useful determination. We study in detail two particular sources, Pictor A and NGC 7469, and we calculate the upper limit on the proton luminosity of each source based on the upper limit on the integral gamma-ray flux measured by the H.E.S.S. telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

$\gamma$-to-neutron branching ratio for deuterium-tritium fusion determined using high-energy-density plasmas and a fused silica Cherenkov detector

A fused silica Cherenkov detector was used to measure deuterium-tritium (DT) gammas during a set of 52 direct-drive cryogenic experiments performed at OMEGA. The detector was calibrated using the 4.4 MeV$\gamma$ from the first-excited state of carbon, which is produced when 14-MeV DT neutrons impinge upon a carbon puck. An approximate DT $\gamma$ spectrum as well as neutron yields from a standard neutron time-of-flight detector at OMEGA were used to calculate a DT $\gamma$-to-neutron branching ratio of (8.42 ± 2.84 ) x 10 -5 . Assuming an excited-state to ground-state ratio of 2.1:1, the measurement detailed in this work results in an approximate ground state only$\gamma$-to-neutron branching ratio of 2.72 x 10 -5 . So, this value is somewhat lower than accelerator-based measurements of the ground-state DT $\gamma$ only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron and gamma sensitivities of self-powered detectors: Monte Carlo modelling

This paper deals with the development of a detailed Monte Carlo approach for the calculation of the absolute neutron sensitivity of SPNDs, which makes use of the MCNP code. We will explain the calculation approach, including the activation and beta emission steps, the gamma-electron interactions, the charge deposition in the various detector parts and the effect of the space charge field in the insulator. The model can also be applied for the calculation of the gamma sensitivity of self-powered detectors and for the radiation-induced currents in signal cables. The model yields detailed information on the various contributions to the sensor currents, with distinct response times. Results for the neutron sensitivity of various types of SPNDs are in excellent agreement with experimental data obtained at the BR2 research reactor. For typical neutron to gamma flux ratios, the calculated gamma induced SPND currents are significantly lower than the neutron induced currents. The gamma sensitivity depends very strongly upon the immediate detector surroundings and on the gamma spectrum. Our calculation method opens the way to a reliable on-line determination of the absolute in-pile thermal neutron flux. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers

The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of multipixel photon counters from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at the Brookhaven National Laboratory and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10 8 to 10 12 n/cm 2 . The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This paper was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time Free-moving Active Coded Mask 3D Gamma-Ray Imaging

The ability to localize and map the distribution of gamma-ray emitting radionuclides in 3D has applications ranging from medical imaging to nuclear security. In the case of radiological source search and nuclear contamination remediation, the deployment of freely moving detection systems such as hand- held instruments or ground/aerial-based vehicles are critical in overcoming the inverse square law and complex shielding scenarios. Using contextual sensors, these systems can simultaneously generate 3D maps of the surrounding environment and track the position and orientation of the gamma-ray sensitive detectors in that environment. The fusion of contextual scene data and gamma-ray detector data to facilitate real-time 3D gamma-ray image reconstruction has been demonstrated with mobile HPGe and CdZnTe-based Compton cameras for gamma-ray energies ranging from a few hundred keV to several MeV. Here we apply this approach for lower energy (50-400 keV) gamma-rays, using a hand-held CdZnTe-based omnidirectional imaging system and an active coded mask imaging modality. Here, we present our approach to real-time reconstruction using a scene data constrained GPU- accelerated list-mode MLEM algorithm and show results from several measurements in the lab and in the field.

3D gamma-ray imaging↗

Performance simulation of the soft gamma-ray concentrator

The soft gamma-ray concentrator is a telescope mission concept utilizing a suitable arrangement of bent multilayer structures of alternating low- and high-density materials. This lens is able to channel gamma-ray photons via total external reflection and concentrate the incident radiation to a point. The channeling technique offers the potential for concentrating gamma rays with focal lengths <10 m and energies >100 keV, beyond the reach of current grazing-incidence hard x-ray mirrors. For the performance estimation of such an instrument, we have developed a flexible set of computer modeling tools to compute the optical properties of multilayer structures, predict the channeling efficiency for a given multilayer configuration, and aid in the optimization of potential gamma-ray concentrator-based telescope designs. This modeling includes the multilayer optical properties calculated by the IMD software, the ray tracing using an IDL code, and the focal plane detector simulation by MEGAlib. We illustrate the potential of this approach by presenting simulated astronomical observations from a balloon-borne platform. The final result, including simulated effective area, instrument sensitivity, and polarization performance, shows that the gamma-ray concentrator will provide greatly increased sensitivity for next-generation soft gamma-ray missions with modest cost and complexity.

47 OTHER INSTRUMENTATION↗

WE-D-BRF-03: Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector

Purpose: To present an experimental study of a novel range verification method for scanned and scattered proton beams. Methods: A detection system consisting of an actively shielded lanthanum(III)bromide scintillator and a one-sided lead collimator was used to measure prompt gamma-rays emitted during the delivery of proton beams to a water phantom and an anthropomorphic head phantom. The residual proton range at the collimator position was determined by comparing gamma-ray intensities while the proton energy was modulated to the distal end of the target. We used a clinical field to deliver a 50 cGy dose to a 12 cm diameter target in the water phantom and to a 175 cc tumor-shaped target in the head phantom. The detector signals were acquired with a custom data acquisition system enabling energy and time-of-flight discrimination of prompt gamma-rays. Results: Range deviations were detected with a statistical accuracy of ± 0.2 mm and ± 1.4 mm at 90% confidence level, respectively for the water and head phantom. We obtained a time resolution of 1 ns FWHM and an energy resolution < 2% FWHM for the main gamma lines from proton-induced nuclear reactions with carbon and oxygen. This allowed for an accurate separation of the prompt gamma-rays from neutron-induced background. Conclusion: Proton range deviations can be detected with millimeter accuracy using a single prompt gamma-ray measurement point acquired during the delivery of a few proton energy layers to the distal part of the target. The method is also feasible in the presence of background radiation from passively scattered proton beam delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-E-06: Teaching About the Gamma Camera and Ultrasound Imaging

Purpose: Instructional modules on applications of physics in medicine are being developed. The target audience consists of students who have had an introductory undergraduate physics course. This presentation will concentrate on an active learning approach to teach the principles of the gamma camera. There will also be a description of an apparatus to teach ultrasound imaging. Methods: Since a real gamma camera is not feasible in the undergraduate classroom, we have developed two types of optical apparatus that teach the main principles. To understand the collimator, LEDS mimic gamma emitters in the body, and the photons pass through an array of tubes. The distance, spacing, diameter, and length of the tubes can be varied to understand the effect upon the resolution of the image. To determine the positions of the gamma emitters, a second apparatus uses a movable green laser, fluorescent plastic in lieu of the scintillation crystal, acrylic rods that mimic the PMTs, and a photodetector to measure the intensity. The position of the laser is calculated with a centroid algorithm.To teach the principles of ultrasound imaging, we are using the sound head and pulser box of an educational product, variable gain amplifier, rotation table, digital oscilloscope, Matlab software, and phantoms. Results: Gamma camera curriculum materials have been implemented in the classroom at Loyola in 2014 and 2015. Written work shows good knowledge retention and a more complete understanding of the material. Preliminary ultrasound imaging materials were run in 2015. Conclusion: Active learning methods add another dimension to descriptions in textbooks and are effective in keeping the students engaged during class time. The teaching apparatus for the gamma camera and ultrasound imaging can be expanded to include more cases, and could potentially improve students’ understanding of artifacts and distortions in the images.

60 APPLIED LIFE SCIENCES↗

SU-F-J-189: A Method to Improve the Spatial Resolution of Prompt Gamma Based Compton Imaging for Proton Range Verification

Purpose: To test two new techniques, the distance-of-closest approach (DCA) and Compton line (CL) filters, developed as a means of improving the spatial resolution of Compton camera (CC) imaging. Methods: Gammas emitted from {sup 22}Na, {sup 137}Cs, and {sup 60}Co point sources were measured with a prototype 3-stage CC. The energy deposited and position of each interaction in each stage were recorded and used to calculate a “cone-of-origin” for each gamma that scattered twice in the CC. A DCA filter was developed which finds the shortest distance from the gamma’s cone-of-origin surface to the location of the gamma source. The DCA filter was applied to the data to determine the initial energy of the gamma and to remove “bad” interactions that only contribute noise to the image. Additionally, a CL filter, which removes gamma events that do not follow the theoretical predictions of the Compton scatter equation, was used to further remove “bad” interactions from the measured data. Then images were reconstructed with raw, unfiltered data, DCA filtered data, and DCA+CL filtered data and the achievable image resolution of each dataset was compared. Results: Spatial resolutions of ∼2 mm, and better than 2 mm, were achievable with the DCA and DCA+CL filtered data, respectively, compared to > 5 mm for the raw, unfiltered data. Conclusion: In many special cases in medical imaging where information about the source position may be known, such as proton radiotherapy range verification, the application of the DCA and CL filters can result in considerable improvements in the achievable spatial resolutions of Compton imaging.

60 APPLIED LIFE SCIENCES↗