Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow battery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of Communication Issues in Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS): Preprint

With the increasing adoption of distributed energy resources (DERs) in distribution networks, DERMS is becoming an attractive option to coordinate the control of DERs, especially primal-dual-based DERMS which is a well-developed class of them. In order to help lower the uncertainty in commercializing them, we evaluate and find the upper limits of severity for some common issues that can occur within the communication systems on which a primal-dual-based DERMS relies on; these include packet losses, link failures, and delays. This information can help a DERMS operator decide on the specifications for the communication infrastructure it will invest in for the DERMS. Our evaluation is based on numerical simulations of a real-world feeder with around 2,000 nodes and a DERMS that controls 163 PV generators and 140 energy storage batteries. In general, we found that the DERMS becomes less resistant to communication issues as the information flows closer to the DERs implementing the controllable power injections.

communication delay↗

Regenerative Solid Interfaces Enhance High-Performance All- Solid-State Lithium Batteries

All-solid-state Lithium batteries (ASSLBs) have gained widespread attention in recent years. However, their performance is still largely limited by the poor transport properties and stability of the solid-solid interfaces (SSIs). In this study, we report a new strategy for creating a reversible interface with good conductivity and self-adaptive mechanical properties for high-performance all-solid-state lithium batteries (ASSLBs). The interface is formed in situ from nanosized lithium iodide (LiI), a component of the solid-state electrolyte (SSE), which flows plastically along the SSE interfaces under high pressure due to its high ductility. Moreover, LiI segregates and enriches along the Li/SSE interfaces, reversibly enhancing Li plating/stripping due to its lithophilicity and high ionic conductivity. This dynamic LiI interface enables stable operation of metallic Li anode (>1000 h) at high current densities and elevated temperatures, and long-term cycling of all-solid-state Li-sulfur batteries (>250 cycles) with high sulfur utilization rate (>1400 mAh g-1) and areal capacity (>2 mAh cm-2). This study reveals a unique role of LiI in building robust SSIs and provides new insights into the design of novel SSEs and interfaces for high-performance ASSLBs.

Yu, Zhaoxin↗

Process design tools and techno-economic analysis for capacitive deionization

Capacitive deionization (CDI) devices use cyclical electrosorption on porous electrode surfaces to achieve water desalination. Process modeling and design of CDI systems requires accurate treatment of the coupling among input electrical forcing, input flow rates, and system responses including salt removal dynamics, water recovery, energy storage, and dissipation. Techno-economic analyses of CDI further require a method to calculate and compare between a produced commodity (e.g. desalted water) versus capital and operational costs of the system. In this work, we demonstrate a new modeling and analysis tool for CDI developed as an installable Matlab program that allows direct numerical simulation of CDI dynamics and calculation of key performance and cost parameters. The program is provided for free and is used to run open-source Simulink models. The Simulink environment sends information to the program and allows for a drag and drop design space where users can connect CDI cells to relevant periphery blocks such as grid energy, battery, solar panel, waste disposal, and maintenance/labor cost streams. The program allows for simulation of arbitrary current forcing and arbitrary flow rate forcing of one or more CDI cells. We employ validated well-mixed reactor formulations together with a non-linear circuit model formulation that can accommodate a variety of electric double layer sub-models (e.g. for charge efficiency). The program includes a graphical user interface (GUI) to specify CDI plant parameters, specify operating conditions, run individual tests or parameter batch-mode simulations, and plot relevant results. The techno-economic models convert among dimensional streams of species (e.g. feed, desalted water, and brine), energy, and cost and enable a variety of economic estimates including levelized water costs.

42 ENGINEERING↗

Circuit with a Switch for Charging a Battery in a Battery Capacitor Circuit

A circuit for charging a battery combined with a capacitor includes a power supply adapted to be connected to the capacitor, and the battery. The circuit includes an electronic switch connected to the power supply. The electronic switch is responsive to switch between a conducting state to allow current and a non-conducting state to prevent current flow. The circuit includes a control device connected to the switch and is operable to generate a control signal to continuously switch the electronic switch between the conducting and non-conducting states to charge the battery.

Stuart, Thomas A.↗

A Computational Framework for Energy Storage Participation in Transmission Planning with Electricity Market Participation

Energy storage technologies—including pumped storage hydropower (PSH), batteries, and other technologies—have been technically proven to be capable of providing transmission services by regulating power flows and providing voltage support. These technologies will potentially increase the flexibility of transmission infrastructure and may defer (or eliminate) the need for transmission upgrades or new investments. On the regulatory side, Congress and the Federal Energy Regulatory Commission (FERC) have issued several orders over decades that have established energy storage’s (ES) eligibility as a transmission asset. The orders have required transmission planning entities to provide a level playing field where ES can participate in the transmission planning process (TPP) without undue discrimination and preference of technology. These developments pave the way for ES to participate in transmission planning as a transmission asset. On the other hand, as a flexible resource, ES can play an important role in the electricity market to enable more renewable energy integration by providing energy and grid reliability services. This could bring more revenue in return.

25 ENERGY STORAGE↗

Retransmission of water resources data using the ERTS-1 data collection system

The Water Survey of Canada operates a network of approximately 2400 gauging stations at which water level data are collected. Nine DCPs were installed in isolated areas of northern and western Canada. It was felt that DCPs in these locations would be exposed to climatic conditions severe enough to provide a check on system reliability. Water level data are transmitted from all sites and, also, some of the DCPs are used to transmit ice break-up, water velocity, precipitation, air temperature, water stage recorder clock operation or DCP battery voltage. Consideration is being given to transmitting other parameters that would be of value in flood or flow forecasting. Results of the project have been excellent. There has been no data loss that can be attributed to failure of a DCP although data were lost because of sensor malfunctions. The quality of data collected compares favourably with that of the hard record obtained at the remote sites. Costs of using the ERTS Data Collection System are reasonable.

Halliday, R. A.↗

An Innovative Circuit Breaker for Renewable Power Grids

A key step towards a carbon-neutral future could be reached through dispersed power grids, featuring networks of local-scale renewable energy and battery storage plants. To prevent these power grids from damaging themselves and their surroundings when electrical faults arise, they must be integrated with ‘circuit breakers’, which temporarily interrupt the current flowing through them. However, currently available circuit breakers cannot handle the medium-voltage direct currents best suited for these grids. Through an innovative new circuit breaker design, Steve Schmalz and his colleagues at Eaton Corporation, the Illinois Institute of Technology (IIT), Virginia Tech and the National Energy Technology Laboratory (NETL), hope that this challenge will soon be overcome.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Experimental Investigation of Multilayer Flow in a Slide Die Coating Process

Roll-to-roll coating technology has been actively applied not only for conventional film production but also for emerging energy devices such as organic solar cells, organic light emitting diodes, batteries, smart windows, and fuel cells. The devices are multilayer structures requiring several coating and drying steps when implemented in a serial fashion, which increases capital costs and energy consumption. Simultaneous multilayer (ML) coating technologies present an opportunity for cost reductions and improved process efficiency by reducing equipment footprint and the number of process steps. In this talk, we experimentally investigate ML slide die coating flow for the manufacturing of fuel cell membrane electrode assemblies (MEAs). For ML slide coating, understanding fluid properties such as density, surface tension, and viscosity are necessary for stable flows and limiting intermixing of the miscible layers. Here, we utilize a design-of-experiment methodology - Box-Behnken design (BBD) - to correlate ink formulation parameters to fluid properties. Using the ink properties obtained from the BBD, we performed numerical flow simulations to obtain a proper process conditions to guide experimental coating trials. Finally, experimental verification is performed on a ML slide die and a degree of miscibility was observed for various ink formulation conditions.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Multi-layered Energy Management Framework for Extreme Fast Charging Stations Considering Demand Charges, Battery Degradation, and Forecast Uncertainties

To achieve a cost-effective and expeditious charging experience for extreme fast charging station (XFCS) owners and electric vehicle (EV) users, the optimal operation of XFCS is crucial. It is however challenging to simultaneously manage the profit from energy arbitrage, the cost of demand charges, and the degradation of a battery energy storage system (BESS) under uncertainties. This paper, therefore, proposes a multi-layered multi-time scale energy flow management framework for an XFCS by considering long- and short-term forecast uncertainties, monthly demand charges reduction, and BESS life degradation. In the proposed approach, an upper scheduling layer (USL) ensures the overall operation economy and yields optimal scheduling of the energy resources on a rolling horizon basis, thereby considering the long-term forecast errors. A lower dispatch layer (LDL) takes the short-term forecast errors into account during the real-time operation of the XFCS. Per the latest research, monthly demand charges can be as high as 90% of the total monthly bills for EV fast charging stations; to this end, this paper takes the first attempt at the reduction of demand charges cost by considering the trade-off between the energy cost and monthly demand charges. Contrasting literature, this work allocates an energy reserve in the BESS stored energy to deal with the impact of short-term forecast errors on the optimized real-time operation of the XFCS. Moreover, degradation modeling considers the trade-off between short-term benefits and long-term BESS life degradation. As a result, case studies and a comparative analysis prove the efficacy of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Alkaline Zinc Passivation Mechanism is Controlled by Hydroxide Concentration

We studied Zn passivation and oxide growth in Zincate (Zn(OH) 4 2− ) in 4 and 8 M KOH solutions using an electrochemical quartz crystal microbalance (EQCM), building on our initial work at 1 M KOH where passivation was kinetically controlled. A porous passivating oxide spontaneously forms on Zn electrodes when KOH is above 4 M and saturated with zincate. However, passivation does not occur when bulk zincate concentration is decreased, resulting in continual Zn dissolution. EQCM data suggests that the passivation mechanism is strongly affected by pOH. Mass transport and kinetic processes in the 4 M KOH electrolytes couple and govern Zn passivation. At 8 M, KOH concentration shifts passivation to mass transport control. We explain this by the increased solubility of Zn(OH) 3 − with increasing pOH. The variation in the mechanism of passivation implications for how passivation is handled in Zn-alkaline batteries. The importance of controlling the mass transport increases with increased pOH, suggesting that electrode design, additives, and potential flow should be optimized. At lower pOHs, kinetics and mass transport must be balanced to manage passivation effectively. Additionally, the changing nature of the native oxide layer on the surface has implications for the evenness of deposition and dissolution on the Zn electrode.

Wittman, Reed M. [Oak Ridge National Laboratory (O↗

Multichannel implantable telemetry system

Multiplexed biotelemetry system for animal research combines several power-saving features. Implantable sensor measures up to eight parameters simultaneously, including blood flow. Microamp transistors, switching circuits, and CMOS technology are used to lower power requirements. However, when blood flow is monitored, these measures are insufficient to reduce power enough for long-term operation from implantable primary battery.

Fryer, T. B.↗

NASA Engineering and Safety Center Technical Bulletin No. 11-01: Nickel-Hydrogen (NiH 2 ) Common Pressure Vessel (CPV) Cell Capacity Loss and Voltage Collapse

During an investigation of anomalous voltages during a NASA scientific mission, a NASA Engineering and Safety Center (NESC) team discovered that the design of NiH 2 CPV batteries may be susceptible to a unique electrolyte bridging between the two internal cells resulting in undesired ionic current flow. This condition can lead to depletion of the capacity within one of the two cells.

Nickel-Hydrogen↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Achieving SEI preformed graphite in flow cell to mitigate initial lithium loss

The irreversible lithium loss due to the formation of solid electrolyte interphase (SEI) in the initial cycle on the graphite anode greatly reduces the overall cell energy density of lithium ion batteries, that is, the lost Li ions from forming SEI lead to the decrease of Li ions for the intercalation. The method of cathode prelithiation has been widely explored to compensate this lithium loss. However, these cathode additives with high lithium contents inevitably lower the loading of the cathode active materials. In this work, we report a novel approach to solve this challenge, a facile graphite prelithiation method by preforming SEI layers on the surface of graphite powders (Pre-SEI graphite) utilizing a specially designed flow cell. The Li accommodation in the graphite anode can be controlled by the operating time and current density in the flow cell for the electrochemical SEI formation. As a result, we demonstrate a 10% initial Columbic efficiency increase of the LiFePO 4 electrode in a full cell configuration using the Pre-SEI graphite, compared with the pristine graphite anode. The electrochemical preformation of SEI on the graphite powders offers a complete solution to offset initial lithium loss without a sacrifice of active cathode material loading.

25 ENERGY STORAGE↗

Two-stage Stochastic Generalized Disjunctive Programming (GDP) Model for Proactive Planning and Reactive Operations of Resilient Power Systems under Disruptions

In this work, we propose a Generalized Disjunctive Programming (GDP) model that optimizes both long-term capacity planning (such as the number and size of dispatchable/renewable generators, batteries, and transmission lines) and hourly operation (such as on/off schedules of dispatchable generators, power output from each generator, and power flow) to maximize power system reliability while minimizing total cost and CO2 emissions.

Cho, Seolhee↗

Optimization Model and Algorithm for Capacity Planning and Operation of Reliable and Carbon-neutral Power Systems with High Penetration of Renewable Generation

In this work, we propose a Generalized Disjunctive Programming (GDP) model that optimizes both long-term capacity planning (such as the number and size of dispatchable/renewable generators, batteries, and transmission lines) and hourly operation (such as on/off schedules of dispatchable generators, power output from each generator, and power flow) to maximize power system reliability while minimizing total cost and CO2 emissions.

Cho, Seolhee↗

Control System Upgrade for Battery State-of-Charge Indications

The Advanced Test Reactor (ATR) Complex at Idaho National Laboratory (INL) relies on Battery Backed Power (BBP) systems and Uninterruptible Power Supplies (UPS) to ensure continuous power supply to critical components. This project aims to enhance the reliability and functionality of the battery monitoring and control systems by updating the State-of-Charge (SOC) system, Programmable Logic Controller (PLC), and Human-Machine Interface (HMI) for the nuclear safety-related battery banks. The current system, while functional, has areas for improvement, particularly in recharging calculations and alarm functions. The project objectives include developing flow charts, programming the new PLC and HMI, conducting bench tests, and updating design documentation. Additionally, the project ensures compliance with safety standards, develops training materials, creates comprehensive documentation, and integrates seamlessly with existing ATR infrastructure. The new SOC system is designed to be scalable for future upgrades, improve efficiency, enhance data accuracy, implement redundancy features, and achieve project goals within budget constraints while considering environmental impact. The methodology involved familiarizing with BBP and UPS systems, collecting current readings, rescaling signals, learning ladder logic, and updating the HMI. The transition from SLC 5/03 PLC using RS Logix 500 to CompactLogix 5380 using Studio 5000 was a key step. Despite challenges in transferring outdated PLC ladder logic and HMI code, starting from scratch led to a more accurate and efficient monitoring system, contributing to improved safety and operational efficiency. The project is currently awaiting approval of the Engineering Calculation and Analysis Report (ECAR) before implementation.

42 - ENGINEERING↗