Degree of vaporization using an airblast type injector for a premixed-prevaporized combustor
Vaporization data that could be useful in designing premixed-prevaporized fuel preparation systems for gas turbine combustors are presented. The effect of the experimental parameters on vaporization was found to be E = T sub in tau 0.18 (V sub ref + 38) (P sub in + 35)/203000 where E is the degree of vaporization in percent, T sub in the inlet air temperature in K over the range 450 to 700 K, the residence time in ms over the range 4.3 to 23.8 ms, V sub ref the reference velocity in m/s over the range 5 to 22 m/s, and P sub in the inlet pressure in MPa over the range 0.18 to 0.59 MPa. Jet A and Diesel no. 2 fuels were tested for the effect of inlet air temperature and were found to have nearly identical results.