Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Resource and Load Compatibility Assessment of Wind Energy Offshore of Humboldt County, California

Floating offshore wind is being considered in northern California as indicated by the Bureau of Ocean Energy Management’s issuance of a lease consideration in the Humboldt Call Area. Humboldt County offers access to this enormous resource, but local electric load and transmission are limited. The potential impacts of offshore wind generators at three different scales were studied using a regional grid model of Humboldt County. Offshore wind generation was calculated using modeled wind speed data and 12-MW turbine specifications and integrated with projected load and historical generation. Offshore wind farms deployed in the Humboldt Call Area achieve annual capacity factors between 45% and 54% after losses and maintenance. Power output is variable between and within seasons, with full power output 30% of the time and no output approximately 20% of the time. Electricity from a 48-MW wind farm provides 22% of regional load with limited exports. A 144-MW wind farm serves 38% of local load, exporting 40% of its electricity with the extant 70-MW transmission capacity. A full build-out of 1836 MW would result in 88% curtailment with existing transmission. Across scenarios, offshore wind variability necessitates reliance on existing power plants to meet local demand in periods of low wind.

17 WIND ENERGY↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Where Have All of the Electrons Gone? Understanding the Role of Alternative Electron Flow and O 2 Reduction in Balancing Cellular Redox (Final Technical Report)

An informed understanding of the fundamentals of light-driven electron transfer reactions in photoautotrophic organisms is necessary to enable improved photosynthetic efficiencies for the production of renewable fuels and novel biomaterials. To obtain high photosynthetic yields, light energy must be efficiently coupled to the fixation of CO 2 . Sub-optimal environmental conditions and metabolic routing (caused by blocks in biosynthetic routes) can severely impact the conversion of light energy to biomass and lead to reactive oxygen production, which in turn can cause cellular damage and productivity losses. Hence, plants, algae, and photosynthetic bacteria have evolved a network of alternative outlets to sustain the flow of photosynthetically derived-electrons. Our research was focused on the nature and integration of these outlets. The data obtained in this project will inform efforts to rationally engineer crop plants and algae to improve photosynthetic yields by enhancing electron transfer reactions to CO 2 reduction and targeted biomass accumulation. A major project research thrust was focused on identifying and quantifying the flow of photosynthetic reductant through electron transfer circuits that result in the light-dependent reduction of O 2 . New energy management strategies were identified that are used when normal carbon assimilation pathways are compromised due to nutrient deprivation, and/or by a reduction in starch synthesis/carbon storage, all conditions resulting in highly reduced intracellular redox pools. The green alga Chlamydomonas reinhardtii, and likely many other algae, have multiple O 2 -reducing pathways that play critical roles in maintaining cellular metabolic balance and scavenging electrons that could potentially cause cellular damage, which in some instances leads to reduced photosynthetic yields but increased fitness. We explored the activities of three essential outlets associated with Chlamydomonas reinhardtii photosynthetic electron transport: (1) reduction of O 2 to H 2 O through Flavodiiron proteins (FLVs) and (2) Plastid Terminal Oxidases (PTOX), and (3) the synthesis of starch. Real-time measurements of O 2 exchange demonstrated that FLVs immediately engage during dark to light transitions, allowing electron transport when the CBBC is not fully activated. Under these conditions, we quantified, for the first time, maximal FLV activity and its overall capacity to direct photosynthetic electrons towards O 2 reduction. However, when starch synthesis is compromised, a greater proportion of electrons is directed toward O 2 reduction through the FLVs, while PTOX, which is sensitive to the PQ pool redox state, is activated. This suggests, that starch synthesis has an important role in priming/regulating CBBC and electron transport. We also identified a biological ‘switch’ in the green alga Chlamydomonas reinhardtii that reversibly restricts photosynthetic electron transport (PET) at the cytochrome b 6 f complex when reductant and ATP generated by PET are in excess of the capacity of carbon metabolism to utilize these products; we specifically show a restriction at this switch when sta6 mutant cells, which cannot synthesize starch, are limited for nitrogen (growth inhibition) and subjected to a dark to light transition. This restriction causes diminished electron flow to PSI, which prevents PSI photodamage, and the plastid alternative oxidase (PTOX) becomes fully activated, serving as an electron valve that dissipates excitation energy absorbed by PSII, thereby lessening PSII photoinhibition. Furthermore, illumination of the cells following the dark acclimation gradually diminishes the restriction at the switch. Future engineering of these switches may allow more effective electron transfer to lipid (biofuel) pathways and diminish the number of electrons “wasted” in the reduction of O 2 to water. Lastly, we explored metabolic routing of electrons during algal fermentation and discovered multiple novel pathways that are activated when the preferred anoxic routes are blocked. These provide valuable products (e.g. lactate, glycerol) that can be used in broad portfolio of biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗

Skewering the silos: using Brick to enable portable analytics, modeling and controls in buildings

Nearly all large commercial buildings have heating, ventilation and air conditioning (HVAC) systems, lighting systems, safety and other systems controlled by a computer—a dedicated server with a building energy management system (BMS). However, these BMSs are proprietary with each building’s assets (that is, fans, valves, pumps, and their setpoints) named and coded uniquely by the BMS vendor or engineer; building analytics and control algorithms are written specific to the assets and the building. Thus, any control updates or analytics to improve building performance—especially critical to reduce greenhouse emissions or improve load flexibility—are labor intensive and costly. The Brick schema was developed so the same analysis or control algorithms can work on a variety of buildings if each is digitally represented in a Brick data model. The goal of this project was to further the development of Brick to extend it beyond an academic project with demonstrated success in a small field study, to a practical choice for industrial and commercial stakeholders seeking to realize value from building data. To do this, we executed four objectives: (1) expand the Brick schema including its modeling capabilities and vocabulary, (2) develop tools for integrating Brick with existing digital technologies and representations in buildings, (3) develop an open-source analytics platform to facilitate use of Brick in delivering data value, and (4) demonstrate Brick-driven analytics and controls in real settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Decarbonization through Autonomous Physics-Centric Deep Learning and Optimization of Building Operations (Abstract only)

This project directly addresses the primary goal of Area of Interest 2 in the CRADA call: to advance optimization-based integrated energy management systems in commercial and residential buildings. Pacific Northwest National Laboratory (PNNL) and its industry partner PassiveLogic aim to accomplish this by reaching three key objectives. First, to ensure a broad impact in the building controls industry, PNNL will extend its open-source library for predictive control synthesis by augmenting its capabilities with data-driven self-learning of building models and auto-calibration of predictive controllers. The effort will focus on building use cases selected in collaboration with PassiveLogic. The team will specifically address the development of methods for data-driven adaptation of building models, investigation of model architectures that best address specific building types, and automated synthesis of differentiable predictive controllers that optimize diverse objectives. Second, PNNL will collaborate with PassiveLogic to integrate the aforementioned methods with PasiveLogic’s advanced controls platform. The collaborative integration effort will inform the developments under the first objective by providing specific data on the attainable performance of model learning on resource-constrained edge computing platforms. This software integration effort will increase the technical maturity of the developed libraries by exploring the use of software integration tools and methods. Third, PNNL and PassiveLogic will work to improve the technology readiness of the developed predictive controllers by testing their performance in relevant test environments, such as high-fidelity simulation, hardware in the loop, and actual test buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two Air Quality Regimes in Total Column NO2 over the Gulf of Mexico in May 2019: Shipboard and Satellite Views

The Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf of Mexico was conducted in May 2019 by NASA and the Bureau of Ocean Energy Management to determine the feasibility of using satellite data to measure air quality in a region of concentrated oil and natural gas (ONG) operations. SCOAPE addressed both technological and scientific issues related to measuring NO2 columns over the Outer Continental Shelf. Featured were nitrogen dioxide (NO 2 ) instruments (Pandora, Teledyne API analyzer) at Cocodrie, LA (29.26°, -90.66°), and on the Research Vessel Point Sur operating off the Louisiana coast with measurements of ozone, carbon monoxide and volatile organic compounds (VOC). The findings: (1) All NO 2 observations revealed two atmospheric regimes over the Gulf, the first influenced by tropical air in 10-14 May, the second influenced by flow from urban areas on 15-17 May; (2) Comparisons of OMI v4 and TROPOMI v1.3 TC (total column) NO 2 data with shipboard Pandora NO 2 column observations averaged 13% agreement with the largest difference during 15-17 May (~20%). At Cocodrie, the satellite-Pandora agreement was ~5%. (3) Three new-model Pandora instruments displayed a TC NO 2 precision of 0.01 Dobson Units (~5%); (4) Regions of smaller, older natural gas operations showed high methane readings from leakage; elevated VOC were also detected. Neither satellite nor spectrometer captured the magnitude of ambient NO 2 variability near ONG platforms. Given an absence of regular air quality monitoring over the Gulf of Mexico, SCOAPE data constitute a baseline against which future observations can be compared.

Nitrogen dioxide↗

Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition

This report builds on the 2016 Water and Wastewater Annual Price Escalation Rates for Selected Cities across the United States report prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP). The 2017 report examined annual water and wastewater price escalation rate trends across the U.S. Annual water and wastewater price escalation rates are an important factor when conducting life-cycle cost analyses (LCCA) of water efficiency measures, which is required for Federal agencies. Following the framework of the 2017 report, PNNL used the American Water Works Association (AWWA) water and wastewater rate surveys to gather historical rate data for water and wastewater utilities in the US, which were used to calculate a sample set of water and wastewater annual price escalation rates (Figure E.1). An annual price escalation rate was calculated for 113 water utilities and 76 wastewater utilities that reported at least two AWWA surveys across the past 13 years (i.e., 2008 to 2021) and at least a five-year range between those two surveys. Statistical trends in the annual price escalation rates are also provided by the seven regions identified in Figure E.1. In the 2017 report, the average annual price escalation for the surveyed sample of water and wastewater rates were 3.0% and 3.2%, respectively. This report also calculated aggregate average annual price escalation rates for the surveyed sample of water and wastewater utilities to be 3.1% and 2.7%, respectively. These escalation rates were based on 87 water utilities and 46 wastewater utilities that reported data in at least two AWWA surveys with at least a five-year range between those two surveys and reported at least one AWWA survey in 2019 or 2021. Among water utilities, the highest average annual price escalation rate was 8.8%, and the highest average annual water de-escalation rate was -2.0%. And for wastewater utilities, the highest average annual wastewater price escalation rate was 10.2%, and the highest average annual wastewater de-escalation rate was -2.3%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Grid‐responsive smart manufacturing: A perspective for an interconnected energy future in the industrial sector

Abstract With the growing amount of renewable energy sources, the grid has become responsible for accounting for intermittency and the flexibility needed to utilize dynamic sources. Expensive peaking plants and energy storage systems have been proposed as ways to mitigate those problems. There is a large group of energy consumers that can respond to grid conditions. Historically, these consumers have been residential and commercial users, but with modern innovations and practices, industrial consumers have the potential to become a major player in this space. Grid‐responsive smart manufacturing can be used to utilize modern tools in manufacturing innovation as enablers for grid response. These modern tools already exist but are not widely used for industrial grid‐side energy management. This article defines grid‐responsive smart manufacturing, identifies five major barriers to its widespread implementation, and portrays the path to getting industrial users to be key players in grid stability and flexibility.

Billings, Blake W.↗

A general spatial-temporal framework for short-term building temperature forecasting at arbitrary locations with crowdsourcing weather data

Weather forecasting has been a critical component to predict and control building energy consumption for better building energy management. Without accessibility to other data sources, the onsite observed temperatures or the airport temperatures are used in forecast models. In this paper, we present a novel approach by utilizing the crowdsourcing weather data from neighboring personal weather stations (PWS) to improve the weather forecast accuracy around buildings using a general spatial-temporal modeling framework. The final forecast is based on the ensemble of local forecasts for the target location using neighboring PWSs. Our approach is distinguished from existing literature in various aspects. First, we leverage the crowdsourcing weather data from PWS in addition to public data sources. In this way, the data is at much finer time resolution (e.g., at 5-minute frequency) and spatial resolution (e.g., arbitrary location vs grid). Second, our proposed model incorporates spatial-temporal correlation information of weather variables between the target building and a set of neighboring PWSs so that underlying correlations can be effectively captured to improve forecasting performance. Here, we demonstrate the performance of the proposed framework by comparing to the benchmark models on temperature forecasting for a building located at an arbitrary location at San Antonio, Texas, USA. In general, the proposed model framework equipped with machine learning technique such as Random Forest can improve forecasting by 50% compares with persistent model and has 90% chance to outperform airport forecast in short-term forecasting. In a real-time setting, the proposed model framework can provide more accurate temperature forecasting results compared with using airport temperature forecast for most forecast horizon. Moreover, we analyze the sensitivity of model parameters to gain insights on how crowdsourcing data from the neighboring personal weather stations impacts forecasting performance. Finally, we implement our model in other cities such as Syracuse and Chicago to test the model's performance in different landforms and climate types.

54 ENVIRONMENTAL SCIENCES↗

Correlating real-world incidents with vessel traffic off the coast of Hawaii, 2017–2020

Abstract Objectives Because of the high-risk nature of emergencies and illegal activities at sea, it is critical that algorithms designed to detect anomalies from maritime traffic data be robust. However, there exist no publicly available maritime traffic data sets with real-world expert-labeled anomalies. As a result, most anomaly detection algorithms for maritime traffic are validated without ground truth. Data description We introduce the HawaiiCoast_GT data set, the first ever publicly available automatic identification system (AIS) data set with a large corresponding set of true anomalous incidents. This data set—cleaned and curated from raw Bureau of Ocean Energy Management (BOEM) and National Oceanic and Atmospheric Administration (NOAA) automatic identification system (AIS) data—covers Hawaii’s coastal waters for four years (2017–2020) and contains 88,749,176 AIS points for a total of 2622 unique vessels. This includes 208 labeled tracks corresponding to 154 rigorously documented real-world incidents.

99 GENERAL AND MISCELLANEOUS↗

Integrated Pumped Thermal and Liquid Air Energy Storage

Liquid air energy storage (LAES) and pumped thermal energy storage (PTES) are two closely related technologies that employ thermodynamic cycles to store electricity in the form of thermal energy. This chapter describes the integration of PTES and LAES in a single combined cycle (PT-LAES), where the PTES side provides the cold source required to drive the air liquefaction process. This presents several advantages compared to the separate cycles, including the partial or complete removal of cold stores, a higher energy density and the achievement of full air liquefaction. Notably, PT-LAES does not depend on external sources of heat or cold and thus constitutes a stand-alone system. As a result, PT-LAES can also be viewed as an advanced LAES cycle with full liquefaction.

Carnot batteries↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Peer-to-Peer Energy Systems for Connected Communities: A Review of Recent Advances and Emerging Challenges

After a century of relative stability of the electricity industry, extensive deployment of distributed energy resources and recent advances in computation and communication technologies have changed the nature of how we consume, trade, and apply energy. The power system is facing a transition from its traditional hierarchical structure to a more deregulated model by introducing new energy distribution models such as peer-to- peer (P2P) sharing for connected communities. The proven effectiveness of P2P sharing in benefiting both prosumers and the grid has been demonstrated in many studies and pilot projects. However, there is still no extensive implementation of such sharing models in today’s electricity markets. This paper aims to shed some light on this gap through a comprehensive overview of recent advances in the P2P energy system and an insightful discussion of the challenges that need to be addressed in order to establish P2P sharing as a viable energy management option in today’s electricity market. To this end, in this article, we provide some background on different aspects of P2P sharing. Then, we discuss advances in P2P sharing through a systematic domain-based classification. We also review different pilot projects on P2P sharing across the globe. Finally, we identify and discuss a number of challenges that need to be addressed for scaling up P2P sharing in the electricity market followed by concluding remarks at the end of the paper.

Tushar, Wayes↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Optimal sizing of battery energy storage systems for peak shaving and demand response using a degradation-aware Bayesian Optimization-Mixed-Integer Linear Programming framework

The increasing integration of renewable energy and rising electricity demand highlight the importance of battery energy storage systems for peak shaving and demand response. Unlike prior approaches that overlook operational impacts on degradation, this study proposes a Bayesian Optimization–Mixed Integer Linear Programming framework for optimal battery energy storage system sizing. In this framework, Mixed Integer Linear Programming determines short-term scheduling while a calibrated electrochemical model iteratively evaluates degradation. The central hypothesis is that the framework can efficiently identify optimal sizes that yield realistic and economically robust outcomes. The method is tested across three scenarios: peak shaving, peak shaving with energy-reduction demand response, and peak shaving with power-reduction demand response. Results show that the framework converge to the optimum within 20 iterations out of 150 possible sizes. Under baseline conditions, the framework consistently selects the smallest feasible system, minimizing unnecessary degradation costs from oversized storage. Sensitivity analyses reveal that larger systems are favored as demand rates or incentives increase. Comparisons of demand response programs indicate that power-reduction demand response offers greater economic benefits than energy-reduction demand response, although demand savings from peak shaving remain the dominant contributor to overall performance. This study demonstrates that the proposed framework balances computational tractability with degradation fidelity, identifies critical economic thresholds for investment, and offers a practical, flexible tool to guide industrial stakeholders in cost-effective battery energy storage system deployment.

Batteries↗