Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Application of electrospinning for the fabrication of proton-exchange membrane fuel cell electrodes

We report electrospun materials have been gaining great interest in the energy sector. Their tunability and robustness make them highly attractive, particularly for proton-exchange membrane fuel cell (PEMFC) electrodes. Conventional PEMFC electrodes, prepared by either spraying, painting, or slot-die coating, have not yet met the needs of large-scale PEMFC use. Electrospinning of fibrous materials has already shown great promise as an alternative methodology for electrode fabrication. Electrospinning has been used in fuel cell electrodes through two primary means: (1) segmented carbon or inorganic fibers to serve as precious metal catalyst support, and (2) high aspect ratio polymer/particle fibers to serve directly as the electrode. The use of electrospun fibrous electrodes has led to improved PEMFC durability and increased power output at low catalyst loadings, both of which are of paramount importance to large-scale commercialization of PEMFC electric vehicles.

36 MATERIALS SCIENCE↗

Process design of the piperazine advanced stripper for a 460 MW NGCC

The Texas Carbon Management Program is conducting a Front-End Engineering Design (FEED) for Piperazine with the Advanced Stripper™ (PZAS™) at a natural gas combined cycle power plant in west Texas. Here, this paper presents the design of the advanced stripper system with an emphasis on the selection of packing type, packing height, column diameter, and heat exchanger size, demonstrates the effect of ambient temperature swing on the regeneration energy requirement, and investigates two alternate process configurations that provide better energy performance than PZAS™. The design uses 2 stripper trains, and each train uses two cold cross exchangers, one hot cross exchanger, a stripper column, a CO 2 exchanger, and a condenser. Each column consists of two sections of random packing with RSR 2 packing at the top and RSR 3 packing at the bottom, with a total packed height of 7.5 m. The cold exchanger was designed with an NTU of 6, the hot exchanger with an NTU of 2, and the CO 2 exchanger with an NTU of 5. At 0.4 rich loading and 0.2 lean loading, this design resulted in a heat duty of 2.85 GJ/tonne CO 2 . The heat duty can vary up to 3.1 GJ/tonne CO 2 due to lower rich loading at higher summer temperature, but the absolute steam requirement is 8–15% lower in the summer. An alternate design, PZAS with hot rich bypass, is proposed, which can reduce the equivalent work of stripping by 1.5–3.5% compared to PZAS at low heat exchanger size, due to a reduction in stripper driving force. Using a hot rich bypass increases the vapor fraction of the total rich bypass stream from 0.3 to 1 mol% compared to using the warm rich bypass, which also contributes to a reduction in lost work in the column. PZAS with hot rich bypass outperforms PZAS in energy requirement below a packing height of 15 m, but fails to do so above 15 m of packing due to a column pinch that results in little change in LMTD of the column. PZAS with hot rich bypass has the potential to minimize capital cost in addition to reducing energy requirement as it requires less packing to strip CO 2 than PZAS and requires only one cross exchanger with 8 heat transfer units.

03 NATURAL GAS↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

A Ranked-Orbital Approach to Select Active Spaces for High-Throughput Multireference Computation

The past decade has seen a great increase in the application of high-throughput computation to a variety of important problems in chemistry. However, one area which has been resistant to the high-throughput approach is multireference wave function methods, in large part due to the technicalities of setting up these calculations and in particular the not always intuitive challenge of active space selection. As we look toward a future of applying high-throughput computation to all areas of chemistry, it is important to prepare these methods for large-scale automation. Here, we propose a ranked-orbital approach to select active spaces with the goal of standardizing multireference methods for high-throughput computation. This method allows for the meaningful comparison of different active space selection schemes and orbital localizations, and we demonstrate the utility of this approach across 1120 multireference calculations for the excitation energies of small molecules. Our results reveal that it is helpful to distinguish the method used to generate orbitals from the method of ranking orbitals in terms of importance for the active space. Additionally, we propose our own orbital ranking scheme that estimates the importance of an orbital for the active space through a pair-interaction framework from orbital energies and features of the Hartree–Fock exchange matrix. Here, we call this new scheme the “approximate pair coefficient” (APC) method and we show that it performs quite well for the test systems presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Multi-Material Topology Optimization for High Performance Heat Exchangers

This award allowed RTX Technology Research Center to demonstrate several key objectives related to the design and manufacture of additive heat exchangers. The focus of the project was on creating a multi-physics, multi-material topology optimization tool, then using it to create an ultra-compact, optimized, fully additive heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low‐PGM and PGM‐Free Catalysts for Proton Exchange Membrane Fuel Cells: Stability Challenges and Material Solutions

Abstract Fuel cells as an attractive clean energy technology have recently regained popularity in academia, government, and industry. In a mainstream proton exchange membrane (PEM) fuel cell, platinum‐group‐metal (PGM)‐based catalysts account for ≈50% of the projected total cost for large‐scale production. To lower the cost, two materials‐based strategies have been pursued: 1) to decrease PGM catalyst usage (so‐called low‐PGM catalysts), and 2) to develop alternative PGM‐free catalysts. Grand stability challenges exist when PGM catalyst loading is decreased in a membrane electrode assembly (MEA)—the power generation unit of a PEM fuel cell—or when PGM‐free catalysts are integrated into an MEA. More importantly, there is a significant knowledge gap between materials innovation and device integration. For example, high‐performance electrocatalysts usually demonstrate undesired quick degradation in MEAs. This issue significantly limits the development of PEM fuel cells. Herein, recent progress in understanding the degradation of low‐PGM and PGM‐free catalysts in fuel cell MEAs and materials‐based solutions to address these issues are reviewed. The key factors that degrade the MEA performance are highlighted. Innovative, emerging material concepts and development of low‐PGM and PGM‐free catalysts are discussed.

Du, Lei↗

A Community Energy Operations and Planning System: Concept, Use cases, Metrics, and Benefits

Community and city leaders are interested in achieving sustainability goals, providing resilient energy infrastructure, and improving economic competitiveness. Community-level data acquisition and analysis can provide energy and associated benefits that are not possible at the single building level. However, there is a lack of organizational structure, common semantic data models, interoperable systems, and methods to support data-driven decision-making for community-scale energy supply and demand systems. We explored the need and opportunity for a Community Energy Operations and Planning System (Community EOPS), a potential data exchange platform. We conducted “customer discovery” interviews, and reviewed literature, public tools, and technology platforms to identify key energy data “users” and use cases in communities. The key users of the Community EOPS could be developers of mixed-use districts, corporate, defense and university campus energy managers, and city managers of cities that own their energy utility. The value could be for community planning and reporting (for energy data-integrated land use planning and community infrastructure investments in microgrids, storage, district heating and cooling), energy efficiency (leveraging optimizations for community scale energy supply and demand), flexible load management (grid-edge load management to offset, shift, and flatten loads for multiple buildings and EV fleets), cost savings and revenue generation (participating in grid services), and social benefits such as energy resilience, equity, and awareness. We developed a conceptual Community EOPS architecture with recommendations for streamlined and prioritized data acquisition, sharing, and integration driven by prioritized use cases, common metrics, and actionable visualizations that can provide value to a community’s users.

Singh, Reshma↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

Modeling Multi-Step Organic Reactions: Can Density Functional Theory Deliver Misleading Chemistry?

Many organic reactions are characterized by a complex mechanism with a variety of transition states and intermediates of different chemical natures. Their correct and accurate theoretical characterization critically depends on the accuracy of the computational method used. In this work, we study a complex ambimodal cycloaddition with five transition states, two intermediates, and three products, and we ask whether density functional theory (DFT) can provide a correct description of this type of complex and multifaceted reaction. Our work fills a gap in that most systematic benchmarks of DFT for chemical reactions have considered much simpler reactions. Our results show that many density functionals not only lead to seriously large errors but also differ from one another in predicting whether the reaction is ambimodal. Only a few of the available functionals provide a balanced description of the complex and multifaceted reactions. The parameters varied in the tested functionals are the ingredients, the treatment of medium-range and nonlocal correlation energy, and the inclusion of Hartree–Fock exchange. Furthermore, these results show a clear need for more benchmarks on the mechanisms of large molecules in complex reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BuildingSync® v.2.7.0 (released 9.11.2025) [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. Version 2.7.0 adds new elements for file attachment feature and FederalBuilding, and generalizes usage of Optional Elements (e.g. EquipmentCondition, EquipmentID) to all assets/systems. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas [National Renewable Energy Lab. (NR↗

Powering the Woods Hole X-Spar Buoy with Ocean Wave Energy—A Control Co-Design Feasibility Study

Despite its success in measuring air–sea exchange, the Woods Hole Oceanographic Institution’s (WHOI) X-Spar Buoy faces operational limitations due to energy constraints, motivating the integration of an energy harvesting apparatus to improve its deployment duration and capabilities. This work explores the feasibility of an augmented, self-powered system in two parts. Part 1 presents the collaborative design between X-Spar developers and wave energy researchers translating user needs into specific functional requirements. Based on requirements like desired power levels, deployability, survivability, and minimal interference with environmental data collection, unsuitable concepts are pre-eliminated from further feasibility study consideration. In part 2, we focus on one of the promising concepts: an internal rigid body wave energy converter. We apply control co-design methods to consider commercial of the shelf hardware components in the dynamic models and investigate the concept’s power conversion capabilities using linear 2-port wave-to-wire models with concurrently optimized control algorithms that are distinct for every considered hardware configuration. During this feasibility study we utilize two different control algorithms, the numerically optimal (but acausal) benchmark and the optimized damping feedback. We assess the sensitivity of average power to variations in drive-train friction, a parameter with high uncertainty, and analyze stroke limitations to ensure operational constraints are met. Our results indicate that a well-designed power take-off (PTO) system could significantly extend the WEC-Spar’s mission by providing additional electrical power without compromising data quality.

autonomous systems↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Interfacial magnetic vortex formation in exchange-coupled hard-soft magnetic bilayers

The exchange coupling between a hard magnetic layer MnBi and a soft magnetic layer Co-Fe has been found to significantly improve the maximum energy product. In this work, the spin structure of exchange coupled MnBi:Co-Fe bilayers is experimentally investigated by X-ray magnetic circular dichroism (XMCD) and polarized neutron reflectometry (PNR). We find that the out-of-plane magnetization reversal process of the MnBi:Co-Fe bilayer structure involves formation of a curling-type twisting of the magnetization in the film plane at low or intermediate reversal fields. Additionally, micromagnetic simulations are further performed to provide a detailed view of the spins at the curling center. Reminiscent of chiral spin structures known as spin bobbers, this curling in the exchange-coupled hard-soft magnetic bilayers is a new type of skyrmionic spin structure and worth further investigation.

36 MATERIALS SCIENCE↗

Accelerated Energy Storage Deployment in RELAC Countries

"Renewables in Latin America and the Caribbean" or RELAC is a regional initiative across Latin America and the Caribbean (LAC) that was created at the end of 2019, within the framework of the United Nations Climate Action Summit, with the objective of reaching at least 70% of renewable energy installed capacity, and 80% of the region's total electricity generation from renewables by 2030. 16 countries are members (Barbados, Bolivia, Chile, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Haiti, Honduras, Nicaragua, Panama, Paraguay, Peru, and Uruguay), and others are in discussions to join. RELAC provides these countries with support in addressing technical and financial needs to increase renewable energy penetration, matchmaking with financial resources to support capacity building needs and implementation of RE expansion plans, and knowledge exchange via peer-learning, and best practices in renewable energy integration to the electrical grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Implementación acelerada del almacenamiento de energía en los países de RELAC [Accelerated Energy Storage Deployment in RELAC Countries]

"Renewables in Latin America and the Caribbean" or RELAC is a regional initiative across Latin America and the Caribbean (LAC) that was created at the end of 2019, within the framework of the United Nations Climate Action Summit, with the objective of reaching at least 70% of renewable energy installed capacity, and 80% of the region's total electricity generation from renewables by 2030. 16 countries are members (Barbados, Bolivia, Chile, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Haiti, Honduras, Nicaragua, Panama, Paraguay, Peru, and Uruguay), and others are in discussions to join. RELAC provides these countries with support in addressing technical and financial needs to increase renewable energy penetration, matchmaking with financial resources to support capacity building needs and implementation of RE expansion plans, and knowledge exchange via peer-learning, and best practices in renewable energy integration to the electrical grid. This is the Spanish translation of NREL/TP-7A40-89643.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimization and Techno-Economic Comparison of Regenerators and Recuperators in sCO2 Recompression Brayton Cycles for Concentrating Solar Power Applications

Supercritical CO2 power cycles might be capable of providing the cost reductions and efficiency improvements necessary to reach concentrating solar power (CSP) cost targets, but require large, highly effective recuperators. Fixed-bed regenerators are a periodic heat exchanger that could be an effective yet low-cost alternative to these recuperators. This study presents a techno-economic comparison of regenerators and recuperators for a 100 MWe supercritical CO2 power cycle for CSP applications. We quantify the levelized cost of energy (LCOE) for the power plant with both types of heat exchangers, and explore sensitivity of LCOE to parameters such as CSP-specific capital costs, power cycle component capital costs, and regenerator valve replacements costs. Results indicate that the incumbent printed circuit heat exchangers achieve the lowest LCOE, unless the upper extreme of PCHE capital cost and lower extremes of regenerator and valve capital and O&M costs are realized. Sensitivity analysis also illustrates that the primary heat exchanger cost is the most influential of power cycle components, and that CSP component capital cost is more influential than power cycle capital costs. This illustrates the importance of reducing the cost of heliostats, receivers, and thermal energy storage for achieving CSP LCOE targets.

OTHER INSTRUMENTATION,SOLAR ENERGY↗