Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Emulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Simulation-based Testing of Control Software

It is impossible to adequately test complex software by examining its operation in a physical prototype of the system monitored. Adequate test coverage can require millions of test cases, and the cost of equipment prototypes combined with the real-time constraints of testing with them makes it infeasible to sample more than a small number of these tests. Model based testing seeks to avoid this problem by allowing for large numbers of relatively inexpensive virtual prototypes that operate in simulation time at a speed limited only by the available computing resources. In this report, we describe how a computer system emulator can be used as part of a model based testing environment; specifically, we show that a complete software stack including operating system and application software - can be deployed within a simulated environment, and that these simulations can proceed as fast as possible. To illustrate this approach to model based testing, we describe how it is being used to test several building control systems that act to coordinate air conditioning loads for the purpose of reducing peak demand. These tests involve the use of ADEVS (A Discrete Event System Simulator) and QEMU (Quick Emulator) to host the operational software within the simulation, and a building model developed with the MODELICA programming language using Buildings Library and packaged as an FMU (Functional Mock-up Unit) that serves as the virtual test environment.

97 MATHEMATICS AND COMPUTING↗

OpenSHMEM Implementation of IOR Benchmark

The benchmarking effort within the Computational Research & Development Programs at the Oak Ridge National Laboratory (ORNL) seeks to design and enable High Performance Computing (HPC) benchmarks and test suites. The work described in this report is a part of the effort focusing on the comparison and analysis of OpenSHMEM implementations using the Interleave Or Random (IOR) software for benchmarking parallel file system using POSIX, MPIIO, or HDF5 interfaces. We describe the effort to emulate the MPIIO parallel collective capabilities in the IOR benchmark using OpenSHMEM communication. One development effort was in emulating the MPI derived datatype used in the read/write operations and in setting the file view. Another effort was in implementing an internal cache in OpenSHMEM distributed shared memory to facilitate global collective I/O operations. Experiments comparing collective I/O in MPIIO implementations with the OpenSHMEM implementations were performed on the SGI Turing Cluster and the Cray XK7 Titan supercomputer at the Oak Ridge Leadership Computing Facility (OLCF). The preliminary results suggest that on the Cray XK7 Titan, the MPIIO implementations obtained higher write performance and the OpenSHMEM version obtained slightly higher read performance. On the SGI Turing Cluster, the MPIIO implementations obtained slightly higher performance over the OpenSHMEM implementations on large files.

97 MATHEMATICS AND COMPUTING↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combining Observational and Computational Uncertainty in Calibration Experiments

Traditional computer experiments using emulators have treat the emulator output as containing no error; however, this is not always feasible, as there exist computational codes which produce stochastic output, and future computations may require a balance between the time or resources to run the code and the accuracy of the output. This paper proposes a framework for incorporating both computational uncertainty and observational uncertainty into an analysis using a Gaussian process regression and calibration, and provides an example using simulated output from the one-dimensional diffusion equation. The particular values of observational and computation uncertainty which minimize a cost function are obtained.

97 MATHEMATICS AND COMPUTING↗

Fermi Gases in Bichromatic Superlattices

The purpose of the program is the broad study of designer materials made of ultra-cold atoms and light, which provides new paradigms for emulating exotic layered systems. Bichromatic superlattices enable control and study of both dimensionality and dispersion in layered, strongly correlated Fermi gases, to model high-temperature superfluidity/superconductivity. Most layered materials are quasi-two-dimensional, neither two-dimensional, like a sheet, nor three-dimensional, like a gas, but somewhere in between. In quasi-2D layers with an unequal number of spin-up and spin-down electrons, particularly strong attraction between pairs of electrons with opposite spins is predicted to achieve the highest possible superconducting transition temperatures. To understand these materials, we emulate them with a layered, ultra-cold Fermi gas of 6Li atoms, magnetically tuned near a collisional (Feshbach) resonance, where precise control of the attraction, spin-composition, dimensionality and dispersion provides new tests of theory. The primary goals are of the program are: (1) Elucidation of the effects of dimensionality and confining potential shape on the enhancement of high-temperature superfluidity in a layered, strongly correlated Fermi gases; (2) Control of dispersion and the study of tunable Dirac points in one dimension.

36 MATERIALS SCIENCE↗

Module OT Laboratory Test Procedure

This document will detail a test procedure, involving bench and emulation testing, for the Module OT device developed for the joint NREL-SNL DOE CEDS project titled "Modular Security Apparatus for Managing Distributed Cryptography for Command & Control Messages on Operational Technology (OT) Networks." The aim of this document is to create the testing and evaluation protocol for the module for lab-level testing; this includes checklists and experiments for information gathering, functional testing, cryptographic implementation, public key infrastructure, key exchange/authentication, encryption, and implementation testing in the emulation environment.

97 MATHEMATICS AND COMPUTING↗

Quantifying Uncertainties of Microscopic Nuclear Theories

The goal of this project was to produce modernized nuclear data libraries of light ion fusion reactions and actinide fission product yields. Such libraries are essential input in both stockpile science but also fundamental science (nucleosynthesis, superheavy nuclei). When such libraries are used to model complex processes involving exotic, very short-lived nuclei that have not been measured experimentally, the underlying nuclear data come from theoretical models, the predictive power of which needs to be quantified, together with its uncertainties. By teaming up nuclear theorists and statisticians, we built comprehensive theoretical frameworks based on the most fundamental theories of fusion and fission that we coupled for the first time with a Bayesian framework with machine learning techniques for uncertainty quantification. Our results include: (1) statistical emulators for neutron-alpha scattering, and the fission product mass yields of neutron-induced fission of 239 Pu, which will enable developers to generate random realizations of the corresponding data for uncertainty quantification (UQ) in applications; (2) the first complete and most accurate ab initio prediction of the S-factor for proton capture on 7 Be, which – combined with UQ – may become the recommended value at solar energies in the next review of solar fusion cross sections; (3) statistical emulators for fission mass yields in the neutron-induced fission of 239 Pu; (4) the first quantification of how uncertainties in nuclear forces impact fission properties that are relevant in nucleosynthesis simulations to explain how heavy elements are formed in the Cosmos.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test samples and infrastructure for accelerator magnet developments

LHC still does not operate at full energy due to training features in magnets. Higher field practical superconductors (Nb 3 Sn) show much worse training behavior than NbTi. Most magnet performance issues relate to quenching, and it is this phenomenon and its dependencies that need to be understood for us to succeed addressing them in magnets. For pragmatic and scientific reasons underlying mechanisms are hard to investigate in real magnets. Available data suggest that emulating local conditions at quench location may be enough to arrive at a good understanding of what drives observed behavior. "Local" conditions imply emulation by small samples of cables/"stacks" powered within a facility with controllable conditions, including external magnetic and force fields. This paper argues about the necessity of this approach, while reminding current understanding and directions of quench studies, and pointing out inadequacy of available techniques. Improved facilities and change of perspective are required for consistent and affordable development.

43 PARTICLE ACCELERATORS↗

Harmonized Automatic Relay Mitigation of Nefarious Intentional Events (HARMONIE) - Special Protection Scheme (SPS)

The harmonized automatic relay mitigation of nefarious intentional events (HARMONIE) special protection scheme (SPS) was developed to provide adaptive, cyber-physical response to unpredictable disturbances in the electric grid. The HARMONIE-SPS methodology includes a machine learning classification framework that analyzes real time cyber-physical data and determines if the system is in normal conditions, cyber disturbance, physical disturbance, or cyber-physical disturbance. This classification then informs response, if needed and/or suitable, and included cyber-physical corrective actions. Beyond standard power system mitigations, a few novel approaches were developed that included a consensus algorithm-based relay voting scheme, an automated power system triggering condition and corrective action pairing algorithm, and a cyber traffic routing optimization algorithm. Both the classification and response techniques were tested within a newly integrated emulation environment composed of a real-time digital simulator (RTDS) and SCEPTRE™. This report details the HARMONIE-SPS methodology, highlighting both the classification and response techniques, and the subsequent testing results from the emulation environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harnessing Uncertainty through Functional Data Analysis in Gas Breakthrough Data

Detecting subsurface explosions from radionuclide gas migration through rock fractures is an effective way to identify nuclear activity. Los Alamos National Laboratory (LANL) has developed simulation methods, based on data from the 1962 Hardhat underground nuclear test, to predict gas breakthrough times at the surface. However, these methods rely on an imperfect understanding of the relationship between rock damage and fracture permeability. Our clinic project studies methods for predicting breakthrough curves that characterize total mass produced as a function of time, as well as quantifying the uncertainty associated with these predictions. The model that is currently employed to relate damage to permeability uses an empirically motivated power-law expression, with a range of parameter values that are compatible with the experimental Hardhat data. We develop emulators, built from functional data analysis techniques and trained on simulation data, that rapidly predict the gas breakthrough curve given a damage field and given the parameter values of the power-law equation. Using Bayesian regression, we address the problem of uncertainty quantification in our emulators. Finally, in order to test the robustness of the model, we further validate it on a damage field representing different physical conditions.

58 GEOSCIENCES↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Sustainable Energy Solutions Task 1.0: Networked Monitoring and Control of Small Interconnected Wind Energy Systems

This report presents accomplishments, results, and future work for one task of five in the Wichita State University Sustainable Energy Solutions Project: To develop a scale model laboratory distribution system for research into questions that arise from networked control and monitoring of low-wind energy systems connected to the AC distribution system. The lab models developed under this task are located in the Electric Power Quality Lab in the Engineering Research Building on the Wichita State University campus. The lab system consists of four parts: 1. A doubly-fed induction generator 2. A wind turbine emulator 3. A solar photovoltaic emulator, with battery energy storage 4. Distribution transformers, lines, and other components, and wireless and wired communications and control These lab elements will be interconnected and will function together to form a complete testbed for distributed resource monitoring and control strategies and smart grid applications testing. Development of the lab system will continue beyond this project.

17 WIND ENERGY↗

Novel Rotated Virtual Synchronous Generator Control for Power-Sharing in Microgrids with Complex Line Impedance

Virtual synchronous generator (VSG) control is based on the fact that the line impedance in a microgrid is highly inductive. This assumption was made due to the emulation of the stator winding of an electrical machine. This concept can affect the controllability of a microgrid with complex line impedance, generating deviations in the chosen operation point. To overcome this issue, additional techniques must be implemented. This paper describes a novel mathematical approach that uses the power line characteristics in a microgrid to rotate the power control reference frame and proposes a new control method called a “Rotated Virtual Synchronous Generator” (RVSG). This RVSG control approach integrates the effect of complex impedance on the microgrid’s operation and adjusts the reference frame accordingly to improve the system’s stability and performance. The use of this proposed mathematical approach in microgrids allows the further emulation of virtual inertia in microgrids that lack inertia. Finally, a comparison between RVSG control and the classical virtual synchronous generator method is carried out to show that it allows the improvement of the transient power response, power quality, stability, and performance, mainly in microgrids with complex line impedance.

42 ENGINEERING↗

SHOULD ONE USE THE RAY-BY-RAY APPROXIMATION IN CORE-COLLAPSE SUPERNOVA SIMULATIONS?

We perform the first self-consistent, time-dependent, multi-group calculations in two dimensions (2D) to address the consequences of using the ray-by-ray+ transport simplification in core-collapse supernova simulations. Such a dimensional reduction is employed by many researchers to facilitate their resource-intensive calculations. Our new code (Fornax) implements multi-D transport, and can, by zeroing out transverse flux terms, emulate the ray-by-ray+ scheme. Using the same microphysics, initial models, resolution, and code, we compare the results of simulating 12, 15, 20, and 25 M {sub ⊙} progenitor models using these two transport methods. Our findings call into question the wisdom of the pervasive use of the ray-by-ray+ approach. Employing it leads to maximum post-bounce/pre-explosion shock radii that are almost universally larger by tens of kilometers than those derived using the more accurate scheme, typically leaving the post-bounce matter less bound and artificially more “explodable.” In fact, for our 25 M {sub ⊙} progenitor, the ray-by-ray+ model explodes, while the corresponding multi-D transport model does not. Therefore, in two dimensions, the combination of ray-by-ray+ with the axial sloshing hydrodynamics that is a feature of 2D supernova dynamics can result in quantitatively, and perhaps qualitatively, incorrect results.

79 ASTRONOMY AND ASTROPHYSICS↗

The Aemulus Project. I. Numerical Simulations for Precision Cosmology

The rapidly growing statistical precision of galaxy surveys has led to a need for ever more precise predictions of the observables used to constrain cosmological and galaxy formation models. The primary avenue through which such predictions will be obtained is suites of numerical simulations. These simulations must span the relevant model parameter spaces, be large enough to obtain the precision demanded by upcoming data, and be thoroughly validated in order to ensure accuracy. In this paper, we present one such suite of simulations, forming the basis for the AEMULUS Project, a collaboration devoted to precision emulation of galaxy survey observables. We have run a set of 75 (1.05 h(-1) Gpc)(3) simulations with mass resolution and force softening of 3.51 x 10(10) (Omega(m)/0.3) h(-1) M-circle dot and 20 h(-1) kpc, respectively, in 47 different wCDM cosmologies spanning the range of parameter space allowed by the combination of recent cosmic microwave background, baryon acoustic oscillation, and Type Ia supernova results. We present convergence tests of several observables including spherical overdensity halo mass functions, galaxy projected correlation functions, galaxy clustering in redshift space, and matter and halo correlation functions and power spectra. We show that these statistics are converged to 1% (2%) or to the sample variance of the statistic, whichever is larger, for halos with more than 500 (200) particles, respectively, and scales of r > 200 h(-1) kpc. in real space or k similar to 3 h Mpc(-1). in harmonic space for z <= 1. We find that the dominant source of uncertainty comes from varying the particle loading of the simulations. This leads to large systematic errors for statistics using halos with fewer than 200 particles and scales smaller than k similar to 4 h Mpc(-1). We provide the halo catalogs and snapshots detailed in this work to the community at. https://AemulusProject.github.io.

large-scale structure of universe↗

Joint Analysis of Small-scale Galaxy Clustering and Galaxy–Galaxy Lensing from BOSS Galaxies

We present a joint analysis of galaxy clustering and galaxy–galaxy lensing measurements from BOSS galaxies using a simulation-based emulation method combined with a halo occupation distribution model. Our emulators are constructed with the Aemulus ν simulations, a suite of wνCDM N-body simulations with massive neutrinos as independent particle species. We combine small-scale analysis of clustering from 0.1 to 60.2 h −1 Mpc and lensing from 1.7 to 60.2 h −1 Mpc to perform cosmological constraints. We split the BOSS galaxies into three redshift bins to measure their clustering and employ galaxies from Dark Energy Camera Legacy Survey and Hyper Suprime-Cam as source galaxies to measure lensing separately. We find that the addition of lensing significantly improves the constraining power on $S_8 = σ_8(Ω_m/0.3)^{0.5}$, with a weak improvement for fσ 8 . Our results of fσ 8 indicate tensions of around 1σ−4σ below the results of the cosmic microwave background observations of Planck. For S 8 , our results are also lower than Planck, and the tension can be mitigated when considering possible systematics in lensing measurement. As a by-product, our analysis prefers a nonzero neutrino mass but without strong significance, with the constraining power dominated by the clustering. Given the accuracy and precision of our model and the observational data, it is anticipated that larger and higher-quality spectroscopic data sets will improve the constraints on this fundamental property in the near future.

Gao, Wenhao [Shanghai Jiao Tong University (China)↗