Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXERCISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Physical characterization of uranium oxide pellets and powder applied in the Nuclear Forensics International Technical Working Group Collaborative Materials Exercise 4

Physical characterization is one of the most broad and important categories of techniques to apply in a nuclear forensic examination. Physical characterization techniques vary from simple weighing and dimensional measurements to complex sample preparation and scanning electron microscopy-electron backscatter diffraction analysis. This paper reports on the physical characterization conducted by several international laboratories participating in the fourth Collaborative Materials Exercise, organized by the Nuclear Forensics International Technical Working Group. Methods include a range of physical measurements, microscopy-based observations, and profilometry. In conclusion, the value of these results for addressing key investigative questions concerning two uranium dioxide pellets and a uranium dioxide powder is discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

The 2014 Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty revisited: The case for data fusion

The International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) uses a global network of radionuclide monitoring stations to detect evidence of a nuclear explosion. The two radionuclide technologies employed—particulate and noble gas (radioxenon) detection—have applications for data fusion to improve detection of a nuclear explosion. Using the hypothetical 0.5 kT nuclear explosive test scenario of the CTBTO 2014 Integrated Field Exercise, the intrinsic relationship between particulate and noble gas signatures has been examined. Here this study shows that, depending upon the time of the radioxenon release, the particulate progeny can produce the more detectable signature. Thus, as both particulate and noble gas signatures are inherently coupled, the authors recommend that the sample categorization schemes should be linked.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Impact of Exercise during Radiation Therapy for Prostate Cancer on Fatigue and Quality of Life: A Systematic Review and Meta-analysis

Radiation therapy (RT) is clinically proven to improve survival in men with prostate cancer. Despite these advantages, it is known to cause adverse effects such as fatigue. This review proposes to summarize the totality of evidence from randomized controlled trials regarding the effectiveness of exercise on fatigue in men with prostate cancer as a primary outcome. Quality of life was a secondary outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sexual dimorphism and the multi-omic response to exercise training in rat subcutaneous white adipose tissue

Subcutaneous white adipose tissue (scWAT) is a dynamic storage and secretory organ that regulates systemic homeostasis, yet the impact of endurance exercise training (ExT) and sex on its molecular landscape is not fully established. Utilizing an integrative multi-omics approach, and leveraging data generated by the Molecular Transducers of Physical Activity Consortium (MoTrPAC), we show profound sexual dimorphism in the scWAT of sedentary rats and in the dynamic response of this tissue to ExT. Specifically, the scWAT of sedentary females displays -omic signatures related to insulin signaling and adipogenesis, whereas the scWAT of sedentary males is enriched in terms related to aerobic metabolism. These sex-specific -omic signatures are preserved or amplified with ExT. Integration of multi-omic analyses with phenotypic measures identifies molecular hubs predicted to drive sexually distinct responses to training. Overall, this study underscores the powerful impact of sex on adipose tissue biology and provides a rich resource to investigate the scWAT response to ExT.

59 BASIC BIOLOGICAL SCIENCES↗

PLATO hare-and-hounds exercise: asteroseismic model fitting of main-sequence solar-like pulsators

ABSTRACT Asteroseismology is a powerful tool to infer fundamental stellar properties. The use of these asteroseismic-inferred properties in a growing number of astrophysical contexts makes it vital to understand their accuracy. Consequently, we performed a hare-and-hounds exercise where the hares simulated data for six artificial main-sequence stars and the hounds inferred their properties based on different inference procedures. To mimic a pipeline such as that planned for the PLATO mission, all hounds used the same model grid. Some stars were simulated using the physics adopted in the grid, others a different one. The maximum relative differences found (in absolute value) between the inferred and true values of the mass, radius, and age were 4.32, 1.33, and 11.25 per cent, respectively. The largest systematic differences in radius and age were found for a star simulated assuming gravitational settling, not accounted for in the model grid, with biases of −0.88 per cent (radius) and 8.66 per cent (age). For the mass, the most significant bias (−3.16 per cent) was found for a star with a helium enrichment ratio outside the grid range. Moreover, an ∼7 per cent dispersion in age was found when adopting different prescriptions for the surface corrections or shifting the classical observations by ±1σ. The choice of the relative weight given to the classical and seismic constraints also impacted significantly the accuracy and precision of the results. Interestingly, only a few frequencies were required to achieve accurate results on the mass and radius. For the age the same was true when at least one l = 2 mode was considered.

Cunha, M. S. (ORCID:0000000182377343)↗

WE-D-17A-05: Measurement of Stray Radiation Within An Active Scanning Proton Therapy Facility: EURADOS WG9 Intercomparison Exercise of Active Dosimetry Systems

Purpose: Intercomparison of active dosemeters in the measurement of stray radiation at the Trento active-scanning proton therapy facility. Methods: EURADOS WG9 carried out a large intercomparison exercise to test different dosemeters while measuring secondary neutrons within a 230 MeV scanned proton therapy facility. Detectors included two Bonner Sphere Spectrometers (BSS), three tissue equivalent proportional counters (TEPCHawk) and six rem-counters (Wendi II, Berthold, RadEye, a regular and an extended-range Anderson and Braun NM2B counters). Measurements of neutron ambient dose equivalents, H*(10), were done at several positions inside (8 positions) and outside (3 positions) the treatment room while irradiating a water tank phantom with a 10 × 10 × 10 cc field. Results: A generally good agreement on H*(10) values was observed for the tested detectors. At distance of 2.25 m and angles 45°, 90° and 180° with respect to the beam axis, BSS and proportional counters agreed within 30%. Higher differences (up to 60%) were observed at the closest and farthest distances, i.e. at positions where detectors sensitivity, energy, fluence and angular response are highly dependent on neutron spectra (flux and energy). The highest neutron H*(10) value, ∼60 microSv/Gy, was measured at 1.15 m along the beam axis. H*(10) decreased significantly with the distance from the isocenter dropping to 1.1 microSv/Gy at 4.25 m and 90° from beam axis, ∼2 nanoSv/Gy at the entrance of the maze, 0.2 nanoSv/Gy at the door outside the room and below detection limit in the gantry control room and at an adjacent room. These values remain considerately lower than those of passively scattered proton beams. BSS and Hawk unfolded spectra provide valuable inputs when studying the response of each detector. Conclusion: TEPCs and BSS enable accurate measurements of stray neutrons while other rem-meters also give satisfactory results but require further improvements to reduce uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗

Preliminary Results on Bayesian Inverse UQ for OECD/NEA WPNCS Subgroup 14 Benchmark Exercise for Error Recovery and Experimental Coverage

The Organization for Economic Cooperation and Development (OECD) Working Party on Nucelar Criticality Safety (WPNCS) has proposed a benchmark exercise representative of neutronic behavior in criticality experiments. Here, the goal is to develop confidence in data assimilation techniques used to adjust nuclear data. Participants are given synthetic experimental models with associated measured data and asked to estimate the model parameters given the model and measurements as well as provide predictions for separate application models. In this work, we performed data assimilation using Bayesian inverse Uncertainty Quantification (UQ) with machine learning surrogate models to produce posterior parameter distributions for the requested parameters and posterior predictive distributions for the requested responses. Several experimental models are shown to insufficiently inform the posterior parameter distributions for the applications involved. However, given sufficient experimental data, posterior parameter estimates yielded reduced uncertainty in the response predictions of interest while covering the experimental data.

Bayesian Inference↗

Exercise Prevents Weight Gain and Alters the Gut Microbiota in a Mouse Model of High Fat Diet-Induced Obesity

Diet-induced obesity (DIO) is a significant health concern which has been linked to structural and functional changes in the gut microbiota. Exercise (Ex) is effective in preventing obesity, but whether Ex alters the gut microbiota during development with high fat (HF) feeding is unknown. Determine the effects of voluntary Ex on the gastrointestinal microbiota in LF-fed mice and in HF-DIO. Male C57BL/6 littermates (5 weeks) were distributed equally into 4 groups: low fat (LF) sedentary (Sed) LF/Sed, LF/ Ex, HF/Sed and HF/Ex. Mice were individually housed and LF/Ex and HF/Ex cages were equipped with a wheel and odometer to record Ex. Fecal samples were collected at baseline, 6 weeks and 12 weeks and used for bacterial DNA isolation. DNA was subjected both to quantitative PCR using primers specific to the 16S rRNA encoding genes for Bacteroidetes and Firmicutes and to sequencing for lower taxonomic identification using the Illumina MiSeq platform. Data were analyzed using a one or two-way ANOVA or Pearson correlation. HF diet resulted in significantly greater body weight and adiposity as well as decreased glucose tolerance that were prevented by voluntary Ex (p<0.05). Visualization of Unifrac distance data with principal coordinates analysis indicated clustering by both diet and Ex at week 12. Sequencing demonstrated Ex-induced changes in the percentage of major bacterial phyla at 12 weeks. A correlation between total Ex distance and the ΔCt Bacteroidetes: ΔCt Firmicutes ratio from qPCR demonstrated a significant inverse correlation (r 2 = 0.35, p = 0.043). Conclusion: Ex induces a unique shift in the gut microbiota that is different from dietary effects. Microbiota changes may play a role in Ex prevention of HF-DIO.

59 BASIC BIOLOGICAL SCIENCES↗

Report on a Zero-Knowledge Protocol Tabletop Exercise

This report summarizes the discussion and conclusions reached during a table top exercise held at Sandia National Laboratories, Albuquerque on September 3, 2014 regarding a recently described approach for nuclear warhead verification based on the cryptographic concept of a zero-knowledge protocol (ZKP) presented in a recent paper authored by Glaser, Barak, and Goldston. A panel of Sandia National Laboratories researchers, whose expertise includes radiation instrumentation design and development, cryptography, and arms control verification implementation, jointly reviewed the paper and identified specific challenges to implementing the approach as well as some opportunities. It was noted that ZKP as used in cryptography is a useful model for the arms control verification problem, but the direct analogy to arms control breaks down quickly. The ZKP methodology for warhead verification fits within the general class of template-based verification techniques, where a reference measurement is used to confirm that a given object is like another object that has already been accepted as a warhead by some other means. This can be a powerful verification approach, but requires independent means to trust the authenticity of the reference warhead - a standard that may be difficult to achieve, which the ZKP authors do not directly address. Despite some technical challenges, the concept of last-minute selection of the pre-loads and equipment could be a valuable component of a verification regime.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Radiochronometry in the CMX-4 Exercise-Draft

In a recent international exercise, 10 international nuclear forensics laboratories successfully performed radiochronometry on 3 low-enriched uranium oxide samples, providing 12 analytical results using 3 different parent-daughter pairs serving as independent chronometers. The vast majority of the results were consistent with one another and consistent with the known processing history of the materials. In general, for these particular samples, mass spectrometry gave more accurate and more precise analytical results than decay counting measurements. In addition, the concordance of the 235 U- 231 Pa and 234 U- 230 Th chronometers confirmed the validity of the age dating assumption, increasing our confidence in the resulting conclusions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NMSBA - Twist Resist - Rotational Exercise Module

This report contains a summary of the work completed to develop a modular, rotational exercise device. In the report are images, diagrams, and explanations of the efforts contributed to the project since its inception. The purpose of this document is to provide a walk-through of the progress on this project, from the initial design concepts to the final design and work done, so that the customer (Twist Resist), or individuals/firms who work on this project in the future will have a springboard of ideas/concepts to work from.

42 ENGINEERING↗

Mock Inspection Exercise Materials- Example For Training Purposes Only, Version 3

New Mexico Environmental Department (NMED) is providing statewide training to all entities that are currently or expecting to be covered by a National Pollutant Discharge Elimination System (NPDES) Multi-Sector General Permit (MSGP). The purpose of the training is to educate facility personnel on permit requirements and methods to stay compliant with a permit. NMED has invited personnel from Los Alamos National Laboratory Environmental Protection & Compliance – Environmental Compliance Programs to assist with the statewide training by developing training materials and assist NMED in presenting the training sessions. The attached map mock-up and photos are intended as training materials for a mock MSGP routine facility inspection. In this exercise, participants will use the map and photos for a simulated field walk-down of a fictitious facility, the XYZ Widget Company’s Production Complex. Participants will learn elements of storm water flow paths, how to identify potential storm water issues, and document their findings in order to meet permit requirements.

54 ENVIRONMENTAL SCIENCES↗

EURATOM Fast Collar for BWR (EFCB) Field Calibration Exercise

A neutron collar for the measurement of fresh BWR fuel assemblies (EFCB) has been designed and built by Los Alamos National Laboratory (LANL) and the Euratom Safeguards Directorate (Euratom). The design was similar to a previous collar designed for the measurement of fresh PWR assemblies. A key feature of both of these collars is that they operate in fast mode (preventing the return of thermal neutrons into the assembly by means of a cadmium liner) to reduce the effect of burnable poisons on the measurement. The current report describes the results of the field calibration exercise that was carried out at the ENUSA Fuel Fabrication Plant in Juzbado, Spain from May 28 to May 31, 2019.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Savannah River National Laboratory Participation in the International Atomic Energy Agency CPC Interlaboratory Comparison Exercise 2

International Atomic Energy Agency Safeguards Analytical Services (IAEA-SGAS) oversees coordinating the second Controlled Potential Coulometry Quality Control Interlaboratory Comparison (CPC QC ILC) on behalf of the Nuclear Material Laboratory (NML). The purpose of the exercise is to: (1) verify the ability of participating laboratories to measure the Pu concentration in the sample solutions, and (2) estimate the method performance (repeatability and intermediate reproducibility). Sample shipping coordination was performed by IAEA-SGAS. The test sample is a plutonium nitrate solution (estimated molarity of 3-5 M), delivered in two PTFE screw-capped quartz ampoules. Each participating laboratory is to receive two ampoules. Each ampoule holds approximately 8 mL of solution containing approximately 10 mg Pu/g. The gross weights of the ampoules were provided. The test sample is assumed to have an iron content below the level of significance for the CPC. The isotopic composition of the plutonium test sample was provided; however, no analysis date was provided. In addition, IAEA-SGAS provided analytical instructions to participants. On September 20, 2022, SRNL received the samples sent by IAEA-SGAS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

IER 538: International Dosimetry Intercomparison Exercise with Godiva-IV [Slides]

Presentation on International Dosimetry Intercomparison Exercise with Godiva-IV. This presentation details Department of Energy (DOE) requirements and irradiation. Graphs show Neutron dose conversion factors, Neutron dose characterization, and Photon dose characterization. Results of 2m, 3m, and 4m tests are then compared to DOE standards. Findings show photon dose measurements were limited by instrumentation not available. Additionally, there has been a turnover of staff in dosimetry. However, funding is being provided for Universal Nuclear Accident Dosimeter (U-NAD).

61 RADIATION PROTECTION AND DOSIMETRY↗