Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

10 CFR 830 Major Modification Determination for the ATR Diesel Bus (E-3) and Switchgear Replacement

Near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent subprojects. The first project, subject of this determination, will replace the existent diesel-electrical bus (E-3) and associated switchgear. More specifically, INL proposes transitioning ATR to 100% commercial power with appropriate emergency backup to include: • Provide commercial power as the normal source of power to the ATR loads currently supplied by diesel-electric power. • Provide backup power to the critical ATR loads in the event of a loss of commercial power. • Replace obsolescent critical ATR power distribution equipment, e.g., switchgear, transformers, motor control centers, distribution panels. Completion of this and two other age-related projects (primary coolant pump and motor replacement and emergency firewater injection system replacement) will resolve major age related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues make the project a major modification: 1. Evaluation Criteria #2 (Footprint change). The addition of a new PC-4 structure to the ATR Facility to house safety-related SSCs requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., structural qualification, fire suppression) to ensure no adverse impacts to the safety-related functions of the housed equipment. 2. Evaluation Criteria #3 (Change of existing process). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps requires careful attention and analysis to ensure it meets a project primary object to maintain or reduce CDF and does not negatively affect the efficacy of the currently approved strategy. 3. Evaluation Criteria #5 (Create the need for new or revised safety SSCs). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps, based on the pre-conceptual design, will require the addition of two quick start diesel generators, their associated power coordination/distribution controls, and a UPS to the list of safety-related SSCs. Similarly to item 1 above, the addition of these active SSCs to the list of safety-related SSCs and replacement of the E-3 bus requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., seismic qualification, isolation of redundant trains from common fault failures) to ensure no adverse impacts to the safety-related functions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchically porous electrospun carbon nanofiber for high-rate capacitive deionization electrodes

Capacitive deionization (CDI) is a promising technology that has gained interest for the desalination of brackish water. Hierarchically porous carbons are commonly used as electrodes for CDI due to their high surface areas and controlled pore size distributions that maximize ion adsorption capacity and rate. Electrospinning is an effective way of generating carbon nanofibers with high inter-fiber macroporosity that can be further modified to improve surface area, total pore volume, and pore size distribution. This work describes the use of sacrificial mesopore formers in tandem with a micropore etching technique to induce hierarchical porosity in electrospun fibers. Mesopores are formed via the dissolution of silica nanoparticles that are introduced into the fibers during the electrospinning step. After mesopore formation, micropores are etched into the resulting surface through KOH impregnation and thermal activation. This sequential technique creates a hierarchical network of pores from the inherent macroporosity of the fiber network, to the mesopores, and finally micropores to simultaneously maximize surface area and accessibility. Micropore formation is optimized to maximize specific surface area while maintaining physical integrity of the fibers. Further, the combination of mesopores and micropores enables fast ion adsorption rates and capacity. Carbon fiber electrodes fabricated in this method achieve specific surface areas exceeding 1400 m 2 g -1 , with pore volumes exceeding 1.0cc g -1 . The pore size distributions are highly controlled, with 80% of total pore volume coming from pores <20nm in radius. In 500 ppm constant voltage CDI tests, these fiber electrodes obtain a salt adsorption capacity of over 14 mg g -1 at a salt adsorption rate of ~4mg g -1 min -1 , showcasing the high capacity matched with high rate of these easily fabricated, inexpensive materials.

36 MATERIALS SCIENCE↗

Gravity-driven controls on fluid and carbonate precipitation distributions in fractures

Abstract Many challenges related to carbon-dioxide ( $$\hbox {CO}_2$$ CO 2 ) sequestration in subsurface rock are linked to the injection of fluids through induced or existing fracture networks and how these fluids are altered through geochemical interactions. Here, we demonstrate that fluid mixing and carbonate mineral distributions in fractures are controlled by gravity-driven chemical dynamics. Using optical imaging and numerical simulations, we show that a density contrast between two miscible fluids causes the formation of a low-density fluid runlet that increases in areal extent as the fracture inclination decreases from 90 $$^\circ$$ ∘ (vertical fracture plane) to 30 $$^\circ$$ ∘ . The runlet is sustained over time and the stability of the runlet is controlled by the gravity-driven formation of 3D vortices that arise in a laminar flow regime. When homogeneous precipitation was induced, calcium carbonate covered the entire surface for horizontal fractures (0 $$^\circ$$ ∘ ). However, for fracture inclinations greater than 10 $$^\circ$$ ∘ , the runlet formation limited the areal extent of the precipitation to less than 15% of the fracture surface. These insights suggest that the ability to sequester $$\hbox {CO}_2$$ CO 2 through mineralization along fractures will depend on the fracture orientation relative to gravity, with horizontal fractures more likely to seal uniformly.

54 ENVIRONMENTAL SCIENCES↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low power, scalable multichannel high voltage controller

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

42 ENGINEERING↗

Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders

This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different case studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.

distribution system modeling↗

Design and Stability of Load-Side Primary Frequency Control in Power Systems

We present a systematic method to design ubiquitous continuous fast-acting distributed load control for primary frequency regulation in power networks, by formulating an optimal load control (OLC) problem where the objective is to minimize the aggregate cost of tracking an operating point subject to power balance over the network. We prove that the swing dynamics and the branch power flows, coupled with frequency-based load control, serve as a distributed primal-dual algorithm to solve OLC. We establish the global asymptotic stability of a multimachine network under such type of load-side primary frequency control. These results imply that the local frequency deviations on each bus convey exactly the right information about the global power imbalance for the loads to make individual decisions that turn out to be globally optimal. Simulations confirm that the proposed algorithm can rebalance power and resynchronize bus frequencies after a disturbance with significantly improved transient performance.

Zhao, CH↗

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale distribution system of 11,000 nodes, the DERMS software controller, and 90 power hardware photovoltaics (PVs) and battery inverters. The applied DERMS algorithm is designed based on a realtime optimal power flow algorithm and implemented with acceleration design that performs fast dispatch of simulated PVs and real physical hardware DER devices every 4 seconds.

DERMS↗

Per-page control of physical address space distribution among memory modules

Systems, apparatuses, and methods for implementing per-page control of physical address space distribution among memory modules are disclosed. A computing system includes a plurality of processing units coupled to a plurality of memory modules. A determination is made as to which physical address space distribution granularity to implement for physical memory pages allocated for a first data structure. The determination can be made on a per-data-structure basis (e.g., file, page, block, etc.) or on a per-application-basis. A physical address space distribution granularity is encoded as a property of each physical memory page allocated for the first data structure, and physical memory pages of the first data structure distributed across the plurality of memory modules based on a selected physical address space distribution granularity. Page table entries (PTEs) may be annotated with the selected physical address space distribution granularity, using an addressing mapping granularity (AMG) field of a page table entry, where the granularity may be, for example, a fine-grain distribution granularity or a coarse-grain distribution granularity.

Jayasena, Nuwan S.↗

Distributed reinforcement learning and consensus control of energy systems

Disclosed herein are methods, systems, and devices for utilizing distributed reinforcement learning and consensus control to most effectively generate and utilize energy. In some embodiments, individual turbines within a wind farm may communicate to reach a consensus as to the desired yaw angle based on the wind conditions.

King, Jennifer Rose Rose↗

Real-time simulator and controller of power system using distributed data streaming server

Systems and methods for simulating and controlling a power system in real time, using a controller, are provided. The controller includes a simulation layer to simulate an operation of the power system, a disturbance generation layer to provide data to the simulation layer to disturb the simulated operation of the power system, an application layer to display the simulated operation of the power system and generate a control signal to control, based on the simulated operation of the power system, at least one element of the power system, and a distributed data streaming server (D2S2) to allow interoperability among the simulation layer, the disturbance layer, and the application layer.

Li, Fangxing↗

Geometric Analysis Based Double Closed-loop Iterative Learning Control of Output PDF Shaping of Fiber Length Distribution in Refining Process

In order to improve the pulp quality and to reduce the energy consumption, the fiber length distribution (FLD) is generally employed as one of the important technological indexes in the refining process. Considering that the traditional mean and variance of fiber length are unable to adequately characterize the non-Gaussian distribution properties, this paper proposes a novel geometric analysis based double closed-loop iterative learning control (ILC) method for probability density function (PDF) shaping of output FLD in the refining process. Primarily, a RBF neural network (NN) with Gaussian-type is utilized to approximate the square root PDF in the inner loop, where the RBF basis function parameters (center and width) are tuned between any two adjacent batches by using an ILC law, and the subspace identification method can be applied to establish the state-space model of weight vector. Then, for the sake of accelerating the convergence rate of the closed-loop sysyem, a geometric analysis based ILC method is adopted in the outer loop. Lastly, both simulation and experiments demonstrate the effectiveness and practicability of the proposed approach.

42 ENGINEERING↗

A Zonal Volt/VAR Control Mechanism for High PV Penetration Distribution Systems

This paper presents a zonal Volt/VAR control scheme for regulating voltage in unbalanced 3-phase distribution systems using inverter-based resources (IBR). First, the dependency between nodal voltage changes and IBR reactive power injections is derived via voltage sensitivity studies. Then, a fast-incremental clustering method is used to divide the distribution circuit into weakly-coupled zones based on correlations between nodal voltage sensitivities. The weak-coupling allows the voltage to be regulated independently within each zone using a rule-based voltage controller to dispatch IBR for voltage corrections. Simulation results on actual distribution feeder show that the proposed zone-based Volt/VAR control method maintains system voltages within their operational limits while reducing the runtime of the Volt/VAR controller from tens of second to a couple of milliseconds compared with centralized, optimization-based Volt/VAR control methods.

Alrushoud, Asmaa↗

Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) Research: Controls

Advanced Turbine Control for Distributed Wind Deployments: The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) research initiative is funded by the U.S. Department of Energy’s Wind Energy Technologies Office and led by researchers at the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (Sandia). The initiative’s controls research seeks to expand the benefits from distributed wind energy assets beyond solely providing low-cost power directly to consumers. To make these turbines operate more effectively, there is a need for more advanced ways to control them—allowing power companies, businesses, and energy consumers to take advantage of some of the unique technical characteristics of wind energy.

wind, Microgrids, Infrastructure, Resilience, Adva↗