Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Investigating the time dependence of neutron-proton equilibration using molecular dynamics simulations

Neutron-proton equilibration has previously been studied experimentally in dynamically deformed nuclei in heavy ion collisions [Phys. Rev. Lett. 118, 062501 (2017); Phys. Rev. C 95, 044604 (2017)] using the NIMROD detector array at the Cyclotron Institute at Texas A&M University. Results indicated the composition of the two heaviest fragments originating from the excited projectile-like fragment evolved exponential with respect to their orientation angle to be more similar. Constrained Molecular Dynamics and Antisymmetrized Molecular Dynamics simulations were performed for different formulations of the density dependence of the asymmetry energy term of the nuclear equation of state. The simulations are compared to experimental results, which indicate a better agreement with a softer interaction in the nuclear equation of state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using DAPPER to extract the photon strength function of 58 Fe using the inverse Oslo and shape methods

The photon strength function of 58 Fe has been extracted using both the Oslo and Shape methods from particle–γ coincidence data measured using the Detector Array for Photons, Protons, and Exotic Residues, which probes nuclei utilizing (d,p) reactions in inverse kinematics. Four particle–γ coincidence matrices, each constructed with different treatments of the γ–ray energies, are explored in order to observe the impact on the resulting nuclear level density and photon strength. The final photon strength function reported is found to agree well with previous Oslo measurements of other iron isotopes. Systematic uncertainties are included, using different model parameters and their reported errors to perform the Oslo method normalization. The model-independent Shape method is explored and the functional form of the photon strength function obtained is in agreement with the Oslo method results. A low-energy enhancement is not reported for 58 Fe in this work given possible subtraction issues originating from strongly populated states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Multiparticle-hole excitations in nuclei near N = Z = 20: $^{41}$K

This experimental study of high-spin structure near the N = Z = 20 region focuses on 41 K and also reports three newly observed γ transitions in 41 Ca from the same reaction. High-spin states were populated using the 26 Mg( 18 O, p2nγ) 41 K and 26 Mg( 18 O, 3nγ) 41 Ca reactions at a beam energy of 50 MeV at the Florida State University John D. Fox Superconducting Linear Accelerator Laboratory, employing the FSU high-purity germanium detector array. The level scheme of 41 K was extended to 12325 keV, possibly up to J π = 25/2 − or 27/2 + , by means of 25 new γ-ray transitions, and that of 41 Ca to 9916 keV. Linear polarization and angular-distribution measurements were used to provide spin and parity information for several states in the 41 K decay scheme. The results are compared with spsdpf cross-shell shell-model calculations using the FSU interaction. Configurations involving zero or one nucleon promoted from the sd to the fp shell reproduce the energies of many known states reasonably well, while multi-particle excitations reveal a more complex interplay of single-particle motion, collective pairing, and deformation, posing an interesting challenge for future theoretical work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton branching ratios in 22 Mg for X-ray bursts

Here, decay protons from 22 Mg energy levels populated through a previously reported 24 Mg(p, t) 22 Mg transfer reaction (Chae et al. in Phys Rev C 79:055804, 2009) have been analyzed for proton branching ratios as a follow-up analysis. The measurement was performed at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory by utilizing 41-MeV proton beams and 24 Mg solid targets. Decay protons and reaction tritons were simultaneously detected with a silicon detector array. By investigating the 24 Mg(p, t) 22 Mg*(p) 21 Na channels, the proton branching ratios of five 22 Mg excited states were obtained. The measured branching ratios provide constraints on the proton partial widths of the populated 22 Mg levels, which have implications for X-ray burst nucleosynthesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetimes of excited states in $^{16}$C as a benchmark for ab initio developments

Lifetimes of higher-lying states ($2_2^+$ and $4_1^+$) in 16 C have been measured, employing the Gammasphere and Microball detector arrays, as key observables to test and refine ab initio calculations based on interactions developed within chiral Effective Field Theory. The presented experimental constraints to these lifetimes of $\tau ({2_2^+}) = [244, 446]\,~\textrm{fs}$ and $\tau ({4_1^+}) = [1.8, 4]\,~\textrm{ps}$, combined with previous results on the lifetime of the $2_1^+$ state of 16 C, provide a rather complete set of key observables to benchmark the theoretical developments. We present No-Core Shell-Model calculations using state-of-the-art chiral 2- (NN) and 3-nucleon (3N) interactions at next-to-next-to-next-to-leading order for both the NN and the 3N contributions and a generalized natural-orbital basis (instead of the conventional harmonic-oscillator single-particle basis) which reproduce, for the first time, the experimental findings remarkably well. The level of agreement of the new calculations as compared to the CD-Bonn meson-exchange NN interaction is notable and presents a critical benchmark for theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of collective rotational bands in neutron-rich 142 La and the study of octupole/triaxial deformations in 142,143 La

Collective rotational bands were observed for the first time in neutron-rich odd–odd 142 La by means of γ-γ-γ and γ-γ-γ-γ coincidence measurements of prompt fission γ rays from 252 Cf using multi-detector array Gammasphere. Similarity between the yrast band of 142 La and those of neighboring 144 La, 144 Ce was found and interpreted as quasiparticle excitations. Here, PES calculations suggested triaxial deformation for the ground state of 142La. Considerable triaxial and near zero octupole deformations were deduced for the yrast band of 142 La by the TRS model calculations. The band-crossing observed in the yrast band of 142 La was interpreted to be caused by alignment of the (h 11/2 ) 2 proton pair, and the crossing frequency was best reproduced by the TRS calculations taking into account triaxial deformations. In contrast to the interpretations for the band crossing of 142 La, alignments of the (i 13/2 ) 2 neutron pair were found to be responsible for the band-crossing of the yrast band in the neighboring even-N 143 La, and triaxial degree of freedom was found to play a more significant role than octupole deformations in the nucleus, although its β 3 values deduced are large.

142La↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Neutron Radiography Simulations

Conclusions: Elements other than detector array can heavily impact performance; Must consider a variety of alterations to an imaging array to determine an optimal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of TATB by uHPLC-DAD (V.2.2)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of TATB by HPLC-DAD (V.1.4)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD). This procedure is also applicable for the detection of some impurities present in TATB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗