EHD analysis of and experiments on pumping Leningrader seals
Analysis and design charts have been generated to provide design data for Pumping Leningrader Reciprocating Rod Seals. The analytical treatment divides the seal into three regions: an inlet zone, induced with the use of an expansion ring, a contact zone, and an exit zone. Complete solutions have been obtained by matching elasticity equations with hydrodynamic theory. Experiments, although of a limited nature, did demonstrate the ability of the seal design analysis to provide viable seals.