Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Dose rate effects in MOS microcircuits

Three read/write random access memories, AM91L24, HM1-6514, and MWS 5114, were subjected to total dose irradiation at three dose rates, with electrical testing after each increment of dosage. Annealing measurements were performed after the radiation tests were completed. The AM91L24 showed a strong dose rate effect and substantial post-irradiation annealing of radiation-induced damage. The dose rate effect was that a lower dose rate produced less net damage than an eqivalent total dose applied at a higher rate. The HM1-6514 showed essentially no dose rate effect and no annealing damage, and the MWS 5114 exhibited a moderate effect with some annealing. It was concluded that dose rate is an important parameter in radiation test procedures for MOS microcircuits and that annealing measurements may be important evaluation aids for such tests.

Cleveland, D. G.↗

An overview of medical-biological radiation hazards in earth orbits

The radiation exposure of crew members on space missions in LEO and GEO is evaluated in a general review. The radiation environment is characterized, taking the trapped radiation belts, solar flares, Galactic and solar cosmic rays, and secondary radiation into account and emphasizing the increased dosages produced by transient phenomena such as solar flares. The biological effects of space radiation in the individual cells, on the body as a whole, and on critical organs are summarized, and the exposure limits and shielding specifications (for spacecraft and for EVA suits) currently used by US mission planners are reviewed. For GEO, 4-g/sq cm Al-equivalent shielding is considered adequate under normal conditions, making EVA in this volatile environment questionable; for anomalously large solar flares, emergency shelter within 10-g/sq cm walls or the capability to retreat to a lower orbit is necessary.

Stauber, M. C.↗

Contradictory results in interferon research

Several reports on immunologically related interferon research, both in the areas of basic science and clinical research, are briefly reviewed, and it is noted that in many cases the results obtained are contradictory. It is argued, however, that the contradictory results are not surprising since interferon is a biological response modifier and has been known to produce opposite results even when the same interferon prepartion is used. It is emphasized that dosage, timing, route, and other experimental conditions are essential factors in planning immunological studies with interferon. Careful planning of future experiments with interferon should be required to prevent the possible generation of effects that are opposite to those expected.

Sonnenfeld, G.↗

Effects of interferon on antibody formation

Studies of the effects of interferon on primary and secondary antibody responses and of the relationship of interferon to other cytokines, or cell products, are presented. Dosage- and timing-dependent immunoenhancing and immunosuppressive activities of interferon are documented for mouse spleen cell cultures and for mice infected with murine hepatitis virus (MHV-3). A possibility that altered interferon production might lead to immunopathological disorders, such as lupus erythematosus, AIDS, arthritis, etc., is discussed. Latest technological developments are presented that indicate that interferon does apparently play a major role in the regulation of antibody responses.

Sonnenfeld, G.↗

Radiation effects on high performance polymers

Polymer matrix materials are candidates for use in large space antennas and space platforms that may be deployed in geosynchronous orbit 22,500 miles above the Earth. A principal concern is the long term effects of an environment that is hostile to organic polymers, including high energy electromagnetic radiation, bombardment by charged particles, and large abrupt changes in temperature. Two polyarylene ethers which might be utilized as models for polymers in space applications were subjected to dosages of 70 keV electrons up to 3.4 x 10 to the 10th power rad. The irradiated films were then examined to determine the effects of the high-energy electrons.

Orwoll, R. A.↗

Cytogenetic analyses of peripheral lymphocytes subjected to simulated solar flare radiation

Solar flare protons share many radiological health characteristics of the inner Van Allen Belt protons, and both types of radiation pose serious dangers to a number of missions planned. It is appropriate to evaluate crew dose determination procedures in terms of the type of radiation responsible for the major part of the projected exposure, i.e., protons in the neighborhood of 100 MeV. Monitoring chromosome abnormalities in peripheral lymphocytes is one method to determine an individual's accumulated radiation dosage. Cell culture and harvest is a relatively simple procedure and is well within the capabilities of a station health facility, but the evaluation of prepared microscopic slides is a time consuming and subjective procedure. This project is part of an effort to demonstrate the utility of automated image processing and evaluation procedures in expediting dose evaluation. The initial goal of this project is to produce a set of reference chromosome spreads produced from control lymphocytes and from lymphocytes exposed in whole blood to protons or gamma rays. The results of manual and automated aberration scoring will ultimately be compared to test for systematic differences between the two evaluation procedures and between the two radiation qualities. Proton irradiations are performed at the University of Texas Health Science Center at Houston Cyclotron Facility. Proton dosimetry is supplemented by TLD packets from and by assay of short-lived proton activation products in the irradiation blood samples.

Prichard, H. M.↗

Radiation and temperature effects on the time-dependent response of T300/934 graphite/epoxy

A time-dependent characterization study was performed on T300/934 graphite/epoxy in a simulated space environment. Creep tests on irradiated and nonirradiated graphite/epoxy and bulk resin specimens were carried out at temperatures of 72 and 250 F. Irradiated specimens were exposed to dosages of penetrating electron radiation equal to 30 years exposure at GEO-synchronous orbit. Radiation was shown to have little effect on the creep response of both the composite and bulk resin specimens at 72 F while radiation had a significant effect at 250 F. A healing process was shown to be present in the irradiated specimens where broken bonds in the epoxy due to radiation recombined over time to form cross-links in the 934 resin structure. An analytical micromechanical model was also developed to predict the viscoelastic response of fiber reinforced composite materials. The model was shown to correlate well with experimental results for linearly viscoelastic materials with relatively small creep strains.

Yancey, Robert N.↗

Effects of charged particles on the surfaces of the satellites of Uranus

Measurements of the ion and electron fluxes in the Uranian magnetosphere made by the low-energy charged-particle (LECP) instrument on the Voyager 2 spacecraft are used to discuss possible particle-induced modifications of the moons and rings of Uranus. The energy spectra of the orbit-integrated particle dosages expected on the major moons are derived from the LECP measurements of particle intensities and pitch-angle distributions. Laboratory-derived results on charged-particle-induced chemical and physical modifications of H2O, CH4, CO, and CO2 ions are used. The erosion rates of water ice and the darkening of organic ices on the surfaces of the moons are estimated from the orbit-integrated fluxes. Significant darkening of fresh organic ices to depths of the order of 1 micron is expected to occur for times as short as a few thousand years. Darkening at deeper depths will occur at increasingly longer times. The implications of these results for the interpretation of remote-sensing data are discussed.

Lanzerotti, L. J.↗

Effects of scopolamine and dextroamphetamine on human performance

The effects of two drugs used to prevent symptoms of motion sickness in the operational environment were examined in this study of human performance as measured by computer-based tests of cognitive and psychomotor skills. Each subject was exposed repetitively to five tests: symbol-digit substitution, simple reaction time, pattern recognition, digit span memory, and pattern memory. Although there have been previous reports of decreases in human performance in similar testing with higher dosages of scopolamine or dextroamphetamine, no significant decrements were observed with the operational-level combined dose used in this study (0.4 mg oral scopolamine and 5.0 mg oral dextroamphetamine.) The controversy over the use of combination drug therapy in this environnment is discussed along with the indications for further research based on the findings.

Schmedtje, John F., Jr.↗

Standard Method For Radiation Tests Of Liquids

Simple procedure provides standard method for radiation tests of liquids. Assures identical handling and dosage so data from different test laboratories compared reliably. Pair of glass vials, joined by frangible neck and equipped with valves, used. Third vial also used. Filled with control specimen and not irradiated. Developed for measuring properties of liquids for use in radiation-resistant liquid-dielectric capacitors, procedure used for any of variety of liquids proposed for use in high-radiation environment - in x-ray and particle-accelerating machines and nuclear reactors, for example.

Bouquet, Frank L.↗

Radiation safety in commercial air traffic - A need for further study

The problem of radiation exposure of crewmembers in high altitude supersonic commercial aircraft is addressed. As a result of recent changes in the quality factors for radiological protection, it is found that worst case estimates of radiation exposure are now well above the exposure limits of the general population, and a reassessment of radiation impact on commercial aviation is needed, if the proposed quality factors are adopted. Calculations are presented from a study on neutron dosage equivalent rates. It is shown that a crew flying at altitudes near 13 km (43,000 ft) for 40 hr/mo would receive exposure levels of 47-75 Sv/yr, and it is suggested that such crewmembers be considered as radiation workers, rather than general population members. However, since present exposure estimates need to be improved, and the maximum permissible dose limits are currently under revision, the final exposure limits are, as yet, unclear, suggesting the need for further study to clarify the work status of commercial aircrews.

Wilson, John W.↗

Photoreflectance Study of Boron Ion-Implanted (100) Cadmium Telluride

Ion implanted (100) cadmium telluride was studied using the contactless technique of photoreflectance. The implantations were performed using 50- to 400-keV boron ions to a maximum dosage of 1.5 x 10(16)/sq cm, and the annealing was accomplished at 500 C under vacuum. The spectral measurements were made at 77 K near the E(0) and E(1) critical points; all the spectra were computer-fitted to Aspnes' theory. The spectral line shapes from the ion damaged, partially recovered and undamaged, or fully recovered regions could be identified, and the respective volume fraction of each phase was estimated.

Amirtharaj, P. M.↗

Differential effects of scopolamine and amphetamine on microcomputer-based performance tests

The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.

Kennedy, Robert S.↗

Survival of epiphytic bacteria from seed stored on the Long Duration Exposure Facility (LDEF)

This study was designed to determine the survival of microorganisms exposed to the relatively harsh conditions found in low Earth orbit (LEO). Seed of corn, sunflower, canteloupe, zucchini, bean, pea, and pumpkin cultivars were packaged in two 18 x 2.5 cm aluminum tubes; wall thickness for each tube was 1.33 mm. One seed tube was attacked to payload M0006, tray C-2; a second tube was stored at room temperature in a lab on Earth. Five lithium fluoride thermoluminescent dosimetry wafers (TLD-100 wafers) were placed in each aluminum tube. The total mean dosages for flight and ground-control TLD wafers were 210.0 and 0.9 rads, respectively. Seeds were washed for 2 hrs in a phosphate buffered saline solution. Bacteria were isolated by plating samples of the seed-washings onto dilute tryptic soy agar. Pure isolates of morphologically distinct bacteria were obtained by standard microbiological procedures. Bacteria were grouped according to colony-type and preliminary identification was completed using a fatty-acid analysis system. Bacillus spp. were the primary microoganisms that survived on seed during the experiment. Bacterial diversity and relative abundance were similar for the ground flight seed. Bacillus subtilus, B. pumilus, B. licheniformis, B. polymyxa, B. megaterium, and B. pabuli were isolated most frequently. Members of the genera Kurthia, Listeria, Micrococcus, and Arthrobacter were also isolated from flight and ground control seed. Results support the hypothesis that terrestrial microorganisms can survive long periods of time in the relatively harsh LEO environment.

Schuerger, Andrew C.↗

Metabolism of Nonessential N15-Labeled Amino Acids and the Measurement of Human Whole-Body Protein Synthesis Rates

Eight N-15 labeled nonessential amino acids plus (15)NH4Cl were administered over a 10 h period to four healthy adult males using a primed-constant dosage regimen. The amount of N-15 excreted in the urine and the urinary ammonia, hippuric acid, and plasma alanine N-15 enrichments were measured. There was a high degree of consistency across subjects in the ordering of the nine compounds based on the fraction of N-15 excreted (Kendall coefficient of concordance W = 0.83, P is less than 0.01). Protein synthesis rates were calculated from the urinary ammonia plateau enrichment and the cumulative excretion of N-15. Glycine was one of the few amino acids that gave similar values by both methods.

Stein, T. P.↗

Techniques for determining total body water using deuterium oxide

The measurement of total body water (TBW) is fundamental to the study of body fluid changes consequent to microgravity exposure or treatment with microgravity countermeasures. Often, the use of radioactive isotopes is prohibited for safety or other reasons. It was selected and implemented for use by some Johnson Space Center (JCS) laboratories, which permitted serial measurements over a 14 day period which was accurate enough to serve as a criterion method for validating new techniques. These requirements resulted in the selection of deuterium oxide dilution as the method of choice for TBW measurement. The development of this technique at JSC is reviewed. The recommended dosage, body fluid sampling techniques, and deuterium assay options are described.

Bishop, Phillip A.↗

A very high speed lossless compression/decompression chip set

A chip is described that will perform lossless compression and decompression using the Rice Algorithm. The chip set is designed to compress and decompress source data in real time for many applications. The encoder is designed to code at 20 M samples/second at MIL specifications. That corresponds to 280 Mbits/second at maximum quantization or approximately 500 Mbits/second under nominal conditions. The decoder is designed to decode at 10 M samples/second at industrial specifications. A wide range of quantization levels is allowed (4...14 bits) and both nearest neighbor prediction and external prediction are supported. When the pre and post processors are bypassed, the chip set performs high speed entropy coding and decoding. This frees the chip set from being tied to one modeling technique or specific application. Both the encoder and decoder are being fabricated in a 1.0 micron CMOS process that has been tested to survive 1 megarad of total radiation dosage. The CMOS chips are small, only 5 mm on a side, and both are estimated to consume less than 1/4 of a Watt of power while operating at maximum frequency.

Venbrux, Jack↗

Martian regolith as space radiation shielding

Mars exploration crews will be exposed to such high radiation dosages in route from earth that as to sharply reduce the allowable dose they should receive while on the Martian surface. An account is presently given of the possibility of using Martian regolith as crew shielding to maintain very low short-term dose limits. NASA-Langley's nucleon and heavy-ion transport computer codes are used to predict the propagation and interaction of the free-space nucleons and heavy ions through the Martian atmosphere and then through various thicknesses of regolith. The largest reduction in dose occurs in the first 15-20 cm of regolith material.

Simonsen, L. C.↗