Robust Independent Validation of Experiment and Theory: Rivet version 3

First released in 2010, the Rivet library forms an important repository for analysis code, facilitating comparisons between measurements of the final state in particle collisions and theoretical calculations of those final states. We give an overview of Rivet's current design and implementation, its uptake for analysis preservation and physics results, and summarise recent developments including propagation of MC systematic-uncertainty weights, heavy-ion and ep physics, and systems for detector emulation. In addition, we provide a short user guide that supplements and updates the Rivet user manual.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A pressurized argon gas TPC as DUNE near detector

DUNE is a new international experiment for neutrino physics and nucleon decay searches. It will consist of two detectors, about 1300 km apart, exposed to a multi-megawatt neutrino beam that will be built at Fermilab. One of the two detectors will be installed several hundred meters downstream of the neutrino production point with the primary role of characterising the energy spectrum and composition of the beam as well as performing precision measurements of neutrino cross sections. For the design of this so-called near detector, the DUNE Collaboration is considering, among other technologies, a pressurized argon gas time projection chamber. Such a detector, thanks to its low density and low detection thresholds, would allow the detailed measurement in argon of nuclear effects at the neutrino interaction vertex, which are considered at present one of the most important sources of systematic uncertainty for neutrino oscillation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smart pixel sensors: towards on-sensor filtering of pixel clusters with deep learning

Highly granular pixel detectors allow for increasingly precise measurements of charged particle tracks. Next-generation detectors require that pixel sizes will be further reduced, leading to unprecedented data rates exceeding those foreseen at the High- Luminosity Large Hadron Collider. Signal processing that handles data incoming at a rate of $\mathcal{O}$(40 MHz) and intelligently reduces the data within the pixelated region of the detector at rate will enhance physics performance at high luminosity and enable physics analyses that are not currently possible. Using the shape of charge clusters deposited in an array of small pixels, the physical properties of the traversing particle can be extracted with locally customized neural networks. In this first demonstration, we present a neural network that can be embedded into the on-sensor readout and filter out hits from low momentum tracks, reducing the detector's data volume by 57.1%–75.7%. The network is designed and simulated as a custom readout integrated circuit with 28 nm CMOS technology and is expected to operate at less than 300 μW with an area of less than 0.2 mm 2 . The temporal development of charge clusters is investigated to demonstrate possible future performance gains, and there is also a discussion of future algorithmic and technological improvements that could enhance efficiency, data reduction, and power per area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing modern measurements of the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C excitation function with previous values

A possible means of active interrogation of special nuclear materials is detection of signature emissions following induced photofission. This method requires a probe gamma-ray beam to induce the photofission. The {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction is a candidate for the source of this probe beam. The reaction is prolific and the produced 15.1 MeV gamma-ray is close to a photofission cross-section peak for {sup 235,238}U and {sup 238,239}Pu. In order to model an active interrogation system using the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction as a source probe an accurate value for its differential crosssection must be included in data libraries. Measurements of the differential cross-section for the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction have been carried out with a BGO detector and found to differ from previous measurements reported by Kavanagh (1958) and Kuan (1964). The discrepancy in the measurements may be explained by examining the detector response function used by Kavanagh and presumably Kuan to that modeled with MCNP5. A comparison of the MCNP5 and Kavanagh detector response functions normalized to the 15.1 MeV gamma-ray peak pulse height shows a factor of approximately 1.7 difference in integrated counts. Applying this correction to the differential cross-section previously reported by Kuan brings the values into agreement, within uncertainties, to the more recent measurements. The evaluation of the detector response function for the 15.1 MeV gamma-ray signal in the NaI detector reported by Kavanagh to that modeled by MCNP5 is shown. This result is applied to the comparison of recent measurements on the {sup 11}B(d,n{gamma}{sub 15.1}){sup 12}C reaction differential cross-section to those previously reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

Detector Noise Susceptibility Issues for the Future Generation of High Energy Physics Experiments

The front-end electronics (FEE) noise characterization to electromagnetic interference and the compatibility of the different subsystems are important topics to consider for the LHC calorimeter upgrades. A new power distribution scheme based on switching power converters is under study and will define a noticeable noise source very close to the detector's FEE. Knowledge and experience with both FFE noise and electromagnetic compatibility (EMC) issues from previous detectors are important conditions to guarantee the design goals and the good functionality of the upgraded LHC detectors. This paper shows an overview of the noise susceptibility studies performed in different CMS subdetectors. The impact of different FEE topologies in the final sensitivity to electromagnetic interference of the subsystem is analyzed and design recommendations are presented to increase the EMC of the detectors to the future challenging power distribution topologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of SiPM physics parameters down to cryogenic temperatures and for a bio-medical application

Silicon PhotoMultiplier (SiPM) detector has become a suitable visible light/photon detector for many applications like high energy physics and neutrino experiments, fluorescence detection, bio-photonics and medical imaging. The first part of my thesis was oriented to the studies of SiPM physics parameters as a function of temperature. Particularly, recent KETEK devices (year 2015) with different technological characteristics like p/n and n/p junctions, with and without trench technology, and different widths of epitaxial layer were studied in the temperature range from 308.15 K (+35°C) down to 238.15 K (-35°C). In addition, the Hamamatsu devices from 2011 production run as well as new devices from 2015 year, with improved technological characteristics inducing a reduced noise, were investigated in a wider temperature range from 318.15 K (+45°C) down to 98.15 K (-175°C). For these purposes, I participated to the design, installation, commissioning and calibration of a cryogenic experimental setup dedicated to electrical, optical and temperature studies of SiPM devices. Also, I have developed an automatic analysis procedure able to handle in a short time an impressive quantity of experimental data (i.e. tens of Gb/device) and to give a precise and fast information on main SiPM parameters and their temperature dependence. I have also developed a physical modeldescribing the DC I-V curves of SiPM detectors at different temperatures. The proposed model fits well the shape of IV curve in a very large currents range from 10⁻¹² A up to 10⁻⁵ A over the full working range of various devices. Consequently, the IV model can be used as a simple and fast method for determination of SiPM parameters like breakdown voltage VBD, the shape of Geiger triggering probability PGeiger as a function of Vbias as well as the Vbias working range. The comparison of these parameters with those calculated from AC measurements and analyzed by the automatic procedure showed a good agreement. The second part of my thesis was oriented to the study of SiPM devices and their physical parameters required to build a prototype of betasensitive intracerebral probe. Such probe is dedicated to measure the local concentration of radiolabeled molecules on awake and freely moving animal and to study new animal models of human disorders (neurodegenerative diseases, tumor growth, and neuropsychiatric disorders). It is composed of small size, low-noise SiPM device coupled to a scintillating fiber and readout by a dedicated miniaturized low-power consumption electronics. Three SiPM devices have been chosen as the most adapted for our application: two small KETEK devices of 0.5×0.5 mm² size (with and without optical trenches, specially developed by KETEK to fulfill our requirements) and a standard Hamamatsu device of 1.3×1.3 mm² size, all devices having 50 × 50 μm² μcell size. For each SiPM the gain G, dark count rate DCR and beta sensitivity were measured as a function of Vbias and temperature. The obtained results showed that the small field of view and newly developed structure of the KETEK devices allow a large decrease of the dark count rate DCR. However, this small field of view also leads to a reduced light collection due to the thickness of the epoxy protection resin on top of the SiPM and the acceptance angle of the fiber. Since the beta sensitivity represents a tradeoff between photon detection efficiency PDE and dark count rate DCR, KETEK SiPMs exhibit similar performances in comparison with the Hamamatsu device. Preliminary results demonstrate that the beta sensitivity of KETEK devices can be significantly improved by using focusing lens between the scintillating fiber and the SiPM or by reducing the thickness of its epoxy protection resin.

Nagai, Andrii↗

Boron-coated straw neutron detector for well-logging-Final Technical Report

The Oil & Gas exploration industry makes extensive use of radiation detectors for well logging – a geologic formation map that reveals crucial information for the viability of oil/gas extraction in surveyed wells. Helium-3 gas filled neutron detectors have been the gold standard for neutron porosity logs, one of two components in nuclear logging (gamma ray logs being the other component). The finite supply of 3He gas has dwindled in recent years due to an increased use in Homeland Security applications; therefore the need for alternative technologies that would ensure oil & gas exploration for coming years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(Multi-)strange hadron and light (anti-)nuclei production with ALICE at the LHC

Thanks to its excellent tracking performance and particle identification capabilities, the ALICE detector allows for the identification of light (anti-)(hyper)nuclei and for the measurement of (multi-)strange particles over a wide range of transverse momentum. Deuterons, {sup 3}He and {sup 4}He and their corresponding anti-nuclei are identified via their specific energy loss in the Time Projection Chamber and the velocity measurement provided by the Time-Of-Flight detector. Strange and multi-strange baryons and mesons as well as (anti-)hypertritons are reconstructed via their topological decays. Detailed measurements of (multi-)strange hadron production in pp, p–Pb and Pb–Pb collision and of light (anti-)nuclei and (anti-)hypertritons in Pb–Pb collisions with ALICE at the LHC are presented. The experimental results will be compared with the predictions of both statistical hadronization and coalescence models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Large Cryogenic Semiconductor Detectors

This project aims at developing large cryogenic semiconductor detectors for applications in particle physics and more broadly. We have developed a 150 mm diameter, 43 mm thick, Si-based detector that measures ionization released in an interaction of a particle inside the silicon crystal of high purity, operated at 30 mK temperature. We demonstrated that such a detector can be used to measure recoil energies on the keV scale, and that its stable operation can be maintained indefinitely. Detectors of this type could therefore be used in the fields of direct dark matter searches, coherent neutrino scattering measurements, X-ray observations, as well as in broader applications such as homeland security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Analysis of the Extreme Physical Shock Environment Experienced by Crane-Mounted Radiation Detection Systems.

Potentially, radiation detectors at ports of entry could be mounted on container gantry crane spreaders to monitor cargo containers entering and leaving the country. These detectors would have to withstand the extreme physical environment experienced by these spreaders during normal operations. Physical shock data from the gable ends of a spreader were recorded during the loading and unloading of a cargo ship with two Lansmont SAVER 9X30 units (with padding) and two PCB Piezotronics model 340A50 accelerometers (hard mounted). Physical shocks in the form of rapid acceleration were observed in all accelerometer units with values ranging from 0.20 g’s to 199.99 g’s. The majority of the shocks for all the Lansmont and PCB accelerometers were below 50 g’s. The Lansmont recorded mean shocks of 21.83 ± 13.62 g’s and 24.78 ± 11.49 g’s while the PCB accelerometers experienced mean shocks of 34.39 ± 25.51 g’s and 41.77 ± 22.68 g’s for the landside and waterside units, respectively. Encased detector units with external padding should be designed to withstand at least 200 g’s of acceleration without padding and typical shocks of 30 g’s with padding for mounting on a spreader.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmogenic activation of silicon

In the production of 3 H, 7 Be, and 22 Na by interactions of cosmic-ray particles with silicon can produce radioactive backgrounds in detectors used to search for rare events. Through controlled irradiation of silicon CCDs and wafers with a neutron beam that mimics the cosmic-ray neutron spectrum, followed by direct counting, we determined that the production rate from cosmic-ray neutrons at sea level is (112 ± 24) atoms/( kg day ) for 3 H, (8.1 ± 1.9) atoms/( kg day ) for 7 Be, and (43.0 ± 7.2) atoms/( kg day ) for 22 Na . Complementing these results with the current best estimates of activation cross sections for cosmic-ray particles other than neutrons, we obtain a total sea-level cosmic-ray production rate of (124 ± 25) atoms/(kg day) for 3 H, (9.4 ± 2.0) atoms/( kg day ) for 7 Be, and (49.6 ± 7.4) atoms/( kg day ) for 22 Na. These measurements will help constrain background estimates and determine the maximum time that silicon-based detectors can remain unshielded during detector fabrication before cosmogenic backgrounds impact the sensitivity of next-generation rare-event searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low energy neutrino detection with a compact water-based liquid scintillator detector

In this study, the conceptual design and physics simulations of a near-field Water-based Liquid Scintillator (WbLS) detector placed 100 m from the Akkuyu Nuclear Power Plant (ANPP), currently under construction and aiming at being Turkey’s first nuclear power plant, is presented. The ANPP is an excellent opportunity for neutrino studies and the development of an R &D program for neutrino detectors in Turkey. The Reactor Neutrino Experiments of Turkey (RNET) program includes a compact detector with a 2.5-ton volume of WbLS and a ~ 30% photo-coverage, and the program is planned to be expanded with a medium-size 30-ton detector that will be an international testbed for WbLS and new detector technologies through low energy neutrino studies. In the following, the focus will be on the smaller ~2.5 ton detector, instrumented with 8-in. high quantum efficiency PMTs and two layers of cosmic veto paddles, covering all sides of the detector, to track and veto cosmic particles. Inverse Beta Decay (IBD) events from electron anti-neutrinos generated in the reactor core are simulated using the RAT-PAC simulation package and several liquids with different percentages of Liquid Scintillator (LS) and Gadolinium (Gd) are investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-shape analysis in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 room-temperature radiation detectors

The effect of trapping of charge carriers on the shape of the charge pulses from room temperature nuclear detectors, based on a recently discovered quaternary semiconductor Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS), has been studied. Here, we present a charge-trapping model that explains the pulse shapes for its entire duration from radiation detectors containing multiple defect types. A piecewise continuous model, based on the movement of a large number of charge carriers rather than a single charge, has been proposed to explain the pulse shapes from planar room temperature nuclear detectors. An experimental method based on the model has been described to extract charge-trapping information. This model can be applied to similar semiconductor detectors with electrically active trap centers, in general, to extract information like pre-trapping drift times. Charge pulses from a CZTS planar detector, exposed to 5486 keV alpha particles emitted by a 241Am source, were acquired using a digitizer, and the pulse shapes were explained based on the proposed model. The pre-trapping drift times for electrons as well as holes in CZTS were calculated and studied as a function of operating bias voltage, and a contrast between their bias dependent behaviors was noticed, indicating the behavioral difference of electron and hole traps.

42 ENGINEERING↗

Single-view 3D reconstruction of correlated gamma-neutron sources

We describe a new method of 3D image reconstruction of neutron sources that emit correlated gammas (e.g. Cf- 252, Am-Be). This category includes a vast majority of neutron sources important in nuclear threat search, safeguards and non-proliferation. Rather than requiring multiple views of the source this technique relies on the source’s intrinsic property of coincidence gamma and neutron emission. As a result only a single-view measurement of the source is required to perform the 3D reconstruction. In principle, any scatter camera sensitive to gammas and neutrons with adequate timing and interaction location resolution can perform this reconstruction. Using a neutron double scatter technique, we can calculate a conical surface of possible source locations. By including the time to a correlated gamma we further constrain the source location in three-dimensions by solving for the source-to-detector distance along the surface of said cone. As a proof of concept we applied these reconstruction techniques on measurements taken with the the Mobile Imager of Neutrons for Emergency Responders (MINER). Two Cf-252 sources measured at 50 and 60 cm from the center of the detector were resolved in their varying depth with average radial distance relative resolution of 26%. To demonstrate the technique’s potential with an optimized system we simulated the measurement in MCNPX-PoliMi assuming timing resolution of 200 ps (from 2 ns in the current system) and source interaction location resolution of 5 mm (from 3 cm). Furthermore, these simulated improvements in scatter camera performance resulted in radial distance relative resolution decreasing to an average of 11%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactor neutrino applications and coherent elastic neutrino nucleus scattering

Potential applications of neutrino detection to nuclear security have been discussed since the 1970s. Recent years have seen great progress in detector technologies based on inverse beta decay, with the demonstration of ton-scale surface-level detectors capable of high quality neutrino spectrum measurements. At the same time coherent elastic neutrino nucleus scattering has been experimentally confirmed in 2017 with neutrinos from stopped pion decay and there is a number of experiments aimed at seeing this reaction with reactor neutrinos. Here, the large cross section and threshold-less nature of this reaction make it plausible to consider it for applications to nuclear security and here, we present a first direct comparison of the two reaction modes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of temporally- and spatially-resolved neutron production in a sheared-flow stabilized Z-pinch

A novel approach using multiple scintillator detectors is applied to measure temporally- and spatially-resolved neutron production in the Fusion Z-pinch Experiment (FuZE) device, a Sheared-Flow Stabilized (SFS) Z-pinch. Diagnosing neutron production from FuZE is important for determining if fusion is thermonuclear and whether the FuZE device can be scaled toward reactor conditions. Absolute yields of up to 2 × 10 5 neutrons per discharge are measured with calibrated plastic scintillator detectors operating in pulse-counting mode. Neutron emission durations of up to ~8 μs are inferred by recording the time difference between the first and last pulses for each discharge. Multiple scintillator detectors located at different positions with respect to the fusing plasma are used to demonstrate that the axial extent of the neutron producing region is comparable to the device volume. Scintillator detectors are well-suited as neutron diagnostics for FuZE and other plasma devices with similar yields and emission durations. Increasing the neutron yield, duration, and volume of the neutron emitting region within the plasma column are significant experimental objectives for FuZE.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗