Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DER systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Theoretical study of the CO 2 –O 2 van der Waals complex: potential energy surface and applications

A four-dimensional-potential energy surface (4D-PES) of the atmospherically relevant carbon dioxide–oxygen molecule (CO 2 –O 2 ) van der Waals complex is mapped using the ab initio explicitly correlated coupled cluster method with single, double, and perturbative triple excitations (UCCSD(T)-F12b), and extrapolation to the complete basis set (CBS) limit using the cc-pVTZ-F12/cc-pVQZ-F12 bases and the l –3 formula. An analytic representation of the 4D-PES was fitted using the method of interpolating moving least squares (IMLS). These calculations predict that the most stable configuration of CO 2 –O 2 complex corresponds to a planar slipped-parallel structure with a binding energy of V ~ –243 cm –1 . Another isomer is found on the PES, corresponding to a non-planar cross-shaped structure, with V ~ –218 cm –1 . The transition structure connecting the two minima is found at V ~ –211 cm –1 . We also performed comparisons with some CO 2 –X van der Waals complexes. Moreover, we provide a SAPT analysis of this molecular system. Then, we discuss the complexation induced shifts of CO 2 and O 2 . Afterwards, this new 4D-PES is employed to compute the second virial coefficient including temperature dependence. A comparison between quantities obtained in our calculations and those from experiments found close agreement attesting to the high quality of the PES and to the importance of considering a full description of the anisotropic potential for the derivation of thermophysical properties of CO 2 –O 2 mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collective states and charge density waves in the group IV transition metal trichalcogenides

It has been nearly a century since the original mechanism for charge density wave (CDW) formation was suggested by Peierls. Since then, the term has come to describe several related concepts in condensed matter physics, having their origin in either the electron–phonon or electron–electron interaction. The vast majority of CDW literature deals with systems that are metallic, where discussions of mechanisms related to the Fermi surface are valid. Recently, it has been suggested that semiconducting systems such as TiS 3 and TiSe 2 exhibit behavior related to CDWs. In such cases, the origin of the behavior is more subtle and intimately tied to electron–electron interactions. We introduce the different classifications of CDW systems that have been proposed and discuss work on the group IV transition metal trichalcogenides (TMTs) (ZrTe 3 , HfTe 3 , TiTe 3 , and TiS 3 ), which are an exciting and emergent material system whose members exhibit quasi-one-dimensional properties. TMTs are van der Waals materials and can be readily studied in the few-layer limit, opening new avenues to manipulating collective states. We emphasize the semiconducting compound TiS 3 and suggest how it can be classified based on available data. Although we can conjecture on the origin of the CDW in TiS 3 , further measurements are required to properly characterize it.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

van der Waals corrected density functionals for cylindrical surfaces: Ammonia and nitrogen dioxide adsorbed on a single-walled carbon nanotube

In this work, we extend the damped Zaremba-Kohn model (dZK) for long-range dispersion interaction between a molecule and a planar surface to molecules adsorbed on a curved cylindrical surface, and employ this extended model as an additive correction to the semilocal density functionals PBE (Perdew-Burke-Ernzerhof) and SCAN (strongly constrained and appropriately normed). The resulting PBE+vdW (van der Waals)-dZK and SCAN+vdW-dZK are applied to two systems, NH3 and NO2 molecules adsorbed on a single-wall carbon nanotube (CNT), for calculations of binding energies and equilibrium distances. For comparison, the results from vdW nonlocal functionals, such as SCAN+rVV10 and PBE+rVV10, are also presented. The binding energies from PBE+rVV10 (Vydrov and Van Voorhis), SCAN+rVV10, PBE+vdW-dZK, and SCAN+vdW-dZK are about 70–115 meV for the system of CNT + NH 3 and 300–500 meV for the system of CNT + NO 2 . The results from PBE+vdW-dZK and SCAN+vdW-dZK are closer to each other than those from PBE+rVV10 and SCAN+rVV10 are. The relatively closer results from PBE+vdW-dZK and SCAN+vdW-dZK indicate the consistency of our developed vdW–dZK model for cylindrical surfaces. All methods, including PBE, SCAN, PBE+rVV10, SCAN+rVV10, PBE+vdW-dZK, and SCAN+vdW-dZK, give approximately the same binding energy differences between two adsorption configurations (types I and II) for the two systems. This implies that the two adsorption sites have approximately the same adsorption stability. The exponent of the vdW interaction power law from our vdW-dZK model for the two systems is about 0 at short distance, largely due to the damping factor, and tends slowly to –4 to –4.5 at distances D about 20–50 Å. At even larger distances, the vdW power-law exponent approaches –5. This feature is very similar to the one calculated with random-phase approximation and renormalization group approaches, supporting the applicability of our methods. Our developed vdW-dZK method provides a highly efficient and reliable method for large systems with cylindrical surfaces, such as vdW interactions with nanotubes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decay of Electrostatic Force of Dust Particles on Photovoltaic Modules

Photovoltaic (PV) energy yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. We have reported on direct measurements-using atomic force microscopy (AFM)-of strong electric-field-induced attraction and adhesion force (Fes) of dust particles onto solar panel that are 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, corroborated by observing the increase in system voltage-induced soiling rate. Here, we report another characteristic of Fes on soiling-long lasting or slow decay after turning off the high voltage applied to solar panels. The Fes decay time varies in a wide time range of 1 to 10 hours, depending on two factors: 1) either/both the cell or/and particle were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off-either connected through the power supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting Fes for hours can significantly affect the solar panel soiling after sunset, especially combined with water condensation.

14 SOLAR ENERGY↗

Stochastic Strategic Participation of Active Distribution Networks With High-Penetration DERs in Wholesale Electricity Markets

With the increasing penetration of distributed energy resources (DERs), traditional distribution networks as load-serving entities in wholesale electricity markets, now evolve towards active distribution networks (ADNs) which can proactively participate in wholesale markets by optimally controlling the DERs in their networks. A stochastic bilevel optimization model is proposed in this paper for the strategic participation of ADNs and DERs to provide energy and grid services in wholesale electricity markets. The bilevel optimization model can capture the interactions between the ADN and the wholesale energy and ancillary service markets, considering the uncertainties of DERs in the ADN. In the upper-level model, the ADN makes optimal decisions on energy and reserve bidding considering the availability, uncertainties, and flexibility of DERs. The joint energy and reserve market-clearing of the independent system operator (ISO) is modeled as the lower-level problem. Using strong duality theory and Karush-Kuhn Tucker (KKT) conditions, the proposed bilevel optimization problem is reformulated as mathematical programming with equilibrium constraints (MPEC) problem and further converted into a computationally-solvable mixed-integer second-order-cone programming (MISOCP) model. The simulation results demonstrate the effectiveness of the model and the interactions between an ADN and wholesale electricity markets.

active distribution network↗

Demonstrating the Transient System Impact of Cyber-Physical Events Through Scalable Transmission and Distribution (T&D) Co-Simulation

Modern power systems become more vulnerable to cyber threats due to their growing interconnectivity, interdependence, and complexity. Widespread deployment of distributed energy resources (DERs) further expands the threat landscape to the grid edge, where fewer cybersecurity protections exist. In this article, a systematic cyber-physical events demonstration, enabled by an integrated transmission, distribution, and communication co-simulation framework, is performed. It analyzes cyber risks to power grid under DER-enabled automatic generation control from different angles. Unlike existing works, the simulation captures millisecond-to-minutes frequency and voltage transient dynamics at a cross-region system scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recommendations for Distributed Energy Resource Patching

While computer systems, software applications, and operational technology (OT)/Industrial Control System (ICS) devices are regularly updated through automated and manual processes, there are several unique challenges associated with distributed energy resource (DER) patching. Millions of DER devices from dozens of vendors have been deployed in home, corporate, and utility network environments that may or may not be internet-connected. These devices make up a growing portion of the electric power critical infrastructure system and are expected to operate for decades. During that operational period, it is anticipated that critical and noncritical firmware patches will be regularly created to improve DER functional capabilities or repair security deficiencies in the equipment. The SunSpec/Sandia DER Cybersecurity Workgroup created a Patching Subgroup to investigate appropriate recommendations for the DER patching, holding fortnightly meetings for more than nine months. The group focused on DER equipment, but the observations and recommendations contained in this report also apply to DERMS tools and other OT equipment used in the end-to-end DER communication environment. The group found there were many standards and guides that discuss firmware lifecycles, patch and asset management, and code-signing implementations, but did not singularly cover the needs of the DER industry. This report collates best practices from these standards organizations and establishes a set of best practices that may be used as a basis for future national or international patching guides or standards.

97 MATHEMATICS AND COMPUTING↗

SPECs Early-Stage Decision Model: User Manual

The SPECs Early-Stage Decision (ESD) model is central to the SPECs procurement solutions toolkit. The ESD model is an Excel-based spreadsheet model, which provides information about the economic and strategic value of a proposed battery-storage project or solar-plus-storage (solar-plus) project. The model can be used to explore combinations of storage-related project value streams in order to define a potential project, while educating co-op decision-makers about project benefits and costs. A sensitivity analysis function speeds the development of "what-if" scenarios. A gap analysis function solves for top-priority metrics and supports the inclusion of hard-to-monetize strategic values, such as the value of storage to defer costly system upgrades in light of increasing distributed solar and other distributed energy resources (DERs). Model outputs include the utility data, assumptions, and use-case scenarios that are recommended content for the requests for proposals (RFPs). The model may also provide an initial "sanity check" for RFP responses, supporting further discussions among utility staff, vendors and stakeholders. The ESD is not a "finance-grade" modeling tool, and users are cautioned to be mindful of its limitations, but the model has been reviewed by users, who recommend it as a way to drive faster and better project design and planning, as well as to facilitate better communications with vendors, grid partners, and stakeholders.

14 SOLAR ENERGY↗

State-to-state rate coefficients for HCS+ in rotationally inelastic collisions with H2 at low temperatures

ABSTRACT HCS+ ions have been detected in several regions of the interstellar medium (ISM), but an accurate determination of the chemical-physical conditions in the molecular clouds where this molecule is observed requires detailed knowledge of the collisional rate coefficients with the most common colliders in those environments. In this work, we study the dynamics of rotationally inelastic collisions of HCS+ + H2 at low temperature, and report, for the first time, a set of rate coefficients for this system. We used a recently developed potential energy surface for the HCS+–H2 van der Waals complex and computed state-to-state rotational rate coefficients for the lower rotational states of HCS+ in collision with both para- and ortho-H2, analysing the influence of the computed rate coefficients on the determination of critical densities. Additionally, the computed rate coefficients are compared with those obtained by scaling the ones from HCS+ in collision with He (an approximation that is sometimes used when data is lacking), and large differences are found. Furthermore, the approximation of using the rates for the HCO+ + H2 collision as a rough approximation for those of the HCS+ + H2 system is also evaluated. Finally, the complete set of de-excitation rate coefficients for the lowest 30 rotational states of HCS+ by collision with H2 is reported from 5 to 100 K.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking

As distributed energy resources (DERs) play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled HELICS-based co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. These results are compared to the same distribution system run without co-simulation using a fixed feed-in voltage. Results show that even without advanced voltage controls, the feed-in voltage response when coupled to the transmission system results a lower level of voltage excursions, suggesting the importance of using this type of realistic, tightly coupled, transmission and distribution co-simulation when assessing DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-element flow-driven spectral chaos (ME-FSC) method for uncertainty quantification of dynamical systems

The flow-driven spectral chaos (FSC) is a recently developed method for tracking and quantifying uncertainties in the long-time response of stochastic dynamical systems using the spectral approach. The method uses a novel concept called enriched stochastic flow maps as a means to construct an evolving finite-dimensional random function space that is both accurate and computationally efficient in time. In this paper, we present a multi-element version of the FSC method (the ME-FSC method for short) to tackle (mainly) those dynamical systems that are inherently discontinuous over the probability space. In ME-FSC, the random domain is partitioned into several elements, and then the problem is solved separately on each random element using the FSC method. Subsequently, results are aggregated to compute the probability moments of interest using the law of total probability. To demonstrate the effectiveness of the ME-FSC method in dealing with discontinuities and long-time integration of stochastic dynamical systems, four representative numerical examples are presented in this paper, including the Van-der-Pol oscillator problem and the Kraichnan-Orszag three-mode problem. Results show that the ME-FSC method is capable of solving problems that have strong nonlinear dependencies over the probability space, both reliably and at low computational cost.

97 MATHEMATICS AND COMPUTING↗

Exciton-driven antiferromagnetic metal in a correlated van der Waals insulator

Abstract Collective excitations of bound electron-hole pairs—known as excitons—are ubiquitous in condensed matter, emerging in systems as diverse as band semiconductors, molecular crystals, and proteins. Recently, their existence in strongly correlated electron materials has attracted increasing interest due to the excitons’ unique coupling to spin and orbital degrees of freedom. The non-equilibrium driving of such dressed quasiparticles offers a promising platform for realizing unconventional many-body phenomena and phases beyond thermodynamic equilibrium. Here, we achieve this in the van der Waals correlated insulator NiPS 3 by photoexciting its newly discovered spin–orbit-entangled excitons that arise from Zhang-Rice states. By monitoring the time evolution of the terahertz conductivity, we observe the coexistence of itinerant carriers produced by exciton dissociation and a long-wavelength antiferromagnetic magnon that coherently precesses in time. These results demonstrate the emergence of a transient metallic state that preserves long-range antiferromagnetism, a phase that cannot be reached by simply tuning the temperature. More broadly, our findings open an avenue toward the exciton-mediated optical manipulation of magnetism.

36 MATERIALS SCIENCE↗

Modeling Contact Angle vs. Temperature for the Quartz-Water-Decane System

Innovative approaches are needed to improve the efficiency of oil recovery technologies to meet the growing demands of fossil-fuel based energy consumption. Enhanced oil recovery (EOR) methods such as low-salinity waterflooding and chemically tuned waterflooding aim to optimize the reservoir’s wetting properties, detaching oil globules from rock surfaces and allowing easier oil flow through pore throats. This wetting behavior is commonly quantified by contact angle measurements of the rock-oil-brine interface, which have been thoroughly investigated and theorized for many systems at ambient temperatures and pressures. However, few studies exist for extending contact angle theories away from ambient conditions. In this paper, we model the contact angles of a quartz-water-decane system at elevated temperatures using the surface tension component (STC) approach. Temperature-dependent van der Waals [Lifshitz-van der Waals (LW)] interactions and hydrogen-bonding (acid-base) interactions were calculated and are incorporated into the model for the quartz-water-decane interface. Additionally, the Hough and White procedure was used to create temperature-dependent dielectric functions of quartz, water, and normal decane for calculations of Hamaker coefficients. Hamaker coefficients calculated this way are highly linear with temperature and agree well with Israelachvili’s approximation. The acid-base interactions likely contribute the most to system wettability changes. Resulting contact angles of the quartz-water-decane system shift from water-wet (16°) to slightly water-wet (57.4°) as temperature increases. The model was also successfully verified for the quartz-air-water system. Our results can be used in future studies to determine optimal injected water compositions for specific rock-oil-brine and other systems with consideration of reservoir temperature.

02 PETROLEUM↗

Resilience of the Electric Grid Through Trustable IoT-Coordinated Assets

The electricity grid has evolved from a physical system to a cyberphysical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) including renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. We propose a framework in this paper for achieving grid resilience through suitably coordinated assets including a network of Internet of Things devices. A local electricity market is proposed to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. With this SA, we show that a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. Multiple demonstrations are carried out using a high-fidelity cosimulation platform, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

distributed energy resources↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗