Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DECOMPRESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Oxygen transport and cardiovascular function at extreme altitude: lessons from Operation Everest II

Operation Everest II was designed to examine the physiological responses to gradual decompression simulating an ascent of Mt Everest (8,848 m) to an inspired PO2 of 43 mmHg. The principal studies conducted were cardiovascular, respiratory, muscular-skeletal and metabolic responses to exercise. Eight healthy males aged 21-31 years began the "ascent" and six successfully reached the "summit", where their resting arterial blood gases were PO2 = 30 mmHg and PCO2 = 11 mmHg, pH = 7.56. Their maximal oxygen uptake decreased from 3.98 +/- 0.2 L/min at sea level to 1.17 +/- 0.08 L/min at PIO2 43 mmHg. The principal factors responsible for oxygen transport from the atmosphere to tissues were (1) Alveolar ventilation--a four fold increase. (2) Diffusion from the alveolus to end capillary blood--unchanged. (3) Cardiac function (assessed by hemodynamics, echocardiography and electrocardiography)--normal--although maximum cardiac output and heart rate were reduced. (4) Oxygen extraction--maximal with PvO2 14.8 +/- 1 mmHg. With increasing altitude maximal blood and muscle lactate progressively declined although at any submaximal intensity blood and muscle lactate was higher at higher altitudes.

Non-NASA Center↗

Compartment syndrome of the thigh complicating surgical treatment of ipsilateral femur and ankle fractures

A 26-year-old man presented with ipsilateral femur and ankle fractures. The patient was treated with interlocking nail of his femur fracture, followed by open reduction and internal fixation of his ankle fracture under tourniquet control. Postoperatively, the patient developed compartment syndrome of his thigh with elevated pressures, requiring decompressive fasciotomies. This case illustrates the possible complication of treating a femur fracture with intramedullary nailing and then immediately applying a tourniquet to treat an ipsilateral extremity fracture. Because of the complication with this patient, we feel the procedure should be staged, or a tourniquet should be avoided if possible.

Case Reports↗

Public Outreach and Archiving of Data from the High Resolution Stereo Camera Onboard Mars Express: 2004 The First Year

During the first year of operation, corresponding to the calendar year 2004, the HRSC imaging experiment onboard ESA's Mars Express mission recorded 23 Gigabyte of 8-bit compressed raw data. After processing, the amount of data increased to more than 344 Gigabyte of decompressed and radiometrically calibrated scientifically useable image products. Every six months these HRSC Level 2 data are fed into ESA's Planetary Science Archive (PSA) that sends all data also to the Planetary Data System (PDS) to ensure easy availability to the interested user. On their respective web portals, the European Space Agency published in cooperation with the Principal Investigator-Group at Freie Universitat Berlin and the German Space Agency (DLR) almost 40 sets of high-level image scenes and movies for PR needs that have been electronically visited many hundred thousand times.

Koehler, U.↗

A Chemical Model of Micrometeorite Impact into Olivine

Laboratory simulations of space weathering using laser irradiation have been successful in reproducing space weathering characteristics such as the reduction of olivine to form nanophase iron particles. However, the chemistry of the reduction of Fe2+ in olivine to Fe metal has not been fully explored. We present a thermodynamic model of olivine undergoing post-impact cooling and decompression.

Sheffer, A. A.↗

Field Evaluation in Four NEEMO Divers of a Prototype In-suit Doppler Ultrasound Bubble Detector

It is desirable to know if astronauts produce venous gas emboli (VGE) as a result of their exposure to 4.3 psia during space walks. The current prototype in-suit Doppler (ISD) ultrasound bubble detector provides an objective assessment of decompression stress by monitoring for VGE. The NOAA Aquarius habitat and NASA Extreme Environment Mission Operations (NEEMO) series of dives provided an opportunity to assess the ability of the prototype ISDs to record venous blood flow and possibly detect VGE in the pulmonary artery. From July 16 to 29,2003, four aquanauts (two males and two females) donned the ISD for a 4 hr automated recording session, following excursion dives (up to 6hrs and 29 MSW below storage depth) from air saturation at 17 MSW. Doppler recordings for 32 excursion dives were collected. The recordings consisted of approximately 150 digital wave files. Each wave file contained 24 sec of recording for each min. A 1 - 4 Doppler Quality Score (DQS) was assigned to each wave file in 17 of the 32 records evaluated to date. A DQS of 1 indicates a poor flow signal and a score of 4 indicates an optimum signal. Only 23% of all wave files had DQSs considered adequate to detect low grade VGE (Spencer I-II). The distribution of DQS in 2,356 wave files is as follows: DQS 1-56%, DQS 2-21%, DQS 3-18% and DQS 4-5%. Six of the 17 records had false positive VGE (Spencer I-IV) detected in one or more wave files per dive record. The false positive VGE recordings are attributable to air entrainment associated with drinking (verified by control tests), and this observation is important as astronauts drink water during space walks. The current ISD design provides quality recordings only over a narrow range of chest anatomy.

Acock, K. E.↗

Exploration Spacecraft and Space Suit Internal Atmosphere Pressure and Composition

The design of habitat atmospheres for future space missions is heavily driven by physiological and safety requirements. Lower EVA prebreathe time and reduced risk of decompression sickness must be balanced against the increased risk of fire and higher cost and mass of materials associated with higher oxygen concentrations. Any proposed increase in space suit pressure must consider impacts on space suit mass and mobility. Future spacecraft designs will likely incorporate more composite and polymeric materials both to reduce structural mass and to optimize crew radiation protection. Narrowed atmosphere design spaces have been identified that can be used as starting points for more detailed design studies and risk assessments.

Lange, Kevin↗

Exploration Health Risks: Probabilistic Risk Assessment

Maintenance of human health on long-duration exploration missions is a primary challenge to mission designers. Indeed, human health risks are currently the largest risk contributors to the risks of evacuation or loss of the crew on long-duration International Space Station missions. We describe a quantitative assessment of the relative probabilities of occurrence of the individual risks to human safety and efficiency during space flight to augment qualitative assessments used in this field to date. Quantitative probabilistic risk assessments will allow program managers to focus resources on those human health risks most likely to occur with undesirable consequences. Truly quantitative assessments are common, even expected, in the engineering and actuarial spheres, but that capability is just emerging in some arenas of life sciences research, such as identifying and minimize the hazards to astronauts during future space exploration missions. Our expectation is that these results can be used to inform NASA mission design trade studies in the near future with the objective of preventing the higher among the human health risks. We identify and discuss statistical techniques to provide this risk quantification based on relevant sets of astronaut biomedical data from short and long duration space flights as well as relevant analog populations. We outline critical assumptions made in the calculations and discuss the rationale for these. Our efforts to date have focussed on quantifying the probabilities of medical risks that are qualitatively perceived as relatively high risks of radiation sickness, cardiac dysrhythmias, medically significant renal stone formation due to increased calcium mobilization, decompression sickness as a result of EVA (extravehicular activity), and bone fracture due to loss of bone mineral density. We present these quantitative probabilities in order-of-magnitude comparison format so that relative risk can be gauged. We address the effects of conservative and nonconservative assumptions on the probability results. We discuss the methods necessary to assess mission risks once exploration mission scenarios are characterized. Preliminary efforts have produced results that are commensurate with earlier qualitative estimates of risk probabilities in this and other operational contexts, indicating that our approach may be usefully applied in support of the development of human health and performance standards for long-duration space exploration missions. This approach will also enable mission-specific probabilistic risk assessments for space exploration missions.

Rhatigan, Jennifer↗

Gender Consideration in Experiment Design for Airbrake in Prebreathe

If gender is a confounder of the decompression sickness (DCS) or venous gas emboli (VGE) outcomes of a proposed air break in oxygen prebreathe (PB) project, then decisions about the final experiment design must be made. We evaluated if the incidence of DCS and VGE from tests in altitude chambers over 20 years were different between men and women after resting and exercise prebreathe protocols. Nitrogen washout during PB is our primary risk mitigation strategy to prevent subsequent DCS and VGE in subjects. Bubbles in the pulmonary artery (venous blood) were detected from the precordial position using Doppler ultrasound bubble detectors. The subjects were monitored for VGE for four min at about 15 min intervals for the duration of the altitude exposure, with maximum bubble grade assigned a Spencer Grade of IV. There was no difference in DCS incidence between men and women in either PB protocol. The incidence of VGE and Grade IV VGE is statistically lower in women compared to men after resting PB. Even when 10 tests were compared with Mantel-Haenszel 2 where both men (n = 168) and women (n = 92) appeared, the p-value for VGE incidence was still significant at 0.03. The incidence of VGE and Grade IV VGE is not statistically lower in women compared to men after exercise PB. Even when six tests were compared with Mantel-Haenszel x2 where both men (n = 165) and women (n = 49) appeared, the p-value for VGE incidence was still not significant at 0.90. Our goal is to understand the risk of brief air breaks during PB without other confounding variables invalidating our conclusions. The cost to additionally account for the confounding role of gender on VGE outcome after resting PB is judged excessive. Our decision is to only evaluate air breaks in the exercise PB protocol. So there is no restriction to recruiting women as test subjects.

Conkin, Johnny↗

Eva Physiology, Systems, and Performance (EPSP) Project Overview

Extravehicular activity (EVA) is any activity performed by astronauts outside their space vehicle or habitat. EVA may be performed on orbit, such as outside the Space Shuttle or the International Space Station, or on a planetary surface such as Mars or on the moon. Astronauts wear a pressurized suit that provides environmental protection, mobility, life support, and communications while they work in the harsh conditions of a microgravity environment. Exploration missions to the moon and Mars may last many days and will include many types of EVAs; exploration, science, construction and maintenance. The effectiveness and success of these EVA-filled missions is dependent on the ability to perform tasks efficiently. The EVA Physiology, Systems and Performance (EPSP) project will conduct a number of studies to understand human performance during EVA, from a molecular level to full-scale equipment and suit design aspects, with the aim of developing safe and efficient systems for Exploration missions and the Constellation Program. The EPSP project will 1) develop Exploration Mission EVA suit requirements for metabolic and thermal loading, optional center of gravity location, biomedical sensors, hydration, nutrition, and human biomedical interactions; 2) develop validated EVA prebreathe protocols that meet medical, vehicle, and habitat constraints while minimizing crew time and thus increasing EVA work efficiency; and 3) define exploration decompression sickness (DCS) risks, policy, and mission success statistics and develop a DCS risk definition report.

Gernhardt, Michael L.↗

Gender Consideration in Experiment Design for Air Break in Prebreathe

If gender is a confounder of the decompression sickness (DCS) or venous gas emboli (VGE) outcomes of a proposed air break in oxygen prebreathe (PB) project, then decisions about the final experiment design must be made. We evaluated if the incidence of DCS and VGE from tests in altitude chambers over 20 years were different between men and women after resting and exercise PB protocols. Nitrogen washout during PB is our primary risk mitigation strategy to prevent subsequent DCS and VGE in subjects. Bubbles in the pulmonary artery (venous blood) were detected from the precordial position using Doppler ultrasound bubble detectors. The subjects were monitored for VGE for four min at about 15 min intervals for the duration of the altitude exposure, with maximum bubble grade assigned a Spencer Grade of IV.

Conkin, Johnny↗

Risk Assessment of Physiological Effects of Atmospheric Composition and Pressure in Constellation Vehicles

To limit the risk of fire and reduce denitrogenation time to prevent decompression sickness to support frequent extravehicular activities on the Moon, a hypobaric (PB = 414 mmHg) and mildly hypoxic (ppO2 = 132 mmHg, 32% O2 - 68% N2) living environment is considered for the Crew Exploration Vehicle (CEV) and Lunar Surface Access Module (LSAM). With acute change in ppO2 from 145-178 mmHg at standard vehicular operating pressure to less than 125 mmHg at desired lunar surface vehicular operating pressures, there is the possibility that some crewmembers may develop symptoms of Acute Mountain Sickness (AMS). The signs and symptoms of AMS (headache plus nausea, dizziness, fatigue, or sleeplessness), could impact crew health and performance on lunar surface missions. An exhaustive literature review on the topic of the physiological effects of reduced ppO2 and absolute pressure as may contribute to the development of altitude symptoms or AMS was performed. The results of the nine most rigorous studies were collated, analyzed and contents on AMS and hypoxia symptoms summarized. There is evidence for an absolute pressure effect per se on AMS, so the higher the altitude for a given hypoxic alveolar O2 partial pressure (PAO2), the greater the AMS response. About 25% of adults are likely to experience mild AMS near 2,000 m altitude following a rapid ascent from sea level while breathing air (6,500 feet, acute PAO2 = 75 mmHg). The operational experience with the Shuttle staged denitrogenation protocol at 528 mmHg (3,048 m) while breathing 26.5% O2 (acute PAO2 = 85 mmHg) in astronauts adapting to microgravity suggests a similar likely experience in the proposed CEV environment. We believe the risk of mild AMS is greater given a PAO2 of 77 mmHg at 4,876 m altitude while breathing 32% O2 than at 1,828 m altitude while breathing 21% O2. Only susceptible astronauts would develop mild and transient AMS with prolonged exposure to 414 mmHg (4,876 m) while breathing 32% O2 (acute PAO2 = 77 mmHg). So the following may be employed for operational risk reduction: 1) develop procedures to increase PB as needed in the CEV, and use a gradual or staged reduction in cabin pressure during lunar outbound; 2) train crews for symptoms of hypoxia, to allow early recognition and consider pre-adaptation of crews to a hypoxic environment prior to launch, 3) consider prophylactic acetazolamide for acute pressure changes and be prepared to treat any AMS associated symptoms early with both carbonic anhydrase inhibitors and supplemental oxygen.

Scheuring, Richard A.↗

Artificial Gravity as a Multi-System Countermeasure: Effects on Cognitive Function

The Space Flight Cognitive Assessment Tool for Windows (WinSCAT) is a medical requirement on the International Space Station, and its purpose is to evaluate cognitive functioning after physical insult (e.g., head trauma, decompression sickness, exposure to toxic gases, medication side effects). The current objective is to assess cognitive functioning in a long duration space mission analog environment where Artificial Gravity is being applied as a countermeasure in a Bed Rest study. Methods: Fifteen male subjects (8 treatment and 7 control) who participated in 21 days of -6 degree head-down bed rest were assessed. Three practice and three baseline WinSCAT test sessions were administered during the pre-bed rest phase of study participation. During the bed rest phase, the WinSCAT test was scheduled every other day, following the centrifuge, for a total of 10 test sessions. (The treatment group received 60 minutes of centrifugation each day during the 21 days of bed rest. The control subjects were strapped to the centrifuge for the same length of time as the treatment group but were not spun.) During the post-bed rest (reconditioning) phase, the test was administered 4 times. Results: Individual differences were found both within and between the treatment and control groups. After controlling for the number of subjects in each group, the treatment group accounted for more off-nominal WinSCAT scores than the control group. Conclusions:There is some preliminary evidence that centrifuge spinning might negatively impact cognitive functioning. However, due to sample size limitations, it cannot be ascertained whether there were significant differences in cognitive performance between the treatment and control groups. If centrifugation had a negative effect on cognitive functioning, consistent decrements would be expected to be found with all treatment subjects across time. Individual differences in underlying cognitive ability and motivation level are other possible explanations for the results found in this study.

Sipes, Walter E.↗

Environmental Physiology at the Johnson Space Center: Past, Present, and Future

This viewgraph presentation reviews the work in environmental physiology done at Johnson Space Center (JSC). The work is aimed at keeping astronauts healthy. This is a different approach than treating the sick, and is more of an occupational health model. The reduction of risks is the main emphasis for this work. They emphasis is to reduce the risk of decompression sickness (DCS) and acute mountain sickness (AMS). The work in environmental physiology encompasses the following areas: (1) Pressure: hypobaric and hyperbaric (2) Gases: hypoxia and hyperoxia, hypercapnia--closed space issues, inert gas physiology / respiration (3) Temperature: hypothermia and hyperthermia, thermal comfort, Protective clothing diving, aviation, mountaineering, and space (4) Acceleration (5) Noise and Vibration (6) Exercise / Performance (6) Acclimatization / Adaptation: engineering solutions when necessary. This presentation reviews the work done at JSC in the areas of DCS and AMS.

Conkin, Johnny↗

Risk Assessment of Physiological Effects of Atmospheric Composition and Pressure in Constellation Vehicles

To reduce denitrogenation time to prevent decompression sickness to support frequent extravehicular activities on the Moon, and to limit the risk of fire, a hypobaric (P(sub B) = 414 mmHg) and mildly hypoxic (ppO2 = 132 mmHg, 32% O2 - 68% N2) living environment is being considered during lunar missions for the Crew Exploration Vehicle (CEV) and Lunar Surface Access Module (LSAM). If the vehicular ppO2 is acutely changed from 145-178 mmHg at standard vehicular operating pressure to less than 125 mmHg at desired lunar surface outpost operating pressures, there is the possibility that some crewmembers may develop symptoms of Acute Mountain Sickness (AMS). The signs and symptoms of AMS (headache plus nausea, dizziness, fatigue, or sleeplessness), could impact crew health and performance on lunar surface missions. Methods: An exhaustive literature review on the topic of the physiological effects of reduced ppO2 and absolute pressure as may contribute to the development of hypoxia and altitude symptoms or AMS. The results of the nine most rigorous studies were collated, analyzed and contents on the physiological concerns associated with hypobaric operations, AMS and hypoxia symptoms summarized. Results: Although space vehicles have operated in hypobaric conditions previously, they have not operated in a mildly hypoxic ppO2. There is evidence for an absolute pressure effect per se on AMS, such that the higher the altitude for a given hypoxic alveolar O2 partial pressure (P(sub A)O2), the greater the likelihood of an AMS response. About 25% of adults are likely to experience mild AMS near 2,000 m (xxx mmHg) altitude following a rapid ascent from sea level while breathing air (6,500 feet, acute (P(sub A)O2) = 75 mmHg). The operational experience with the Shuttle staged denitrogenation protocol at 528 mmHg (3,048 m) while breathing 26.5% O2 (acute (P(sub A)O2) = 85 mmHg) in astronauts adapting to microgravity suggests a similar likely experience in the proposed CEV environment. Conclusions: We feel that the slightly elevated risk of AMS with the recommended exploration atmospheric parameters is offset by the DCS risk reduction and improved operational efficiency offered by the hypobaric lunar surface vehicular pressure. We believe the risk of mild AMS is greater given a (P(sub A)O2) of 77 mmHg at 4,876 m altitude while breathing 32% O2 than at 1,828 m altitude while breathing 21% O2. Only susceptible astronauts would develop mild and transient AMS with prolonged exposure to 414 mmHg (4,876 m) while breathing 32% O2 (acute (P(sub A)O2) = 77 mmHg). So the following may be employed for operational risk reduction: 1) develop procedures to increase P(sub B) as needed in the CEV, and use a gradual or staged reduction in cabin pressure during lunar outbound; 2) train crews for symptoms of hypoxia, to allow early recognition and consider pre-adaptation of crews to a hypoxic environment prior to launch, 3) consider prophylactic acetazolamide for acute pressure changes and be prepared to treat any AMS associated symptoms early with both carbonic anhydrase inhibitors and supplemental oxygen.

Scheuring, Richard A.↗

Sulfur Saturation Limits in Silicate Melts and their Implications for Core Formation Scenarios for Terrestrial Planets

This study explores the controls of temperature, pressure, and silicate melt composition on S solubility in silicate liquids. The solubility of S in FeO-containing silicate melts in equilibrium with metal sulfide increases significantly with increasing temperature but decreases with increasing pressure. The silicate melt structure also exercises a control on S solubility. Increasing the degree of polymerization of the silicate melt structure lowers the S solubility in the silicate liquid. The new set of experimental data is used to expand the model of Mavrogenes and O'Neill(1999) for S solubility in silicate liquids by incorporating the influence of the silicate melt structure. The expected S solubility in the ascending magma is calculated using the expanded model. Because the negative pressure dependence of S solubility is more influential than the positive temperature dependence, decompression and adiabatic ascent of a formerly S-saturated silicate magma will lead to S undersaturation. A primitive magma that is S-saturated in its source region will, therefore, become S-undersaturated as it ascends to shallower depth. In order to precipitate magmatic sulfides, the magma must first cool and undergo fractional crystallization to reach S saturation. The S content in a metallic liquid that is in equilibrium with a magma ocean that contains approx. 200 ppm S (i.e., Earth's bulk mantle S content) ranges from 5.5 to 12 wt% S. This range of S values encompasses the amount of S (9 to 12 wt%) that would be present in the outer core if S is the light element. Thus, the Earth's proto-mantle could be in equilibrium (in terms of the preserved S abundance) with a core-forming metallic phase.

Holzheid, Astrid↗

Experimental Constraints on Ureilite Petrogenesis

This experimental study explores the petrogenesis of ureilites by a partial melting/smelting process. Experiments have been performed over temperature (1150-1280 C), pressure (5-12.5 MPa), and low oxygen fugacity (graphite-CO gas) conditions appropriate for a hypothetical ureilite parent body approximately 200 km in size. Experimental and modeling results indicate that a partial melting/smelting model of ureilite petrogenesis can explain many of the unique characteristics displayed by this meteorite group. Compositional information preserved in the pigeonite-olivine ureilites was used to estimate the composition of melts in equilibrium with the ureilites. The results of 20 experiments saturated with olivine, pyroxene, metal, and liquid with appropriate ureilite compositions are used to calibrate the phase coefficients and pressure-temperature dependence of the smelting reaction. The calibrated coefficients are used to model the behavior of a hypothetical residue that is experiencing fractional smelting. The residue is initially olivine-rich and smelting progressively depletes the olivine content and enriches the pyroxene and metal contents of the residues. The modeled residue composition at 1260 C best reproduces the trend of ureilite bulk compositions. The model results also indicate that as a ureilite residue undergoes isothermal decompression smelting over a range of temperatures, Ca/Al values and Cr203 contents are enriched at lower temperatures (below about 1240 C) and tend to decrease at higher temperatures. Therefore, fractional smelting can account for the high Ca/A1 and Cr203 wt% values observed in ureilites. We propose that ureilites were generated from an olivine-rich, cpx-bearing residue. Smelting began when the residue was partially melted and contained liquid, olivine, and carbon. These residues experienced varying degrees of fractional smelting to produce the compositional variability observed within the pigeonite-bearing ureilites. Variations in mineral composition, modal proportions, and isotopic signatures are best described by heterogeneous accretion of the ureilite parent body followed by minimal and variable degrees of igneous processing.

Singletary, Steven↗

Biomedical Support of U.S. Extravehicular Activity

The world's first extravehicular activity (EVA) was performed by A. A. Leonov on March 18, 1965 during the Russian Voskhod-2 mission. The first US EVA was executed by Gemini IV astronaut Ed White on June 3, 1965, with an umbilical tether that included communications and an oxygen supply. A hand-held maneuvering unit (HHMU) also was used to test maneuverability during the brief EVA; however the somewhat stiff umbilical limited controlled movement. That constraint, plus difficulty returning through the vehicle hatch, highlighted the need for increased thermal control and improved EVA ergonomics. Clearly, requirements for a useful EVA were interrelated with the vehicle design. The early Gemini EVAs generated requirements for suits providing micro-meteor protection, adequate visual field and eye protection from solar visual and infrared radiation, gloves optimized for dexterity while pressurized, and thermal systems capable of protecting the astronaut while rejecting metabolic heat during high workloads. Subsequent Gemini EVAs built upon this early experience and included development of a portable environmental control and life support systems (ECLSS) and an astronaut maneuvering unit. The ECLSS provided a pressure vessel and controller with functional control over suit pressure, oxygen flow, carbon dioxide removal, humidity, and temperature control. Gemini EVA experience also identified the usefulness of underwater neutral buoyancy and altitude chamber task training, and the importance of developing reliable task timelines. Improved thermal management and carbon dioxide control also were required for high workload tasks. With the Apollo project, EVA activity was primarily on the lunar surface; and suit durability, integrated liquid cooling garments, and low suit operating pressures (3.75 pounds per square inch absolute [psia] or 25.8 kilopascal [kPa],) were required to facilitate longer EVAs with ambulation and significant physical workloads with average metabolic rates of 1000 BTU/hr and peaks of up to 2200 BTU/hr. Mobility was further augmented with the Lunar Roving Vehicle. The Apollo extravehicular mobility unit (EMU) was made up of over 15 components, ranging from a biomedical belt for capturing and transmitting biomedical data, urine and fecal containment systems, a liquid cooling garment, communications cap, a modular portable life support system (PLSS), a boot system, thermal overgloves, and a bubble helmet with eye protection. Apollo lunar astronauts performed successful EVAs on the lunar surface from a 5 psia (34.4 kPa) 100% oxygen environment in the Lunar Lander. A maximum of three EVAs were performed on any mission. For Skylab a modified A7LB suit, used for Apollo 15, was selected. The Skylab astronaut life support assembly (ALSA) provided umbilical support through the life support umbilical (LSU) and used open loop oxygen flow, rather than closed-loop as in Apollo missions. Thermal control was provided by liquid water circulated by spacecraft pumps and electrical power also was provided from the spacecraft via the umbilical. The cabin atmosphere of 5 psia (34.4 kPa), 70% oxygen, provided a normoxic atmosphere and because of the very low nitrogen partial pressures, no special protocols were required to protect against decompression sickness (DCS) as was the case with the Apollo spacecraft with a 5 psi, 100% oxygen environment.

Gernhardt, Michael L.↗

Deployment hinge

A hinge (20) includes two hinge plates (22, 24) and a connecting hinge pin (32). A coil spring (48) supported on a bushing (44) overlies the hinge pin (32), which is free to move along its longitudinal axis (30). A cam follower (42) on the hinge pin (32) engages a cam (32) mounted to one of the hinge plates (22), so that the hinge pin (32) slides longitudinally as the hinge plates (22, 24) pivot relative to each other about the hinge pin (32). As the hinge pin (32) slides longitudinally, it axially compresses or decompresses the spring (48). The cam (32) is oriented such that pivoting of the hinge plates (22, 24) in either direction from an open position compresses the spring (48), providing a restoring force which tends to retain the hinge plates (22, 24) in the open position.

Tourville, Thomas↗