Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DC function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Out-of-time ordered correlation functions for the localized 𝑓 electrons in the Falicov-Kimball model

We provide an exact evaluation of the out-of-time correlation (OTOC) functions for the localized 𝑓-particle states in the Falicov-Kimball model within dynamical mean-field theory. Different regimes of quantum chaos and quantum scrambling are distinguished by the winding numbers of the block Toeplitz matrices used in the calculation. The similarities of these fermionic OTOCs and their logarithmic derivatives for time evolution with the OTOCs for quantum spin models with disorder are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control of SiC Based Integrated DC-DC Powertrain Charger for Electric Vehicles

In this paper, an automated controller for an integrated, reconfigurable dc-dc converter for plugin electric vehicles (EVs) is presented. The integrated converter combines both an interleaved boost converter and dual active bridge (DAB) converter, sharing magnetics and switching devices. The converter switches between operating modes using the existing battery management system (BMS) contactors. The integrated converter operates in isolated DAB mode during battery charging operation. During traction operation, the integrated converter is operated in interleaved boost mode for heavy load and DAB mode during light load, high voltage operation. An online transition algorithm is used to transition from interleaved boost mode to DAB mode with minimal bus distortion. The automated controller selects the operating mode and inverter bus voltage at different torque-speed conditions to get maximum overall traction drive efficiency. An experimental prototype of the integrated converter demonstrates the automated controller functionality.

Anwar, Saeed↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Motor control for a brushless DC motor

This invention relates to a motor control system for a brushless DC motor having an inverter responsively coupled to the motor control system and in power transmitting relationship to the motor. The motor control system includes a motor rotor speed detecting unit that provides a pulsed waveform signal proportional to rotor speed. This pulsed waveform signal is delivered to the inverter to thereby cause an inverter fundamental current waveform output to the motor to be switched at a rate proportional to said rotor speed. In addition, the fundamental current waveform is also pulse width modulated at a rate proportional to the rotor speed. A fundamental current waveform phase advance circuit is controllingly coupled to the inverter. The phase advance circuit is coupled to receive the pulsed waveform signal from the motor rotor speed detecting unit and phase advance the pulsed waveform signal as a predetermined function of motor speed to thereby cause the fundamental current waveform to be advanced and thereby compensate for fundamental current waveform lag due to motor winding reactance which allows the motor to operate at higher speeds than the motor is rated while providing optimal torque and therefore increased efficiency.

Peterson, William J.↗

Absence of hindrance in a microscopic 12 C + 12 C fusion study

Studies of low-energy fusion of light nuclei are important in astrophysical modeling, with small variations in reaction rates having a large impact on nucleosynthesis yields. Due to the lack of experimental data at astrophysical energies, extrapolation and microscopic methods are needed to model fusion probabilities. To investigate deep sub-barrier 12 C+ 12 C fusion cross sections and establish trends for the S factor. Microscopic methods based on static Hartree-Fock and time-dependent Hartree-Fock (TDHF) mean-field theory are used to obtain 12 C+ 12 C ion-ion fusion potentials. Fusion cross sections and astrophysical S factors are then calculated using the incoming wave boundary condition method. Both density-constrained frozen Hartree-Fock (DCFHF) and density-constrained TDHF (DC-TDHF) predict a rising S factor at low energies, with DC-TDHF predicting a slight damping in the deep sub-barrier region (≈1 MeV). Comparison between DC-TDHF calculations and maximum experimental cross sections in the resonance peaks are good. However, the discrepancy in experimental low-energy results inhibits interpretation of the trend. Using the fully microscopic DCFHF and DC-TDHF methods, no S factor maximum is observed in the 12 C+ 12 C fusion reaction. In addition, no extreme sub-barrier hindrance is predicted at low energies. Furthermore, the development of a microscopic theory of fusion including resonance effects, as well as further experiments at lower energies must be done before the deep sub-barrier behavior of the reaction can be established.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Behavior of aircraft antiskid braking systems on dry and wet runway surfaces: Hydromechanically controlled system

The investigation utilized one main gear wheel, brake, and tire assembly of a McDonnell Douglas DC-9 series 10 airplane. The landing-gear strut was replaced by a dynamometer. During maximum braking, average braking behavior indexes based upon brake pressure, brake torque, and drag-force friction coefficient developed by the antiskid system were generally higher on dry surfaces than on wet surfaces. The three braking behavior indexes gave similar results but should not be used interchangeably as a measure of the braking of this antiskid sytem. During the transition from a dry to a flooded surface under heavy braking, the wheel entered into a deep skid but the antiskid system reacted quickly by reducing brake pressure and performed normally during the remainder of the run on the flooded surface. The brake-pressure recovery following transition from a flooded to a dry surface was shown to be a function of the antiskid modulating orifice.

Tanner, J. A.↗

A novel priority selection system for nuclear power plant - 287

The priority selection system is an important component of security level instrument control platform for nuclear power plant, the main function of which is priority processing the manual or automatic command with various security levels and driving engineering safety features and field devices, such as pump and valve. Its stability and safety plays a crucial role in the operation of the power plant. The main objective of the present paper is to describe the new nuclear power plant-oriented priority selection system, which is developed independently by China Nuclear Control System Engineering Company. In this system, the control commands from 1E DCS, ECP and DAS systems are transmitted via hardwire, while those from NC DCS are transmitted by field-bus. The control commands experience priority output to control the field actuators. Meanwhile, in order to control key field devices when failure of the instrument control systems occurs, the issuing interface for native instructions with permissions setting is also offered. The whole system provides collection-feedback functions for field devices, high coverage self-diagnostic functions and periodic test functions for safety systems. Moreover, the feedback information of field devices, the results of self-diagnosis and periodic test will be submitted to DCS of nuclear power plant. In addition, the core part of priority selection system, namely priority selection module, is obtained by pure FPGA technology, which is different from DCS systems and could avoid common cause failure of software effectively. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Online Optimization as a Feedback Controller: Stability and Tracking

This paper develops and analyzes feedback-based online optimization methods to regulate the output of a linear time-invariant (LTI) dynamical system to the optimal solution of a time-varying convex optimization problem. The design of the algorithm is based on continuous-time primal-dual dynamics, properly modified to incorporate feedback from the LTI dynamical system, applied to a proximal augmented Lagrangian function. The resultant closed-loop algorithm tracks the solution of the time-varying optimization problem without requiring knowledge of (time-varying) disturbances in the dynamical system. The analysis leverages integral quadratic constraints to provide linear matrix inequality (LMI) conditions that guarantee global exponential stability and bounded tracking error. Analytical results show that, under a sufficient time-scale separation between the dynamics of the LTI dynamical system and the algorithm, the LMI conditions can be always satisfied. The paper further proposes a modified algorithm that can track an approximate solution trajectory of the constrained optimization problem under less restrictive assumptions. As an illustrative example, the proposed algorithms are showcased for power transmission systems, to compress the time scales between secondary and tertiary control, and allow to simultaneously power re-balancing and tracking of DC optimal power flow points.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ATS-6 - UCLA fluxgate magnetometer

A summary of the design of the University of California at Los Angeles' fluxgate magnetometer is presented. Instrument noise in the bandwidth 0.001 to 1.0 Hz is of order 85 m gamma. The DC field of the spacecraft transverse to the earth-pointing axis is 1.0 + or - 21 gamma in the X direction and -2.4 + or - 1.3 gamma in the Y direction. The spacecraft field parallel to this axis is less than 5 gamma. The small spacecraft field has made possible studies of the macroscopic field not previously possible at synchronous orbit. At the 96 W longitude of Applications Technology Satellite-6 (ATS-6), the earth's field is typically inclined 30 deg to the dipole axis at local noon. Most perturbations of the field are due to substorms. These consist of a rotation in the meridian to a more radial field followed by a subsequent rotation back. The rotation back is normally accompanied by transient variations in the azimuthal field. The exact timing of these perturbations is a function of satellite location and the details of substorm development.

Mcpherron, R. L.↗

Antiferromagnetic Resonance and Terahertz Continuum in α - RuCl 3

We report measurements of optical absorption in the zigzag antiferromagnet α-RuCl 3 as a function of temperature T , magnetic field B , and photon energy ℏ ω in the range ~ 0.3 –8.3 meV, using time-domain terahertz spectroscopy. Polarized measurements show that threefold rotational symmetry is broken in the honeycomb plane from 2 to 300 K. We find a sharp absorption peak at 2.56 meV upon cooling below the Néel temperature of 7 K at B = 0 that we identify as the magnetic-dipole excitation of a zero-wave-vector magnon, or antiferromagnetic resonance (AFMR). With the application of B , the AFMR broadens and shifts to a lower frequency as long-range magnetic order is lost in a manner consistent with transitioning to a spin-disordered phase. From a direct, internally calibrated measurement of the AFMR spectral weight, we place an upper bound on the contribution to the dc susceptibility from a magnetic excitation continuum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of Utility Managed Smart Charging for Multiple Benefit Streams (Final Report)

In the summer of 2020, the U.S. Department of Energy (DOE) awarded funding to Exelon’s Maryland utilities—Baltimore Gas and Electric (BGE), Delmarva Power & Light (DPL), and Potomac Electric Power Company (Pepco)—to implement the Smart Charge Management (SCM) pilot. This initiative aimed to design and implement managed electric vehicle (EV) charging strategies, evaluate the grid impacts of EV charging, and assess the utilities' ability to control EV load based on real-time grid conditions. The SCM pilot explored four aspects for continued improvement: (1) cybersecurity and managed charging functionality testing of two vendor platforms—WeaveGrid (telematics-based) and Shell Recharge Solutions (network-based)—which pursued charge scheduling and optimization through distinct approaches; (2) an analysis by Argonne National Laboratory (ANL) modeling team of three potential SCM enrollment scenarios within BGE and Pepco service territories over the next decade to assess future scalability; (3) employing customer engagement strategies, including surveys and a responsive pricing approach; and (4) the launch and implementation of pilots in Exelon’s Maryland territories in collaboration with WeaveGrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Diurnal Ozone Emissions: A Comparative Analysis of DSCOVR EPIC, PANDORA, and TOLNet Data for Space-Based Monitoring Assessment: A Case Study by ASDC

Stratospheric ozone occurs naturally in the upper atmosphere, forming a protective layer that shields us from the sun's harmful ultraviolet rays. Tropospheric ozone is not emitted directly into the air but is created by chemical reactions between nitrogen oxides (NOx) and volatile organic compounds (VOC). This reaction happens when pollutants emitted by cars, power plants, industrial boilers, refineries, chemical plants, and other sources chemically react in sunlight [1]. Therefore, increased levels of tropospheric ozone indicate the presence of pollutants in the air. While daily anthropogenic activity causes an increase of ground-level ozone, variation of stratospheric ozone changes happens much slower, so that variation of the total ozone column reflects the variation of the tropospheric column due to natural, e.g., wildfires and anthropogenic air pollution. Both total and tropospheric ozone column products are used in this study. The reflectance spectra measured by the Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) spacecraft are compared with a set of radiative transfer-derived lookup tables for the EPIC filter transmission functions and a wide range of ozone values to retrieve ozone with a maximum resolution of 18 km at the sub-satellite point [2]. EPIC provides total column ozone in level 2 and level 4 products and tropospheric column ozone in level 4 products. Both EPIC Ozone products [2] are available at the Atmospheric Science Data Center (ASDC) at NASA Langley Research Center [3, 4]. Pandora spectrometer instrument measures columnar amounts of trace gases in the atmosphere. These gases (O3, NO2, CH2O) absorb light from the sun at specific wavelengths in the ultraviolet-visible spectrum [5]. Using the theoretical solar spectrum as a reference, Pandora determines trace gas amounts using differential optical absorption spectroscopy (DOAS). Pandora ozone retrievals are available from the Pandonia Global Network [6]. Pandora data from North American major metropolitan areas, New York, NY, Washington DC, Los Angeles, CA, and Mexico City. Tropospheric Ozone Lidar Network (TOLNet) was established in 2012 to provide high spatiotemporal observations of tropospheric ozone to (1) better understand physical processes driving the ozone budget in various meteorological and environmental conditions and (2) validate the tropospheric ozone measurements of space-borne missions [7]. TOLNet data are available at ASDC [8]. While EPIC provides global coverage of ozone retrievals several times daily, temporal resolution may miss some features in daily ozone variations. Ground-based sensors such as Pandora spectrometers and TOLNet lidars provide better temporal resolution while missing continuous spatial coverage. The forthcoming ozone retrieval from the TEMPO mission [9] will provide better spatial and temporal coverage of air quality (including ozone) over North America. This study investigates whether EPIC ozone products can detect diurnal air quality variations and compare ozone temporal development with retrieval by ground-based instruments.

diurnal ozone emissions, DSCOVR EPIC, PANDORA, spa↗

Multiscale Modeling Framework Using Element‐Based Galerkin Methods for Moist Atmospheric Limited‐Area Simulations

This paper presents a multiscale modeling framework (MMF) to model moist atmospheric limited-area weather. The MMF resolves large-scale convection using a coarse grid while simultaneously resolving local features through numerous fine local grids and coupling them seamlessly. Both large- and small-scale processes are modeled using the compressible Navier-Stokes equations within the Nonhydrostatic Unified Model of the Atmosphere (NUMA), and are discretized using a continuous element-based Galerkin method (spectral elements) with high-order basis functions. Consequently, the large-scale and small-scale models share the same dynamical core but have the flexibility to be adjusted individually. The proposed MMF method is tested in 2D and 3D idealized limited-area weather problems involving storm clouds produced by squall line and supercell simulations. Numerical results from the MMF showed enhanced representation of cloud processes compared to the coarse model.

Kang, Soonpil [Naval Postgraduate School, Monterey↗

Magnetic Field Measurement on the C/NOFS Satellite: Geomagnetic Storm Effects in the Low Latitude Ionosphere

The Vector Electric Field Investigation (VEFI) suite onboard the Communications/Navigation Outage Forecasting System (C/NOFS) spacecraft includes a sensitive fluxgate magnetometer to measure DC and ULF magnetic fields in the low latitude ionosphere. The instrument includes a DC vector measurement at 1 sample/sec with a range of +/- 45,000 nT whose primary objective is to provide direct measurements of both V x B and E x B that are more accurate than those obtained using a simple magnetic field model. These data can also be used for scientific research to provide information of large-scale ionospheric and magnetospheric current systems, which, when analyzed in conjunction with the C/NOFS DC electric field measurements, promise to advance our understanding of the electrodynamics of the low latitude ionosphere. In this study, we use the magnetic field data to study the temporal and local time variations of the ring currents during geomagnetic storms. We first compare the in situ measurements with the POMME (the POtsdam Magnetic Model of the Earth) model in order to provide an in-flight "calibration" of the data as well as compute magnetic field residuals essential for revealing large scale external current systems. We then compare the magnetic field residuals observed both during quiet times and during geomagnetic storms at the same geographic locations to deduce the magnetic field signatures of the ring current. As will be shown, the low inclination of the C/NOFS satellite provides a unique opportunity to study the evolution of the ring current as a function of local time, which is particularly insightful during periods of magnetic storms. This paper will present the initial results of this study.

Le, Guan↗

Development of a Supervisory Tool for Fault Detection and Diagnosis of DC Electric Power Systems with the Application of Deep Space Vehicles

This dissertation formulates the problem of fault detection and diagnosis of DC electric power systems for the application of autonomous spacecraft. The ability to accurately identify and isolate failures in the electrical power system is critical to ensure the reliability of a spacecraft. This problem becomes more pronounced during deep space missions that lack the ability to monitor from ground control. The current state of electrical power system fault supervision is insufficient to guarantee highly reliable and robust operation. To solve this issue, a combination of model-based and rules-based techniques are used in a hierarchical framework to improve the diagnostic performance of the spacecraft electrical power system. Noise, disturbances, and modeling errors are considered in the design of the method. Practical considerations related to the hardware and software are discussed for the flight application. A wide array of failure types are simulated in a series of experiments to assess the functionality of the design. The experiments showed that the methods used improved the diagnostic capability of the autonomous system while taking into account the limitations attributed to flight software requirements. The significance of this study is to provide a framework capable of advanced diagnostics of an electrical power system with little to no interaction from a human operator.

Fault Detection and Diagnosis↗

An LED Approach for Measuring the Photocatalytic Breakdown of Crystal Violet Dye

A simple technique to assess the reactivity of photocatalytic coatings sprayed onto transmissive glass surfaces was developed. This new method uses ultraviolet (UV) gallium nitride (GaN) light-emitting diodes (LEDs) to drive a photocatalytic reaction (the photocatalytic breakdown of a UV-resistant dye applied to a surface coated with the semiconductor titanium dioxide); and then a combination of a stabilized white light LED and a spectrometer to track the dye degradation as a function of time. Simple, standardized evaluation techniques that assess photocatalytic materials over a variety of environmental conditions, including illumination level, are not generally available and are greatly needed prior to in situ application of photocatalytic technologies. To date, much research pertaining to this aspect of photocatalysis has been limited and has focused primarily on laboratory experiments using mercury lamps. Mercury lamp illumination levels are difficult to control over large ranges and are temporally modulated by line power, limiting their use in helping to understand and predict how photocatalytic materials will behave in natural environmental settings and conditions. The methodology described here, using steady-state LEDs and time series spectroradiometric techniques, is a novel approach to explore the effect of UV light on the photocatalytic degradation of a UV resistant dye (crystal violet). GaN UV LED arrays, centered around 365 nm with an adjustable DC power supply, are used to create a small, spatially uniform light field where the steady state light level can be varied over three to four orders of magnitude. For this study, a set of glass microscope slides was custom coated with a thinly sprayed layer of photocatalytic titanium dioxide. Crystal violet was then applied to these titanium-dioxide coated slides and to uncoated control slides. The slides were then illuminated at various light levels from the dye side of the slide by the UV LED array. To monitor dye degradation on the slides over time, a temperature-stabilized white light LED was used to illuminate the opposite side of the slides. As the dye degraded, the amount of light from the white light LED transmitted through the slide was monitored with a spectrometer and subsequently analyzed to determine and compare the rate of dye degradation for photocatalytically coated versus uncoated slide surfaces. The long-term stability of the spectrometer/white light LED combination, which required only a single reference spectra to be taken for a time series sequence of several hours, enabled accurate measurements of transmitted light over time. Time series transmission curves were generated and results demonstrated that over time the transmission increased much more rapidly on the coated slides than on the control slides. This experimental configuration and methodology for photocatalytic activity measurement minimizes many external variable effects and allows low light level studies to be performed. This study also compares the advantages of this novel LED light source design to traditional mercury lamp systems and non-LED lamp approaches that have conventionally been used. The methodology and experimental design research summarized in this abstract is partly funded by the Department of Homeland Security, Science and Technology Directorate, and by the NASA Stennis Space Center Innovative Partnerships Program.

Ryan, Robert E.↗

Oak Ridge National Laboratory Current Magnitude and Frequency Response of SIPROTEC Relays

This project examined the current magnitude and frequency response of 7SJ61 and 7SJ62 SIPROTEC relays. The measured sample frequencies for the 7SJ61 and 7SJS62 relays were 800 and 960 Hz, respectively. The relays were tested at frequencies of up to 1 and 20.16 kHz. Two experiments were run in a lab environment. The first experiment was run at frequencies of up to 1 kHz every 10 Hz. The second one was run at frequencies of up to 20.16 kHz every 200 and 240 Hz (common factors of sample rate frequency) for the 7SJ61 and 7SJ62 SIPROTEC relays, respectively. Both experiments were set at a current magnitude of 0.1 and 0.5 Arms. A testbed with a Relay Test Equipment (RTE) was set to run the experiment at frequencies of up to 1 kHz, while a testbed with a RTE and High Frequency Power Source/ Amplifier (HFPS/A) was set to run at frequencies of up to 20.16 kHz. Currents of 0.1 and 0.5 Arms at different frequencies were connected at Phase A of the relays, and a current of 1 Arms (60 Hz) was connected at Phase B of relays. The 1 Arms current allowed the relays to trip and saved their record events by setting both relays at a definite-time overcurrent protection function. The record events were collected after the 7SJ61 and 7SJ62 relays tripped, and the current magnitude and frequency were plotted. The record events from the relays were collected using the DIGSI® 4 software. The SYNCHROWAVE® Event and MATLAB® software were then used to plot the current magnitude and frequency, respectively, from the relay record events. The current magnitude and frequency were plotted at time and frequency domain, respectively.The 7SJ61 and 7SJ62 relays measured source frequencies of up to 400 and 480 Hz, respectively. The percentage error of frequency for the relays increased after 400 and 480 Hz, respectively. The 7SJ62 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1440 Hz. The 7SJ61 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1000 and 1200 Hz, respectively. At frequencies higher than the alias frequency, the relays measured a DC amplitude current instead of an AC amplitude current. In the DC amplitude current zone, non-desired frequencies were measured by both relays. The current magnitude intensity (dB) for the 7SJ61 and 7SJ62 relays from 1 to 20.16 kHz were plotted. The current magnitude intensity for the 7SJ61 relay decreased up to 2600 and 1200 Hz for 0.5 and 0.1 Arms tests, respectively. However, the current magnitude intensity for the 7SJ62 relay decreased up to 4800 and 2640 Hz for 0.5 and 0.1 Arms tests, respectively. The current magnitude and frequency response study for the 7SJ61 and 7SJ62 relays was performed satisfactorily, observing the source, alias, and non-desired measured frequency zones for both relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Space Station module Power Management And Distribution (PMAD) system

This project consists of several tasks which are unified toward experimentally demonstrating the operation of a highly autonomous, user-supportive power management and distribution system for Space Station Freedom (SSF) habitation/laboratory modules. This goal will be extended to a demonstration of autonomous, cooperative power system operation for the whole SSF power system through a joint effort with NASA's Lewis Research Center, using their Autonomous Power System. Short term goals for the space station module power management and distribution include having an operational breadboard reflecting current plans for SSF, improving performance of the system communications, and improving the organization and mutability of the artificial intelligence (AI) systems. In the middle term, intermediate levels of autonomy will be added, user interfaces will be modified, and enhanced modeling capabilities will be integrated in the system. Long term goals involve conversion of all software into Ada, vigorous verification and validation efforts and, finally, seeing an impact of this research on the operation of SSF. Conversion of the system to a DC Star configuration is now in progress, and should be completed by the end of October, 1989. This configuration reflects the latest SSF module architecture. Hardware is now being procured which will improve system communications significantly. The Knowledge-Based Management System (KBMS) is initially developed and the rules from FRAMES have been implemented in the KBMS. Rules in the other two AI systems are also being grouped modularly, making them more tractable, and easier to eventually move into the KBMS. Adding an intermediate level of autonomy will require development of a planning utility, which will also be built using the KBMS. These changes will require having the user interface for the whole system available from one interface. An Enhanced Model will be developed, which will allow exercise of the system through the interface without requiring all of the power hardware to be operational. The functionality of the AI systems will continue to be advanced, including incipient failure detection. Ada conversion will begin with the lowest level processor (LLP) code. Then selected pieces of the higher level functionality will be recorded in Ada and, where possible, moved to the LLP level. Validation and verification will be done on the Ada code, and will complete sometimes after completion of the Ada conversion.

Walls, Bryan↗