Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Pyroclast cooling and saturation in water

In the submarine setting pyroclast cooling and saturation, by controlling the buoyancy of individual clasts and surrounding fluid, exert fundamental controls on the dispersal and fate of volcanic material. Here, we use laboratory experiments to understand and quantify how hot and air-filled pyroclasts cool and saturate in liquid water. By measuring internal temperature and clast submerged weight in over thirty experiments, we find that pumice cools and saturates in two stages. We observe that the first stage is marked by much higher rates of cooling and saturation than the second stage and that the transition between stages is sharp. We propose conceptual and quantitative models for each stage of pyroclast cooling and saturation. Specifically we argue that the first stage is defined by the presence of internal steam. That is, hot pyroclasts ingest liquid water and generate steam. Once a clast's internal pore space is filled with steam, heat loss to the surroundings causes condensation of internal vapor and clast saturation. Stage 1 ends when all internal steam has condensed. We test this idea with a Stefan Model with advection and conclude that heat loss, rather than permeability, controls the saturation of pyroclasts above the boiling temperature. We find that permeability matters for air-filled clasts with initial temperatures below the boiling point. Stage 2 begins after all internal vapor has condensed and we propose that stage 2 cooling and saturation are controlled by heat conduction and thermal contraction of trapped gas, respectively. From our understanding of the processes that govern the stage 1 to 2 transition, we derive an empirical average pyroclast cooling rate of q = 7.5 ± 0.5 W cm -2 . Finally, we develop quantitative models for cooling-controlled porous clast saturation and for buoyant clast rise to the ocean surface. We find that meter size clasts stay buoyant for more than 10 min - long enough to reach the surface from a depth of 1000 m. Lastly, the models developed here test our understanding of clast-scale processes and demonstrate that - in hot and porous clasts - the details of internal texture do not matter because clast saturation, and thus buoyancy and fate in the water column, are governed by heat transfer.

58 GEOSCIENCES↗

Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling

With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circumventing the phonon bottleneck by multiphonon-mediated hot exciton cooling at the nanoscale

Abstract Nonradiative processes govern efficiencies of semiconductor nanocrystal (NC)-based devices. A central process is hot exciton cooling, or the nonradiative relaxation of a highly excited electron/hole pair to form a band-edge exciton. Due to quantum confinement effects, the timescale and mechanism of cooling are not well understood. A mismatch between electronic energy gaps and phonon frequencies has led to the hypothesis of a phonon bottleneck and extremely slow cooling, while enhanced electron-hole interactions have suggested ultrafast cooling. Experimental measurements of the cooling timescale range six orders of magnitude. Here, we develop an atomistic approach to describe phonon-mediated exciton dynamics and simulate cooling in NCs of experimentally relevant sizes. We find that cooling occurs on ~30 fs timescales in CdSe NCs, in agreement with the most recent measurements, and that the phonon bottleneck is circumvented through a cascade of multiphonon-mediated relaxation events. Furthermore, we identify NC handles for tuning the cooling timescale.

36 MATERIALS SCIENCE↗

Laser cooling of antihydrogen atoms

The photon—the quantum excitation of the electromagnetic field—is massless but carries momentum. A photon can therefore exert a force on an object upon collision 1 . Slowing the translational motion of atoms and ions by application of such a force 2,3 , known as laser cooling, was first demonstrated 40 years ago 4,5 . It revolutionized atomic physics over the following decades 6–8 , and it is now a workhorse in many fields, including studies on quantum degenerate gases, quantum information, atomic clocks and tests of fundamental physics. However, this technique has not yet been applied to antimatter. Here we demonstrate laser cooling of antihydrogen 9 , the antimatter atom consisting of an antiproton and a positron. By exciting the 1S–2P transition in antihydrogen with pulsed, narrow-linewidth, Lyman-α laser radiation 10,11 , we Doppler-cool a sample of magnetically trapped antihydrogen. Although we apply laser cooling in only one dimension, the trap couples the longitudinal and transverse motions of the anti-atoms, leading to cooling in all three dimensions. We observe a reduction in the median transverse energy by more than an order of magnitude—with a substantial fraction of the anti-atoms attaining submicroelectronvolt transverse kinetic energies. We also report the observation of the laser-driven 1S–2S transition in samples of laser-cooled antihydrogen atoms. The observed spectral line is approximately four times narrower than that obtained without laser cooling. The demonstration of laser cooling and its immediate application has far-reaching implications for antimatter studies. A more localized, denser and colder sample of antihydrogen will drastically improve spectroscopic 11–13 and gravitational 14 studies of antihydrogen in ongoing experiments. Furthermore, the demonstrated ability to manipulate the motion of antimatter atoms by laser light will potentially provide ground-breaking opportunities for future experiments, such as anti-atomic fountains, anti-atom interferometry and the creation of antimatter molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE ORIGIN OF THE EXTENDED H{alpha} FILAMENTS IN COOLING FLOW CLUSTERS

We present a high spatial resolution H{alpha} survey of 23 cooling flow clusters using the Maryland Magellan Tunable Filter, covering 1-2 orders of magnitude in cooling rate, dM/dt, temperature, and entropy. We find that 8/23 (35%) of our clusters have complex, filamentary morphologies at H{alpha}, while an additional 7/23 (30%) have marginally extended or nuclear H{alpha} emission, in general agreement with previous studies of line emission in cooling flow cluster brightest cluster galaxies. A weak correlation between the integrated near-UV luminosity and the H{alpha} luminosity is also found for our complete sample with a large amount of scatter about the expected relation for photoionization by young stars. We detect H{alpha} emission out to the X-ray cooling radius, but no further, in several clusters and find a strong correlation between the H{alpha} luminosity contained in filaments and the X-ray cooling flow rate of the cluster, suggesting that the warm ionized gas is linked to the cooling flow. Furthermore, we detect a strong enhancement in the cooling properties of the intracluster medium (ICM) coincident with the H{alpha} emission, compared to the surrounding ICM at the same radius. While the filaments in a few clusters may be entrained by buoyant radio bubbles, in general, the radially infalling cooling flow model provides a better explanation for the observed trends. The correlation of the H{alpha} and X-ray properties suggests that conduction may be important in keeping the filaments ionized. The thinness of the filaments suggests that magnetic fields are an important part of channeling the gas and shielding it from the surrounding hot ICM.

79 ASTRONOMY AND ASTROPHYSICS↗

SELF-CONVERGENCE OF RADIATIVELY COOLING CLUMPS IN THE INTERSTELLAR MEDIUM

Isolated regions of higher density populate the interstellar medium (ISM) on all scales-from molecular clouds, to the star-forming regions known as cores, to heterogeneous ejecta found near planetary nebulae and supernova remnants. These clumps interact with winds and shocks from nearby energetic sources. Understanding the interactions of shocked clumps is vital to our understanding of the composition, morphology, and evolution of the ISM. The evolution of shocked clumps is well understood in the limiting 'adiabatic' case where physical processes such as self-gravity, heat conduction, radiative cooling, and magnetic fields are ignored. In this paper, we address the issue of evolution and convergence when one of these processes-radiative cooling-is included. Numeric convergence studies demonstrate that the evolution of an adiabatic clump is well captured by roughly 100 cells per clump radius. The presence of radiative cooling, however, imposes limits on the problem due to the removal of thermal energy. Numerical studies which include radiative cooling typically adopt the 100-200 cells per clump radius resolution. In this paper, we present the results of a convergence study for radiatively cooling clumps undertaken over a broad range of resolutions, from 12 to 1536 cells per clump radius, employing adaptive mesh refinement (AMR) in a two-dimensional axisymmetric geometry (2.5 dimensions). We also provide a fully three-dimensional simulation, at 192 cells per clump radius, which supports our 2.5 dimensional results. We find no appreciable self-convergence at {approx}100 cells per clump radius as small-scale differences owing to increasingly resolving the cooling length have global effects. We therefore conclude that self-convergence is an insufficient criterion to apply on its own when addressing the question of sufficient resolution for radiatively cooled shocked clump simulations. We suggest the adoption of alternate criteria to support a statement of sufficient resolution, such as the demonstration of adequate resolution of the cooling layers behind shocks. We discuss associated refinement criteria for AMR codes.

79 ASTRONOMY AND ASTROPHYSICS↗

A VERY DEEP CHANDRA OBSERVATION OF A1795: THE COLD FRONT AND COOLING WAKE

We present a new analysis of very deep Chandra observations of the galaxy cluster A1795. Utilizing nearly 750 ks of net ACIS imaging, we are able to resolve the thermodynamic structure of the intracluster medium (ICM) on length scales of ∼1 kpc near the cool core. We find several previously unresolved structures, including a high pressure feature to the north of the Brightest Cluster Galaxy (BCG) that appears to arise from the bulk motion of A1795's cool core. To the south of the cool core, we find low temperature (∼3 keV), diffuse ICM gas extending for distances of ∼50 kpc spatially coincident with previously identified filaments of Hα emission. Gas at similar temperatures is also detected in adjacent regions without any Hα emission. The X-ray gas coincident with the Hα filament has been measured to be cooling spectroscopically at a rate of ∼1 M{sub ⊙} yr{sup −1}, consistent with measurements of the star formation rate in this region as inferred from ultraviolet (UV) observations, suggesting that the star formation in this filament as inferred by its Hα and UV emission can trace its origin to the rapid cooling of dense, X-ray emitting gas. The Hα filament is not a unique site of cooler ICM, however, as ICM at similar temperatures and even higher metallicities not cospatial with Hα emission is observed just to the west of the Hα filament, suggesting that it may have been uplifted by A1795's central active galaxy. Further simulations of cool core sloshing and active galactic nucleus feedback operating in concert with one another will be necessary to understand how such a dynamic cool core region may have originated and why the Hα emission is so localized with respect to the cool X-ray gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimized pulsed sideband cooling and enhanced thermometry of trapped ions

Resolved sideband cooling is a standard technique for cooling trapped ions below the Doppler limit to near their motional ground state. Yet the most common methods for sideband cooling implicitly rely on low Doppler-cooled temperatures and tightly confined ions and they cannot be optimized for different experimental conditions. Here we introduce a framework which calculates the fastest possible pulsed sideband cooling sequence for a given number of pulses and set of experimental parameters and we verify its improvement compared to traditional methods using a trapped 171 Yb + ion. After extensive cooling, we find that the ion motional distribution is distinctly nonthermal and thus not amenable to standard thermometry techniques. We therefore develop and experimentally validate an improved method to measure ion temperatures after sideband cooling. These techniques will enable more efficient cooling and thermometry within trapped-ion systems, especially those with high initial temperatures or spatially extended ion wave packets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rapid cooling of the in-plane motion of two-dimensional ion crystals in a Penning trap to millikelvin temperatures

Here, we propose a highly feasible technique with no experimental overhead to rapidly cool the in-plane degrees of freedom of large two-dimensional ion crystals in Penning traps. Through simulations, we demonstrate that our approach enables the in-plane modes to cool down to a temperature of around 1 mK in less than 10 ms. Our technique relies on near-resonant coupling of the poorly cooled in-plane motions and the efficiently cooled out-of-plane motions, and is achieved without introducing additional potentials. The rapid cooling enabled by our approach is in contrast to typical operating conditions, where our simulations of the laser cooling dynamics suggest that the ion crystal's in-plane motion cools very slowly on a timescale of several hundreds of milliseconds, a rate likely slower than experimental heating rates. Our work sets the stage for sub-Doppler laser cooling of the planar motion, and more robust and versatile quantum simulation and quantum sensing experiments with two-dimensional crystals in Penning traps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Surface Heater Fabrication Using Micro-Lithography for Transpiration Cooling Heat Transfer Coefficient Measurements

Abstract Transpiration cooling is able to provide more uniform coolant coverage than film cooling to effectively protect the component surface from contacting the hot gas. Due to numerous coolant ejection outlets within a small area at the target surface, the experimental thermo-fluid investigation on transpiration cooling becomes a significant challenge. Two classic methods to investigate film cooling, the steady-state foil heater method and the transient thermography technique, fail for transpiration cooling because the foil heater would block numerous coolant outlets, and the semi-infinite solid conduction model no longer holds for porous plates. In this study, a micro-lithography method to fabricate a silver coil pattern on top of the additively manufactured polymer porous media as the surface heater was proposed. The circuit was deliberately designed to cover the solid surface in a combination of series connection, and parallel connection to ensure the power in each unit cell area at the target surface was identical. With uniform heat flux generation, the steady-state tests were conducted to obtain distributions of a pair of parameters, adiabatic cooling effectiveness, and heat transfer coefficient (HTC). The results showed that the adiabatic cooling effectiveness could reach 0.65 with a blowing ratio lower than 0.5. Meanwhile, the heat transfer coefficient ratio (hf/h0) of transpiration cooling was close to 1 with a small blowing ratio at 0.125. A higher HTC ratio was observed for smaller pitch-to-diameter cases due to more turbulence intensity generated at the target surface.

Engineering↗

Printability and Overall Cooling Performance of Additively Manufactured Holes With Inlet and Exit Rounding

Abstract To improve cooling effectiveness of gas turbine hardware, various film cooling hole shapes have previously been researched. Unique design modifications have recently been made possible through the design freedom allotted by additive manufacturing (AM). As one example, creating a rounded inlet for a film-cooling hole can mitigate separation at the inlet. This study explores various geometric features by exploiting the uses of additive manufacturing for shaped film cooling holes at engine scale. Both printability and cooling performance were evaluated. Resulting from this study, additively manufactured holes with hole inlet and exit rounding were printed with some variations from the design intent (DI). The largest deviations from the design intent occurred from dross roughness features located on the leeward side of the hole inlet. The measured overall effectiveness indicated that an as-built inlet fillet decreased in-hole convection as well as decreased jet mixing compared to the as-built sharp inlet. Including an exit fillet, which prevented an overbuilt diffuser exit, was also found to decrease jet mixing. A particular insight gained from this study is the importance of the convective cooling within the hole to the overall cooling performance. In-hole roughness, which is a result of additive manufacturing, increased convective cooling within the holes but also increased jet mixing as the coolant exited the hole. The increased jet mixing caused low overall effectiveness downstream of injection.

Engineering↗

SU-C-213-07: Fabrication and Testing of a 3D-Printed Small Animal Rectal Cooling Device to Evaluate Local Hypothermia as a Radioprotector During Prostate SBRT

Purpose: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to SBRT treatments. Relevant to prostate SBRT, this work details the fabrication and testing of a 3D-printed cooling device to facilitate the investigation of the radioprotective effect of local hypothermia on the rat rectum. Methods: A 3cm long, two-channel rectal cooling device was designed in SOLIDWORKS CAD for 3D printing. The water intake nozzle is connected to a 1mm diameter brass pipe from which water flows and circulates back around to the exit nozzle. Both nozzles are connected by plastic tubing to a water chiller pump. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within a rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. CBCT images from a small-animal irradiator were evaluated for imaging artifacts which could affect Monte Carlo dose calculations during treatment planning. Results: The rectal temperature adjacent to the cooling device decreased from body temperature (37°C) to 15°C in 10–20 minutes from device insertion. Rectal temperature was maintained at 15±3°C during active cooling. MRI thermometry tests revealed a steep temperature gradient with increasing distance from the cooling device, with the desired temperature range maintained within the surrounding few millimeters. Conclusion: A 3D printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in rat rectums. Rectal cooling capabilities were characterized in-vivo to facilitate an investigation of the radioprotective effect of hypothermia for late rectal toxicity following a single large dose of radiation. Funding support provided by RSNA research seed grant.

60 APPLIED LIFE SCIENCES↗

The MICE Demonstration of Muon Ionization Cooling

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions up to several TeV at the Muon Collider. The international Muon Ionization Cooling Experiment (MICE) will demonstrate muon ionization cooling, the technique proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam traverses a material (the absorber) loosing energy, which is replaced using RF cavities. The combined effect is to reduce the transverse emittance of the beam (transverse cooling). The configuration of MICE required to deliver the demonstration of ionization cooling is being prepared in parallel to the execution of a programme designed to measure the cooling properties of liquid-hydrogen and lithium hydride. The design of the cooling-demonstration experiment will be presented together with a summary of the performance of each of its components and the cooling performance of the experiment.

43 PARTICLE ACCELERATORS↗

Development of an Active, Man-Portable, Cooling System with Dehumidification Capabilities for Personal Protective Clothing/Equipment

Mainstream Engineering Corporation completed a highly successful SBIR program, during which we developed and commercialized products for microclimate cooling systems (MCS) and the heating, ventilation, air-conditioning, and refrigeration (HVAC/R) industry. We are marketing the MCS family of products for use with personal protective clothing/equipment (PPC/PPE) for firefighters, workers in clean rooms, HAZMAT response and other contamination/remediation teams, and military personnel that are required to wear Mission-Oriented Protective Posture (MOPP) suits and bomb disposal suits. Workers in these industries risk heat stress when confined within protective garments while in hot and humid environments. Our family of MCS and HVAC/R products that resulted from this SBIR program includes: 1. Active, Man-Portable, MCS for PPC/E—Our active system provides 350 W cooling of personal cooling for workers in thermally stressed environments. Although industrially hardened, this system is compact (0.69 ft 3 ) and lightweight (22.9 lbs). The MSC is easily decontaminated or disposed of between uses. 2. Miniature Screw Compressor for MCS—Our 350 Wcooling miniature screw compressor was originally designed for MCS and personal cooling systems. Occupying only 11 in 3 and weighing 1.4 lbs, the size and weight are less than any commercially available compressor with a similar cooling capacity. This miniature screw compressor is marketable as a low-pressure compressor or refrigerant pump. 3. Miniature Sliding Vane Compressor and Drive for MCS—Our 350 Wcooling compressor subassembly consists of a commercial miniature sliding vane compressor packaged with our motor controller. At 29.4 in3 and 1.5 lbs, this compressor is larger and heavier than the miniature screw but is lower cost and capable of producing higher head pressure. 4. Small Screw Compressor for HVAC/R—Our 50 kW cooling small screw compressor is for commercial HVAC/R applications. This compressor is extremely power dense at 0.34 ft 3 and 43 lbs and has a specific cooling capacity (kW/lb) five times greater than existing commercial compressors. We demonstrated high reliability (>5,100 hrs of operation and >3,400 on/off cycles), and we are currently discussing commercialization opportunities with laser manufacturers for cooling of their high-power devices. This final report summarizes the design, fabrication, testing, features, and benefits of each product. The commercialization potential and recommendations for the future are included.

42 ENGINEERING↗

Cooling Performance Testing of Attaway's Negative Pressure CDU

Attaway is a recently installed High-Performance Computing (HPC) machine at Sandia National Labs that is 70% water-cooled and 30% air-cooled. This machine, supplied by Penguin Computing, uses a novel new cooling system from Chilldyne that operates in a vacuum, preventing water leaks. If water-cooling is to fail, fans inside of each node will ramp up to do 100% of the cooling on Attaway. Various tests were completed on Attaway to determine the robustness of its cooling system as well as its ability to respond to sudden changes in states. These changes include an immediate change from an idle compute load to full load (Linpack) as well as running Linpack without any water cooling from Attaway's CDUs. It was discovered that Attaway could respond to sudden compute load changes very well, never throttling any nodes. When Linpack was run without water cooling, the system was able to operate for a short time before throttling happened.

42 ENGINEERING↗

Final Cooling with Thick Wedges for a Muon Collider

A muon collider is a particle accelerator that collides muons rather than protons or electrons. An important component of such a collider is cooling, in which the emittance of the muon beam is reduced to make it suitable for use in a collider. In the last stage of this process, called final 4D cooling, emittance in the transverse axes is reduced while emittance in the longitudinal axis is allowed to grow. In previous studies, Final 4-D cooling used absorbers within very high field solenoids to cool low-momentum muons. Simulations of the systems did not reach the desired cooling design goals. In this study, we develop and optimize a different conceptual design for the final 4D cooling channel, which is based on single thick wedges. We used G4Beamline to simulate the channel and Python to generate and analyze particle distributions. We characterized the effects of various parameters on the performance of this system, including the initial emittances and Twiss parameters, the length and angle of the wedges, the length of the drift channel, and the length, frequency, gradient, and phase of the RF cavities. We optimized the design parameters of the cooling channel and produced two conceptual designs (corresponding to two possible starting points for the input beam) which achieve transverse cooling in both x and y by a factor of ≈ 3.5. These channels achieve a lower transverse and longitudinal emittance than the best design previously published.

43 PARTICLE ACCELERATORS↗

Cool GTL - A New Biogas Conversion Process from GTI

GTI is currently developing the Cool GTL process, to convert biogas into jet fuel. Cool GTL can be used to convert any biogas stream or high CO2 content natural gas to high quality liquid fuels. In Cool GTL we convert high CO2 feeds to synthesis gas at a 2-2.4/1 H2/CO ratio using a novel CO2/steam reforming catalyst which has high stability. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, for a variety of levels of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no deactivation. The product from the reformer then goes directly to a low temperature bubbling fluid bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas, With this configuration no wax is produced. The fluid bed allows excellent temperature control. Cool GTL is under development but still requires longer integrated testing. Currently Cool GTL is being developed at GTI through DOE funding in the project “Cool GTL for the Production of Jet Fuel from Biogas”. In this DOE project, our goal is to make 100 gallons of high quality jet fuel. This project will also demonstrate Cool GTL catalyst and process stability through long term, 24 hour operation. Once the DOE project is complete, we believe the Cool GTL process will be ready for larger scale commercial deployment in multiple applications.

09 BIOMASS FUELS↗