Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Converters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Fault detection in a three-phase dab converter

A system and method of fault detection based on a detailed waveform analysis is presented for transient and steady-state fault operation of 3-Φ DAB converter. Main symptoms of the converter during normal and fault conditions have been identified and a unique pattern in DC bias of phase currents under fault mode is noted. The logic-based fault diagnosis scheme is used to detect the fault and identify the faulty transistor.

Rastogi, Sagar K.↗

Per-Phase Control for CHB Converters with Negative-Sequence Current and DC Voltage Balancing Control

This paper presents a per-phase controller for a grid-connected Cascaded H-Bridge (CHB) converter featuring negative sequence current regulation and DC bus voltage balancing capabilities. Unlike conventional three-phase controllers, each phase of the CHB can be separately and controlled to regulate the DC voltage and reactive power flow. per-phase negative sequence current control strategy is incorporated into the proposed controller to ensure compliance with IEEE Standard 2800-2022, which requires the absorption of negative-sequence reactive current during grid voltage disturbances. Furthermore, a feed-forward control-based DC bus voltage balancing method is employed, which eliminates the need for the integrator commonly used in traditional approaches. The performance of the proposed controller is validated under various unbalanced grid scenarios and DC bus voltage imbalances through electromagnetic transient (EMT) simulation using a three-phase, three-level grid-connected CHB–Dual Active Bridge (DAB) converter testbed developed on MATLAB/Simulink. Additionally, the performance of the negative-sequence current regulation is investigated through simulation under different unbalanced grid voltage scenarios.

negative sequence current↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched AC-DC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

High temperature steam electrolysis↗

A Generic Two-Vector Model Predictive Control for Hybrid Multilevel Converters

In this article, a generic two-vector model predictive control (TV-MPC) strategy is proposed for the hybrid multilevel converters (HMCs). The proposed method selects two optimal voltage vectors among all the vector candidates using a geometric positioning approach to reduce the computational burden, which is a common issue in the existing MPC methods for HMC. Then duty cycles of the two selected vectors are optimized to minimize the current tracking error, such that the current tracking performance can be enhanced compared with the conventional MPC. In addition, the voltages of the floating dc capacitors can be balanced by evaluating all switching sequences that belong to the optimal voltage vectors with optimal duty cycles. Here, the concept of the proposed TV-MPC is generic and applicable for any HMCs. A typical HMC based on active neutral-point-clamped topology is adopted as a case study in this work. Comprehensive simulation and experimental studies are performed on an all silicon-carbide HMC prototype to validate the effectiveness of the proposed control scheme.

42 ENGINEERING↗

Operation of Dual-T-Type Modular Multilevel Converter for Uninterrupted Power Supply Under Bridge Failures

Dual-T-type modular multilevel converter (DTMMC) is an alternative to the existing uninterrupted power supply (UPS) due to its advantage in flexible leg reusing, multiple power ports, and high operating efficiency. Here, in this article, a DTMMC-UPS, which has series configurations on both input/output ac sides, obtains high-voltage grid/load accessing interfaces is presented. In the described system, the fact that copies of T-type legs are employed makes semiconductor failure common to happen. Moreover, both the coupling between rectifier and inverter conversions and the confliction between intercell and inner-cell voltage balancing make fault-tolerant control a tough issue. In this article, the switch fault types are first clarified and diagnosed by the different impacts on normal operation. An improved voltage vector modulation is then deduced to facilitate the planning of proper primary switching patterns, to achieve rectifier side normal operation. The secondary alternated level-shifted pulsed-width modulation (LS-PWM) is also modified to achieve inverter side normal operation. The experiment results are supplied to verify the validity of the modulation-coordinated fault toleration strategy.

42 ENGINEERING↗

Capacitor Voltage Ripple Estimation and Optimal Sizing of Modular Multi-Level Converters for Variable-Speed Drives

This article deals with the sizing of submodule capacitors for modular multilevel converters (MMCs) used for variable speed drives for medium voltage and high voltage electric machines. Variable speed drives are required to run over a wide frequency range from zero to a few hundred Hz or even over 1 kHz. Under low frequency operation (<30 Hz), a large current ripple flowing through the MMC submodule capacitors will cause significant capacitor voltage fluctuation. This article proposes an optimal submodule capacitor selection method based on the common-mode voltage injection. The proposed sizing model includes two functions: 1) accurately estimating the capacitor voltage ripple based on the drive system parameters; and 2) identifying the minimum capacitance of the submodule capacitors based on the allowed maximum capacitor voltage fluctuations. Simulation and experimental results show that the error between the actual and estimated values of the voltage fluctuation is within 3% using the proposed model.

42 ENGINEERING↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Optimal Control of an Oscillating Surge Wave Energy Converter

During this project, we experimentally investigated the hydrodynamics and performance of a laboratory-scale oscillating surge wave energy converter (OSWEC).We looked at how flap buoyancy and driveline losses (primarily in the form of stiction) affected the dynamics and performance of the device. In addition, we assessed the influence of flap profile (rounded vs. square edges) on OSWEC hydrodynamics. Through this, we were able to develop a deeper understanding of OSWEC performance and provide guidance on strategies to counteract artifacts that may be present in laboratory models, but are absent in field-scale devices. To do this, we tested a laboratory-scale OSWEC in the Sea Wave Environmental Lab (SWEL) wave tank at the National Renewable Energy Laboratory (NREL). We ran several types of experiments to investigate the hydrodynamics and performance of the device. Overall, we achieved the overall goal of experimentally investigating the hydrodynamics and performance of this device. We discovered important and unexpected trends in performance, and collected time-resolved data to help us further investigate the underlying hydrodynamics responsible for these trends. In addition, we are currently using the time-resolved data from these experiments to build data-driven models of the dynamics, which can in turn be used to inform data-driven model predictive control of this device and address this objective in the future.

16 TIDAL AND WAVE POWER↗

Report on Coastal Structure Integrated Wave Energy Converters (CSI-WECs)

This report investigates a largely underexplored, and underexploited, application for wave energy: coastal structure integrated wave energy converters (CSI-WECs). These WEC types have significant potential to rapidly advance the wave energy industry while addressing the challenges of coastal community resiliency and marine energy integration and application, and the urgent need for increased coastal protection. To further support the value proposition investigation of this work, three wave energy developers agreed to conduct an energy production analysis of their technology for the four sites identified. Additionally, a geographic information system-based tool was developed that supports efficient and comprehensive site assessment for optimal and high-value deployments.

16 TIDAL AND WAVE POWER↗

Design of a readout circuit incorporating a 12-bit analog-to-digital converter for cooled infrared focal plane array

The infrared focal plane array (IRFPA) is gradually becoming more systematic. In order to enhance the signal processing capabilities, analog-to-digital converters (ADC) integrated into the readout integrated circuit (ROIC) is an important development trend. However, the cryogenic effects of MOSFET devices will affect the conversion accuracy of the ADC at 77 K. In this paper, the main parameters of MOSFET are extracted at 77 K in 0.18 μm CMOS process, and a cryogenic model is established. Based on this, a digital ROIC is designed, which integrates a 12-bit single-slope integral ADC in pixel unit. By applying continuous integral ramp generator and mixed-voltage comparator, a high-linearity and low-power consumption single-slope ADC is realized for the cooled readout circuit. The measured dynamic effective number of bits of the ADC at 77 K is 10.92 bits, the static no-missing code resolution reaches 11.99 bits, the maximum differential nonlinear |DNL| < 1LSB and maximum integral nonlinear |INL| < 1LSB. This paper realizes the design of a digital ROIC for IRFPA and improves the simulation accuracy at 77 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗