Experimental results and numerical modeling of a high-performance large-scale cryopump. I. Test particle Monte Carlo simulation

For the torus of the nuclear fusion project ITER (originally the International Thermonuclear Experimental Reactor, but also Latin: the way), eight high-performance large-scale customized cryopumps must be designed and manufactured to accommodate the very high pumping speeds and throughputs of the fusion exhaust gas needed to maintain the plasma under stable vacuum conditions and comply with other criteria which cannot be met by standard commercial vacuum pumps. Under an earlier research and development program, a model pump of reduced scale based on active cryosorption on charcoal-coated panels at 4.5 K was manufactured and tested systematically. The present article focuses on the simulation of the true three-dimensional complex geometry of the model pump by the newly developed ProVac3D Monte Carlo code. It is shown for gas throughputs of up to 1000 sccm ({approx}1.69 Pa m{sup 3}/s at T = 0 deg. C) in the free molecular regime that the numerical simulation results are in good agreement with the pumping speeds measured. Meanwhile, the capture coefficient associated with the virtual region around the cryogenic panels and shields which holds for higher throughputs is calculated using this generic approach. This means that the test particle Monte Carlo simulations in free molecular flow can be used not only for the optimization of the pumping system but also for the supply of the input parameters necessary for the future direct simulation Monte Carlo in the full flow regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D/3D image charge for modeling field emission

Analytic image charge approximations exist for planar and spherical metal surfaces but approximations for more complex geometries, such as the conical and wirelike structures characteristic of field emitters, are lacking. Such models are the basis for the evaluation of Schottky lowering factors in equations for current density. The development of a multidimensional image charge approximation, useful for a general thermal-field emission equation used in space charge studies, is given and based on an analytical model using a prolate spheroidal geometry. A description of how the model may be adapted to be used with a line charge model appropriate for carbon nanotube and carbon fiber field emitters is discussed. [http://dx.doi.org/10.1116/1.4968007]

47 OTHER INSTRUMENTATION↗

Nonevaporable getter coating chambers for extreme high vacuum

Techniques for NEG coating a large diameter chamber are presented along with vacuum measurements in the chamber using several pumping configurations, with base pressure as low as 1.56x10^-12 Torr (N2 equivalent) with only a NEG coating and small ion pump. We then describe modifications to the NEG coating process to coat complex geometry chambers for ultra-cold atom trap experiments. Surface analysis of NEG coated samples are used to measure composition and morphology of the thin films. Finally, pressure measurements are compared for two NEG coated polarized electron source chambers: the 130 kV polarized electron source at Jefferson Lab and the upgraded 350 kV polarized 2 electron source, both of which are approaching or within the extreme high vacuum (XHV) range, defined as P<7.5x10^-13 Torr.

47 OTHER INSTRUMENTATION↗

Small-scale production of bespoke accelerated aging plutonium alloy

Here, this study demonstrates the 100 g scale manufacture of a plutonium alloy that ages at an accelerated rate. The resulting alloy ages six times faster than typical weapons-grade plutonium due to the addition of 238 Pu. As a major innovation, the process involved using a partial direct oxide reduction technique. This method was achieved by developing a new, complex geometry stirrer using additive manufacturing to reduce the 238Pu oxide and efficiently incorporate it into weapons-grade plutonium metal. The material was then purified by molten salt extraction and electrorefining before being alloyed with gallium. The alloy was then cold-rolled and annealed in a homogenization heat treatment. The resulting disk was characterized by metallography and differential scanning calorimetry, and the impurity content was determined using analytical chemistry techniques. The results show that a homogeneous delta phase plutonium alloy was achieved with expected microstructure and minimal impurities. This study was also successful in changing the plutonium isotopic composition by incorporating additional 238 Pu to accelerate the effects of radiation damage. This enables researchers to study long-term aging phenomena in a reduced time frame, thus avoiding the need for large-scale material production and circumventing the limitations of using naturally aged, archived plutonium.

Aging theory↗

Compatibility of molten plutonium with wrought and additively manufactured metal crucibles

Understanding plutonium’s interaction with metals is crucial for optimizing pyrochemical operations, nuclear fuel containment, and various actinide processing techniques. Traditionally, tantalum crucibles are employed for plutonium processing due to their high durability, excellent temperature stability, and low solubility in plutonium. However, tantalum faces challenges such as plutonium wetting and diffusion, making surface coatings particularly important for crucibles in pyrochemical applications to enhance corrosion resistance against plutonium. Tantalum is also expensive and difficult to machine, prompting the need for advanced manufacturing techniques to address these challenges. Here, in this work, we investigate the interaction of Pu with tantalum and titanium crucibles fabricated using both traditional machining methods and laser powder bed fusion (LPBF) additive manufacturing (AM). LPBF-AM is an advanced technique that allows for the creation of complex geometries from traditionally difficult-to-machine metals by using a high-powered laser to build parts. Previous studies of conventional manufactured tantalum have utilized oxidation and carburization of the surface to mitigate plutonium wetting; however, no studies of surface modified LPBF-AM material have been undertaken. These studies are crucial, given the typical differences in the grain structure between conventional and LPBF-AM materials. All crucibles underwent differential scanning calorimetry to confirm the melting of plutonium. Subsequently, the crucibles were sectioned and mounted in epoxy for microstructural analysis using optical microscopy and scanning electron microscopy. This investigation, comparing the performance of wrought vs AM metal crucibles, provides a basis for future tooling applications in actinide processing techniques and can address the challenges associated with traditional machining, particularly in pyrochemical applications.

Actinides↗

Atomic layer deposition for aligned growth of and conformal deposition onto double and triple walled carbon nanotubes

We present our work on the growth and functionalization of carbon nanotubes (CNTs). A significant challenge in the growth of aligned single, double and triple walled nanotubes is in the deposition of a controlled thickness catalyst layer. Conventional techniques using line of sight deposition such as sputtering and evaporation produce uniform catalyst layers only when extreme care is taken in the placement of flat substrates. Growth of aligned low wall number carbon nanotubes on contoured, complex geometry, or large surface area substrates is simply not technically feasible through these techniques. Using iron atomic layer deposition (ALD) with ferrocene and oxygen precursors for catalyst deposition circumvents the line of sight problems and allows for uniform coverage across almost all substrates. Furthermore the ALD technique allows for extremely accurate and reproducible thickness depositions. Using these ALD catalyst layers reproducible aligned arrays consisting of primarily double and triple wall CNTS can be fabricated. Conformal coatings onto high aspect ratio surfaces are particularly challenging. The walls of single carbon nanotubes in a nanotube array are inaccessible by line of sight techniques. ALD circumvents this problem by relying on a gas-surface reaction to initiate growth. Generally, growth of ALD films on CNTs results in beading of the deposited materials around CNT defects. This is particularly true of high surface energy materials. The number of nucleation sites and the onset of growth of Pt by ALD can be tuned by use of Ar plasma, O 2 plasma and chemical functionalization.

30 DIRECT ENERGY CONVERSION↗

4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy

Purpose: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable. In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. Methods: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. Results: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged {beta}{sup +}-activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered dose. Conclusions: 4DibPET is a feasible and promising method to validate treatment delivery of scanned ion beams to moving targets. Further investigations will focus on more complex geometries and treatment planning studies with clinical data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Helical tomotherapy with dynamic running-start-stop delivery compared to conventional tomotherapy delivery

Purpose: Despite superior target dose uniformity, helical tomotherapy{sup ®} (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. Methods: Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain, head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. Results: The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. Conclusions: Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster treatment delivery and improved cranial-caudal target dose conformity. The target coverage achieved by RSS with a large jaw width is comparable to the fixed jaw HT delivery for common cancer sites, but may deteriorate for cases where complex geometry is present in the middle part of the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-258: Parallel Optimization of Beam Configurations for CyberKnife Treatments

Purpose: The CyberKnife delivers a large number of beams originating at different non-planar positions and with different orientation. We study how much the quality of treatment plans depends on the beams considered during plan optimization. Particularly, we evaluate a new approach to search for optimal treatment plans in parallel by running optimization steps concurrently. Methods: So far, no deterministic, complete and efficient method to select the optimal beam configuration for robotic SRS/SBRT is known. Considering a large candidate beam set increases the likelihood to achieve a good plan, but the optimization problem becomes large and impractical to solve. We have implemented an approach that parallelizes the search by solving multiple linear programming problems concurrently while iteratively resampling zero weighted beams. Each optimization problem contains the same set of constraints but different variables representing candidate beams. The search is synchronized by sharing the resulting basis variables among the parallel optimizations. We demonstrate the utility of the approach based on an actual spinal case with the objective to improve the coverage. Results: The objective function is falling and reaches a value of 5000 after 49, 31, 25 and 15 iterations for 1, 2, 4, and 8 parallel processes. This corresponds to approximately 97% coverage in 77%, 59%, and 36% of the mean number of iterations with one process for 2, 4, and 8 parallel processes, respectively. Overall, coverage increases from approximately 91.5% to approximately 98.5%. Conclusion: While on our current computer with uniform memory access the reduced number of iterations does not translate into a similar speedup, the approach illustrates how to effectively parallelize the search for the optimal beam configuration. The experimental results also indicate that for complex geometries the beam selection is critical for further plan optimization.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-546: Modeling and Validation of the a New Proton Therapy System Using a Monte-Carlo Environment Optimized for Protons

8 particle histories were run. Results: Range measurements of the Monte-Carlo simulations matched the measured data within 1mm. Distal fall-off of the simulated fields matched within <1mm. Lateral penumbra and field size measurements of the standard-sized square and half-beam blocked fields matched within 1mm at all three planes compared. A small difference was seen in the in-air profiles at doses <0%. The suspected cause of the difference was the aperture shape. The measured data utilized a divergent aperture. The Monte-Carlo calculation used a non-divergent aperture. Conclusion: The validation measurements indicate that we were able to accurately model the MEVION s250 Proton therapy system using Monte-Carlo Calculations. This may reduce the commissioning time for future users. Purpose: Monte-Carlo modeling is an important tool for understanding the behavior of therapeutic proton beams in a heterogeneous media such as the patient. To gain confidence that a Monte-Carlo model is accurate in complex geometries and media, it must first be compared with measurement in simple situations. This study documents the validation of our Monte-Carlo Model. Methods: A model of the MEVION s250 Proton therapy system was created in the TOPAS Monte-Carlo environment using machine geometry and field shaping system information provided by the vendor. For each of 24 options, validation of the TOPAS model was performed by comparing the dose scored by TOPAS to the dose measurements obtained during the commissioning of the treatment planning system. The measurements compared consisted of: pristine peak depth-dose profiles, in-air profiles for a standard-sized square field (20cm×20cm or 10cm×10cm depending on the maximum field size for each option) at isocenter and at 20cm upstream and downstream of isocenter, and in-air profiles with a half-beam blocked aperture at isocenter and at 20cm upstream and downstream of isocenter. For all Monte-Carlo simulations,.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-174: A Series of Computational Human Phantoms in DICOM-RT Format for Normal Tissue Dose Reconstruction in Epidemiological Studies

Purpose: Epidemiological studies of second cancer risk in radiotherapy patients often require individualized dose estimates of normal tissues. Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D radiological images or not even available. Generic patient CT images are often used in commercial radiotherapy treatment planning system (TPS) to reconstruct normal tissue doses. The objective of the current work was to develop a series of reference size computational human phantoms in DICOM-RT format for direct use in dose reconstruction in TPS. Methods: Contours of 93 organs and tissues were extracted from a series of pediatric and adult hybrid computational human phantoms (newborn, 1-, 5-, 10-, 15-year-old, and adult males and females) using Rhinoceros software. A MATLAB script was created to convert the contours into the DICOM-RT structure format. The simulated CT images with the resolution of 1×1×3 mm3 were also generated from the binary phantom format and coupled with the DICOM-structure files. Accurate volumes of the organs were drawn in the format using precise delineation of the contours in converted format. Due to complex geometry of organs, higher resolution (1×1×1 mm3) was found to be more efficient in the conversion of newborn and 1-year-old phantoms. Results: Contour sets were efficiently converted into DICOM-RT structures in relatively short time (about 30 minutes for each phantom). A good agreement was observed in the volumes between the original phantoms and the converted contours for large organs (NRMSD<1.0%) and small organs (NRMSD<7.7%). Conclusion: A comprehensive series of computational human phantoms in DICOM-RT format was created to support epidemiological studies of second cancer risks in radiotherapy patients. We confirmed the DICOM-RT phantoms were successfully imported into the TPS programs of major vendors.

60 APPLIED LIFE SCIENCES↗

Resolution recovery for Compton camera using origin ensemble algorithm

Purpose: Compton cameras (CCs) use electronic collimation to reconstruct the images of activity distribution. Although this approach can greatly improve imaging efficiency, due to complex geometry of the CC principle, image reconstruction with the standard iterative algorithms, such as ordered subset expectation maximization (OSEM), can be very time-consuming, even more so if resolution recovery (RR) is implemented. We have previously shown that the origin ensemble (OE) algorithm can be used for the reconstruction of the CC data. Here we propose a method of extending our OE algorithm to include RR. Methods: To validate the proposed algorithm we used Monte Carlo simulations of a CC composed of multiple layers of pixelated CZT detectors and designed for imaging small animals. A series of CC acquisitions of small hot spheres and the Derenzo phantom placed in air were simulated. Images obtained from (a) the exact data, (b) blurred data but reconstructed without resolution recovery, and (c) blurred and reconstructed with resolution recovery were compared. Furthermore, the reconstructed contrast-to-background ratios were investigated using the phantom with nine spheres placed in a hot background. Results: Our simulations demonstrate that the proposed method allows for the recovery of the resolution loss that is due to imperfect accuracy of event detection. Additionally, tests of camera sensitivity corresponding to different detector configurations demonstrate that the proposed CC design has sensitivity comparable to PET. When the same number of events were considered, the computation time per iteration increased only by a factor of 2 when OE reconstruction with the resolution recovery correction was performed relative to the original OE algorithm. We estimate that the addition of resolution recovery to the OSEM would increase reconstruction times by 2–3 orders of magnitude per iteration. Conclusions: The results of our tests demonstrate the improvement of image resolution provided by the OE reconstructions with resolution recovery. The quality of images and their contrast are similar to those obtained from the OE reconstructions from scans simulated with perfect energy and spatial resolutions.

60 APPLIED LIFE SCIENCES↗

A three-dimensional photonic topological insulator using a two-dimensional ring resonator lattice with a synthetic frequency dimension

In the development of topological photonics, achieving three-dimensional topological insulators is of notable interest since it enables the exploration of new topological physics with photons and promises novel photonic devices that are robust against disorders in three dimensions. Previous theoretical proposals toward three-dimensional topological insulators use complex geometries that are challenging to implement. On the basis of the concept of synthetic dimension, we show that a two-dimensional array of ring resonators, which was previously demonstrated to exhibit a two-dimensional topological insulator phase, automatically becomes a three-dimensional topological insulator when the frequency dimension is taken into account. Moreover, by modulating a few of the resonators, a screw dislocation along the frequency axis can be created, which provides robust one-way transport of photons along the frequency axis. Demonstrating the physics of screw dislocation in a topological system has been a substantial challenge in solid-state systems. Our work indicates that the physics of three-dimensional topological insulators can be explored in standard integrated photonic platforms, leading to opportunities for novel devices that control the frequency of light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Casting inorganic structures with DNA molds

Here we report a general strategy for designing and synthesizing inorganic nanostructures with arbitrarily prescribed three-dimensional shapes. Computationally designed DNA strands self-assemble into a stiff “nano-mold” that contains a user-specified three-dimensional cavity and encloses a nucleating gold “seed”. Under mild conditions, this seed grows into a larger cast structure that fills and thus replicates the cavity. We synthesized a variety of nanoparticles with three nanometer resolution: three distinct silver cuboids with three independently tunable dimensions, silver and gold nanoparticles with diverse cross sections, and composite structures with homo-/heterogeneous components. The designer equilateral silver triangular and spherical nanoparticles exhibited plasmonic properties consistent with electromagnetism-based simulations. Our framework is generalizable to more complex geometries and diverse inorganic materials, offering a range of applications in biosensing, photonics, and nanoelectronics.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient Operator-Coarsening Multigrid Schemes for Local Discontinuous Galerkin Methods

An efficient hp-multigrid scheme is presented for local discontinuous Galerkin (LDG) discretizations of elliptic problems, formulated around the idea of separately coarsening the underlying discrete gradient and divergence operators. We show that traditional multigrid coarsening of the primal formulation leads to poor and suboptimal multigrid performance, whereas coarsening of the flux formulation leads to essentially optimal convergence and is equivalent to a purely geometric multigrid method. The resulting operator-coarsening schemes do not require the entire mesh hierarchy to be explicitly built, thereby obviating the need to compute quadrature rules, lifting operators, and other mesh-related quantities on coarse meshes. We show that good multigrid convergence rates are achieved in a variety of numerical tests on two-dimensional and three-dimensional uniform and adaptive Cartesian grids, as well as for curved domains using implicitly defined meshes and for multiphase elliptic interface problems with complex geometry. Extensions, e.g., to non-LDG discretizations and fully unstructured meshes, are briefly discussed.

97 MATHEMATICS AND COMPUTING↗

A Parallel Cut-Cell Algorithm for the Free-Boundary Grad--Shafranov Problem

A parallel cut-cell algorithm is described to solve the free-boundary problem of the Grad--Shafranov equation. The algorithm reformulates the free-boundary problem in an irregular bounded domain and its important aspects include a searching algorithm for the magnetic axis and separatrix, a surface integral along the irregular boundary to determine the boundary values, an approach to optimize the coil current based on a targeting plasma shape, Picard iterations with Aitken's acceleration for the resulting nonlinear problem, and a Cartesian grid embedded boundary method to handle the complex geometry. Here the algorithm is implemented in parallel using a standard domain-decomposition approach and a good parallel scaling is observed. Numerical results verify the accuracy and efficiency of the free-boundary Grad--Shafranov solver.

97 MATHEMATICS AND COMPUTING↗

Branson: A Mini-App for Studying Parallel IMC, Version 1.0

This code solves the gray thermal radiative transfer (TRT) equations in parallel using simple opacities and Cartesian meshes. Although Branson solves the TRT equations it is not designed to model radiation transport: Branson contains simple physics and does not have a multigroup treatment, nor can it use physical material data. The opacities have are simple polynomials in temperature there is a limited ability to specify complex geometries and sources. Branson was designed only to capture the computational demands of production IMC codes, especially in large parallel runs. It was also intended to foster collaboration with vendors, universities and other DOE partners. Branson is similar in character to the neutron transport proxy-app Quicksilver from LLNL, which was recently open-sourced.

Long, Alex↗

KIVA-hpFE version 1.0.1

KIVA-hpFE is a computer software for solving the physics of multi-species turbulent reactive flow in complex geometries having immersed moving parts. The code is written in Fortran 90/95 and can be used on any computer platform with any popular complier. The code is in 2 versions, a serial version and a parallel version utilizing MPICH2 type Message Passing Interface (MPI or Intel MPI) for solving distributed domains.

Waters, Jiajia↗