Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Compact Li-doped Gd{sub 2}Ti{sub 2}O{sub 7} prepared with LiO{sub 0.5} self-flux

Graphical abstract: Left figure is the unit cell a-axis of the GLT-2L (■), GLT (●) and GT (▴) as a function of x. Both of the GLT-2L and GLT have the same results so that they have the same chemical formula, (Gd{sub 2−x}Li{sub x})Ti{sub 2}O{sub 7−x}, in which GT has a formula of Gd{sub 2−x}Ti{sub 2}O{sub 7−x}. Relative densities are shown in the right figure. GLT-2L (■) has higher values than GLT (●). 2x moles of LiO{sub 0.5} were added as a self-flux to prepare GLT-2L at 1250 °C, which was about 300 °C lowered than required without the co-existence of the flux and Li ion substitution. - Highlights: • A new series of compounds with a formula as (Gd{sub 2−x}Li{sub x})Ti{sub 2}O{sub 7−x} was synthesized. • Each GLT-2L sample contains (Gd{sub 2−x}Li{sub x})Ti{sub 2}O{sub 7−x} and 2x moles of LiO{sub 0.5} self-flux. • 1250 °C was used to prepare the GLT-2L samples; 300 °C lower than required. • Electrical conductivity of the GLT-2L is not affected by the presence of the flux. • Average valence of the Ti ions is slightly less than 4. - Abstract: A series of (Gd{sub 2−x}Li{sub x})Ti{sub 2}O{sub 7−x} with x = 0.040–0.110 was first reported. Parent compound with 2x moles of LiO{sub 0.5} self-flux was prepared at 1250 °C and abbreviated as GLT-2L. Relative density of all the samples is higher than 92%. By the addition of flux and Li ions substitution, preparation temperature is lowered for more than 300 °C. Comparing the unit cell a-axis, GLT with a formula as (Gd{sub 2−x}Li{sub x})Ti{sub 2}O{sub 7−x} without flux addition has exactly the same as the GLT-2L with the same x. By the addition of flux, materials become more compact and grains grow bigger for the GLT-2L than the corresponding GLT samples. Electrical conductivity of a GLT-2L with x = 0.110 at 700 °C is 3 times larger than the measurements done by other research groups in the Gd{sub 2}Ti{sub 2}O{sub 7}. In order to demonstrate the successful substitution of the Li ion into the Gd site, a series of GT samples was prepared with a formula of Gd{sub 2−x}Ti{sub 2}O{sub 7−1.5x}. With the same amount of x, every GLT samples have a longer unit cell a-axis than that of the GT. The difference is caused by the substitution of the Li ion into the Gd site. Valence of the Ti atoms of the GLT-2L samples is slightly less than 4 studied by the XANES spectroscopy.

36 MATERIALS SCIENCE↗

A compact design for an electric driven hydraulic gear machine capable of multiple quadrant operation

This paper presents an innovative design of an integrated electro-hydraulic (EH) flow generation unit able to operate in multiple quadrants. The proposed unit is composed of a hydraulic machine which can operate in either pumping or motoring mode, and an electric machine, which can operate as electric motor or generator. The adopted morphological integration of the two unit fulfills the goals of maximizing compactness, power to weight ratio, energy efficiency and quietness. Furthermore, the design results from a numerical optimization procedure that includes detailed simulation of both the electric machine and the hydraulic machine, using simulation tools previously developed by the authors, but combined for the first time in this work. After describing the optimization procedure, the paper focuses on the design integration aspects of the novel unit. A 9 kW prototype of the integrated unit was also fabricated and tested to verify its performance. Tests results show a measured overall energy efficiency up to 69%, demonstrating the potentials of the proposed concept, despite some limitations present in the first prototypes which could be addressed in future design refinements.

42 ENGINEERING↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗

SimTrack: A compact c++ code for particle orbit and spin tracking in accelerators

SimTrack is a compact c++ code of 6-d symplectic element-by-element particle tracking in accelerators originally designed for head-on beam–beam compensation simulation studies in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. It provides a 6-d symplectic orbit tracking with the 4th order symplectic integration for magnet elements and the 6-d symplectic synchro-beam map for beam–beam interaction. Since its inception in 2009, SimTrack has been intensively used for dynamic aperture calculations with beam–beam interaction for RHIC. Recently, proton spin tracking and electron energy loss due to synchrotron radiation were added. In this article, I will present the code architecture, physics models, and some selected examples of its applications to RHIC and a future electron-ion collider design eRHIC.

43 PARTICLE ACCELERATORS↗

A LYSO crystal array readout by silicon photomultipliers as compact detector for space applications

Precise measurements of GeV range gamma rays help narrow down among var- ious gamma emission models and increase sensitivity for dark matter searches. Construction of precise as well as compact instruments requires detectors with high efficiency, high stopping power, excellent energy resolution, and excellent angular resolution. Fast and bright crystal scintillators coupled with small foot- print photo-detectors are suitable candidates. We prototyped a detector array consisting of four LYSO crystals where each crystal is read out by a 2x2 SensL ArrayJ60035 silicon photomultipliers. The LYSO crystals were chosen because of their good light yield, fast decay time, demonstrated radiation hardness, and small radiation length. Here, we used the silicon photomultiplier arrays as photo- detectors because of their small size, simple readout, low voltage operation, and immunity to magnetic elds. We also studied the detector performance in the energy range of interest by exposing it to 2-16 GeV particles produced at the Test Beam Facility of Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Compact, directional neutron detectors capable of high-resolution nuclear recoil imaging

We report on the design, production, and performance of compact 40-cm3 Time Projection Chambers (TPCs) that detect fast neutrons by measuring the three-dimensional (3D) ionization distribution of nuclear recoils in 4 He:CO 2 gas at atmospheric pressure. We use these detectors to characterize the fast-neutron flux inside the Belle II detector at the SuperKEKB electron–positron collider in Tsukuba, Japan, where the primary design constraint is a small form factor. We find that the TPCs meet or exceed all design specifications, and are capable of measuring the 3D surface shape and charge density profile of ionization clouds from nuclear recoils and charged tracks in exquisite detail. Scaled-up detectors based on the detection principle demonstrated here may be suitable for directional dark matter searches, measurements of coherent neutrino–nucleus scattering, and other experiments requiring precise detection of neutrons or nuclear recoils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Code validation of SAM using natural-circulation experimental data from the compact integral effects test (CIET) facility

The primary objective of this study is to validate the system analysis code, SAM, using experimental data from the Compact Integral Effects Test (CIET) experimental loop. SAM is a modern system analysis code being developed at Argonne National Laboratory for safety analysis of designs for advanced non-light water reactors (non-LWRs), such as sodium-cooled fast reactors, high-temperature gas-cooled reactors, and fluoride salt-cooled high-temperature reactors (FHRs). To support SAM code development for the wide range of non-LWR applications, it is of paramount importance to validate the code against experiments highly relevant to these reactor concepts. Additionally, the CIET facility, which was designed to reproduce the thermal-hydraulics response of FHRs under both forced- and natural-circulation conditions, has been identified and selected as one of the benchmark test facilities for SAM code validation. In this study, two sets of available CIET tests were selected for SAM code validation purposes, namely, power step change transient tests and steady-state natural-circulation tests. For all selected tests, SAM-predicted results show very good agreement with experimental data. The successful validation of SAM against these selected CIET experiments demonstrates that the computer code is well suited for thermal-hydraulics analysis of FHR designs.

42 ENGINEERING↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

Intense combined source of neutrons and photons for interrogation based on compact deuteron RF accelerator

Interrogation of special nuclear materials can benefit from mobile sources providing significant fluxes of neutrons (10 8 /s at 2.5 MeV, 10 10 /s at 14.1 MeV) and of photons (>10 12 /s at 1-3 MeV). We propose a source that satisfies these requirements simultaneously plus also provides, via the reaction 11 B(d,n) 12 C(γ 15.1 ), a significant flux of 15-MeV photons, which are highly penetrating and optimal for inducing photo-fission in actinides. The source is based on a compact (< 5 m) deuteron RF accelerator that delivers an average current of a few mA of deuterons at 3-4 MeV to a boron target. The accelerator consists of a short RFQ followed by efficient inter-digital H-mode structures with permanent-magnet-quadrupole beam focusing [Kurennoy et al. (2012)], which suit perfectly for deuteron acceleration at low energies. Our estimates, based on recent measurements, indicate that the required fluxes of both neutrons and photons can be achieved at ~1 mA of 4-MeV deuterons. The goal of the proposed study is to confirm feasibility of the approach and develop requirements for future full system implementation.

43 PARTICLE ACCELERATORS↗

Some new results on charged compact boson stars

In this work we present some new results obtained in a study of the phase diagram of charged compact boson stars in a theory involving a complex scalar field with a conical potential coupled to a U(1) gauge field and gravity. We here obtain new bifurcation points in this model. We present a detailed discussion of the various regions of the phase diagram with respect to the bifurcation points. The theory is seen to contain rich physics in a particular domain of the phase diagram.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for compact dark matter objects in the solar system with LIGO data

Dark matter could be composed of compact dark objects (CDOs). A close binary of CDOs orbiting in the interior of solar system bodies can be a loud source of gravitational waves (GWs) for the LIGO and VIRGO detectors. We perform the first search ever for this type of signal and rule out close binaries orbiting near the center of the Sun with GW frequencies (twice the orbital frequency) between 50 and 550 Hz and CDO masses above $\approx 10^{-9} M_\odot$. This mass limit is eight orders of magnitude lower than the mass probed in a LIGO search at extra galactic distances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser

A mid-infrared ethane (C 2 H 6 ) sensor based on a wavelength modulation spectroscopy (WMS) technique was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) interband cascade laser (ICL) emitting at 3.34 μm and a dense multi-pass gas cell (MPGC, 17 × 6.5 × 5.5 cm 3 ) with a 54.6 m optical path length. A compact optical sensor system with a physical size of 35.5 × 18 × 12.5 cm 3 was designed and constructed. An ICL was employed for targeting a strong C 2 H 6 line at 2996.88 cm -1 at <100 Torr gas pressure in the fundamental absorption band of C 2 H 6 . The sensor performance, including the minimum detection limit (MDL) and the stability were improved by reducing the effect of laser power drift by means of the 2f/1f-WMS technique. A MDL of ~1.2 parts per billion (ppbv) for 2f-WMS and ~1.0 ppbv for 2f/1f-WMS were achieved, respectively, with a measurement time of 4 s. The MDL was further improved from 299 pptv (@108 s for 2f-WMS) to 239 pptv (@208 s for 2f/1f-WMS), based on an Allan deviation analysis.The rise time (@0 → 100 ppbv) and fall time (@100 → 0 ppbv) were determined to be ~64 s and ~48 s,respectively, at a gas pressure of <100 Torr for the C 2 H 6 sensor operation.

03 NATURAL GAS↗

Design of compact ultrafast microscopes for single- and multi-shot imaging with MeV electrons

Ultrafast high-energy electron microscopy, taking advantage of strong interaction of electrons with matter while minimizing space charge problems, can be used to address a wide range of grand challenges in basics energy sciences. However, MeV-electron lenses are inherently bulky and expensive, preventing them from acceptance in a broad scientific community. In this article, we report our novel design of a compact, low-cost imaging-lens system for MeV-electrons based on quadrupole multiplets, including triplet, quadruplet and quintuplet, both symmetric and asymmetric. We compare optical performance of quadrupole-based condenser, objective and projector lenses with that of the traditional round-lenses and discuss the strategy for their practical use in constructing MeV-electron microscopes for high spatial and temporal resolution single- and multi-shot imaging. Combining the compound electron-optical system with a photocathode radiofrequency (RF) gun, such a MeV electron microscope can be fit into a smallsized laboratory for ultrafast observations and measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of compact tokamak fusion reactor use cases to inform future transport studies

The OMFIT STEP (Meneghini et al. , Nucl. Fusion , vol. 10, 2020, p. 1088) workflow has been used to develop inductive and steady-state H-mode core plasma scenario use cases for a $B_0 = 8 \, {\rm T}$ , $R_0 = 4 \, {\rm m}$ machine to help guide and inform future higher-fidelity studies of core transport and confinement in compact tokamak reactors. Both use cases are designed to produce 200 MW or more of net electric power in an up-down symmetric plasma with minor radius $a = 1.4 \, {\rm m}$ , elongation $\kappa = 2.0$ , triangularity $\delta = 0.5$ and effective charge $Z_{{\rm eff}} \simeq 2$ . Additional considerations based on the need for compatibility of the core with reactor-relevant power exhaust solutions and external actuators were used to guide and constrain the use case development. An extensive characterization of core transport in both scenarios is presented, the most important feature of which is the extreme sensitivity of the results to the quantitative stiffness level of the transport model used as well as the predicted critical gradients. This sensitivity is shown to arise from different levels of transport stiffness exhibited by the models, combined with the gyroBohm-normalized fluxes of the predictions being an order of magnitude larger than other H-mode plasmas. Additionally, it is shown that although heating in both plasmas is predominantly to the electrons and collisionality is low, the plasmas remain sufficiently well coupled for the ions to carry a significant fraction of the thermal transport. As neoclassical transport is negligible in these conditions, this situation inherently requires long-wavelength ion gyroradius-scale turbulence to be the dominant transport mechanism in both plasmas. These results are combined with other basic considerations to propose a simple heuristic model of transport in reactor-relevant plasmas, along with simple metrics to quantify coupling and core transport properties across burning and non-burning plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving High Resolution Ion Mobility Separations Using Traveling Waves in Compact Multiturn Structures for Lossless Ion Manipulations

We report on ion mobility separations (IMS) achievable using traveling waves in a Structures for Lossless Ion Manipulations (TW-SLIM) module having a 44-cm path length and sixteen 90º turns. The performance of the TW-SLIM module was evaluated for ion transmission, and ion mobility separations with different RF, TW parameters and SLIM surface gaps in conjunction with mass spectrometry. In this work TWs were created by the transient and dynamic application of DC potentials. The TW-SLIM module demonstrated highly robust performance and the ion mobility resolution achieved even with sixteen close spaced turns was comparable to a similar straight path TW-SLIM module. We found an ion mobility peak capacity of ~ 31 and peak generation rate of 780 s-1 for TW speeds of <210 m/s using the current multi-turn TW-SLIM module. The separations achieved for isomers of peptides and tetrasaccharides were found to be comparable to those from a ~ 0.9-m drift tube-based IMS-MS platform operated at the same pressure (4 torr). The combined attributes of flexible design, low voltage requirements and lossless ion transmission through multiple turns for the present TW-SLIM module provides a basis for SLIM devices capable of achieving much greater ion mobility resolutions via greatly extended ion path lengths and compact serpentine designs that do not significantly impact the instrumentation profile, a direction described in a companion manuscript.

Environmental Molecular Sciences Laboratory↗