Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Building Loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly influenced by climate. While direct-DC for residential applications will most likely arise as a spin-off of developments in the commercial sector—because of lower barriers to market entry and larger energy benefits resulting from the higher coincidence between load and insolation—this paper demonstrates that there are substantial benefits in the residential sector as well. Among residential applications, space cooling derives the largest energy savings from being delivered by a direct-DC system. It is the largest load for the average residence on a national basis and is particularly so in high-load regions. It is also the load with highest solar coincidence.

14 SOLAR ENERGY↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cost-Benefit Analysis of High-Strength Materials for Safety-Related Nuclear Reinforced Concrete Shear Walls

A numerical parametric investigation was conducted to determine the economic benefits of utilizing high-strength concrete and high-strength steel reinforcing bar (rebar) in reinforced concrete (RC) shear walls for nuclear power plant structures. Thick RC shear walls with low height-to-length aspect ratios (i.e., aspect ratios, h{sub w}/l{sub w}≤2.0, where h{sub w} is the wall height and l{sub w} is the wall length) are the most common lateral load resisting members in non-containment, safety-related nuclear structures. Typically, the walls are reinforced with multiple layers of overlapping, large-diameter vertical and horizontal rebar on each face. These heavily-reinforced walls provide large lateral stiffness and strength to prevent significant deformations and/or cracking that could compromise the integrity of the nuclear facility. However, this design adversely affects constructability as the rebar cages become highly congested. The time, labor, and materials required for this construction lead to high overall project costs. There has been a recent research thrust in the U.S. to allow high-strength rebar in non-nuclear building structures. While some of this research (e.g., steel properties, bond, anchorage) is applicable to RC structures in general, there are important differences specific to nuclear structures, such as much thicker walls (often controlled by radiation and thermal cycling), larger reinforcement ratios, and increased susceptibility to shear-controlled behavior (due to low aspect ratios). An important limiting factor for non-nuclear structures in seismic regions is the reduced deformation capacity of high-strength rebar as compared with normal-strength rebar used in current practice. Differences in seismic design philosophy lessen this limitation for nuclear structures (i.e., nuclear structures are designed more conservatively and allowed to undergo significantly smaller nonlinear displacements), making high-strength rebar a promising alternative to reinforcement currently permissible in the ACI 349-13 code requirements, which govern the design of nuclear safety-related concrete structures. To improve constructability and economy, this study investigates the benefits of using high-strength rebar [i.e., ASTM A615 Grade 550 (U.S. Grade 80); ASTM A1035 Grades 690 and 830 (U.S. Grades 100 and 120), where the grade indicates the specified yield strength of the steel in MPa (ksi)] together with high-strength concrete [compression strengths up to 138 MPa (20.0 ksi)] in RC nuclear shear walls. These strength ranges represent steel and concrete materials that are commercially available in the U.S. High-strength rebar can significantly reduce the required steel areas, thereby reducing material/fabrication costs, reducing rebar congestion (fewer/smaller bars and bar layers), and facilitating concrete consolidation and placement. Previous research on the use of high-strength rebar and/or high-strength concrete in nuclear RC structures does not exist in North America. A recent study assessed the potential of high-strength steel to reduce the rebar volume in non-nuclear building construction. In Japan, researchers investigated the use of high-strength materials in safety-related nuclear RC structures, but did not explore the economic benefits of these materials. To address this knowledge gap, the current paper describes a numerical parametric investigation on the potential cost savings of nuclear shear walls with high-strength rebar and/or concrete through comparisons against state-of-practice walls with normal-strength materials. Overall, the results demonstrate that significant economic benefits can be realized by implementing high-strength rebar and concrete in these structures. (authors)

36 MATERIALS SCIENCE↗

Technology solutions for wind integration in ERCOT

Texas has for more than a decade led all other states in the U.S. with the most wind generation capacity on the U.S. electric grid. The State recognized the value that wind energy could provide, and committed early on to build out the transmission system necessary to move power from the windy regions in West Texas to the major population centers across the state. It also signaled support for renewables on the grid by adopting an aggressive renewable portfolio standard (RPS). The joining of these conditions with favorable Federal tax credits has driven the rapid growth in Texas wind capacity since its small beginning in 2000. In addition to the major transmission grid upgrades, there have been a number of technology and policy improvements that have kept the grid reliable while adding more and more intermittent wind generation. Technology advancements such as better wind forecasting and deployment of a nodal market system have improved the grid efficiency of wind. Successful large scale wind integration into the electric grid, however, continues to pose challenges. The continuing rapid growth in wind energy calls for a number of technology additions that will be needed to reliably accommodate an expected 65% increase in future wind resources. The Center for the Commercialization of Electric Technologies (CCET) recognized this technology challenge in 2009 when it submitted an application for funding of a regional demonstration project under the Recovery Act program administered by the U.S. Department of Energy1. Under that program the administration announced the largest energy grid modernization investment in U.S. history, making available some $3.4 billion in grants to fund development of a broad range of technologies for a more efficient and reliable electric system, including the growth of renewable energy sources like wind and solar. At that time, Texas was (and still is) the nation’s leader in the integration of wind into the grid, and was investing heavily in the infrastructure needed to increase the viability of this important resource. To help Texas and the rest of the nation address the challenges associated with the integration of large amounts of renewables, CCET seized on the federal opportunity to undertake a multi-faceted project aimed at demonstrating the viability of new “smart grid” technologies to facilitate larger amounts of wind energy through better system monitoring capabilities, enhanced operator visualization, and improved load management. In early 2010, CCET was awarded a $27 million grant, half funded by the Department of Energy and half-funded by project participants. With this funding, CCET undertook the project named Discovery Across Texas which has demonstrated how existing and new technologies can better integrate wind power into the state’s grid. The following pages summarize the results of seven technology demonstrations that will help Texas and the nation meet this wind integration challenge.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Home Network Technologies and Automating Demand Response

Over the past several years, interest in large-scale control of peak energy demand and total consumption has increased. While motivated by a number of factors, this interest has primarily been spurred on the demand side by the increasing cost of energy and, on the supply side by the limited ability of utilities to build sufficient electricity generation capacity to meet unrestrained future demand. To address peak electricity use Demand Response (DR) systems are being proposed to motivate reductions in electricity use through the use of price incentives. DR systems are also be design to shift or curtail energy demand at critical times when the generation, transmission, and distribution systems (i.e. the 'grid') are threatened with instabilities. To be effectively deployed on a large-scale, these proposed DR systems need to be automated. Automation will require robust and efficient data communications infrastructures across geographically dispersed markets. The present availability of widespread Internet connectivity and inexpensive, reliable computing hardware combined with the growing confidence in the capabilities of distributed, application-level communications protocols suggests that now is the time for designing and deploying practical systems. Centralized computer systems that are capable of providing continuous signals to automate customers reduction of power demand, are known as Demand Response Automation Servers (DRAS). The deployment of prototype DRAS systems has already begun - with most initial deployments targeting large commercial and industrial (C & I) customers. An examination of the current overall energy consumption by economic sector shows that the C & I market is responsible for roughly half of all energy consumption in the US. On a per customer basis, large C & I customers clearly have the most to offer - and to gain - by participating in DR programs to reduce peak demand. And, by concentrating on a small number of relatively sophisticated energy consumers, it has been possible to improve the DR 'state of the art' with a manageable commitment of technical resources on both the utility and consumer side. Although numerous C & I DR applications of a DRAS infrastructure are still in either prototype or early production phases, these early attempts at automating DR have been notably successful for both utilities and C & I customers. Several factors have strongly contributed to this success and will be discussed below. These successes have motivated utilities and regulators to look closely at how DR programs can be expanded to encompass the remaining (roughly) half of the state's energy load - the light commercial and, in numerical terms, the more important residential customer market. This survey examines technical issues facing the implementation of automated DR in the residential environment. In particular, we will look at the potential role of home automation networks in implementing wide-scale DR systems that communicate directly to individual residences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wave Energy Research, Testing and Demonstration Center

The purpose of this project was to build upon the research, development and testing experience of the Northwest National Marine Renewable Energy Center (NNMREC) to establish a non-grid connected open-ocean testing facility for wave energy converters (WECs) off the coast of Newport, Oregon. The test facility would serve as the first facility of its kind in the continental US with a fully energetic wave resource where WEC technologies could be proven for west coast US markets. The test facility would provide the opportunity for self-contained WEC testing or WEC testing connected via an umbilical cable to a mobile ocean test berth (MOTB). The MOTB would act as a “grid surrogate” measuring energy produced by the WEC and the environmental conditions under which the energy was produced. In order to realize this vision, the ocean site would need to be identified through outreach to community stakeholders, and then regulatory and permitting processes would be undertaken. Part of those processes would require environmental baseline studies and site analysis, including benthic, acoustic and wave resource characterization. The MOTB and its myriad systems would need to be designed and constructed.The first WEC test at the facility with the MOTB was completed within this project with the WET-NZ device in summer 2012. In summer 2013, the MOTB was deployed with load cells on its mooring lines to characterize forces on mooring systems in a variety of sea states. Throughout both testing seasons, studies were done to analyze environmental effects during testing operations. Test protocols and best management practices for open ocean operations were developed. As a result of this project, the non-grid connected fully energetic WEC test facility is operational, and the MOTB system developed provides a portable concept for WEC testing. The permitting process used provides a model for other wave energy projects, especially those in the Pacific Northwest that have similar environmental considerations. While the non-grid connected testing facility provides an option for WEC developers to prove their technology in a fully-energetic wave environment, the absence of grid connection is somewhat of a limitation. To prove that their technology is commercially viable, developers seek a multi-year grid connected testing option. To address this need, NNMREC is developing a companion grid connected test facility in Newport, Oregon, where small arrays of WECs can be tested as well.

16 TIDAL AND WAVE POWER↗

Digital Twin Model for Advanced Manufacture of a Rotating Detonation Engine Injector

A digital twin material model (DTMM) of an additive manufacturing (AM) process was created to advance the state of the art in rotating detonation engine (RDE) injector design. Current RDE injectors are designed with large pressure drops, enabling a stable and repeatable combustion process. However, this comes at the cost of system efficiency. For the technology to transition to commercial fossil-based power generation, it is important to develop injectors with reduced flow losses. Low-loss injectors are difficult to design and manufacture with conventional manufacturing techniques. AM enables new design options, but the AM manufacturing process must be thoroughly understood to result in a robust design. A DTMM provides the necessary insight by defining the cause-effect relationships between process parameters, microstructure features, and properties. Therefore, a DTMM to support the design and manufacturing process was developed and applied to the design of a new additively manufactured low-loss injector. The injector combustion behavior was characterized through hot-fire tests, and mechanical performance was compared to the DTMM predictions. The two project goals were the successful development of the DTMM and the demonstration of an improved RDE injector design. The RDE injector design and DTMM developments occurred on parallel but dependent paths. The injector was designed to reduce pressure drop by increasing the cross-sectional flow area ratio between the injector air passages and the combustor annulus. This resulted in less structural material, raising the concern that thin members would be susceptible to high-cycle fatigue (HCF) under the periodic loading inherent to an RDE. It was most important for the DTMM to predict behavior in these features; therefore, the injector design concept guided the material thicknesses used in fatigue tests. The DTMM development started by manufacturing a series of coupons over the range of possible AM process variations. A design-of-experiment approach was used to select which process variable combinations gave the most efficient coverage relevant to the injector design space. The microstructure in each of these coupons was characterized, and then computational methods were used to create a numerical model of the correlation between process variables and microstructure. Next, a set of HCF samples were tested to calibrate existing models that map microstructure to HCF performance. Together, these two links formed the DTMM that calculates HCF behavior from AM process variables. Two injector prototypes were additively manufactured. The first injector design strategy aggressively pursued low-loss performance by substantially increasing the oxidizer flow area. The combination of manufacturing lead times and the fatigue testing schedule meant that the DTMM was not available when building this first prototype. Therefore, its process parameters were chosen based on a manual review of the available coupon data. This prototype was built successfully and evaluated in 58 combustion tests. Sustained detonation was achieved with remarkably reduced pressure loss, and some tests even displayed pressure loss characteristics similar to conventional gas turbine combustors. This achieved the project goal of improving RDE injector design. The second injector was manufactured according to the optimized parameters predicted by the DTMM. The flow area modifications of this injector were less aggressive than the first injector since demonstrating low pressure loss was not an objective of the second hot-fire test series. Rather, the test objective was to cause high cycle fatigue failure in the part due to periodic loading from the rotating detonation wave. The observed number of cycles to failure was to be compared to the number predicted by the DTMM and thereby assess the utility of the DTMM in component design. However, the required level of vibration was not obtained during combustion. Therefore, high cycle fatigue was not experienced in the hot-fire tests of the second injector. Fatigue data was obtained by further testing the second injector in a conventional HCF test apparatus. The injector demonstrated HCF strength above the DTMM prediction. In fact, it did not fail and testing was only discontinued due to reaching the end of the period of performance. This points to some success in the project’s primary goal of successfully developing and applying the DTMM to a component design. Implementing the DTMM recommendations for optimal processing parameters led to a part with acceptable properties. The DTMM was also shown to be an efficient correlator of data and to provide insight into the relationship between process settings, microstructure, and property performance. However, the failure of the DTMM prediction to match the experimental result of the injector fatigue test also points to the need to include significantly more data in the model development. In this project, coupons made with identical processing parameters exhibited drastically different properties from each other and from the injector part, which clearly influences the accuracy of a model that predicts performance based on parameters. Uncertainties in the build process must be quantified to develop more robust models. A denser and broader matrix of coupon process and geometry variations, several repeated builds of every point, more in-situ build process measurements, and direct observation of tensile and HCF sample microstructure (as opposed to separate microstructure specimens) are recommendations to improve future AM modeling efforts.

20 FOSSIL-FUELED POWER PLANTS↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Development of Fusion Magnet Simulation Capabilities for Performance and Safety Evaluation Using the MOOSE Framework

Fusion energy holds the promise of being a transformative technology as a carbon-neutral, sustainable source of energy. Whole device modeling and the development of fusion digital twins will be increasingly important for emerging fusion device concepts at both national laboratories and within the commercial fusion industry. However, meeting the challenge of whole device modeling of fusion energy devices requires robust, multiphysics, multiscale modeling and simulation technologies capable of running on large-scale supercomputers. Detailed analysis of individual systems at-scale is also required to ensure safe and efficient operation as well as provide the safety basis for future device designs and licensing activities. In a tokamak, toroidal and poloidal magnets confine and shape the fusion plasma to promote the fusion reaction. High plasma temperatures and high magnetic field requirements in modern design concepts (leading to high amounts of energy stored within each magnet) impose electrical, thermal, and mechanical loads on the magnet components, which in turn impacts the safety considerations of the magnet and their supporting systems. Idaho National Laboratory (INL) has a history of working in this space, including development and benchmarking of the Magnetic System Circuitry Analysis Program (MSCAP) and Magnet Arcing (MAGARC) codes to study magnet quench events; notably, MAGARC was used to study quenching during the ITER Engineering Design Activity. However, these legacy codes and capabilities are not parallel and scalable, and new tools are required for future advances in this area, which leads to the INL-developed Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Developed originally for fission reactor systems under United States Department of Energy, Office of Nuclear Energy modeling and simulation programs, the MOOSE framework has been well-suited to multiscale, multiphysics modeling and simulation needs for nuclear systems. The framework is open-source, well-tested, under continuous development and deployment, and developed to a Nuclear Quality Assurance, Level 1 software quality standard. MOOSE has also been used in the fusion space previously in several projects: INL’s Tritium Migration Analysis Program, Version 8 (TMAP8) for tritium migration, UK Atomic Energy Authority’s A Unified Resource for OpenMC (fusion) Reactor Applications (AURORA) code for fusion thermo-mechanical and neutronics analysis, and Argonne National Laboratory’s Cardinal for high-fidelity computational fluid dynamics and neutronics. However, to model superconducting magnets, several MOOSE enhancements are required: additions to the current MOOSE electromagnetic capabilities, new material libraries for superconductors of interest (such as YBCO), as well as fusion-specific models for thermo-mechanics. This talk will discuss initial development activities to build these capabilities in MOOSE, focusing on initial validation and benchmarking activities. Proposed coupling workflows and future work to support the simulation of fusion magnets and magnet structural assemblies for performance and safety evaluation in MOOSE will also be discussed.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Utility-Scale Solar 2016: An Empirical Analysis of Project Cost, Performance, and Pricing Trends in the United States

The utility-scale solar sector has led the overall U.S. solar market in terms of installed capacity since 2012. In 2016, the utility-scale sector installed more than 2.5 times as much new capacity as did the residential and commercial sectors combined, and is expected to maintain its dominant position for at least another five years. This report—the fifth edition in an ongoing annual series—provides data-driven analysis of the utility-scale solar project fleet in the United States. We analyze not just installed project prices, but also operating costs, capacity factors, and power purchase agreement ("PPA") prices from a large sample of utility-scale PV and CSP projects throughout the United States. Highlights from this year's edition include the following: Installation Trends: The use of solar tracking devices dominated 2016 installations, at nearly 80% of all new capacity. In a reflection of the ongoing geographic expansion of the market beyond California and the Southwest, the median long-term average insolation level at newly built project sites declined again in 2016. While new fixed-tilt projects are now seen predominantly in less-sunny regions, tracking projects are increasingly pushing into these same regions. The median inverter loading ratio has stabilized in 2016 at 1.3 for both tracking and fixed-tilt projects. Installed Prices: Median installed PV project prices within a sizable sample have fallen by two-thirds since the 2007-2009 period, to $2.2/WAC (or $1.7/WDC) for projects completed in 2016. The lowest 20th percentile of projects within our 2016 sample were priced at or below $2.0/WAC, with the lowest-priced projects around $1.5/WAC. Overall price dispersion across the entire sample and across geographic regions decreased significantly in 2016. Operation and Maintenance (“O&M”) Costs: What limited empirical O&M cost data are publicly available suggest that PV O&M costs were in the neighborhood of $18/kWAC-year, or $8/MWh, in 2016. These numbers include only those costs incurred to directly operate and maintain the generating plant. Capacity Factors: The cumulative net AC capacity factors of individual PV projects range widely, from 15.4% to 35.5%, with a sample median of 26.3%. This project-level variation is based on a number of factors, including the strength of the solar resource at the project site, whether the array is mounted at a fixed-tilt or on a tracking mechanism, the inverter loading ratio, degradation, and curtailment. Changes in at least the first three of these factors drove mean capacity factors higher from 2010- to 2013-vintage projects, where they’ve remained fairly steady among both 2014- and 2015-vintage projects as an ongoing increase in the prevalence of tracking has been offset by a build-out of lower resource sites. Meanwhile, several of the newer CSP projects in the United States are struggling to match long-term performance expectations. PPA Prices: Driven by lower installed project prices and improving capacity factors, levelized PPA prices for utility-scale PV have fallen dramatically over time. Most recent PPAs in our sample are priced at or below $50/MWh levelized, with a few priced as aggressively as ~$30/MWh. Though impressive in pace and scale, these falling PPA prices have been offset to some degree by declining wholesale market value within high penetration markets like California, where in 2016 a MWh of solar generation was worth just 83% of a MWh of flat, round-the-clock generation. At the end of 2016, there were at least 121.4 GW of utility-scale solar power capacity within the interconnection queues across the nation. The growth within these queues is widely distributed across all regions of the country: California and the Southeast each account for 23% of the 83.3 GW of solar that first entered the queues in 2016, followed by the Northeast (17%), the Southwest (16%), the Central region (12%), Texas (6%) and the Northwest (3%). The widening geographic distribution of solar projects is a clear sign that the utility-scale market is maturing and expanding outside of its traditional high-insolation comfort zones.

14 SOLAR ENERGY↗

Gripper Test Assembly Status Report (FY2020)

Refueling systems for fast reactors are designed to handle fresh and used core assemblies (fuel, reflector, and shield core assemblies) within the reactor vessel in an opaque coolant environment without visual reference. These refueling machines are designed to work in a sodium (or other fast reactor coolant) and argon vapor space environment and are engineered with the rotatable plug system to allow for the movement of fresh and spent fuel into and out of the reactor core. The refueling machines are a critical component in any reactor and thus need to undergo extensive testing in a prototypic environment to ensure that they will meet all of the system functions and requirements. Argonne has developed an innovative compact refueling system design for the Advanced Fast Reactor-100 that is based upon some mechanisms used in previous reactor designs, such as the U.K.’s Prototype Fast Reactor (PFR) and some mechanisms that have not been used in sodium. This compact refueling machine supports the reduction in size of the AFR-100’s reactor vessel, and if fully developed, would support and inform the development of the in-vessel refueling machines for such commercial reactors as the GEH PRISM reactor plant, the ARC Clean Energy’s ARC-100 reactor, and the Natrium reactor, among others. This refueling system is a vital component of a fast reactor that supports reducing the cost of the reactor and increasing its reliability. During the development of the compact fuel handling machine conceptual design for the AFR-100, a lack of testing data for many mechanical components in sodium under typical in-reactor loads and conditions was discovered. The reduction in lifetime of the various mechanical components in the liquid sodium environment needs to be quantified versus the calculated component lifetimes under normal conditions in the testing while they are subjected to typical loading profiles experienced in the past. The Gripper Test Assembly discussed here includes a full-size gripper device with appropriate mechanical features that will be tested in sodium to provide this testing data. The Gripper Test Assembly is used to test various mechanical fuel handling components submerged in high temperature liquid sodium. These mechanisms are gears, bearings, gripper jaws and head, universal joints and shafts, ball screws, among others. These components will be tested under the typical sodium environmental conditions experienced during refueling operations with appropriate loading conditions that simulate the removal and insertion of core assemblies into a fast reactor grid plate structure. This Gripper Test Assembly is the second in a series of refueling system mechanisms developed for testing in sodium. The first test assembly is the Gear Test Assembly (GTA) which was used to test the performance of gears and bearings operating in sodium. Because of the successful testing conducted with the GTA, it was decided to continue with the development of the Gripper Test Assembly which uses the same gears and bearings tested in GTA. Using the data collected during operation of this gripper test assembly, lifetime reduction factors of the various mechanical components can be calculated for the material combinations selected. These lifetime reduction factors can be used in the design of future mechanical systems which operate in these environments to accurately predict component end of life. In addition, an understanding of the ability of these components and mechanisms to operate under-sodium with the chosen materials will be accomplished. Again, this Gripper Test Assembly is the follow-on test article to the Gear Test Assembly which was testing the ability of gears and bearings operating in a sodium environment. Once fabricated and qualified, it will be tested in the Mechanism Engineering Test Loop (METL) facility located in Building 308 at Argonne National Laboratory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

Planetary Protection Bioburden Analysis Program

This program is a Microsoft Access program that performed statistical analysis of the colony counts from assays performed on the Mars Science Laboratory (MSL) spacecraft to determine the bioburden density, 3-sigma biodensity, and the total bioburdens required for the MSL prelaunch reports. It also contains numerous tools that report the data in various ways to simplify the reports required. The program performs all the calculations directly in the MS Access program. Prior to this development, the data was exported to large Excel files that had to be cut and pasted to provide the desired results. The program contains a main menu and a number of submenus. Analyses can be performed by using either all the assays, or only the accountable assays that will be used in the final analysis. There are three options on the first menu: either calculate using (1) the old MER (Mars Exploration Rover) statistics, (2) the MSL statistics for all the assays, or This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software is programmed in Visual Basic for Applications for installation as a simple add-in for Microsoft Excel. The user is directed to a graphical user interface (GUI) that requires user inputs and provides solutions directly in Microsoft Excel workbooks. This work was done by Shannon Ryan of the USRA Lunar and Planetary Institute for Johnson Space Center. Further information is contained in a TSP (see page 1). MSC- 24582-1 Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program Lyndon B. Johnson Space Center, Houston, Texas Commercially, because it is so generic, Enigma can be used for almost any project that requires engineering visualization, model building, or animation. Models in Enigma can be exported to many other formats for use in other applications as well. Educationally, Enigma is being used to allow university students to visualize robotic algorithms in a simulation mode before using them with actual hardware. This work was done by David Shores and Sharon P. Goza of Johnson Space Center; Cheyenne McKeegan, Rick Easley, Janet Way, and Shonn Everett of MEI Technologies; Mark Manning of PTI; and Mark Guerra, Ray Kraesig, and William Leu of Tietronix Software, Inc. For further information, contact the JSC Innovation Partnerships Office at (281) 483-3809. MSC-24211-1 Spitzer Telemetry Processing System NASA's Jet Propulsion Laboratory, Pasadena, California The Spitzer Telemetry Processing System (SirtfTlmProc) was designed to address objectives of JPL's Multi-mission Image Processing Lab (MIPL) in processing spacecraft telemetry and distributing the resulting data to the science community. To minimize costs and maximize operability, the software design focused on automated error recovery, performance, and information management. The system processes telemetry from the Spitzer spacecraft and delivers Level 0 products to the Spitzer Science Center. SirtfTlmProc is a unique system with automated error notification and recovery, with a real-time continuous service that can go quiescent after periods of inactivity. The software can process 2 GB of telemetry and deliver Level 0 science products to the end user in four hours. It provides analysis tools so the operator can manage the system and troubleshoot problems. It automates telemetry processing in order to reduce staffing costs. This work was done by Alice Stanboli, Elmain M. Martinez, and James M. McAuley of Caltech for NASA's Jet Propulsion Laboratory. For more information, contact iaoffice @jpl.nasa.gov. This software is available for commercial licensing. Please contact Dan Broderick at Daniel.F. Broderick@jpl.nasa.gov. Refer to NPO-47803. NASA Tech Briefs, September 2013 29 This rapid response computer program predicts Orbiter Wing Leading Edge (WLE) damage caused by ice or foam impact during a Space Shuttle launch (Program "IMPACT2"). The program was developed after the Columbia accident in order to assess quickly WLE damage due to ice, foam, or metal impact (if any) during a Shuttle launch. IMPACT2 simulates an impact event in a few minutes for foam impactors, and in seconds for ice and metal impactors. The damage criterion is derived from results obtained from one sophisticated commercial program, which requires hours to carry out simulations of the same impact events. The program was designed to run much faster than the commercial program with prediction of projectile threshold velocities within 10 to 15% of commercial-program values. The mathematical model involves coupling of Orbiter wing normal modes of vibration to nonlinear or linear springmass models. IMPACT2 solves nonlinear or linear impact problems using classical normal modes of vibration of a target, and nonlinear/ linear time-domain equations for the projectile. Impact loads and stresses developed in the target are computed as functions of time. This model is novel because of its speed of execution. A typical model of foam, or other projectile characterized by material nonlinearities, impacting an RCC panel is executed in minutes instead of hours needed by the commercial programs. Target damage due to impact can be assessed quickly, provided that target vibration modes and allowable stress are known. This work was done by Robert Clark, Jr., Paul Cotter, and Constantine Michalopoulos of The Boeing Company for Johnson Space Center. For further information, contact the JSC Innovation Partnerships Office at (281) 483-3809. MSC-24988-1 Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2) Lyndon B. Johnson Space Center, Houston, Texas (3) the MSL statistics for only the accountable assays. Other options on the main menu include a data editing form and utility programs that produce various reports requested by the microbiologists and the project, and tools to generate the groupings for the final analyses. The analyses can be carried out in three ways: Each assay can be treated separately, the assays can be collectively treated for the whole zone as a group, or the assays can be collected in groups designated by the JPL Planetary Protection Manager. The latter approach was used to generate the final report because assays on the same equipment or similar equipment can be assumed to have been exposed to the same environment and cleaning. Thus, the statistics are improved by having a larger population, thereby reducing the standard deviation by the square root of N. For each method mentioned above, three reports are available. The first is a detailed report including all the data. This version was very useful in verifying the calculations. The second is a brief report that is similar to the full detailed report, but does not print out the data. The third is a grand total and summary report in which each assay requires only one line. For the first and second reports, most of the calculations are performed in the report section itself. For the third, all the calculations are performed directly in the query bound to the report. All the numerical results were verified by comparing them with Excel templates, then exporting the data from the Planetary Protection Analysis program to Excel.

Beaudet, Robert A.↗

Multimodal Nondestructive Dry Cask Basket Structure and Spent Fuel Evaluation

This NEUP-IRP assembled a team from diverse institutions and a diverse set of expertise to examine the problem of assessing the structural health of dry nuclear fuel storage casks, specifically the TN-32 design. With no physical access designed into these storage casks and the high cost and risk associated with opening casks for direct inspection, the technical difficulty of structural assessment of the basket structure and fuel assemblies is high. In response to this challenge, this IRP brought together experts in both traditional and novel NDE methodologies: active acoustics (University of Mississippi), emissions tomography (University of Florida), muon tomography (Oregon State University), and passive-active ultrasonics (University of South Carolina). Further, our industry partners in the Electric Power Research Institute (EPRI) and AREVA provided invaluable insight into technical design details for the cask, practical knowledge of operating parameters at a storage facility, and key relationships that enabled activities unforeseen at the time of the proposed work but were critical in guiding the path of the research. The team decided early in the project that we had a collective goal of laying the technical ground work for practical solutions that could be implemented in the field with reasonable cost, time, and reliability. A fortunate opportunity arose early in this IRP project to obtain access to a new TN-32 cask at Columbiana High Tech. Both acoustics teams were given access for testing concepts in the first year of the project. This ended up providing critical guidance in the design of subsequent laboratory experiments. Specifically, it became clear that the only reliable acoustic pathways to the interior were through the trunnions, base plate, and top ring of the cask. Based on these field tests and discussions about what would be of practical interest, the team as a whole decided a realistic goal was to detect catastrophic failure of a single fuel assembly, or one that was missing. It is clear from this work that the active acoustics / resonance and muon tomography methodologies would be capable of detecting interior structural integrity problems at this level. The other two areas of investigation (emissions tomography and passive/active ultrasonics) would need more testing to determine a successful implementation, but each may also have other applications such as long term monitoring and monitoring during transportation. This IRP project resulted in technical advances with applications that extend beyond the problem at hand, supported the training of 10 graduate students + 1 post doc, 21 publications, and 13 conference presentations. The remainder of this summary highlights significant activities and achievements in each of the methodologies and a brief discussion on how they can be combined to leverage strengths. Active Acoustics The active acoustics team at UM used both linear and non-linear structural resonance methods to infer information about the internal structure of a cask. Significant activities were a set of four field test measurements on a full scale TN-32 cask at the Columbiana Hi Tech facility in Greensboro, NC and the design and fabrication of a 1/6th scale model TN-32 cask for laboratory measurements. A significant set of acoustic data has been acquired on both the full scale and laboratory scale casks. It was determined early in the project that mechanical resonance techniques were not going to be sensitive to small scale (centimeter) cracks and structural defects in the basket structure or fuel assemblies. We were able to ascertain that both the energy and complexity of the resonance spectra were sensitive to “bulk state” of the fuel assemblies – an intact assembly versus a severely degraded assembly. By developing a novel combination of metrics, we are able to measure a statistically significant shift due to one out of the 32 fuel assemblies being either missing or degraded to a point of complete loss of structural coherence (i.e. “rubble”). We believe this combination of resonance metrics is new to the field and will have applications beyond the fuel storage problem. Emissions Tomography The Emissions Tomography team at the University of Florida explored the concept of using scattering of radiation emissions from the stored fuel as method of evaluating the internal structural health of the cask. Due to the need for emissive fuel assemblies and the difficulties of gaining access to storage facilities, this team primarily relied on simulations to inform feasibility. A key question was the flux estimates of neutrons with a small enough number of scattering events to retain spatial information. Some key conclusions from the transmission component of this work are that the number of scattering events falls rapidly with energy – setting a 11MeV threshold, the average number of scattering events is 8∓4. Rough estimates of scanning times using an ideal detector array would be 1 week. The team also explored the case of significant structural failure resulting in a shift of the source material (fuel). The result is that a +/- 2% mass shift results in a detectable (5.13%) shift in the correlated 2 neutron emission counts and thus may be a candidate as an initial survey. Finally, simulations for predicting the azimuthal dependence of the flux based on specific loading patterns were conducted. Due to self-shielding effects of the assemblies, a periodic pattern results and could potentially be used to identify missing or severely degraded assemblies. This work forms a basis for proper detector placement with the goal of optimizing sensitivity. Muon Tomography Muon tomography (MT) is a relatively novel method of interrogating interior structure on a large scale. One of the advantages of this technique is that the exciting energy source (cosmic muons) is ubiquitous and relatively stable in time. Challenging aspects are relatively low flux rates and appropriate detector technologies. The efforts of the muon group at Oregon State University focused on two areas: (1) simulation of various combinations of muon scattering events and detection schemes to assess sensitivities and time scales for image construction and (2) building a prototype muon detection system applicable to the dry storage cask problem as well as many other similar systems. Significant accomplishments in this area are: (1) demonstration that MT is a viable method for detecting missing or severely degraded rod assemblies, (2) a scintillation based detector with 4 panels and 32 channels of position data each were constructed, tested, and calibrated. Testing of the panels using natural muon background and no scattering objects yielded largely expected results – a straight line path for the muon through the four panels. However some anomalies (paths deviating from a line) were also detected. A redesign of the board improved the signal which greatly improved the muon tracking through the panels. Testing with lead bricks as scattering bodies showed a reduction in the coincidence rate with increasing bricks indicating increased scattering events. A refinement of the scintillator detector design resulted in a spatial image resolution of around 2 cm based on lead brick spacing tests lasting 24 hours. Passive/Active Ultrasonics This team at the University of South Carolina investigated the feasibility of combining passive ultrasonics, in which an elastic pulse is generated by a degradation process (such as a crack extending), and active ultrasonics, in which a known excitation is introduced into the structure and detected by an array of transducers. Significant accomplishments in this area include the development of elastic wave propagation simulation in relevant materials, development of diagnostic algorithms, and laboratory testing and validation using laser doppler vibrometry. This group demonstrated the applicability of various non-contact vibration detection methodologies such as air-coupled ultrasonic transducers and scanning laser doppler vibrometry. While passive acoustic emissions monitoring will likely have a role during the transportation of a fuel storage cask, the level of detailed information about the defect generating the event which can be ascertained from the detections in a complex structure remains for future work. Thermography The EPRI team contributed early in the project a series of thermography measurements in which various levels of water pooled in a mock-up canister were analyzed using commercially available infrared imaging technologies. While large levels of water (100 L, ~10 cm deep) were observable in the thermograms, more realistic levels of pooled water (1 L) were not detectable whether localized or distributed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗