Some limitations on ion-cyclotron wave generation and subsequent ion heating in magnetic beaches
Finite ion and electron temperature effect on ion cyclotron waves generated by Stix coil, and subsequent plasma ion heating in magnetic beaches
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Finite ion and electron temperature effect on ion cyclotron waves generated by Stix coil, and subsequent plasma ion heating in magnetic beaches
Wide-range nuclear magnetic resonance probe design including integrated circuits, RF coil, and coaxial cable for use with high field cryogenic magnets
Supersonic wind tunnel electromagnetic balance with superconducting coils
Auxiliary propulsion system using low power MPD thrustors, discussing feasibility of thrust vectoring with skewed magnetic coil arrangement
Air-water flow pressure loss and phase distribution in tube with wire coil swirl generators
Circuitry utilizing electrical feedback of instantaneous speaker coil velocity compensates for loudspeaker resonance, transient peaks and frequency drop-off so that sounds of widely varying frequencies and amplitudes can be reproduced accurately from high fidelity recordings of any variety.
Coiled section of tubing measures viscous properties of gelled cryogenic propellants under conditions closely resembling flow in rocket engine systems. Characteristic flow curve provides data necessary for the design of prototype hardware systems using the liquid or gel of interest.
New design is proposed for ferrofluidic solenoid with low magnetic flux leakage. Solenoid consists of a coil centered within a football-shaped elastomeric capsule filled with a ferromagnetic fluid. Fluid replaces the solid, movable core of conventional solenoids, and elastomeric capsule acts as return spring.
Valve concept has been devised which offers lightweight, simplified mechanism capable of automatic control of large number of fluid flow ports. Valve control is achieved with valve stem which is bimetallic device activated by heating coil to open or close selected supply port. Number of controlled ports is limited only by desired physical size of system.
Instrument for nondestructively measuring compression resistance of spray foam used as thermal insulation was developed. Cylindrical indicator has probe with coil spring to provide force and indicating dial. Probe is manually pressed against area to be tested until complete foot area contacts foam surfaces.
Improved control of laser beam deflection angles may result from new conceptual device. Reflectively coated magnetized particles are suspended in liquid-filled cell surrounded by two pairs of crossed electromagnetic coils and are selectively aligned by controlling magnetic fields. Ultrasonic energy source keeps particles suspended.
Instrument for measuring magnetic permeability of materials undergoing heat treatment as method for monitoring stress relief and tempering is described. Procedure is based on magnetic potentiometer principle with yoke compensating coils to cancel effects of reluctance of yoke and joint gaps. Instrument is heated with specimen being heat treated.
Switch concept provides simple means of achieving electromechanical time delay function. Unit consists of reed-type circuit breaker enclosed by copper tubing with electromagnetic coil wound around tubing and entire assembly mounted on insulating platform. Characteristics are affected only by geometry of system so device is expected to be very stable.
Overflow sensor for cryogenic fluid vessels has been designed by winding electrical resistance element on porous tubular coil form. Form is positioned in overflow vent of cryogenic fluid vessel where it can differentiate vapor from liquid at same temperature.
Waste heat from radioisotope thermal generators in spacecraft is transported to keep instruments warm by two-cylinder reciprocating pump powered by energy from warm heat exchange fluid. Each cylinder has thermally nonconductive piston, heat exchange coil, and heat sink surface.
A cryogenic gravity meter made of two parts, a magnetic suspension unit and a detection module, was used to monitor earth eigen vibrations. The magnetic field and field gradient are generated by energizing a set of superconducting coils made of niobium-zirconium alloy wire. The detection module is a double Josephson junction magnetometer. The output is printed on a chart recorder and later digitized using a computer; a Fourier transformation is performed on the accumulated data. The measurements of eigen vibrations are summarized in tabular and graphical representations.
A permeameter is described that measures the magnetizing force and the corresponding magnetic induction up to 1000 C. The two symmetrical yokes are made of an alloy of 9 percent iron, 91 percent cobalt. A coil surrounding the specimen supplies a magnetizing force of up to 100 oersteds. The instrument uses the magnetic potentiometer principle to cancel the effects of the reluctance of the yoke and the joint gaps. Very close agreement was obtained at room temperature when compared to an MH type permeameter. The effect of temperature on the normal induction curves for the yoke material is also presented.
A three axis magnetometer system intended for use in the magnetic measurement of lunar rock samples was designed, fabricated and delivered to NASA Manned Spacecraft Center. The system has a four inch diameter room temperature sample access region and is fitted with three orthogonal magnetic field sensors enclosing this region. Two superconducting magnetic shields are incorporated, which are designed to eliminate external magnetic noise from the sense coils. A superconducting solenoid is mounted coaxially with the sample region and this provides axial magnetic fields up to 1,000 gauss. The system was designed for measuring magnetic moments of geophysical samples, especially remanent moments of lunar samples. The sensitivity of the system in all three axes is about 2 x 10 to the -7th power EMU square root HZ peak to peak, measured in the 0 to 1 Hz bandwidth.